THE VIDEODENSITOMETRIC ANALYSIS OF THE RADIOGRAPHIC DENSITY AND CONTRAST (Videodensitometry법을 이용한 X선사진의 흑화도와 대조도에 관한 연구)

  • Yoo Young Sun;Lee Sang Rae
    • Journal of Korean Academy of Oral and Maxillofacial Radiology
    • /
    • v.22 no.2
    • /
    • pp.293-303
    • /
    • 1992
  • Generally the patient's absorb dose and readability of radiograms are affected by the exposure time and kVp of which are related with the radiographic density and contrast The investigator carried studies to know the adequate level of exposure time and kVp to obtain the better readability of radiograms. In these studies dried human mandible with selfcuring acrylic resins attached with aluminum step wedge was used and readability of radiograms were compared with each other by videodensitometry among various combination sets of the exposure time, such as 5, 6, 8, 12, 15, 19, 24, 30, 38, 48 and 60, and varing level of kVp, such as 60, 65, 70, 80 and 90 respectively. The obtained results were as follows: 1. As exposure time and kVp were increased, radiographic density of radiograms was increased. 2. The subject contrast was increased where aluminum step wedge was thin and reduced in the reversed condition. At the thin aluminum step wedge, subject contrast was increased at the condition of lower kilovoltage than that of higher kilovoltage. 3. In the case of non-constant radiographic density, the radiographic contrast was reduced with the increment kilovoltage. The radiographic contrast was increased in the lower kilovoltage with the longer exposure time and the higher kilovoltage with the shorter exposure time. 4. At the condition of short exposure time, better readability of each reading item was obtained with the increment of the kilovoltage but at the opposite condition increasing exposure time worsened readability of radiograms. Since X-ray machine in the current dental clinics is fixed between the range of 60-70kVp and 10mA, good radiograms can be obtained by varied exposure time. But according to the conclusion of these studies, better radiograms can be obtained by using filtered high kVp and then the absorb dose to patient and exposure time can be reduced.

  • PDF

EXPERIMENTAL STUDY OF INFLUENCE ON RADIOGRAPHIC DENSITY AND CONTRAST BY THE CHANGE OF KILOVOLTAGE AND EXPOSURE TIME (관전압과 X선노출시간의 변화가 X선사진의 흑화도와 대조도에 미치는 영향에 관한 실험적 연구)

  • Lee Byeong Do;Lee Sang Rae
    • Journal of Korean Academy of Oral and Maxillofacial Radiology
    • /
    • v.20 no.1
    • /
    • pp.113-124
    • /
    • 1990
  • For the study of the influence of kilovoltage and exposure time on radiographic density and contrast, we measured radiographic density of aluminum step wedge which composed of contiguous 8 steps wedges of 2-16㎜ thickness with densitometer. Aluminum step wedge was radiographed on Kodak ultraspeed DF-58 and Ektaspeed EP-21 film with range of 60-90 kVp and 5-60 impulse and subject contrast of aluminum step wedge with constant radiographic density and image contrast percentage without radiographic density was evaluated. Then we evaluated the film quality of teeth and their surrounding structure according to the change of kVp and exposure time by score rating method. The obtained results were as follows: 1. Radiographic density was related to the change of kilovoltage, especially in increased exposure time. 2. With constant radiographic density, subject contrast of thin aluminum step wedges was greater in low kilovolt age than high kilovoltage, but kilovolt age had not great influence on subject contrast of thick aluminum step wedge. On the other hand, radiographic density difference between 2mm and 16mm aluminum step wedge was decreased according to in- creasing kilovoltage. 3. Without constant radiographic density, image contrast percentage was decreased with increasing kilovoltage, but was not related with the change of exposure time. 4. Radiographic contrast of teeth and their surrounding structure which was taken with the range of 60-90 kVp and 6-30 impulse had not great influence on film quality.

