• Title/Summary/Keyword: radiology room

Search Result 186, Processing Time 0.023 seconds

Ultrashort Echo Time MRI (UTE-MRI) Quantifications of Cortical Bone Varied Significantly at Body Temperature Compared with Room Temperature

  • Jerban, Saeed;Szeverenyi, Nikolaus;Ma, Yajun;Guo, Tan;Namiranian, Behnam;To, Sarah;Jang, Hyungseok;Chang, Eric Y.;Du, Jiang
    • Investigative Magnetic Resonance Imaging
    • /
    • v.23 no.3
    • /
    • pp.202-209
    • /
    • 2019
  • Purpose: To investigate the temperature-based differences of cortical bone ultrashort echo time MRI (UTE-MRI) biomarkers between body and room temperatures. Investigations of ex vivo UTE-MRI techniques were performed mostly at room temperature however, it is noted that the MRI properties of cortical bone may differ in vivo due to the higher temperature which exists as a condition in the live body. Materials and Methods: Cortical bone specimens from fourteen donors ($63{\pm}21$ years old, 6 females and 8 males) were scanned on a 3T clinical scanner at body and room temperatures to perform T1, $T2^*$, inversion recovery UTE (IR-UTE) $T2^*$ measurements, and two-pool magnetization transfer (MT) modeling. Results: Single-component $T2^*$, $IR-T2^*$, short and long component $T2^*s$ from bi-component analysis, and T1 showed significantly higher values while the noted macromolecular fraction (MMF) from MT modeling showed significantly lower values at body temperature, as compared with room temperature. However, it is noted that the short component fraction (Frac1) showed higher values at body temperature. Conclusion: This study highlights the need for careful consideration of the temperature effects on MRI measurements, before extending a conclusion from ex vivo studies on cortical bone specimens to clinical in vivo studies. It is noted that the increased relaxation times at higher temperature was most likely due to an increased molecular motion. The T1 increase for the studied human bone specimens was noted as being significantly higher than the previously reported values for bovine cortical bone. The prevailing discipline notes that the increased relaxation times of the bound water likely resulted in a lower signal loss during data acquisition, which led to the incidence of a higher Frac1 at body temperature.

The Method of Improvement by Illuminance Measurement of the CT Scan Room in a General Hospital Radiology (종합병원 영상의학과 CT 검사실의 조도 측정에 의한 향상 방안)

  • Kweon, Dae-Cheol;Yang, Sung-Hwan;Kang, Young-Sig
    • Journal of the Korean Institute of Plant Engineering
    • /
    • v.23 no.4
    • /
    • pp.51-56
    • /
    • 2018
  • Computed tomography (CT) scan room in the department of radiology is very necessary to maintain pleasant and proper illuminance to relieve fatigue and inconvenience because it affects the work environment to the radiologist. Accordingly, this paper describes the method for measurement of illuminance that exposed to an environmental elements in a CT scan room of the hospital. Therefore, the purpose of this paper is to propose an optimal environment of CT scan room based on the measurement of illuminance. In addition, the 5 point method by KS C7612 was applied to measure the illuminance with illuminometer (Unfors xi light probe) in the CT scan room. In result of this paper, minimum value and maximum value of illuminance in the CT scan room was measured 212.7 lux and 354.8 lux, respectively. The illuminance of CT scan room was lower than KS A 3011. Finally, the work environment in CT scan room should provide higher illuminance for the comfortable environment of radiologists and patients.

