• 제목/요약/키워드: radio frequency spectrum

검색결과 369건 처리시간 0.028초

A Modified Delay and Doppler Profiler based ICI Canceling OFDM Receiver for Underwater Multi-path Doppler Channel

  • Catherine Akioya;Shiho Oshiro;Hiromasa Yamada;Tomohisa Wada
    • International Journal of Computer Science & Network Security
    • /
    • 제23권7호
    • /
    • pp.1-8
    • /
    • 2023
  • An Orthogonal Frequency Division Multiplexing (OFDM) based wireless communication system has drawn wide attention for its high transmission rate and high spectrum efficiency in not only radio but also Underwater Acoustic (UWA) applications. Because of the narrow sub-carrier spacing of OFDM, orthogonality between sub-carriers is easily affected by Doppler effect caused by the movement of transmitter or receiver. Previously, Doppler compensation signal processing algorithm for Desired propagation path was proposed. However, other Doppler shifts caused by delayed Undesired signal arriving from different directions cannot be perfectly compensated. Then Receiver Bit Error Rate (BER) is degraded by Inter-Carrier-Interference (ICI) caused in the case of Multi-path Doppler channel. To mitigate the ICI effect, a modified Delay and Doppler Profiler (mDDP), which estimates not only attenuation, relative delay and Doppler shift but also sampling clock shift of each multi-path component, is proposed. Based on the outputs of mDDP, an ICI canceling multi-tap equalizer is also proposed. Computer simulated performances of one-tap equalizer with the conventional Time domain linear interpolated Channel Transfer Function (CTF) estimator, multi-tap equalizer based on mDDP are compared. According to the simulation results, BER improvement has been observed. Especially, in the condition of 16QAM modulation, transmitting vessel speed of 6m/s, two-path multipath channel with direct path and ocean surface reflection path; more than one order of magnitude BER reduction has been observed at CNR=30dB.

임상용 MR에서 pH 측정을 위한 동물 실험용 $^1H-^{31}P$ RF 코일 개발 (Development of $^1H-^{31}P$ Animal RF Coil for pH Measurement Using a Clinical MR Scanner)

  • 김은주;김대홍;이상우;허단;이영한;서진석
    • Investigative Magnetic Resonance Imaging
    • /
    • 제18권1호
    • /
    • pp.52-58
    • /
    • 2014
  • 목적: 임상용 MRI에서 마우스 종양의 pH 측정을 위한 $^1H-^{31}P$ RF 코일 시스템을 개발하고 팬텀을 이용하여 pH 값의 정확도를 시험하고자 한다. 대상과 방법: 마우스 종양 연구를 위한 표면형 $^1H$$^{31}P$ radio frequency (RF) 코일을 개발하였다. 두 코일을 서로 수직이 되도록 설치하여 두 코일간의 상호인덕턴스를 0으로 하였다. 다양한 pH 값을 가진 팬텀으로부터 $^{31}P$ MR 스펙트럼을 얻어 Henderson-Hasselbalch equation을 이용하여 pH를 구하였다. $^{31}P$ 스펙트럼으로부터 얻은 pH값은 pH meter를 사용하여 직접 구한 pH값과 비교한다. 결과: $^1H-^{31}P$ RF 코일 상호간 coil coupling (S12)은 각각 -73.0, -62.3 dB로 충분히 분리 되었다. 균일한 팬텀으로부터 얻은 $^1H$ 영상의 signal-to-noise ratio (SNR)는 약 300 이상이며, in vivo 고해상도 마우스 영상을 얻을 수 있었다. $^1H$ 신호가 분리된 $^{31}P$ MR 스펙트럼으로부터 얻은 pH값은 pH meter로 직접 측정하여 얻은 값과 약 97% 상관관계를 가졌다. 결론: 본 연구에서 개발한 임상 MRI 장비용 $^1H-^{31}P$ RF 코일 시스템으로부터 정확한 pH를 구할 수 있었다. 본 코일 시스템은 31P 이외의 다른 핵 MRS 혹은 MRI에 적용 가능할 것으로 기대된다.

