• Title/Summary/Keyword: radiation response

Search Result 1,314, Processing Time 0.031 seconds

The Effects of Metal Plate loaded on TLD chip in 6 MV Photon and 6 MeV Electron Beams (6 MV 광자선과 6 MeV 전자선 하에서 TLD 기판 위에 얹힌 금속 박막의 효과)

  • Kim, Sookil;Byungnim Min
    • Progress in Medical Physics
    • /
    • v.10 no.1
    • /
    • pp.41-46
    • /
    • 1999
  • There is necessity for making a smaller and more sensitive detector in small field sizes. This report assesses the suitability of metal-loaded thermoluminescent dosimeters for this purpose. Measurements were performed in the 6 MV photon and 6 MeV electron beams of a medical linear accelerator with LiF thermoluminescence dosimeters (TLD-100) embedded in solid water phantom. TLD-100 chips(surface area 3.2 $\times$ 3.2 $\textrm{mm}^2$) loaded with a metal plate(Tin or gold respectively) were used to enhance dose readings to TLD-100. Surface dose was measured for field size 10 $\times$ 10 $\textrm{cm}^2$ and 100 em SSD. Measurements have been made of the enhanced signal intensity and good linearity for absorbed dose with each metal. Using a 1 mm each metal on TLD-l00 in the beam increased the surface dose to 14% and 56% respectively for 6MV photon. In the case of 6 MeV electron, gold plate enhanced the TL response to 13%, but there is no difference for tin plate. The specific dose response of TLD-100 with thin metal plate increases with electron concentration of metal film, this is most likely due to increased electron scattered from the additional material with electron density higher than TLD-100. This emphasizes the role of TL dosimeters with metal as amplified dosimeters for therapeutic high energy x-ray beams. Due to the enhanced dose reading of TLD-100 with metal plate, it could be possible to develop smaller TL dosimeter with high sensitivity.

  • PDF

Usefulness of Vibration Response Imaging (VRI) for Pneumonia Patients (폐렴환자에서 진동 공명 영상 검사(VRI)의 유용성)

  • Park, Eu-Gene;Park, Jung-Hee;Hong, Mi-Jin;Kim, Won-Dong;Lee, Kye-Young;Kim, Sun-Jong;Kim, Hee-Joung;Ha, Kyoung-Won;Chon, Gyu-Rak;Kim, Hyun-Ai;Yoo, Kwang-Ha
    • Tuberculosis and Respiratory Diseases
    • /
    • v.71 no.1
    • /
    • pp.30-36
    • /
    • 2011
  • Background: Pneumonia is commonly seen in outpatient clinics. it is widely known as the most common cause of death from infectious disease. Pneumonia has been diagnosed by its typical symptoms, chest X-ray and blood tests. However, both chest X-rays and blood tests have limitations in diagnosis. Thus primary care clinicians usually have been constrained due to a lack of adequate diagnostic tools. Vibration response imaging (VRI) is a newly emerging diagnostic modality, and its procedure is non-invasive, radiation-free, and easy to handle. This study was designed to evaluate the diagnostic usefulness of the VRI test among pneumonia patients and to consider its correlation with other conventional tests such as Chest X-ray, laboratory tests and clinical symptoms. Methods: VRI was performed in 46 patients diagnosed with pneumonia in Konkuk University Medical Center. VRI was assessed in a private and quiet room twice: before and after the treatment. Sensors for VRI were placed on a patient's back at regular intervals; they detected pulmonary vibration energy produced when respiration occurred and presented as specific images. Any modifications either in chest X-ray, C-reactive protein (CRP), white blood cell count (WBC) or body temperature were compared with changes in VRI image during a given time course. Results: VRI, chest X-ray and CRP scores were significantly improved after treatment. Correlation between VRI and other tests was not clearly indicated among all patients. But relatively severe pneumonia patients showed correlations between VRI and chest X-ray, as well as between VRI and CRP. Conclusion: This study demonstrates that VRI can be safely applied to patients with pneumonia.

Effects of EAS Systems on Pacemakers and ICDs Malfunction (도난방지 시스템의 전자기장이 인공심장 박동기 등의 오동작에 미치는 영향)

  • Shim, Young-Woo;Kim, Jong-Jeong;Yang, Dong-In;Lee, Moon-Hyung;Kim, Deok-Won
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.46 no.6
    • /
    • pp.44-49
    • /
    • 2009
  • EAS (electronic article surveillance) systems have increased rapidly for article surveillance. In this paper, the strength of the EMF (electromagnetic fields) of EAS systems were measured. Pacemaker and ICD were investigated for inappropriate response resulting from EM (electromagnetic) EAS systems. The strength of EMF and the response of pacemaker and ICD were measured in the inner left side, outer right sides and the center of gates of the 6.3 kHz and 14.25 kHz EAS systems at a height of 130cm. As the result, EMF of the EAS system using 14.25 kHz was stronger than that of 6.3 kHz. AU interferences were observed only for 14.25 kHz, and the noisy ECG was found in three static positions on the pacemaker. The ICD resulted in noise reversion and VF (ventricular fibrillation) both static and moving positions by the EMP of 14.25 kHz EAS system. Therefore, it is necessary to post a message warning radiation of EMF from every EAS systems and possible risk of pacemakers and ICDs.

