• Title/Summary/Keyword: railway signal

Search Result 441, Processing Time 0.024 seconds

Structural health monitoring of high-speed railway tracks using diffuse ultrasonic wave-based condition contrast: theory and validation

  • Wang, Kai;Cao, Wuxiong;Su, Zhongqing;Wang, Pengxiang;Zhang, Xiongjie;Chen, Lijun;Guan, Ruiqi;Lu, Ye
    • Smart Structures and Systems
    • /
    • v.26 no.2
    • /
    • pp.227-239
    • /
    • 2020
  • Despite proven effectiveness and accuracy in laboratories, the existing damage assessment based on guided ultrasonic waves (GUWs) or acoustic emission (AE) confronts challenges when extended to real-world structural health monitoring (SHM) for railway tracks. Central to the concerns are the extremely complex signal appearance due to highly dispersive and multimodal wave features, restriction on transducer installations, and severe contaminations of ambient noise. It remains a critical yet unsolved problem along with recent attempts to implement SHM in bourgeoning high-speed railway (HSR). By leveraging authors' continued endeavours, an SHM framework, based on actively generated diffuse ultrasonic waves (DUWs) and a benchmark-free condition contrast algorithm, has been developed and deployed via an all-in-one SHM system. Miniaturized lead zirconate titanate (PZT) wafers are utilized to generate and acquire DUWs in long-range railway tracks. Fatigue cracks in the tracks show unique contact behaviours under different conditions of external loads and further disturb DUW propagation. By contrast DUW propagation traits, fatigue cracks in railway tracks can be characterised quantitatively and the holistic health status of the tracks can be evaluated in a real-time manner. Compared with GUW- or AE-based methods, the DUW-driven inspection philosophy exhibits immunity to ambient noise and measurement uncertainty, less dependence on baseline signals, use of significantly reduced number of transducers, and high robustness in atrocious engineering conditions. Conformance tests are performed on HSR tracks, in which the evolution of fatigue damage is monitored continuously and quantitatively, demonstrating effectiveness, adaptability, reliability and robustness of DUW-driven SHM towards HSR applications.

Transmission Performance of Application Traffics on High Speed Railway Communications (고속철도통신에서 응용 트래픽의 전송성능)

  • Kim, Young-Dong
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.12 no.5
    • /
    • pp.771-776
    • /
    • 2017
  • LTE-R mobile communication technology based on LTE is used to supply various signal and exchange information required for safety operation of train on high speed railway communication system. In this paper, transmission performance of application traffic which is transferred on high speed communication based on LTE-R is analyzed. And some suggestions for application traffic transmission of high speed railway communication will be considered. Computer simulation is used to analyze performance of CBR, VBR as application traffic. Throughput, delay and packet loss rate is used as performance measurement and analysis parameters.

Improvement Plans of Railway standards for Surge Protective Devices used in Low-voltage Power circuits (저전압 전원용 서지보호장치 철도 규격의 개선방안)

  • 정용철;김언석;이재호;조봉관;김재철
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.16 no.2
    • /
    • pp.90-97
    • /
    • 2002
  • In this paper we study the performance test items and improvement plans of surge protective devices for low-voltage power circuits used in railway system. Above of all, the sources of electromagnetic interference in railway system are researched. And then we compared domestic railway standard with IEC and IEEE standards far the test items and methodologies of surge protective devices. Through the investigations, we found that the domestic standard is behind in the number of test items and methods on surge protective devices. As the countermeasures, we suggest removing component tests of surge protective devices, separating standards for power and signal standards, and using international surge waveform. In applying to domestic railway surge protective devices, surge limiting voltage measuring and surge endurance tests by international standard methods are good result.

A Study on the Cause Analysis of Human Error Accidents by Railway Job

  • Byeoung-Soo YUM;Tae-Yoon KIM;Sun-Haeng CHOI;Won-Mo GAL
    • Journal of Wellbeing Management and Applied Psychology
    • /
    • v.7 no.1
    • /
    • pp.27-33
    • /
    • 2024
  • Purpose: This study investigates human error accidents in the Korean railway sector, emphasizing the need for systematic management to prevent such incidents, which can have fatal consequences, especially in driving-related jobs. Research design, data and methodology: This paper analyzed data from the Aviation and Railway Accident Investigation Board and the Korea Transportation Safety Authority, examining 240 human error accidents that occurred over the last five years (2018-2022). The analysis focused on accidents in the driving, facility, electric, and control fields. Results: The findings indicate that the majority of human error accidents stem from negligence in confirmation checks, issues with work methods, and oversight in facility maintenance. In the driving field, errors such as signal check neglect and braking failures are prevalent, while in the facility and electric fields, the main issues are maintenance delays and neglect of safety measures. Conclusions: The paper concludes that human error accidents are complex and multifaceted, often resulting from a high workload on engineers and systemic issues within the railway system. Future research should delve into the causal relationships of these accidents and develop targeted prevention strategies through improved work processes, education, and training.

