• Title/Summary/Keyword: radio frequency spectrum

Search Result 369, Processing Time 0.029 seconds

Performance Analysis of M-ary PPM UWB Suitable to FCC Signal Spectrum (FCC 신호 스펙트럼에 적합한 M-ary PPM UWB 시스템의 성능분석)

  • ;;Brant Parr
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.28 no.8A
    • /
    • pp.633-643
    • /
    • 2003
  • UWB impulse radio signals have an very short duration, extremely wide bandwidth and share the same frequency spectrum with other existing systems. It was determined by the Federal Communications Commission (FCC) that UWB systems could cause interference with other systems, such as Global Positioning System (GPS) for example. Therefore, at present. the FCC has restricted the use of UWB systems to frequencies above 3.1㎓. In this paper, We evaluated performance of UWB system using proposed pulses in [1][2] that are strictly limited in time to remove interference while, at the same time, contain their power distribution to a frequency band from 3.1㎓ to 10.6㎓. In particular, We evaluated the BER Performance in relation to system parameters such as pulse duration. $\delta$, the number of users. Nu. and the number of symbols, M. We found the optimal pulse duration $\delta$ through computer simulation using developed UWB pulses in [1][2]. It is shown that performance evaluation between the UWB communication system using these UWB pulses [1][2]and the Gaussian monocycle pulse in M-ary PPM and BPSK schemes. These results can be contributed to construct M-ary PPM UWB communication system in terms of multiuser parameters and pulse duration.

Novel Turbo Receiver for MU-MIMO SC-FDMA System

  • Wang, Hung-Sheng;Ueng, Fang-Biau;Chang, Yu-Kuan
    • ETRI Journal
    • /
    • v.40 no.3
    • /
    • pp.309-317
    • /
    • 2018
  • Single carrier-frequency-division multiple access (SC-FDMA) has been adopted as the uplink transmission standard in fourth-generation cellular networks to facilitate power efficiency transmission in mobile stations. Because multiuser multiple-input multiple-output (MU-MIMO) is a promising technology employed to fully exploit the channel capacity in mobile radio networks, this study investigates the uplink transmission of MU-MIMO SC-FDMA systems with orthogonal space-frequency block codes (SFBCs). It is preferable to minimize the length of the cyclic prefix (CP). In this study, the chained turbo equalization technique with chained turbo estimation is employed in the designed receiver. Chained turbo estimation employs a short training sequence to improve the spectrum efficiency without compromising the estimation accuracy. In this paper, we propose a novel and spectrally efficient iterative joint-channel estimation, multiuser detection, and turbo equalization for an MU-MIMO SC-FDMA system without CP-insertion and with short TR. Some simulation examples are presented for the uplink scenario to demonstrate the effectiveness of the proposed scheme.

Characterization and Emission/Absorption Study of a Grimm-type Glow discharge source in the application of high frequency Glow Discharge (고주파 글로우 방전을 이용한 GRIMM형 방전원의 특성 및 방출/흡광분석법 연구)

  • Suh, Jung-Gee;Woo, Jin-Chun
    • Analytical Science and Technology
    • /
    • v.7 no.2
    • /
    • pp.155-164
    • /
    • 1994
  • A conventional Grimm-type glow discharge source was constructed and applied to radio-frequency(13.56MHz) discharge for metal and ceramic analysis. We investigated the emission spectrum for aluminium and aluminium oxide and the influence of discharge operating paramaters including argon pressure, rf-power and DC-bias voltages at the sample-side electrode. Scanning Electron Microscope(SEM) also was used to investigate the effect of rf-sputtering on the microstructure formation of the aluminium oxide. Linear analytical calibration curves were constructed for Manganese and zinc element in samples of low alloy steel(BAS 401-405) and brass(NIST 1108-1117).

  • PDF

Vector Passive Harmonic Mode-locking Fiber Laser Based on Topological Insulator Bi2Se3 Interacting with Fiber Taper