  • PDF

The effects of image acquisition control of digital X-ray system on radiodensity quantification

  • Seong, Wook-Jin;Kim, Hyeon-Cheol;Jeong, Soocheol;Heo, Youngcheul;Song, Woo-Bin;Ahmad, Mansur
    • Restorative Dentistry and Endodontics
    • /
    • v.38 no.3
    • /
    • pp.146-153
    • /
    • 2013
  • Objectives: Aluminum step wedge (ASW) equivalent radiodensity (eRD) has been used to quantify restorative material's radiodensity. The aim of this study was to evaluate the effects of image acquisition control (IAC) of a digital X-ray system on the radiodensity quantification under different exposure time settings. Materials and Methods: Three 1-mm thick restorative material samples with various opacities were prepared. Samples were radiographed alongside an ASW using one of three digital radiographic modes (linear mapping (L), nonlinear mapping (N), and nonlinear mapping and automatic exposure control activated (E)) under 3 exposure time settings (underexposure, normal-exposure, and overexposure). The ASW eRD of restorative materials, attenuation coefficients and contrasts of ASW, and the correlation coefficient of linear relationship between logarithms of gray-scale value and thicknesses of ASW were compared under 9 conditions. Results: The ASW eRD measurements of restorative materials by three digital radiographic modes were statistically different (p = 0.049) but clinically similar. The relationship between logarithms of background corrected grey scale value and thickness of ASW was highly linear but attenuation coefficients and contrasts varied significantly among 3 radiographic modes. Varying exposure times did not affect ASW eRD significantly. Conclusions: Even though different digital radiographic modes induced large variation on attenuation of coefficient and contrast of ASW, E mode improved diagnostic quality of the image significantly under the underexposure condition by improving contrasts, while maintaining ASW eRDs of restorative materials similar. Under the condition of this study, underexposure time may be acceptable clinically with digital X-ray system using automatic gain control that reduces radiation exposure for patient.

Investigation on Evaluation of Exposure Dose & Radiographic Technique for Diagnostic X-ray Examination (X선검진시의 촬영조건과 피폭선량 평가에 대한 조사)

  • Kim Kyung Hwan;Lee Jin Kyu
    • Journal of The Korean Radiological Technologist Association
    • /
    • v.27 no.2
    • /
    • pp.229-251
    • /
    • 2001
  • At the investigations with 200 institutes for analysis of factor associated with radiographic conditions reduction of patient exposure dose during X-ray diagnosis, 170 institutes or $85\%$ answered. For estimation of exposure dose the entrance

  • PDF

Attitude of the Korean dentists towards radiation safety and selection criteria

  • Lee, Byung-Do;Ludlow, John B.
    • Imaging Science in Dentistry
    • /
    • v.43 no.3
    • /
    • pp.179-184
    • /
    • 2013
  • Purpose: X-ray exposure should be clinically justified and each exposure should be expected to give patients benefits. Since dental radiographic examination is one of the most frequent radiological procedures, radiation hazard becomes an important public health concern. The purpose of this study was to investigate the attitude of Korean dentists about radiation safety and use of criteria for selecting the frequency and type of radiographic examinations. Materials and Methods: The study included 267 Korean dentists. Five questions related to radiation safety were asked of each of them. These questions were about factors associated with radiation protection of patients and operators including the use of radiographic selection criteria for intraoral radiographic procedures. Results: The frequency of prescription of routine radiographic examination (an example is a panoramic radiograph for screening process for occult disease) was 34.1%, while that of selective radiography was 64.0%. Dentists' discussion of radiation risk and benefit with patients was infrequent. More than half of the operators held the image receptor by themselves during intraoral radiographic examinations. Lead apron/thyroid collars for patient protection were used by fewer than 22% of dental offices. Rectangular collimation was utilized by fewer than 15% of dental offices. Conclusion: The majority of Korean dentists in the study did not practice radiation protection procedures which would be required to minimize exposure to unnecessary radiation for patients and dental professionals. Mandatory continuing professional education in radiation safety and development of Korean radiographic selection criteria is recommended.

