• 제목/요약/키워드: radiotherapy planning

검색결과 330건 처리시간 0.023초

Dosimetric Evaluation of 3-D Conformal and Intensity-modulated Radiotherapy for Breast Cancer after Conservative Surgery

  • Mansouri, Safae;Naim, Asmaa;Glaria, Luis;Marsiglia, Hugo
    • Asian Pacific Journal of Cancer Prevention
    • /
    • 제15권11호
    • /
    • pp.4727-4732
    • /
    • 2014
  • Background: Breast cancers are becoming more frequently diagnosed at early stages with improved long term outcomes. Late normal tissue complications induced by radiotherapy must be avoided with new breast radiotherapy techniques being developed. The aim of the study was to compare dosimetric parameters of planning target volume (PTV) and organs at risk between conformal (CRT) and intensity-modulated radiation therapy (IMRT) after breast-conserving surgery. Materials and Methods: A total of 20 patients with early stage left breast cancer received adjuvant radiotherapy after conservative surgery, 10 by 3D-CRT and 10 by IMRT, with a dose of 50 Gy in 25 sessions. Plans were compared according to dose-volume histogram analyses in terms of PTV homogeneity and conformity indices as well as organs at risk dose and volume parameters. Results: The HI and CI of PTV showed no difference between 3D-CRT and IMRT, V95 gave 9.8% coverage for 3D-CRT versus 99% for IMRT, V107 volumes were recorded 11% and 1.3%, respectively. Tangential beam IMRT increased volume of ipsilateral lung V5 average of 90%, ipsilateral V20 lung volume was 13%, 19% with IMRT and 3D-CRT respectively. Patients treated with IMRT, heart volume encompassed by 60% isodose (30 Gy) reduced by average 42% (4% versus 7% with 3D-CRT), mean heart dose by average 35% (495cGy versus 1400 cGy with 3D-CRT). In IMRT minimal heart dose average is 356 cGy versus 90cGy in 3D-CRT. Conclusions: IMRT reduces irradiated volumes of heart and ipsilateral lung in high-dose areas but increases irradiated volumes in low-dose areas in breast cancer patients treated on the left side.

Dosimetric comparison of intensity-modulated radiotherapy (IMRT) and volumetric modulated arc therapy (VMAT) in total scalp irradiation: a single institutional experience

  • Ostheimer, Christian;Hubsch, Patrick;Janich, Martin;Gerlach, Reinhard;Vordermark, Dirk
    • Radiation Oncology Journal
    • /
    • 제34권4호
    • /
    • pp.313-321
    • /
    • 2016
  • Purpose: Total scalp irradiation (TSI) is a rare but challenging indication. We previously reported that non-coplanar intensity-modulated radiotherapy (IMRT) was superior to coplanar IMRT in organ-at-risk (OAR) protection and target dose distribution. This consecutive treatment planning study compared IMRT with volumetric-modulated arc therapy (VMAT). Materials and Methods: A retrospective treatment plan databank search was performed and 5 patient cases were randomly selected. Cranial imaging was restored from the initial planning computed tomography (CT) and target volumes and OAR were redelineated. For each patients, three treatment plans were calculated (coplanar/non-coplanar IMRT, VMAT; prescribed dose 50 Gy, single dose 2 Gy). Conformity, homogeneity and dose volume histograms were used for plan. Results: VMAT featured the lowest monitor units and the sharpest dose gradient (1.6 Gy/mm). Planning target volume (PTV) coverage and homogeneity was better in VMAT (coverage, 0.95; homogeneity index [HI], 0.118) compared to IMRT (coverage, 0.94; HI, 0.119) but coplanar IMRT produced the most conformal plans (conformity index [CI], 0.43). Minimum PTV dose range was 66.8%-88.4% in coplanar, 77.5%-88.2% in non-coplanar IMRT and 82.8%-90.3% in VMAT. Mean dose to the brain, brain stem, optic system (maximum dose) and lenses were 18.6, 13.2, 9.1, and 5.2 Gy for VMAT, 21.9, 13.4, 14.5, and 6.3 Gy for non-coplanar and 22.8, 16.5, 11.5, and 5.9 Gy for coplanar IMRT. Maximum optic chiasm dose was 7.7, 8.4, and 11.1 Gy (non-coplanar IMRT, VMAT, and coplanar IMRT). Conclusion: Target coverage, homogeneity and OAR protection, was slightly superior in VMAT plans which also produced the sharpest dose gradient towards healthy tissue.