A Study on the Effect of the Environmental Improvement in the Diagnostic Radiography Room on Patients (진단방사선과 검사실의 환경개선이 환자에게 미치는 영향에 관한 연구)

  • Kweon, Dae Cheol;Hong, Sung Man;Kim, Dong Sung;Park, Peom
    • Quality Improvement in Health Care
    • /
    • v.9 no.1
    • /
    • pp.90-100
    • /
    • 2002
  • Background : This study was attempted to provide us with basic data on how to environmental improvement with patients for examination, and to offer them better treatment. This study was performed to compare the patients, perception between before and after improvement in the diagnostic radiography room. Methods : The data was collected by interviewing 75 patients who underwent the radiography under the diagnostic radiology at Seoul National University Hospital in Korea. The interview ran from August 9 to October 18, 1999. Data were analyzed by percentage and paired t-test. SD(Semantic Differential) method was composed of adjective 13 words. Results : Patients were attending the elementary schools in the Seoul residents. There was no significant difference in kindness unkindness dimension and were significant differences in other dimensions. The mean score of response level to present room was 3.67 and that of improvement room was 2.16. Conclusions : The results of this study suggest a radiography room plan which is considering emotional aspect of children.

  • PDF

A study regarding measurements of bacterial contamination levels in radiology room within the department of radiological technology (영상의학과 촬영실에서의 세균 오염도 측정에 관한 연구)

  • Dong, Kyung-Rae;Cho, Young-Kuk;Ro, Sang-Ho
    • Proceedings of the Korea Contents Association Conference
    • /
    • 2009.05a
    • /
    • pp.1150-1158
    • /
    • 2009
  • Since equipment currently being used in the department of radiological technology comes into contact with patients carrying diseases, there inevitably will be the existence of pathogenic bacteria. Therefore, in order to increase the importance of using disinfectant in hospital infection precaution and the recognition of hospital infection management, comparisons were made by measuring the bacterial contamination levels in radiology room within the department of radiological technology and comparing the measurements with post disinfection levels. Disinfecting the rooms from detected bacteria was conducted with water, tissue cleaner, or 70% alcohol. When measuring bacterial contamination levels in radiology rooms, a variety of bacteria was detected. When disinfecting the interior of radiology rooms the effectiveness of destroying bacteria and preventing hospital infection was greatest when using 70% alcohol compared to water, tissue cleaner and ventilation. Therefore, there needs to be a development of a better antiseptic for destroying bacteria because there is a possibility for hospital medical equipment to be constantly contaminated. Efforts need to be made to prevent hospital infections and patient secondary infection by disinfecting and sterilizing equipment.

  • PDF

Stent graft treatment of an ilioenteric fistula secondary to radiotherapy: a case report

  • Jang, Joo Yeon;Jeon, Ung Bae;Kim, Jin Hyeok;Kim, Tae Un;Hwang, Jae Yeon;Ryu, Hwa Seong
    • Journal of Yeungnam Medical Science
    • /
    • v.39 no.1
    • /
    • pp.77-80
    • /
    • 2022
  • Fistulas between the arteries and the gastrointestinal tract are rare but can be fatal. We present a case of an ilioenteric fistula between the left external iliac artery and sigmoid colon caused by radiotherapy for cervical cancer, which was treated with endovascular management using a stent graft. A 38-year-old woman underwent concurrent chemoradiotherapy for cervical cancer recurrence. Approximately 9 months later, the patient suddenly developed hematochezia. On her first visit to the emergency room of our hospital, computed tomography (CT) images did not reveal extravasation of contrast media. However, 8 hours later, she revisited the emergency room because of massive hematochezia with a blood pressure of 40/20 mmHg and a heart rate of 150 beats per minute. At that time, CT images showed the presence of contrast media in almost the entire colon. The patient was referred to the angiography room at our hospital for emergency angiography. Inferior mesenteric arteriography did not reveal any source of bleeding. Pelvic arteriography showed contrast media extravasation from the left external iliac artery to the sigmoid colon; this was diagnosed as an ilioenteric fistula and treated with a stent graft. When the bleeding focus is not detected on visceral angiography despite massive arterial bleeding, pelvic arteriography is recommended, especially in patients with a history of pelvic surgery or radiotherapy.

