• Title/Summary/Keyword: radiation safety report

Search Result 63, Processing Time 0.021 seconds

Status of Medical Exposure in Korea

  • Yoon, Sei-Chul;Kim, Il-Han;Kim, Sung-Hoon;Kim, Hyuck-Joo
    • Journal of Radiation Protection and Research
    • /
    • v.35 no.3
    • /
    • pp.96-98
    • /
    • 2010
  • Medical use of radiation is increasing in recent times and its influence on the population creates almost the same amount of annual natural background radiation in industrialized countries in particular. Thus, medical radiation has become a social issue. This paper is a brief report on the status of medical exposure in Korea by way of consulting from the radiation-related medical societies in Korea.

Statistical Analysis Using Living Radiation Survey Data on Processed Products (가공제품에 대한 생활주변방사선 실태조사 자료를 활용한 통계분석)

  • Choi, Kyoungho;Cho, Jung Keun
    • Journal of radiological science and technology
    • /
    • v.43 no.2
    • /
    • pp.123-128
    • /
    • 2020
  • Radiation Following the 2011 Fukushima nuclear accident in Japan, public interest and anxiety about radiation safety increased, and vague anxiety about commonly exposed living radiation was generated. The Atomic Energy Safety Commission has been conducting a survey of processed products that advertise "negative ions" and "far-infrared" emissions under the Living Radiation Safety Management Act. In this study, in-depth analysis was performed from a statistical point of view using the measurement data presented in the Nuclear Safety Committee's actual survey analysis report as secondary data. As a result, there was a statistically significant difference (p<0.005) between latex and civil affairs products. There were also statistically significant differences (p<0.05) in the results of testing whether there were significant differences in the annual exposure dose between groups after categorizing 71 civil products, including radon beds, into bed, bedding, and living and other categories. The correlation analysis results also confirm that, as is commonly known, the annual doses received from processed products are associated with radon derived from U-238 and Th-232.

Analysis of radiation safety management status of medical linear accelerator facilities in Korea

  • Kwon, Na Hye;Shin, Dong Oh;Ann, So Hyun;Kim, Jin Sung;Choi, Sang Hyoun;Kim, Dong Wook
    • Nuclear Engineering and Technology
    • /
    • v.54 no.2
    • /
    • pp.449-455
    • /
    • 2022
  • The rapid rise in the application of novel treatment techniques, such as intensity-modulated radiotherapy (IMRT), motivated us to survey the status of Korea's radiation safety management and the shielding designs of facilities employing medical linear accelerators (LINACs). To this end, a questionnaire was used to collect information on LINAC facilities and treatments, workload, shielding design, shielding management, and path of obtaining shielding information. Out of 100 domestic institutions, 52 responded to the survey. Approximately 70% of the institutions utilized IMRT for more than 60% of their cases, and an IMRT factor of 5 was adopted by 75% of these institutions. Over 80% of the institutions accounted for the applied time-averaged dose rate per week and instantaneous dose equivalent rates in their shielding designs. Approximately 45% of the institutions obtained important shielding information via a radiation shielding design company and the NCRP-151 report. Overall, most facilities were shown to follow the standards recommended by the relevant international agencies. However, the requirement to establish standardized shielding design information and clarify ambiguous paths for information acquisition was also highlighted. Therefore, the study's results can be used as a foundation for establishing a safety control system and for creating adequate shielding designs.

The System of Radiation Dose Assessment and Dose Conversion Coefficients in the ICRP and FGR