지구정지궤도의 사적 거래의 국제법상 지위에 관한 연구 (Legal status of Priave Transaction Regarding the Geostationary Satellite Orbit)

  • 신홍균
    • 항공우주정책ㆍ법학회지
    • /
    • 제29권2호
    • /
    • pp.239-272
    • /
    • 2014
  • 지구정지궤도는 위성통신과 방송을 위한 필수요소로서 ITU 체제가 그 관리의 중심이다. ITU체제는 지구정지궤도를 이용하고자 하는 주관청의 사전신청 및 조정 의무를 규정하고 있으며, ITU 사무국과 RRB는 등록원부 등재 및 삭제를 통해서 정지궤도 이용권을 관리하고 있다. 등록원부에 등재된 위성망 정보는 관련 주관청과의 조정의 결과에 따라서 그 지위가 달라진다. ITU 무선규칙은 위성망 정보를 등재한 주관청이 실제로 위성을 운용하는가의 여부에 따라서 등재정보가 삭제 또는 변경되도록 하여 지구정지궤도가 필요한 주관청이 실질적으로 사용할 기회를 보장하고 있다. 그러나 위성망을 신청하는 주관청 국가의 국적과 지구정지궤도에서 실제로 운용되는 인공위성의 국적이 같아야 한다는 규정이 없으며, 또한 위성망을 신청한 주관청 국가와 인공위성간의 연결관계에 관한 규정도 없고, 주관청과 위성망 소유 기업간의 연결 관계에 관한 규정도 없다. 이러한 상황에서 지구정지궤도를 둘러싼 분쟁은 사실상 주관청만이 아니라 기업이 등장하는 조정을 통해서 해결되고 있다. 그 결과는 위성 궤도를 거래하는 사실상의 이차 시장의 등장이다. 이차 시장의 존재는 기존의 ITU 무선규칙 및 사무국과 RRB의 역할에 따른 제도적 틀의 한계를 입증한다. 예컨대 RRB는 제13.6조를 적용하지 않기로 결정하고, 당사자간의 조정을 촉구하는 것으로 자신의 업무를 한정한 바 있고, 주관청간의 위성망 거래가 합법임을 사실상 인정하고 있다. ITU의 무선규칙상 또한 RRB의 방침상 인공위성과 궤도의 그러한 거래는 위법이 아니다. 무궁화위성 3호의 국적이 대한민국이더라도 홍콩 소재 기업이 다른 주관청과 합의하여 그 주관청 명의의 위성망 신청하에 무궁화 위성 3호를 사용하고 있다의 증거로 사용할 수 있다. 무궁화 위성 3호의 매각이 국내법 위반이어서 매각계약 자체가 무효라 하더라도 마찬가지이다. 이제 동경 116도의 Ka 밴드 이용권은 ITU가 주관하는 분양시장이 아니라 ITU가 등기소 역할만을 하는 장외시장에 나온 매물이다.

Detection of short-term flux variability and intraday variability in polarized emission at millimeter-wavelength from S5 0716+714

  • Lee, Jeewon;Sohn, Bong Won;Byun, Do-Young;Lee, Jeong Ae;Lee, Sang Sung;Kang, Sincheol;Kim, Sungsoo S.
    • 천문학회보
    • /
    • 제41권2호
    • /
    • pp.33.1-33.1
    • /
    • 2016
  • We report detection of short-term flux variability in multi-epoch observations and intraday variability in polarized emission at millimeter-wavelength from S5 0716+714 using Korean VLBI Network (KVN) radio telescopes. Over the whole observation epochs, the source shows significant inter-month variations at K- and Q-band with modulation indices of 19% at K-band and 36% at Q-band. In each epoch, the source shows monotonic flux increase in Epoch 1 and 3, and monotonic flux decrease in Epoch 2 and 4. We found an inverted spectrum with mean spectral indices of -0.57 in Epoch 1 and -0.15 in Epoch. On the contrary, we found relatively steep indices of 0.24 and 0.17 in Epoch 2 and Epoch 4, respectively. In the study of intraday variability of polarization, we found significant variations in the degree of linear polarization at 86 GHz, and in polarization angle at 43 and 86 GHz during ~10 h. The spectrum of the source is quite flat with spectral indices of -0.07 to 0.07 at 22-43 GHz and -0.23 to 0.04 at 43-86 GHz. The measured degree of the linear polarization ranges from 2.3% to 3.3 % at 22 GHz, from 0.9% to 2.2 % at 43 GHz and from 0.4 % to 4.0 % at 86 GHz, yielding prominent variations at 86 GHz over 4-5 h. The linear polarization angle is in the range of 4 to $12^{\circ}$ at 22 GHz, -39 to $81^{\circ}$ at 43 GHz, and 66 to 119 at 86 GHz with a maximum rotation of $110^{\circ}$ at 43 GHz over ~4 h. We estimated the Faraday rotation measures (RM) ranging from -9200 to 6300 rad m-2 between 22 and 43 GHz, and from -71000 to 7300 rad m-2 between 43 and 86 GHz, respectively. The frequency dependency of RM was investigated, yielding a mean power-law index, a, of 2.0. This implies that the polarized emission from S5 0716+714 at 22-86 GHz moves through a Faraday screen in or near the jet of the source.