A Study on the Guarantee of Learning Rights of Radiology Students in Nuclear Safety Act (원자력안전법에 대한 방사선학과 학생들의 학습권 보장에 관한 연구)

  • Lee, Bo-Woo
    • Journal of radiological science and technology
    • /
    • v.45 no.2
    • /
    • pp.159-164
    • /
    • 2022
  • The study developed a radiation dose measurement program in the radiology laboratory to measure how much exposure the students are exposed to during the radiology class, to request for the improvement and the revision of the current Nuclear Safety Act. The experimental program is shown in the following figure, and experiments were conducted to determine the degree of radiation exposure in the control room with a lead gown at a distance of 1 m, 2 m, and 1 m, and in a control room with a radiographic lead glass wall. The duration of the experiment was 3 months from April to June, when radiation imaging practice classes were conducted, and 128 hours of imaging practice per month were conducted. In order to find out the dose of radiation dose during radiology imaging practice class, the experiment was carried out from April to June for 3 months, and according to the program, the results of exposure dose were 0.34 mSv at 1 m distance, 0.01 mSv at shielding of lead gown at 1 m distance, 0.16 mSv at 2 m distance, and 0.01 mSv at control room with radiation lead glass wall. The exposure dose from the test results was much below the annual general public limit dose of 1 mSv. The restriction on the operation of the radiation equipment in the practice of the students is a regulation that infringes the right of students to learn, and amendments or exemptions of Nuclear Safety Act should be enacted to ensure that it does not violate the fundamental right to learn for students in radiology.

Compositional Qualification of Radiation Protection in Neutron Radiotherapy Room with KCCH Cyclotron (원자력병원(原子力病院) 싸이클로트론 중성자선(中性子線) 치료실(治療室)의 방사선(放射線) 방어(防禦)에 관한 총합적(總合的) 평가(評價))

  • Yoo, Seong-Yul;Cho, Chul-Koo;Koh, Kyoung-Hwan
    • Journal of Radiation Protection and Research
    • /
    • v.14 no.2
    • /
    • pp.45-50
    • /
    • 1989
  • Radiation exposure of the personnel in the neutron therapy facility of KCCH cyclotron neutron system is discussed. In neutron therapy room, medical personnel is exposed to photons of the remanent induced radioactivity from the isocentric gantry in which targets and collimators are mounted. The radiation level of the neutron therapy room of KCCH cyclotron was acceptable and it decreased immediately after beam off. Personal exposure measured by individual monitor was far less than permissible level.

  • PDF

A Study on Structural Shielding Design of Afterloading Therapy Room (강내치료실 차폐에 대한 고찰)

  • Yun, Suk-Rok;Kim, Myung-Ho;Shin, Dong-Oh
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.2 no.1
    • /
    • pp.31-40
    • /
    • 1987
  • In the case of designing a high dose rate remote controlled afterloading treatment room with existing hospital facilities. We must construct the effective protective barriers so as to reduce the primary and scattered radiation up to the maximum permissible dose level. It is difficult to reinforce the barrier thickness of the shielding requirements because of the limited space and the problem of the existing building structure at the surrounding area. Therefore we can reduce the intensity of primary radiation to the required degree at the location of interest with installing the appropriate I shaped Pb barriers between the radiation source and the shielding wall of the concrete. As a result, it was possible to reduce the intensity of the primary radiation below the M.P.D level by using additional Pb barriers instead of increasing thickness of concrete wall.

  • PDF

Infection Control and Management Strategy for COVID-19 in the Radiology Department: Focusing on Experiences from China

  • Qian Chen;Zi Yue Zu;Meng Di Jiang;Lingquan Lu;Guang Ming Lu;Long Jiang Zhang
    • Korean Journal of Radiology
    • /
    • v.21 no.7
    • /
    • pp.851-858
    • /
    • 2020
  • Coronavirus disease 2019 (COVID-19) is a new infectious disease rapidly spreading around the world, raising global public health concerns. Radiological examinations play a crucial role in the early diagnosis and follow-up of COVID-19. Cross infection among patients and radiographers can occur in radiology departments due to the close and frequent contact of radiographers with confirmed or potentially infected patients in a relatively confined room during radiological workflow. This article outlines our experience in the emergency management procedure and infection control of the radiology department during the COVID-19 outbreak.