  • Kim, Sora;Min, Byung-Il;Park, Kihyun;Yang, Byung-Mo;Suh, Kyung-Suk
    • Journal of Radiation Protection and Research
    • /
    • v.41 no.4
    • /
    • pp.424-435
    • /
    • 2016
  • Background: The International Commission on Radiological Protection (ICRP) recommendations and the Federal Guidance Report (FGR) published by the U.S. Environmental Protection Agency (EPA) have been widely applied worldwide in the fields of radiation protection and dose assessment. The dose conversion coefficients of the ICRP and FGR are widely used for assessing exposure doses. However, before the coefficients are used, the user must thoroughly understand the derivation process of the coefficients to ensure that they are used appropriately in the evaluation. Materials and Methods: The ICRP provides recommendations to regulatory and advisory agencies, mainly in the form of guidance on the fundamental principles on which appropriate radiological protection can be based. The FGR provides federal and state agencies with technical information to assist their implementation of radiation protection programs for the U.S. population. The system of radiation dose assessment and dose conversion coefficients in the ICRP and FGR is reviewed in this study. Results and Discussion: A thorough understanding of their background is essential for the proper use of dose conversion coefficients. The FGR dose assessment system was strongly influenced by the ICRP and the U.S. National Council on Radiation Protection and Measurements (NCRP), and is hence consistent with those recommendations. Moreover, the ICRP and FGR both used the scientific data reported by Biological Effects of Ionizing Radiation (BEIR) and United Nations Scientific Committee on the Effects of Atomic Radiation (UNSCEAR) as their primary source of information. The difference between the ICRP and FGR lies in the fact that the ICRP utilized information regarding a population of diverse races, whereas the FGR utilized data on the American population, as its goal was to provide guidelines for radiological protection in the US. Conclusion: The contents of this study are expected to be utilized as basic research material in the areas of radiation protection and dose assessment.

Study on Radiation Dose in the Medical Image Data Display Method - Focused on the DICOM Standard (의료영상 데이터에서의 피폭선량 표시 방법에 관한 고찰: DICOM 표준을 중심으로)

  • Kim, Jung-Su
    • Journal of radiological science and technology
    • /
    • v.38 no.4
    • /
    • pp.483-489
    • /
    • 2015
  • DICOM (Digital Imaging and Communications in Medicine) standards are generally introduced as de facto and de jure standards in modern medical imaging devices to store and to transmit medical image information. DICOM Dose Structured Report (DICOM dose SR) is implemented to report radiation exposure information in image acquiring process. and DIOCM Modality Performed Procedure Step (DICOM MPPS) is also partly used to report this exposure with the information in its DICOM tag. This article is focused on three type of radiation exposure information of DICOM standards, 1) DICOM dose SR, 2) DICOM MPPS and 3) Radiation Exposure Monitoring(REM) profile by Integrating the Healthcare Enterprise(IHE), to study on radiation exposure reporting. Healthcare facility and its staff of medical imaging related to radiation exposure should have a deep understanding of radiation exposure, and it required a standards to enhance the quality control of medical imaging and the safety of patients and staffs. Staff member have to pay attention on radiation exposures and controling processes from the purchasing stage of X-ray devices.

Preliminary study for the development of radiation safety evaluation methodology for industrial kV-rated radiation generator facilities

  • Hye Sung Park ;Na Hye Kwon ;Sang Rok Kim ;Hwidong Yoo;Jin Sung Kim ;Sang Hyoun Choi;Dong Wook Kim
    • Nuclear Engineering and Technology
    • /
    • v.55 no.10
    • /
    • pp.3854-3859
    • /
    • 2023
  • Background: This study aims to develop an evaluator that can quickly and accurately evaluate the shielding of low-energy industrial radiation generators. Methods: We used PyQt to develop a graphical user interface (GUI)-based program and employed the calculation methodology reported in the National Council on Radiation Protection and Measurements (NCRP)-49 for shielding calculations. We gathered the necessary factors for shielding evaluation using two libraries designed for Python, pandas and NumPy, and processed them into a database. We verified the effectiveness of the proposed program by comparing the results with those from safety reports of six domestic facilities. Results: After verifying the effectiveness of the program using the NCRP-49 example, we obtained an average error rate of 1.73%. When comparing the facility safety report and results obtained using the program, we found that the error rate was between 1.09% and 6.51%. However, facilities that did not use a defined shielding methodology were underestimated by 31.82% compared with the program (the final barrier thickness satisfied the shielding standard). Conclusion: The developed program provides a fast and accurate shielding evaluation that can assist personnel that work in radiation generator facilities and government officials in reviewing safety.

Basic Principles of CT Dose Index and Understanding of CT Parameter for Dose Reduction Technique (CT선량지표의 원리와 선량감소 방안에 관한 연구)

  • Kim, Jung-Su;Kwon, Soon-Mu;Kim, Jung-Min
    • Journal of radiological science and technology
    • /
    • v.38 no.1
    • /
    • pp.51-61
    • /
    • 2015
  • Computed tomography(CT) using radiation have potential risks. All medical radiographic examinations should require the justification of medical imaging examinations and optimization of the image quality and radiation exposure. The CT examination was higher radiation dose then general radiography. Especially pediatric CT examinations need to great caution of radiation risk. Because of pediatric patient was more sensitive of radiation exposure. Therefore, physician should consider the knowledge of CT radiation exposure indicator information for reduce a needless radiation exposure. This article was aim to understanding of CT exposure indicator, size-specific dose estimates by American Association of Physicists in Medicine (AAPM) report 204, XR 25 and understanding of CT dose reduction technique.