  • PDF

다중 증폭 회로를 이용한 높은 선형 특성을 갖는 광대역 능동 안테나 설계 (Design of a Highly Linear Broadband Active Antenna Using a Multi-Stage Amplifier)

  • 이철수;정근석;백정기
    • 한국전자파학회논문지
    • /
    • 제19권11호
    • /
    • pp.1193-1203
    • /
    • 2008
  • 능동 안테나는 수동 안테나에 비하여 소형으로 광대역 특성 및 높은 이득을 얻을 수 있으나, 잡음 및 불요파 신호가 발생되는 단점이 있다. 또한, 수신 시스템의 초단부에 위치하므로, 고감도 수신 시스템을 위하여 불요파 신호 특성이 좋아야 한다. 본 연구에서는 출력단 P1dB가 3 dBm 이상이고 $100{\sim}500\;MHz$에서 동작하며, 실환경에서 높은 선형 특성을 갖는 능동 안테나를 개발하였다. 이를 위하여 공통 드레인 FET와 2단 BJT의 능동 회로를 구성하였고, ADS를 이용하여 능동 안테나를 설계하였다. 제작된 능동 안테나의 평균 이득, 평균 잡음 지수, OIP3, VSWR 및 P1dB는 각각 9.7 dBi, 10 dB, 14 dBm, 1.7:1 및 3 dBm으로 설계치와 잘 일치하였다. 도심 인근지역에서 측정된 수신 스펙트럼 특성은 설계된 능동 안테나가 CS 구조를 갖는 참고문헌 [9]의 안테나보다 불요파 신호 특성이 약 $10{\sim}30\;dB$가 개선되어 방송 및 상용 신호와 혼재된 상태에서 신호 세기가 약한 미지의 신호를 검출하기 위한 고감도 수신 시스템에 적용할 수 있음을 보였다.

Use of Unmanned Aerial Vehicle for Multi-temporal Monitoring of Soybean Vegetation Fraction

  • Yun, Hee Sup;Park, Soo Hyun;Kim, Hak-Jin;Lee, Wonsuk Daniel;Lee, Kyung Do;Hong, Suk Young;Jung, Gun Ho
    • Journal of Biosystems Engineering
    • /
    • 제41권2호
    • /
    • pp.126-137
    • /
    • 2016
  • Purpose: The overall objective of this study was to evaluate the vegetation fraction of soybeans, grown under different cropping conditions using an unmanned aerial vehicle (UAV) equipped with a red, green, and blue (RGB) camera. Methods: Test plots were prepared based on different cropping treatments, i.e., soybean single-cropping, with and without herbicide application and soybean and barley-cover cropping, with and without herbicide application. The UAV flights were manually controlled using a remote flight controller on the ground, with 2.4 GHz radio frequency communication. For image pre-processing, the acquired images were pre-treated and georeferenced using a fisheye distortion removal function, and ground control points were collected using Google Maps. Tarpaulin panels of different colors were used to calibrate the multi-temporal images by converting the RGB digital number values into the RGB reflectance spectrum, utilizing a linear regression method. Excess Green (ExG) vegetation indices for each of the test plots were compared with the M-statistic method in order to quantitatively evaluate the greenness of soybean fields under different cropping systems. Results: The reflectance calibration methods used in the study showed high coefficients of determination, ranging from 0.8 to 0.9, indicating the feasibility of a linear regression fitting method for monitoring multi-temporal RGB images of soybean fields. As expected, the ExG vegetation indices changed according to different soybean growth stages, showing clear differences among the test plots with different cropping treatments in the early season of < 60 days after sowing (DAS). With the M-statistic method, the test plots under different treatments could be discriminated in the early seasons of <41 DAS, showing a value of M > 1. Conclusion: Therefore, multi-temporal images obtained with an UAV and a RGB camera could be applied for quantifying overall vegetation fractions and crop growth status, and this information could contribute to determine proper treatments for the vegetation fraction.