Automatic Exposure Control Performance Evaluation of Digital Radiographic Imaging System by Manufacturer Using Coins (동전을 이용한 제조사 별 디지털 방사선 영상 시스템의 자동노출제어 성능 평가)

  • Lim, Se-Hun;Seoung, Youl-Hun
    • Journal of radiological science and technology
    • /
    • v.45 no.1
    • /
    • pp.1-9
    • /
    • 2022
  • In this study, we proposed an image quality control for an automatic exposure control (AEC) of digital radiographic imaging system and tried to analyze the performance of the AEC by various manufacturer. The subjects of the experiment were analyzed for the AEC image quality evaluation using digital radiation generators from four manufacturer such as PHILIPS, GE Healthcare, SAMSUNG Healthcare, DK Medical Solution. We used as materials for the implementation of the image quality evaluation by coins (500 won, KOMSCO, Korea). This study evaluated the performance evaluation of the AEC as image quality and exposure dose (Milliampere-seconds; mAs). The image quality evaluation was tried visual assessment by two radiologic technologists and contrast to noise (CNR) by ImageJ. The exposure dose investigated mAs on digital radiation generators. The radiographic coin images acquired 360 images based on change in the control factors of the AEC, which were kVp, the consistency of field configuration and dominant zone, sensitivity and density. As a result, there was a significant difference in the AEC performance between manufacturer. The CNR by the AEC for each manufacturer showed a difference of up to about 1.9 times. The exposed tube current by the AEC for each manufacturer showed a difference of up to about 5.8 times. It is expected that our proposed evaluation method using coins could be applied as the AEC performance evaluation method in the future.

The survey of the surface doses of the dental x-ray machines (치과 방사선 촬영기의 표면선량 변화)

  • Lee Jae-Seo;Kang Byung-Cheol;Yoon Suk-Ja
    • Imaging Science in Dentistry
    • /
    • v.35 no.2
    • /
    • pp.87-90
    • /
    • 2005
  • Purpose : The purpose of this study was to investigate variability of doses with same exposure parameters and evaluate radiographic density according to the variability of doses. Materials and methods Twenty-eight MAX-GLS (Shinhung Co, Seoul, Korea), twenty-one D-60-5 (DongSeo Med, Seoul, Korea), and eleven REX-601 (Yoshida Dental MFG, Tokyo, Japan) dental x-ray machines were selected for this study Surface doses were measured under selected combinations of tube voltage, tube current, exposure time, and constant distance 42 cm from the focal spot to the surface of the Multi-O-meter (Unfors Instruments, Billdal, Sweden). Radiographic densities were measured on the films at maximum, minimum and mean surface doses of each brand of x-ray units. Results With MAX-GLS, the maximum surface doses were thirteen to fourteen times as much as the minimum surface doses. With D-60-S, the maximum surface doses were three to eight times as much as the minimum surface doses. With REX-601, the maximum surface doses were six to ten times as much as the minimum surface doses. The differences in radiographic densities among maximum, mean, and minimum doses were significant (p<0.01). Conclusion : The surface exposure doses of each x-ray machine at the same exposure parameters were different within the same manufacturer's machines.

  • PDF

Current status of dental intraoral imaging devices and radiographic safety management (치과 구내촬영 장비 현황과 방사선 안전 관리 실태 연구)

  • Kang, Eun-Ju;Hyeong, Ju-Hee
    • Journal of Korean society of Dental Hygiene
    • /
    • v.16 no.2
    • /
    • pp.205-214
    • /
    • 2016
  • Objectives: The purpose of the study is to investigate the current status and radiographic safety management in Korea. Methods: A self-reported questionnaire was completed by 200 dental hygienists in Jeonbuk province from September 1, 2014 and October 31, 2014. The questionnaire consisted of general characteristics of the subjects, radiation knowledge, radiation safety management, and radiation exposure anxiety. Data were analyzed using SPSS 18.0 program. Results: Duration of clinical experience(r=0.142) and number of daily radiation shot(r=0.145) showed a positive correlation to radiation safety management, and a nrgative correlation to use of intraoral films and digital devices(r=-0.587). A logistic regression analysis was performed in order to evaluate the influence on radiography knowledge. The results showed that the factors had significant influences on the age group over 41 years old(OR 7.25; 95% CI 1.30-40.43) and those who took a position above team leader(OR 0.23; 95% CI 0.59-0.90). Conclusions: It is very important to have the safety management toward dental intraoral imaging and radiograpgic shot in the dental hygienists. Continuous efforts should be emphasized on radiographic safety management and behavior.