PET/CT planning during chemoradiotherapy for esophageal cancer

  • Seol, Ki Ho;Lee, Jeong Eun
    • Radiation Oncology Journal
    • /
    • 제32권1호
    • /
    • pp.31-42
    • /
    • 2014
  • Purpose: To evaluate the usefulness of positron emission tomography/computed tomography (PET/CT) for field modification during radiotherapy in esophageal cancer. Materials and Methods: We conducted a retrospective study on 33 patients that underwent chemoradiotherapy (CRT). Pathologic findings were squamous cell carcinoma in 32 patients and adenocarcinoma in 1 patient. All patients underwent PET/CT scans before and during CRT (after receiving 40 Gy and before a 20 Gy boost dose). Response evaluation was determined by PET/CT using metabolic tumor volume (MTV), total glycolytic activity (TGA), MTV ratio (rMTV) and TGA ratio (rTGA), or determined by CT. rMTV and rTGA were reduction ratio of MTV and TGA between before and during CRT, respectively. Results: Significant decreases in MTV ($MTV_{2.5}$: mean 70.09%, p < 0.001) and TGA ($TGAV_{2.5}$: mean 79.08%, p < 0.001) were found between before and during CRT. Median $rMTV_{2.5}$ was 0.299 (range, 0 to 0.98) and median $rTGAV_{2.5}$ was 0.209 (range, 0 to 0.92). During CRT, PET/CT detected newly developed distant metastasis in 1 patient, and this resulted in a treatment strategy change. At a median 4 months (range, 0 to 12 months) after completion of CRT, 8 patients (24.2%) achieved clinically complete response, 11 (33.3%) partial response, 5 (15.2%) stable disease, and 9 (27.3%) disease progression. $SUV_{max}$ (p = 0.029), $rMTV_{50%}$ (p = 0.016), $rMTV_{75%}$ (p = 0.023) on intra-treatment PET were found to correlate with complete clinical response. Conclusion: PET/CT during CRT can provide additional information useful for radiotherapy planning and offer the potential for tumor response evaluation during CRT. $rMTV_{50%}$ during CRT was found to be a useful predictor of clinical response.

자궁 경부암의 방사선 치료계획에서 자기공명 영상을 이용한 조사야 교정 (Treatment Planning Correction Using MRI in the Radiotherapy of Cervical Cancer)

  • 신세원;조길호;박찬원
    • Journal of Yeungnam Medical Science
    • /
    • 제12권2호
    • /
    • pp.203-209
    • /
    • 1995
  • 본 연구는 최근에 개발되어 임상적으로 널리 이용되는 자기공명 영상상을 20명의 자궁 경부암 환자의 치료계획에 적용하여 전통적인 치료계획과 비교하여 아래의 결과를 얻었다. 1. 측방 조사야의 가로길이는 11 cm가 7명(35%)으로 가장 많았으며, 10 cm가 6명(30%), 9 cm와 12 cm가 각각 3명(15%)이었으며 13 cm는 1명(5%)이었다. 2. 측방 조사야의 중심 이동은 자궁의 크기나 골반의 횡경과는 무관하였다. 3. 자기공명 영상을 이용한 방사선치료계획을 한 결과 전통적인 방법으로 결정된 전골반 측방 조사야의 변경이 20명 중 5명(25%)에서 있었으므로 향후 자궁 경부암이나 자궁 체부암의 정확한 치료를 위해서는 자기공명 영상이 매우 중요함을 시사하였으며 향후 더 많은 환자를 대상으로 자기공명 영상을 이용한 방사선치료 성적을 전통적인 방법에 의한 성적과 비교하는 연구가 요구된다.

  • PDF

Hippocampal Sparing Whole Brain Radiotherapy and Integrated Simultaneous Boost vs Stereotactic Radiosurgery Boost: A Comparative Dosimetric Planning Study