사용자 위치기반 홈오토메이션 서비스 기술 개발에 관한 연구 (A Study on the Technology Development of User-based Home Automation Service)

  • 이중기;이영석
    • 한국산학기술학회논문지
    • /
    • 제18권3호
    • /
    • pp.327-332
    • /
    • 2017
  • IoT 기술이 발전함에 따라 사용자의 이동성 및 정체성을 확인하기 위한 위치 기반 서비스(Location Based Service)에 대한 수요가 증가되고 있다. 초기의 LBS 시스템은 GPS(Global Positioning System) 위성에서 보내오는 신호의 위상을 측정하거나 반송파 신호의 코드를 추적하여 위성까지의 거리를 측정함으로써 위치정보를 확인하는 기술이 주로 사용되었다. 그러나 GPS위성을 사용하는 방식은 실내에서는 위성 신호의 수신이 어렵기 때문에 그 효용성이 떨어진다. 따라서 실내 환경에서 활용할 수 있는 위치인식기술을 위해 UWB, RFID, Zigbee 등과 같은 무선 통신 시스템에 관한 연구가 활발히 진행되고 있다. 이에 본 논문에서는 저전력 기반의 위치 인식을 위한 IEEE 802.15.4a의 표준을 활용하여 CSS를 위한 2.45GHz 대역과 UWB를 위한 3.1~10.6GHz대역 및 250-750 MHz대역의 주파수 대역을 포함을 하는 LBS 시스템을 설계하였다. 그 결과로서 2.45GHz ISM RF 트랜시버와 Ranging 기능을 하드웨어로 구현하여 0dBm의 출력파워를 갖음을 확인하였다.

미국의 상업적 우주활동에 대한 규제개혁 정책 (U.S. Commercial Space Regulatory Reform Policy)

  • 권희석;이진호;이은정
    • 한국항공우주학회지
    • /
    • 제46권12호
    • /
    • pp.1056-1069
    • /
    • 2018
  • 미 트럼프 행정부는 2018년 5월 24일 상업적 우주활동을 촉진하기 위한 규제개혁방향을 담은 우주정책명령 SPD-2(Space Policy Directive-2)를 발표하고, 뒤이어 6월 18일 우주상황 관리 정책에 관한 행정명령 SPD-3를 발표했다. 이 행정명령은 주요 우주 분야에 대한 개혁조치를 담고 있는데, 이 정책은 2017년 6월 재구성된 국가우주위원회(National Space Council: NSC)가 성안한 개혁 권고안을 대통령이 승인한 것으로 연방정부의 강력한 개혁추진을 위한 가이던스를 제공한다. 상업우주활동개혁정책은 앞서 2017년 12월 18일 발표된 국가안보전략(National Security Strategy)의 큰 틀에서 경제적 번영과 국가안보를 동시에 달성하기 위한 노력으로 이해할 수 있다. 상업적 우주활동을 촉진함으로써 미국의 국익을 달성하고자 하는 미국의 정책과 입법은 우주활동을 규율하는 우주조약을 위반한다는 우려와 논란을 불러일으킬 수 있다. 이에 국제사회는 미국의 상업우주개혁정책에서 노정되는 법적 쟁점에 대한 국제적 논의를 통해 우주기술의 발전과 상업화 진전에 맞는 보편적 국제 규범을 형성하기 위한 노력을 가속화해야 한다.

