• Title/Summary/Keyword: ramp direction

Search Result 32, Processing Time 0.015 seconds

Analysis of Built and Walking Environment for Coastal Ferry Terminal using IPA -Focusing on Yeosu Coastal Ferry Terminal- (IPA를 이용한 연안여객터미널의 시설 및 보행특성 분석 -여수연안여객터미널을 중심으로-)

  • Song, Tea-Han;Kim, Hwa-Young
    • Journal of Korea Port Economic Association
    • /
    • v.37 no.3
    • /
    • pp.93-104
    • /
    • 2021
  • A coastal ferries, which serve as a mode between mainland and offshore islands, are frequently used by islanders and travelers visiting islands. Therefore, it is located in a place with good accessibility to the downtown so that users can use it conveniently. However, research on the built environment and walking environment of coastal ferry terminals has not been conducted to ensure that elderly islanders and general travelers can use comfortably the coastal ferry terminal. In this study, with a focus on the coastal ferry terminal space, the walking section was set as 1)the accessibility of the coastal ferry terminal, 2)the built environment for using the coastal ferry terminal, and 3)walking environment in the ferry boarding and disembarkation at the coastal ferry terminal, and 4, 5)walking environment in the ferry. An evaluation tool was developed to measure the walking environment for each walking section, and the importance and satisfaction of users were analyzed using the IPA for the Yeosu Coastal Ferry Terminal. As a result, in the process of approaching the ferry terminal, 'convenience of using public transportation by foot' and 'convenience of using signposts guiding the location and direction of the ferry terminal' were investigated as concentrated areas. On the other hand, the built environment inside the ferry terminal and the walking environment showed that the satisfaction of the users was high. Regarding the walking environment from the ferry terminal to the ferry, the 'surface walking environment of the walking path', 'convenience of walking with luggage', 'convenience of walking in the slope section', and 'convenience of walking in the ferry ramp section' showed low satisfaction. This study can be used as basic data for improving the facilities and walking environment of Yeosu Coastal Ferry Terminal and is expected to be used as data for comparative research with other coastal ferry terminals.

Performance Evaluation of Siemens CTI ECAT EXACT 47 Scanner Using NEMA NU2-2001 (NEMA NU2-2001을 이용한 Siemens CTI ECAT EXACT 47 스캐너의 표준 성능 평가)

  • Kim, Jin-Su;Lee, Jae-Sung;Lee, Dong-Soo;Chung, June-Key;Lee, Myung-Chul
    • The Korean Journal of Nuclear Medicine
    • /
    • v.38 no.3
    • /
    • pp.259-267
    • /
    • 2004
  • Purpose: NEMA NU2-2001 was proposed as a new standard for performance evaluation of whole body PET scanners. in this study, system performance of Siemens CTI ECAT EXACT 47 PET scanner including spatial resolution, sensitivity, scatter fraction, and count rate performance in 2D and 3D mode was evaluated using this new standard method. Methods: ECAT EXACT 47 is a BGO crystal based PET scanner and covers an axial field of view (FOV) of 16.2 cm. Retractable septa allow 2D and 3D data acquisition. All the PET data were acquired according to the NEMA NU2-2001 protocols (coincidence window: 12 ns, energy window: $250{\sim}650$ keV). For the spatial resolution measurement, F-18 point source was placed at the center of the axial FOV((a) x=0, and y=1, (b)x=0, and y=10, (c)x=70, and y=0cm) and a position one fourth of the axial FOV from the center ((a) x=0, and y=1, (b)x=0, and y=10, (c)x=10, and y=0cm). In this case, x and y are transaxial horizontal and vertical, and z is the scanner's axial direction. Images were reconstructed using FBP with ramp filter without any post processing. To measure the system sensitivity, NEMA sensitivity phantom filled with F-18 solution and surrounded by $1{\sim}5$ aluminum sleeves were scanned at the center of transaxial FOV and 10 cm offset from the center. Attenuation free values of sensitivity wire estimated by extrapolating data to the zero wall thickness. NEMA scatter phantom with length of 70 cm was filled with F-18 or C-11solution (2D: 2,900 MBq, 3D: 407 MBq), and coincidence count rates wire measured for 7 half-lives to obtain noise equivalent count rate (MECR) and scatter fraction. We confirmed that dead time loss of the last flame were below 1%. Scatter fraction was estimated by averaging the true to background (staffer+random) ratios of last 3 frames in which the fractions of random rate art negligibly small. Results: Axial and transverse resolutions at 1cm offset from the center were 0.62 and 0.66 cm (FBP in 2D and 3D), and 0.67 and 0.69 cm (FBP in 2D and 3D). Axial, transverse radial, and transverse tangential resolutions at 10cm offset from the center were 0.72 and 0.68 cm (FBP in 2D and 3D), 0.63 and 0.66 cm (FBP in 2D and 3D), and 0.72 and 0.66 cm (FBP in 2D and 3D). Sensitivity values were 708.6 (2D), 2931.3 (3D) counts/sec/MBq at the center and 728.7 (2D, 3398.2 (3D) counts/sec/MBq at 10 cm offset from the center. Scatter fractions were 0.19 (2D) and 0.49 (3D). Peak true count rate and NECR were 64.0 kcps at 40.1 kBq/mL and 49.6 kcps at 40.1 kBq/mL in 2D and 53.7 kcps at 4.76 kBq/mL and 26.4 kcps at 4.47 kBq/mL in 3D. Conclusion: Information about the performance of CTI ECAT EXACT 47 PET scanner reported in this study will be useful for the quantitative analysis of data and determination of optimal image acquisition protocols using this widely used scanner for clinical and research purposes.