  • Li, Jian Ping
    • Journal of the Optical Society of Korea
    • /
    • v.20 no.1
    • /
    • pp.135-139
    • /
    • 2016
  • I propose a vector passive harmonic mode-locked fiber laser based on topological insulator Bi2Se3 interacting with a fiber taper with a diameter of 7 μm. The particles of topological insulator are deposited uniformly onto the fiber taper with light pressure effect. By incorporating the fabricated saturable absorber into an Er-doped fiber laser cavity, stable mode-locked fiber is obtained. Due to the intense evanescent field of the fiber taper, strong confinement of light enhances the nonlinearity of the laser cavity, and passive harmonic mode-locking is performed. I observe a maximum harmonic mode-locking of 356th, corresponding to a frequency of 3.57 GHz. The pulse duration is 824 fs, and the full width at half maximum of the spectrum is about 8.2 nm. The polarization dependent loss of the saturable absorber is ~ 2.5 dB in the wavelength range of the C band. As the cavity contains no other polarization dependent device, the mode-locked laser is functioning in the vector state. The harmonic order vs pump power is investigated. To the best of our knowledge, this report is the highest frequency mode-locked fiber laser based on Bi2Se3. Experimental results indicate that the topological insulator Bi2Se3 functioning with a thin fiber taper is effective for vector harmonic mode-locking.

Performance of MC-CDMA Based UWB System (MC-CDMA 방식을 적용한 UWB 시스템의 성능평가)

  • Kim Cheol-Soon;Kwak Kyung-Sup;Lee Hyung-Ki
    • Journal of Korea Multimedia Society
    • /
    • v.9 no.1
    • /
    • pp.51-58
    • /
    • 2006
  • In this paper, we evaluated Ultra Wideband MC-CDMA system which is the combination of DS-CDMA and OFDM systems, which have been drafting in current standardization for IEEE802.15.3a. Too many Rake Fingers are demanded in the DS-CDMA system to detect multi-path signals, which results in high system complexity. OFDM system fails to qualify for FCC certification unless frequency hopping is off. MC-CDMA has lower complexity compared to DS-CDMA and shows good performance against frequency selective fading. In addition, for a wide-band communication, less radio power per spectrum is allowed in the MC-CDMA system than in an OFDM system. The MC-CDMA system is analyzed by a numerical formula and compared with DS-CDMA and OFDM by a computer simulation.

  • PDF

Development and characterization of a ultra-wide bandwidth video detector for the UHF partial discharge monitoring system (UHF 부분방전 감시 장치를 위한 초광대역 검출장치 개발 및 특성조사)

  • Park, Ki-Jun;Goo, Sun-Geun;Yoon, Jin-Yul
    • Proceedings of the KIEE Conference
    • /
    • 2002.07c
    • /
    • pp.1649-1651
    • /
    • 2002
  • Ultra-wide bandwidth (UWB) detection method has been widely used as a front end detection scheme for the ultra-high frequency (UHF) partial discharge (PD) monitoring systems. A broad-band video detector module was developed and characterized for the UHF UWB PD detection systems. The useable bandwidth of the module is more than 2 GHz and it is optimized for 50-ohm systems. The detection sensitivity and dynamic range of the module were characterized by using a known ns-width RF pulses of GHz range. The dynamic range is more than 6-decades and the module can detect pulsed RF signals down to 1 nW. The detector module can eliminate expensive equipment such as high speed oscilloscopes and radio frequency (RF) spectrum analyzers. Therefore, it enables one to use slow speed data acquisition systems for the PD monitoring at the UHF range. The detector module was used to detect real PDs of about <3 pC. The module converts the UWB PD signals into a low-bandwidth video signal with a high signal-to-noise ratio.

  • PDF

A Study on the Thickness Measurement of Blood Vessel Wall using the Wavelet Transform of Ultrasound RF Signal (초음파 RF 신호의 Wavelet 변환을 이용한 혈관 벽의 두께 측정에 관한 연구)

  • 김재익;최흥호
    • Journal of Biomedical Engineering Research
    • /
    • v.22 no.2
    • /
    • pp.179-185
    • /
    • 2001
  • 혈관에 발생하는 동맥 경화증은 그 발생 시기와 진행 정도를 예측하기 힘들어 초기 단계의 진단 및 치료가 어렵다. 이러한 이유로 혈관 질병의 진단은 많은 연구자들의 관심 대상이 되어왔고, 현재까지도 그 진단 장치 및 방법에 관한 연구가 활발히 진행되고 있다. 혈관 벽의 두께 측정은 혈관 질병을 진단할 수 있는 대표적인 지표이다. 그러므로 본 연구는 혈관 벽에서 수신되는 초음파 RF(Radio Frequency) 신호를 wavelet 변환하여 두께를 측정할 수 있는 방법을 제안한다. 시뮬레이션 결과를 토대로 두께가 각각 0.53mm, 1.2mm인 고분자 물질을 가지고 두께측정 실험을 행하였다. 기존의 방법인 주파수 스펙트럼법과 제안한 방법인 wavelet 변환법에 의하여 측정된 평균 두께는 0.53mm인 경우 각각 0.670$\pm$0.168mm(79.10%), 0.448$\pm$0.084mm(84.53%)이고, 1.2mm인 경우 각각 0.962$\pm$0.072mm(80.17%), 1.149$\pm$0.066mm(95.15%)이다. In-vitro 실험을 행하기 위하여 한천, gelatin, SiC 결정을 가지고 두께가 0.85mm인 혈관 유사 시편을 제작하였고, 이 시편으로부터 데이터를 획득하여 이를 제안한 방법으로 두께를 측정하였다. 그 결과 제안한 방법으로 측정된 평균 두께는 0.8008$\pm$0.0154mm(94.22%)이다. 결론적으로 wavelet 변환을 통해서 혈관 벽의 두께를 정밀하게 측정할 수 있는 가능성이 있음을 알 수 있다.