High Resolution HC$_3$N Observations toward the Central Region of Sagittarius B2

  • H.S-Ching;Oh, M.ishi;M.Morimoto
    • 한국우주과학회:학술대회논문집(한국우주과학회보)
    • /
    • 한국우주과학회 1993년도 한국우주과학회보 제2권2호
    • /
    • pp.17-17
    • /
    • 1993
  • The wall shear stress in the vicinity of end-to end anastomoses under steady flow conditions was measured using a flush-mounted hot-film anemometer(FMHFA) probe. The experimental measurements were in good agreement with numerical results except in flow with low Reynolds numbers. The wall shear stress increased proximal to the anastomosis in flow from the Penrose tubing (simulating an artery) to the PTFE: graft. In flow from the PTFE graft to the Penrose tubing, low wall shear stress was observed distal to the anastomosis. Abnormal distributions of wall shear stress in the vicinity of the anastomosis, resulting from the compliance mismatch between the graft and the host artery, might be an important factor of ANFH formation and the graft failure. The present study suggests a correlation between regions of the low wall shear stress and the development of anastomotic neointimal fibrous hyperplasia(ANPH) in end-to-end anastomoses. 30523 T00401030523 ^x Air pressure decay(APD) rate and ultrafiltration rate(UFR) tests were performed on new and saline rinsed dialyzers as well as those roused in patients several times. C-DAK 4000 (Cordis Dow) and CF IS-11 (Baxter Travenol) reused dialyzers obtained from the dialysis clinic were used in the present study. The new dialyzers exhibited a relatively flat APD, whereas saline rinsed and reused dialyzers showed considerable amount of decay. C-DAH dialyzers had a larger APD(11.70${\pm}$1.32mmHg/min)compared to CF dialyzers(4.32${\pm}$0.55mmHg/min)(p<0.05). However, there was no observable difference in the UFR between the two dialyzers. Neither APD nor UFR showed any significant increase with an increasing number of reuses for up to more than 20reuses. A substantial number of failures observed in APD(larger than 20mmHe/min)on the reused dialyzers(2 out of 40 CP and S out 26 C-DAK) were attributed to the Possible damage on the fibers. The CF 15-11 HFDs which failed APD test did not show changes in the UFR compared to normal dialyzers indicating that APD is a more sensitive test than UFR test to evaluate the integrity of the fibers. 30527 T00401030527 ^x For quantitative measurement of reflected light from a clinical diagnostic strip, a prototype old reflectance photometer was designed. The strip loader and cassette were made to obtain more accurate reflectance parameters. The strip was illuminated at 45˚c through optical fiber and the intensity of reflected light was determined at rectanguLat angle using a photodiode. The kubelka-munk coefficient and reflection optical density were determined ar four different wavelengths(500,550,570 and 610nm) for blood glucose strip. For higher concentration than 300mg/41 about glucose, a saturation state of abforbance was observed at 500,550 and 570nm. The correlation between glucose concentration and parameters was the best at 610nm. 30535 T00401030535 ^x Radiation-induced fibrosarcoma tumors were grown on the flanks of C3H mice. The mice were divided into two groups. One group was injected with Photofrin II, intravenously (2.5mg/kg body weight). The other group received no Photofrin II. Mice from both groups were irradialed for approximately 15 minutes at 100,300, or 500 mW/cm2 with the argon (488nm/514.5 nm), dye(628nm) and gold vapor (pulsed 628 nm) laser light. A photosensitizer behaved as an added absorber. Under our experimental conditions, the presence of Photolfrin II increased surface temperature by at least 40% and the temperature rise due to 300 mW/cm2 irradiation exceeded values for hyperthermia. Light and temperature distributions with depth were estimated by a computer model. The model demonstrated the influence of wavelength on the thermal process and proved to be a valuable tool to investigate internal temperature rise. 30536 T00401030536 ^x We investigated the structural geometry of thirty-eight Korean femurs. The purpose of this study is to identify major geometrical differences between Korean femurs 3nd others that we believe belong to Caucasians so that we would be able to get insights into the femoral component design that fits Asians including Koreans. We utilized computerized tomography (CT) images of femurs extracted from cadavers. The CT images were transformed into bitmap data by using a film scanner, and then analyzed by using a commercially available software called Image v.1.0 and a Macintosh IIci computer.The resulting data were compared with already published data. The major results show that the geometry of the Korean femurs is significantly different from that of Caucasians: (1) the anteversion angle and the canal flare index are greater by the amount of approximately 8˚ and 0.5, respectively, (2) the shape of the isthmus cross section is more round, and (3) the distance between the teaser trochanter and the proximal border of the isthmus is shelter by about 15 mm. The results suggested that the femoral component suitable for Asians should be different from the currently-used components designed and manufactured mostly by European or American companies. 30537 T00401030537 ^x It is well known that nonlinear propagation characteristics of the wave in the tissue may give very useful information for the medical diagnoisis. In this paper, a new method to detect nonlinear propagation characteristics of the internal vibration in the tissue for the low frequency mechanical vibration by using bispectral analysis is proposed. In the method, low frequency vibration of f0( = 100Hz) is applied on the surface of the object, and the waveform of the internal vibration x (t) is measured from Doppler frequency modulation of silmultaneously transmitted probing ultrasonic waves. Then, the bispectra of the signal x (t) at the frequencies (f0, f0) and (f0, 2f0) are calculated to estimate the nonlinear propagation characteristics as their magnitude ratio, w here since bispectrum is free from the gaussian additive noise we can get the value with high S/N. Basic experimental system is constructed by using 3.0 MHz probing ultrasonic waves and the several experiments are carried out for some phantoms. Results show the superiority of the proposed method to the conventional method using power spectrum and also its usefulness for the tissue characterization. 