Reliability and Validity of a Nationwide Survey (the Korean Radiation Workers Study)

  • Lee, Dalnim;Lim, Wan Young;Park, Soojin;Jin, Young Woo;Lee, Won Jin;Park, Sunhoo;Seo, Songwon
    • Safety and Health at Work
    • /
    • v.12 no.4
    • /
    • pp.445-451
    • /
    • 2021
  • Background: This study aimed to evaluate the reliability and validity of the self-administered questionnaire for Korean radiation workers. Methods: From May 24, 2016, to June 30, 2017, 20,608 participants completed the questionnaire, providing information on sociodemographics, lifestyle, work history and practices, medical radiation exposure, and medical history, which was linked to the National Dose Registry and the National Cancer Registry. The validity of the questionnaire was evaluated using the responses of 20,608 workers, and reliability was evaluated using the responses of 3043 workers who responded to the survey twice. Results: Responses concerning demographic characteristics and lifestyle showed reliability with a moderate-to-high agreement (kappa: 0.43-0.99), whereas responses concerning occupation and medical radiation exposure had a wide range of agreement (kappa: 0.05-0.95), possibly owing to temporal variability during employment. Regarding validity, responses to the question about the first year of employment had an excellent agreement with the national registry (intraclass correlation coefficient = 0.9); however, responses on cancer history had a wide range of agreement (kappa: 0.22-0.85). Conclusion: Although the reliability and validity of the questionnaire were not distinguished by demographic characteristics, they tended to be low among participants whose occupational radiation exposure was minimal. Overall, the information collected can be reliable for epidemiological studies; however, caution must be exercised when using information such as medical exposure and work practices, which are prone to temporal variability.

Safety of radiotherapy in patients with Behcet's disease: a case report and review of the literature

  • Ko, Dahui;Kim, Young Suk;Choi, Yunseon
    • Journal of Medicine and Life Science
    • /
    • v.18 no.2
    • /
    • pp.35-39
    • /
    • 2021
  • Exaggerated acute and late toxicities following radiotherapy have been reported in patients with pre-existing connective tissue diseases, such as systemic lupus and scleroderma. Behcet's disease (BD) is a relapsing multisystem connective tissue disease characterized by vasculitis in the mucocutaneous, ocular, gastrointestinal, respiratory, neurologic, urogenital, articular, and cardiovascular systems. Data concerning the relationship between radiotherapy toxicity and BD are limited in the literature. Here, we report a case of lung cancer treated with radiotherapy (60 Gy) in a patient with BD. No severe radiation-induced toxicity was observed. Radiation-induced toxicity in patients with BD has also been discussed.

A Study on Estimation of Radiation Exposure Dose During Dismantling of RCS Piping in Decommissioning Nuclear Power Plant

  • Lee, Taewoong;Jo, Seongmin;Park, Sunkyu;Kim, Nakjeom;Kim, Kichul;Park, Seongjun;Yoon, Changyeon
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.19 no.2
    • /
    • pp.243-253
    • /
    • 2021
  • In the dismantling process of a reactor coolant system (RCS) piping, a radiation protection plan should be established to minimize the radiation exposure doses of dismantling workers. Hence, it is necessary to estimate the individual effective dose in the RCS piping dismantling process when decommissioning a nuclear power plant. In this study, the radiation exposure doses of the dismantling workers at different positions was estimated using the MicroShield dose assessment program based on the NUREG/CR-1595 report. The individual effective dose, which is the sum of the effective dose to each tissue considering the working time, was used to estimate the radiation exposure dose. The estimations of the simulation results for all RCS piping dismantling tasks satisfied the dose limits prescribed by the ICRP-60 report. In dismantling the RCS piping of the Kori-1 or Wolsong-1 units in South Korea, the estimation and reduction method for the radiation exposure dose, and the simulated results of this study can be used to implement the radiation safety for optimal dismantling by providing information on the radiation exposure doses of the dismantling workers.