  • PDF

Development of Personal Hand-held Electronic Devices for Marine Leisure Safety (해양레저 안전을 위한 개인 휴대용 전자장치 개발)

  • Yim Jeong-Bin;Nam Taek-Keun
    • Journal of Navigation and Port Research
    • /
    • v.30 no.5 s.111
    • /
    • pp.357-362
    • /
    • 2006
  • This paper describes two kinds of personal hand-held electronic devices to enhance marine leisure safety. The one is Radar response-type safety device triggering by the pulse signal from a commercial 9GHz-band Radar to provide quick search and rescue with combined civilian-government-military fleets. The other one is M-RFID (Marine Radio Frequency IDentification) based safety electronic device using 900MHz Tx/Rx with spread spectrum frequency hopping and GPS. Through the field tests at sea using Korea Coast Guard's warship the operating performances are verified. Further plan for practical use of each device was also discussed.

A variation of elastic modulus of very thin diamond-like carbon films with deposition condition (증착조건에 따른 극미세 다이아몬드상 카본 박막의 탄성률 변화거동)

  • 정진원;이광렬;은광용;고대홍
    • Journal of the Korean Vacuum Society
    • /
    • v.10 no.4
    • /
    • pp.387-395
    • /
    • 2001
  • The elastic modulus and the structural evolution were examined with the film thickness in polymeric, hard, graphitic diamond-like carbon (DLC) films. The DLC films used in the present study were prepared by radio frequency plasma assisted chemical vapor deposition (r.f.-PACVD) from $C_6H_6\;and\;CH_4$ gas. Elastic modulus of very thin DLC film was measured by free overhang method. This method has an advantage over the other methods. Because the substrate was removed by etching technique, the measured value is not affected by the mechanical property of the substrate. The structural evolution was investigated by the G-peak position of the Raman spectrum. The polymeric and graphitic films exhibited the decreased elastic modulus with decreasing film thickness. In polymeric films, the reason was that more polymeric film had been deposited in the initial stage of the film growth and in graphitic film more graphic films which had been deposited in the initial stage decreased the elastic modulus. The G-peak position of the Raman spectrum confirmed this result. On the other hand, the hard film showed the constant elastic modulus regardless to the film thickness. The structural change was not observed in this range of the film thickness.

  • PDF

A Novel Detection Method of the Satellite Phone Signal based on Array Antennas (Array 안테나를 이용한 위성전화신호의 검출 방법)

  • Kim, Yun-Bong;Song, Jeong-Ig;Ning, Han;Kim, Jae-Moung
    • Journal of Satellite, Information and Communications
    • /
    • v.2 no.2
    • /
    • pp.53-58
    • /
    • 2007
  • The Satellite Mobile Communication System holds several advantages, such as wide coverage that guarantees the communication in a huge area. It is suitable in the ocean and forest and especially in emergency situation. However, the licensed frequency is not always occupied within all coverage and all the time. The actual utilization rate is relatively low compared to other wireless communications such as cellular systems. There are a large amount of white spaces in its coverage. Therefore, it is necessary to consider introducing additional services such as data communication, in order to increase the spectrum utilization as well as the revenue of the Satellite service provider. In this paper, we first analyze the possibility to implement new services in the licensed band of satellite mobile phone by its provider. Then we address the most significant issue for the implementation of current service, which is how to accurately detect the satellite mobile terminals. Finally, we suggest two new possible solutions namely, eigenvalue detection based methods to find out the existence of transmitted signal from the satellite mobile terminals.

  • PDF