30541 T00401030541 ^x This paper describes the implementation of a computerized radial pulse diagnosis by aids of a clinical expert. On this base, we composed of the radial pulse diagnosis system in korean traditional medicine. The system composed of a radial pulse wave detection system and a radial pulse diagnosis system. With a detection system, we detected Inyoung and Cheongu radial pulse wave and processed it. Then, we have got the characteristic parameters of radial pulse wave and also quantified that according to the method of Inyoung-Cheongu Comparison Radial Pulse Diagnosis. We defined the jugement standard of radial pulse diagnosis system and then we confirmed the possibility for realization of automatic radial pulse diagnosis in korean traditional medicine. 30545 T00401030545 ^x Microspheres are expected to be applied to biomedical areas such as solid-phase immunoassays, drug delivery systems, immunomagnetic cell separation. To synthesize microspheres for biomedical application, "two stage shot growth method" was developed. The uniformity ratio of synthesized microspheres was always smaller than 1.05. And the surface charge density (or the number of ionizable functional groups) of the microspheres synthesized by "two stage shot growth method" was 6~13 times higher than that of the microspheres synthesized by conventional seeded batch copolymerization. As a previous step for biomedical application, adsorption experiments of bovine albumin on microspheres were carried out under various conditions. The maximum adsorbed amount was obtained in the neighborhood of pH 4.5. Isoelectric point of bovine albumin is pH 5.0, so experimental result shows that it shifted to acid area. The adsorption isotherm was obtained, the plateau region was always reached at 2.Og/L (bulk concentration of bovine albumin).The effect of the kind and the amount of surface functional group was also examined. 30575 T00401030575 ^x A medical image workstation was developed using multimedia technique. The system based on PC-486DX was designed to acquire medical images produced by medical imaging instruments and related audio information, that is, doctors' reporting results. Input information was processed and analyzed, then the results were presented in the form of graph and animation. All the informations of the system were hierarchically related with the image as the apex. Processing and analysis algorithms were implemented so that the diagnostic accuracy could be improved. The diagnosed information can be transferred for patient diagnosis through LAN(local area network). 30592 T00401030592 ^x In the conventional infrared imaging system, complex infrared lens systems are usually used for directing collimated narrow infrared beams into the high speed 2-dimensional optic scanner. In this paper, a simple reflective infrared optic system with a 2-dimensional optic scanner is proposed for the realization of medical infrared thermography system. It has been experimentally proven that the intfrared thermography system composed of the proposed optic system has the temperature resolution of 0.1˚c under the spatial resolution of lmrad, the image matrix size of 256 X 240, and tile imaging time of 4 seconds. 30593 T00401030593 ^x In this paper, MIIS (Medical Image Information System) has been designed and implemented using INGRES RDBMS, which is based on a client/server architecture. The implemented system allows users to register and retrieve patient information, medical images and diagnostic reports. It also provides the function to display these information on workstation windows simultaneously by using the designed menu-driven graphic user interface. The medical image compression/decompression techniques are implemented and integrated into the medical image database system for the efficient data storage and the fast access through the network. 30594 T00401030594 ^x In this paper, computerized BEAM was implemented for the space domain analysis of EEG. Trans-formation from temporal summation to two-dimensional mappings is formed by 4 nearest point inter-polaton method. Methods of representation of BEAM are two. One is dot density method which classify brain electrical potential 9 levels by dot density of gray levels and the other is colour method which classify brain electrical 12 levels by red-green colours. In this BEAM, instantaneous change and average energy distribution over any arbitrary time interval of brain electrical activity could be observed and analyzed easily. In the frequency domain, the distribution of energy spectrum of a special band can easily be distinguished normality and abnormality. 30608 T00401030608 ^x Laboratory information system (LIS) is a key tool to manage laboratory data in clinical pathology. Our department has developed an information system for routine hematology using down-sized computer system. We have used an IBM 486 compatible PC with 16MB main memory, 210 MB hard disk drive, 9 RS-232C port and 24 pin dot printer. The operating system and database management system were SCO UNIX and SCO foxbase, respectively. For program development, we used Xbase language provided by SCO foxbase. The C language was used for interface purpose. To make the system use friendly, pull-down menu was used. The system connected to our hospital information system via application program interface (API), so the information related to patient and request details is automatically transmitted to our computer. Our system interfaced with fwd complete blood count analyzers(Sysmex NE-8000 and Coulter STKS) for unidirectional data tansmission from analyzer to computer. The authors suggests that this system based on down-sized computer could provide a progressive approach to total LIS based on local area network, and the implemented system could serve as a model for other hospital's LIS for routine hematology. 