  • Cheah, Soon Keat;Matthews, Thomas;Teh, Bin Sing
    • Asian Pacific Journal of Cancer Prevention
    • /
    • 제17권9호
    • /
    • pp.4233-4235
    • /
    • 2016
  • Background: Whole brain radiotherapy (WBRT) and stereotactic radiosurgery were frequently used to palliate patients with brain metastases. It remains controversial which modality or combination of therapy is superior especially in the setting of limited number of brain metastases. The availability of newer medical therapy that improves survival highlighted the importance of reducing long term radiation toxicity associated with WBRT. In this study, we aim to demonstrate the hippocampal sparing technique with whole brain and integrated simultaneous boost Materials and Methods: Planning data from 10 patients with 1-5 brain metastases treated with SRS were identified. Based on the contouring guideline from RTOG atlas, we identified and contoured the hippocampus with 5mm isocentric expansion to form the hippocampal avoidance structure. The plan was to deliver hippocampal sparing whole brain radiotherapy (HSWBRT) of 30 Gy in 10 fractions and simultaneous boost to metastatic lesions of 30 Gy in 10 fractions each. Results: The PTV, hippocampus and hippocampal avoidance volumes ranges between 1.00 - 39.00 cc., 2.50 - 5.30 cc and 26.47 - 36.30 cc respectively. The mean hippocampus dose for the HSWBRT and HSWBRT and SIB plans was 8.06 Gy and 12.47 respectively. The max dose of optic nerve, optic chiasm and brainstem were kept below acceptable range of 37.5 Gy. Conclusions: The findings from this dosimetric study demonstrated the feasibility and safety of treating limited brain metastases with HSWBRT and SIB. It is possible to achieve the best of both worlds by combining HSWBRT and SIB to achieve maximal local intracranial control while maintaining as low a dose as possible to the hippocampus thereby preserving memory and quality of life.

Dosimetric Comparison of Three-Dimensional Conformal, Intensity-Modulated Radiotherapy, Volumetric Modulated Arc Therapy, and Dynamic Conformal Arc Therapy Techniques in Prophylactic Cranial Irradiation

  • Ismail Faruk Durmus;Dursun Esitmez;Guner Ipek Arslan;Ayse Okumus
    • 한국의학물리학회지:의학물리
    • /
    • 제34권4호
    • /
    • pp.41-47
    • /
    • 2023
  • Purpose: This study aimed to dosimetrically compare the technique of three-dimensional conformal radiotherapy (3D CRT), which is a traditional prophylactic cranial irradiation method, and the intensity-modulated radiotherapy (IMRT) and volumetric modulated arc therapy (VMAT) techniques used in the last few decades with the dynamic conformal arc therapy (DCAT) technique. Methods: The 3D CRT, VMAT, IMRT, and DCAT plans were prepared with 25 Gy in 10 fractions in a Monaco planning system. The target volume and the critical organ doses were compared. A comparison of the body V2, V5, and V10 doses, monitor unit (MU), and beam on-time values was also performed. Results: In planned target volume of the brain (PTVBrain), the highest D99 dose value (P<0.001) and the most homogeneous (P=0.049) dose distribution according to the heterogeneity index were obtained using the VMAT technique. In contrast, the lowest values were obtained using the 3D CRT technique in the body V2, V5, and V10 doses. The MU values were the lowest when DCAT (P=0.001) was used. These values were 0.34% (P=0.256) lower with the 3D CRT technique, 66% (P=0.001) lower with IMRT, and 72% (P=0.001) lower with VMAT. The beam on-time values were the lowest with the 3D CRT planning (P<0.001), 3.8% (P=0.008) lower than DCAT, 65% (P=0.001) lower than VMAT planning, and 76% (P=0.001) lower than IMRT planning. Conclusions: Without sacrificing the homogeneous dose distribution and the critical organ doses in IMRTs, three to four times less treatment time, less low-dose volume, less leakage radiation, and less radiation scattering could be achieved when the DCAT technique is used similar to conventional methods. In short, DCAT, which is applicable in small target volumes, can also be successfully planned in large target volumes, such as the whole-brain.

MOSFET 선량계를 이용한 In-vivo 선량의 확인 (In-vivo Dose verification using MOSFET dosimeter)

  • 강대규;이광만
    • 센서학회지
    • /
    • 제15권2호
    • /
    • pp.102-105
    • /
    • 2006
  • In-vivo dosimetry is an essential tool of quality assurance programs in radiotherapy. The most commonly used techniques to verify dose are thermoluminescence dosimeter (TLD) and diode detectors. Metal oxide semiconductor field-effect transistor (MOSFET) has been recently proposed for using in radiation therapy with many advantages. The reproducibility, linearity, isotropy, dose rate dependence of the MOSFET dosimeter were studied and its availability was verified. Consequently the results can be used to improve therapeutic planning procedure and minimize treatment errors in radiotherapy.