Review of Radiographic Selection Criteria : The update is necessary (방사선사진 검사 선택기준에 대한 고찰)

  • Lee, Byung-Do
    • The Journal of the Korean dental association
    • /
    • v.51 no.1
    • /
    • pp.39-45
    • /
    • 2013
  • Radiographic examinations are used to discover and define the type and extent of disease in many clinical situations. Currently, it is common for dental patients to receive dental radiographic examinations on a routine schedule with little variation in spite of different patient signs and symptoms. Such routine scheduling of radiographic examinations may result in unnecessary patient exposure. There is also the possibility of under-utilization of radiography; this can result in inadequate or excessively delayed diagnosis. Patient selection criteria are descriptions of clinical conditions derived from patient signs, symptoms and history that identify patients who are likely to benefit from a particular radiographic examination. It makes possible making individual decisions based on history, clinical examination and risk factors. The radiographic selection criteria of dentistry have been revised in accordance with recent guidelines and peer-reviewed research in USA and Europe, but the studies of these subjects are not sufficient in our nation. In this review article, the relating factors and update necessity of radiographic selection criteria are discussed.

COMPARATIVE STUDY OF DIRECT DIGITAL RADIOGRAPHIC SYSTEM WITH FILM-BASED DIGITAL IMAGING SYSTEM USING EKTASPEED AND EKTASPEED PLUS FILM (직접 디지탈 방사선 촬영시스템과 Ektaspeed 및 Ektaspeed Plus 필름을 이용한 방사선 사진용 디지탈 영상시스템과의 비교 연구)

  • Do Jung-Joo;Kim Eun-Kyung
    • Journal of Korean Academy of Oral and Maxillofacial Radiology
    • /
    • v.25 no.1
    • /
    • pp.51-70
    • /
    • 1995
  • The purpose of this investigation was to compare the direct digital radiographic system with film-based digital imaging system using Ektaspeed and Ektaspeed Plus film with respect to image characteristics and detectability and evaluate the sensor noise with the use of subtraction method. Direct digital radiographic system which used was Sens-A-Ray system(Regam Medical Systems, Sundsvall, Sweden) and film-based digital imaging system was composed of Macintosh II ci computer, high resolution Sony XC-77 CCD camera and intraoral x-ray film(Kodak Ektaspeed film, Kodak Ektaspeed Plus film). Images were taken by using CCD sensor of Sens-A-Ray system, Ektaspeed film and Ektaspeed Plus film with variable exposure time(0.06s, 0.1s, 0.16s, 0.2s, 0.3s, 0.4s, 0.5s, 0.6s, O.8s, LOs), 5 times at each exposure time. And then ektaspeed films and ektaspeed plus films were digitized using CCD camera. Image groups were divided into 3 groups; Sens-A-Ray group(direct digital radiographic system), Ektaspeed group and Ektaspeed Plus group (film-based digital imaging system) They were assessed by the following three aspects; image density, image contrast and detectability and sensor noise of Sens-A-Ray system was also evaluated. The results were as follow : 1. S group showed higher density than E , EP group except at the low exposure time(p<0.01). 2. S group showed higher contrast than E,EP group except at the high exposure time(p<0.01). 3. All groups showed good detectability at the each proper exposure time. Lowest exposure time which shows maximum detectability in S,EP group(0.5s) was lower than that in E group(0.6s). 4. Sensor noise of Sens-A-Ray system generally increased according to exposure time. On the basis of the above results, it was considered that Sens-A-Ray system could show higher speed, higher contrast than Ektaspeed, Ektaspeed Plus film except at too high and low exposure time and the same detectability as the conventional intraoral film.

  • PDF