30609 T00401030609 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed a composite that is consisted of calcium phosphate and collagen. To use as the structural matrix of the composite, collagen was purified from human umbilical cord. The obtained collagen was treated by pepsin to remove telopeptides, and finally, the immune-free atelocollagen was produced: The cross linked atelocollagen was highly resistant to the collagenase induced collagenolysis. The cross linked collagen demonstrated an improved tensile strength. 30618 T00401030618 ^x This paper is a study on the design of adptive filter for QRS complex detection. We propose a simple adaptive algorithm to increase capability of noise cancelation in QRS complex detection with two stage adaptive filter. At the first stage, background noise is removed and at the next stage, only spectrum of QRS complex components is passed. Two adaptive filters can afford to keep track of the changes of both noise and QRS complex. Each adaptive filter consists of prediction error filter and FIR filter The impulse response of FIR filter uses coefficients of prediction error filter. The detection rates for 105 and 108 of MIT/BIH data base were 99.3% and 97.4% respectively. 30619 T00401030619 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed and produced a composite that is consisted of calcium phosphate and collagen. Human umbilical cord origin pepsin treated type I atelocollagen was used as the structural matrix, by which sintered or non-sintered carbonate apatite was encapsulated to form an inorganic-organic composite. With cross linking atelocollagen by UV ray irradiation, the resistance to both compressive and tensile strength was increased. Collagen degradation by the collagenase induced collagenolysis was also decreased. 30620 T00401030620 ^x We have developed a monoleaflet polymer valve as an inexpensive and viable alternative, especially for short-term use in the ventricular assist device or total artificial heart. The frame and leaflet of the polymer valve were made from polyurethane, To evaluate the hemodynamic performance of the polymer valve a comparative study of flow dynamics past a polymer valve and a St. Jude Medical prosthetic valve under physiological pulsatile flow conditions in vitro was made. Comparisons between the valves were made on the transvalvular pressure drop, regurgitation volume and maximum valve opening area. The polymer valve showed smaller regurgitation volume and transvalvular pressure drop compared to the mechanical valve at higher heart rate. The results showed that the functional characteristics of the polymer valve compared favorably with those of the mechanical valve at higher heart rate. 30621 T00401030621 ^x Explosive evaporative removal process of biological tissue by absorption of a CW laser has been simulated by using gelatin and a multimode Nd:YAG laser. Because the point of maximun temperature of laser-irradiated gelatin exists below the surface due to surface cooling, evaporation at the boiling temperature is made explosively from below the surface. The important parameters of this process are the conduction loss to laser power absorption (defined as the conduction-to-laser power parameter, Nk), the convection heat transfer at the surface to conduction loss (defined as Bi), dimensionless extinction coefficient (defined as Br.), and dimensionless irradiation time (defined as Fo). Dependence of Fo on Nk and Bi has been observed by experiment, and the results have been compared with the numerical results obtained by solving a 2-dimensional conduction equation. Fo and explosion depth (from the surface to the point of maximun temperature) are increased when Nk and Bi are increased.To find out the minimum laser power for explosive evaporative removal process, steady state analysis has been also made. The limit of Nk to induce evaporative removal, which is proportional to the inverse of the laser power, has been obtained. 30622 T00401030622 ^x N1 and N2 gross neural action potentials were measured from the round window of the guinea pig cochlea at the onset of the acoustic stimuli. N1-N2 audiograms were made by means of regulating stimulant intensities in order to produce constant N1-N2 potentials as criteria for different input tone pip frequencies. The lowest threshold was measured with an input tone pip I5 dB SPL in intensity and 12 KHz in frequency when the animal was in normal physiological condition. The procedure of experimental measurements is explained in detail. This experimental approach is very useful for the investigation of the Cochlear function. Both noN1inear and active functions of the Cochlea can be monitored by N1-N2 audiograms. 30623 T00401030623 ^x In electrical impedance tomography(EIT), we use boundary current and voltage measurements toprovide the information about the cross-sectional distribution of electrical impedance or resistivity. One of the major problems in EIT has been the inaccessibility of internal voltage or current data in finding the internal impedance values. We propose a new image reconstruction method using internal current density data measured by NMR. We obtained a two-dimensional current density distribution within a phantom by processing the real and imaginary MR images from a 4.77 NMR machine. We implemented a resistivity mage reconstruction algorithm using the finite element method and sensitivity matrix. We presented computer simulation results of the mage reconstruction algorithm and furture direction of the research. 30624 T00401030624 ^x A new method of digital image analysis technique for discrimination of cancer cell was presented in this paper. The object image was the Thyroid eland cells image that was diagnosed as normal and abnormal (two types of abnormal: follicular neoplastic cell, and papillary neoplastic cell), respectively. By using the proposed region segmentation algorithm, the cells were segmented into nucleus. The 16 feature parameters were used to calculate the features of each nucleus. A9 a consequence of using dominant feature parameters method proposed in this paper, discrimination rate of 91.11% was obtained for Thyroid Gland cells. 