Neck Node Bolus Technique in the Treatment of Nasopharyngeal Carcinoma with Intensity-modulated Radiotherapy

  • Phua, Chee Ee;Ung, Ngie Min;Tan, Boon Seang;Tan, Ai Lian;Eng, Kae Yann;Ng, Bong Seng
    • Asian Pacific Journal of Cancer Prevention
    • /
    • 제13권12호
    • /
    • pp.6133-6137
    • /
    • 2012
  • Purpose: To study the effect of bolus versus no bolus in the coverage of the nodal tumour volume with intensity-modulated radiotherapy (IMRT) for the treatment of nasopharyngeal carcinoma (NPC). Methods and Materials: This retrospective study used data from 5 consecutive patients with NPC who were treated with bolus for large neck nodes using IMRT from November 2011-January 2012 in our institute. All these patients were treated radically with IMRT according to our institution's protocol. Re-planning with IMRT without bolus for these patients with exactly the same target volumes were done for comparison. Comparison of the plans was done by comparing the V70 of PTV70-N, V66.5 of PTV70-N, V65.1 of PTV70-N and the surface dose of the PTV70-N. Results: The mean size of the largest diameter of the enlarged lymph nodes for the 5 patients was 3.9 cm. The mean distance of the GTV-N to the skin surface was 0.6 cm. The mean V70 of PTV70-N for the 5 patients showed an absolute advantage of 10.8% (92.4% vs. 81.6%) for the plan with bolus while the V66.5 of PTV70-N had an advantage of 8.1% (97.0% vs. 88.9%). The mean V65.1 also had an advantage of 7.1% (97.6% vs. 90.5%). The mean surface dose for the PTV70-N was also much higher at 61.1 Gy for the plans with bolus compared to only 23.5 Gy for the plans without bolus. Conclusion: Neck node bolus technique should be strongly considered in the treatment of NPC with enlarged lymph nodes treated with IMRT. It yields a superior dosimetry compared t o non-bolus plans with acceptable skin toxicity.

정위방사선치료 시 적분 생물학적 유효선량 및 방사선조사용적을 이용한 Total Arc Degree의 최적화 (Optimization of Total Arc Degree for Stereotactic Radiotherapy by Using Integral Biologically Effective Dose and Irradiated Volume)

  • 임도훈;이명자;전하정;김대용
    • Radiation Oncology Journal
    • /
    • 제19권2호
    • /
    • pp.199-204
    • /
    • 2001
  • 목적 : 정위방사선치료 시 정상 뇌 조직을 고선량의 방사선으로부터 최대한 보호하며 치료의 효율성을 높이기 위하여 치료 인자 중 콜리메이터의 크기와 arc 간 간격에 따른 이상적인 total arc degree (TAD) 값을 제시하고자 한다. 대상 및 방법 : XKnife-3 planning system을 사용하여 환자의 송과체 부위에 방사선 빔의 회전중심점을 위치시킨 후 12, 20, 30, 40, 50 그리고 60 mm 직경의 정위방사선치료용 원형 콜리메이터를 이용하여 각각의 콜리메이터 직경별로 TAD를 100, 200, 300, 400, 500, 600도, 그리고 arc 간 간격을 30도(6-arc system)와 45도(4-arc system)로 설정하여 방사선치료계획을 수립하였다. 치료계획을 통해 얻은 누적선량체적히스토그람을 이용하여 회전중심점 처방선량의 $50\%$ 이상 조사되는 정상 뇌의 용적$(V_{50})$ 및 적분 생물학적 유효선량(integral biologically effective dose)을 이용하여 각각의 TAD에 따른 방사선치료계획을 비교하였다. 결과 : TAD에 따른 $V_{50}$의 변화는 arc 간 각도가 30도인 경우에는 콜리메이터 직경과 관계없이 TAD가 증가할수록 감소하는 양상을 보였으나, 45도의 arc 간 각도에서는 400도의 TAD까지는 감소하다가 400도 이상의 TAD에서 $V_{50}$은 증가하거나 변화가 없었다. 적분 생물학적 유효선량 값의 변화는 arc 간 간격이 30도인 경우에는 콜리메이터의 직경에 관계없이 TAD가 증가함에 따라 미소하게 감소하는 양상을 보였다. arc 간 각도가 45도인 경우에는 콜리메이터 직경이 40 mm 이하에서는 TAD가 증가함에 따라 적분 생물학적 유효선량은 계속 감소하였으나, 50 mm와 60 mm 직경의 콜리메이터에서는 TAD가 400도까지는 감소하다가 500도 이상의 TAD에서는 증가하였다. 결론 : 정위방사선치료 시 400도 정도의 TAD를 사용하는 것은 300도 이하 혹은 500도 이상의 TAD를 사용하는 것 보다 치료 효과를 높이면서 치료계획과 치료 시 장비 및 인적 자원의 효율적인 운용을 기대할 수 있을 것으로 판단된다.

  • PDF