Structural Damage Detection by Using the Time-Reversal Process of Lamb Waves and the Imaging Method (Lamb파의 시간-반전과정 및 이미지기법을 이용한 손상탐지)

  • Jun, Yong-Ju;Lee, U-Sik
    • Journal of the Korean Society for Railway
    • /
    • v.14 no.4
    • /
    • pp.320-326
    • /
    • 2011
  • This paper proposes a baseline-free SHM technique in which the time-reversal process of Lamb waves and the imaging method are used. The proposed SHM technique has three distinct features when compared with the authors' previously proposed one: (1) It use the reconstructed signal for damage diagnosis, without need to extract the damage signal as the difference between reconstructed signal and initial input signal; (2) It use the imaging method based on the time-offlight information from the reconstructed signal, instead of using a pattern comparison method; (3) In order to make the damage image more clear, the modified mathematical definition of damage image in a pixel is used. The proposed SHM technique is evaluated through the damage detection experiment for an aluminum plate with damage at different locations.

Performance improvement of serial communication converter of train control computer (열차제어컴퓨터 시리얼통신변환장치(HADAX)의 성능개선에 관한 연구)

  • Cho, Bong-Kwan
    • Journal of The Korean Society For Urban Railway
    • /
    • v.6 no.4
    • /
    • pp.427-436
    • /
    • 2018
  • HADAX is a serial communication converter of train control computer. It is connected with various signal equipments such as wayside signal equipments, station signal equipments, train control computers, and transmits control information and signal condition information for train control. And transmits information to several electronic interlocking devices through a splitter interface. Since HADAX interfaces with many signaling devices through serial communication, frequent communication connection faults necessitate improvement of performance such as dual system configuration, integration of external splitter, and multi-channelization of communication card. The improved HADAX device should have compatibility with the dimensions of existing enclosure and enclosure, and verify the performance of dual system and splitter integration. Therefore, we verified the performance of HADAX through the route control test, dual system test, and multi-channel communication test with splitter integrated connection by connecting with the existing signal equipment.

A Study of Tilting Train Signal System for Conventional Rail Speed-Up

  • Han, Seong-Ho;Lee, Su-Gil;Ko, Tae-Hwan;Song, Yong-Soo;Han, Young-Jae
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2003.10a
    • /
    • pp.1741-1744
    • /
    • 2003
  • This study is a kind of preliminary research in order to propose and suggest the plan of performance improvement for the speed-up through the examination of operational condition on the field for signal system facility on the conventional railway, in order to obtain the elemental technology from the technical development for utilization of high speed train which will be run on the Korea Conventional Line and, finally, in order to propose the specification of signal system using for high speed and the scheme of establishment for the optimal signal system.

  • PDF

The study of data interface for train onboard signal control system (차상신호시스템의 정보인터페이스에 관한 연구)

  • Kim You-Ho;Lee Hoon-Koo;Lee Soo-Hwan;Kim Young Kyu;Baek Jong-Hyen
    • Proceedings of the KSR Conference
    • /
    • 2004.06a
    • /
    • pp.1240-1246
    • /
    • 2004
  • Research for Tilting Vehicle is in progress as a plan follows in speed improvement of the existing railroad. According to this, Onboard Signal Control System is considered for introduction of new technology on Onboard equipment of railroad signal system and control system. Onboard Signal Control System operates the train by using of information that received from the ground. Examine the connection algorithm between kind of equipment and each equipment which will be installed for the On board Signal Control System. And examined about information interface and kind of information.

  • PDF

Research on the Correlation of Control Malfunction with Induced Voltage of Control Signal Line According to Voltage Change of a Power Line

  • Kang, Dong-Woo;Kim, In-Gun;Ham, Sang-Hwan;Kim, Sung-Yul;Bae, Sungwoo;Kim, Dae-Nyeon;Lee, Ju
    • Journal of Electrical Engineering and Technology
    • /
    • v.11 no.3
    • /
    • pp.775-780
    • /
    • 2016
  • This induced voltage measurement test and electromagnetic field simulation are related to the possibility of control signal malfunction by power line. Through an experiment, this research analyzed whether the voltage causing control malfunction according to the on/off status of power permitted to power line was induced to control signal line. Also, the research calculated the voltage induced to control signal line and examined the phenomenon by conducting an electro-magnetic field-specific simulation through the finite element method for the cable model used in the experiment.

Vibration Signal Analysis of Running Electric Train using Adaptive Signal Processing (적응신호처리에 의한 주행전기동차의 진동신호해석)

  • 최연선;이봉현
    • Proceedings of the KSR Conference
    • /
    • 1999.05a
    • /
    • pp.143-150
    • /
    • 1999
  • The vibration signals of driving parts of electric train are distorted its signal patterns due to the impact components, which occurs when wheel passes rail joints. An elimination method of the impact components is investigated using adaptive signal processing technique in this study. The result shows that adaptive interference canceling method seems to be more effective than line enhancement technique. The application of adaptive interference canceling method to the signal measured at bogie shows that the extractions of the signals of driving parts of traction motor, reduction gear, and axle bearing are successful. Therefore, only the signals of bogie, which is the place to attach an accelerometer easily, is sufficient for the fault diagnosis and the safety evaluation of electric train. Also, adaptive interference canceling method can be applicable to evaluate the performance of vibration isolation between bogie and car body and to investigate the characteristics of indoor sound.

  • PDF