30625 T00401030625 ^x An electrical stimulator was designed to induce locomotion for paraplegic patients caused by central nervous system injury. Optimal stimulus parameters, which can minimize muscle fatigue and can achieve effective muscle contraction were determined in slow and fast muscles in Sprague-Dawley rats. Stimulus patterns of our stimulator were designed to simulate electromyographic activity monitored during locomotion of normal subjects. Muscle types of the lower extremity were classified according to their mechanical property of contraction, which are slow muscle (msoleus m.) and fast muscle (medial gastrocneminus m., rectus femoris m., vastus lateralis m.). Optimal parameters of electrical stimulation for slow muscles were 20 Hz, 0.2 ms square pulse. For fast muscle, 40 Hz, 0.3 ms square pulse was optimal to produce repeated contraction. Higher stimulus intensity was required when synergistic muscles were stimulated simultaneously than when they were stimulated individually. Electrical stimulation for each muscle was designed to generate bipedal locomotion, so that individual muscles alternate contraction and relaxation to simulate stance and swing phases. Portable electrical stimulator with 16 channels built in microprocessor was constructed and applied to paraplegic patients due to lumbar cord injury. The electrical stimulator restored partially gait function in paraplegic patients. 30626 T00401030626 ^x Two-Dimensional modelling of the Cochlear biomechanics is presented in this paper. The Laplace partial differential equation which represents the fluid mechanics of the Cochlea has been transformed into two-dimensional electrical transmission line. The procedure of this transformation is explained in detail. The comparison between one and two dimensional models is also presented. This electrical modelling of the basilar membrane (BM) is clearly useful for the next approach to the further. Development of active elements which are essential in the producing of the sharp tuning of the BM. This paper shows that two-dimension model is qualitatively better than one-dimensional model both in amplitude and phase responses of the BM displacement. The present model is only for frequency response. However because the model is electrical, the two-dimensional transmission line model can be extended to time response without any difficult. 30627 T00401030627 ^x A method has been proposed for the fully automatic detection of left ventricular endocardial boundary in 2D short axis echocardiogram using geometric model. The procedure has the following three distinct stages. First, the initial center is estimated by the initial center estimation algorithm which is applied to decimated image. Second, the center estimation algorithm is applied to original image and then best-fit elliptic model estimation is processed. Third, best-fit boundary is detected by the cost function which is based on the best-fit elliptic model. The proposed method shows effective result without manual intervention by a human operator. 30628 T00401030628 ^x The intelligent trajectory control method that controls moving direction and average velocity for a prosthetic arm is proposed by pattern recognition and force estimations using EMG signals. Also, we propose the real time trajectory planning method which generates continuous accelleration paths using 3 stage linear filters to minimize the impact to human body induced by arm motions and to reduce the muscle fatigue. We use combination of MLP and fuzzy filter for pattern recognition to estimate the direction of a muscle and Hogan's method for the force estimation. EMG signals are acquired by using a amputation simulator and 2 dimensional joystick motion. The simulation results of proposed prosthetic arm control system using the EMf signals show that the arm is effectively followed the desired trajectory depended on estimated force and direction of muscle movements. 30638 T00401030638 ^x A new neural network architecture for the recognition of patterns from images is proposed, which is partially based on the results of physiological studies. The proposed network is composed of multi-layers and the nerve cells in each layer are connected by spatial filters which approximate receptive fields in optic nerve fields. In the proposed method, patterns recognition for complicated images is carried out using global features as well as local features such as lines and end-points. A new generating method of matched filers representing global features is proposed in this network. 30659 T00401030659 ^x An implementation scheme of the magnetic nerve stimulator using a switching mode power supply is proposed. By using a switching mode power supply rather than a conventional linear power supply for charging high voltage capacitors, the weight and size of the magnetic nerve stimulator can be considerably reduced. Maximum output voltage of the developed magnetic nerve stimulator using the switching mode power supply is 3,000 volts and switching time is about 100 msec. Experimental results or human nerve stimulations using the developed stimulator are presented. 30768 T00401030768 ^x In this paper, we describe the design methodology and specifications of the developed module-based bedside monitors for patient monitoring. The bedside monitor consists of a main unit and module cases with various parameter modules. The main unit includes a 12.1" TFT color LCD, a main CPU board, and peripherals such as a module controller, Ethernet LAN card, video card, rotate/push button controller, etc. The main unit can connect at maximum three module cases each of which can accommodate up to 7 parameter modules. They include the modules for electrocardiograph, respiration, invasive blood pressure, noninvasive blood pressure, temperature, and SpO2 with Plethysmograph.

  • PDF