Loganin Inhibits α-MSH and IBMX-induced Melanogenesis by Suppressing the Expression of Tyrosinase in B16F10 Melanoma Cells (마우스 흑색종 B16F10세포에서 loganin의 티로시나아제 발현 억제를 통한 멜라닌 생성 억제에 대한 기전연구)

  • Jung, Hee Jin;Bang, EunJin;Kim, Byeong Moo;Jeong, Seong Ho;Lee, Gil Han;Chung, Hae Young
    • Journal of Life Science
    • /
    • v.29 no.11
    • /
    • pp.1200-1207
    • /
    • 2019
  • Ultraviolet radiation exposure is a major cause of extrinsic skin aging, which leads to skin hyperpigmentation. Loganin, a major iridoid glycoside obtained from Corni fructus, has anti-inflammatory, anti-diabetic, and neuroprotective effects. In this study, we investigated the mechanisms underlying the anti-melanogenic effects of loganin in B16F10 melanocytes treated with ${\alpha}$-melanocyte stimulating hormone (${\alpha}-MSH$) and 3-isobutyl-1-methylxanthine (IBMX). Anti-melanogenic activity was measured by treating cells with loganin at concentrations between 1 and $20{\mu}m$. Cell viability assays confirmed that doses of loganin up to $20{\mu}m$ were not cytotoxic. Loganin significantly and dose-dependently decreased intracellular melanin production. We also investigated potential molecular signaling pathways for the anti-melanogenesis effects of loganin. Western blotting showed that treatment with ${\alpha}-MSH$ and IBMX increased the phosphorylation of cAMP response element-binding protein (CREB) and the gene expressions of microphthalmia-associated transcription factor (MITF) and tyrosinase. Addition of loganin suppressed these increases, while promoting the phosphorylation of extracellular signal regulated kinase (ERK) and the anti-melanogenesis response. Our data therefore indicated that loganin could attenuate the increased melanin synthesis induced by ${\alpha}-MSH$ and IBMX treatment of B16F10 melanocytes. This attenuation appears to occur by downregulation of CREB phosphorylation and MITF and tyrosinase gene expression and upregulation of ERK phosphorylation. These finding suggests that loganin could be a valuable candidate for treatment of skin diseases related to hyperpigmentation.

Analysis of the Necessity of Medical Records Related to Radiological Examination (방사선검사의 의무기록에 관한 요구도 분석)

  • Hong, Dong-Hee;Lim, Cheong-Hwan;Lim, Woo-Taek;Joo, Young-Cheol;Jung, Hong-Ryang;Kim, Eun-Hye;Yoon, Yong-Su;Jung, Young-Jin;Choi, Ji-Won;Jeong, Sung-Hun;Park, Myeong-Hwan;Yang, Oh-Nam;Jeong, Bong-Jae
    • Journal of radiological science and technology
    • /
    • v.44 no.5
    • /
    • pp.513-523
    • /
    • 2021
  • The purpose of this study was to discuss the required items and feasibility of medical records of radiological examinations performed by radiological technologists at medical institutions. An online survey was conducted to a total of 10,000 radiation-related workers, of which 1,026 (10.3%) responded. As a research method, self-made questionnaires were used. The online survey was conducted from September 10 to September 20, 2021 for the survey period. For response data, a Chi-square test was performed according to demographic characteristics using SPSS 27.0 version (IBM Inc., Chicago, Ill, USA), and it was judged to be significant when the P value was less than 0.05. The reliability of the questionnaire response was found to be Chronbach α=0.933. More than 90% of the medical records related to radiological examinations are necessary, and they answered that a curriculum, remuneration curriculum, and legal system for medical records should be prepared. More than 90% of the respondents agreed with the proposal of the Radiological Technologist Independent Act for legal preparation, and most of the information required for medical records is currently recorded in DICOM images. According to the demographic characteristics, the medical record requirement for radiological examination, curriculum, continuing education, and legislation were found to be higher with higher education and higher with longer working experience. In addition, most of the radiology departments showed a high demand for medical records, so most of them responded positively to the medical records requirements for radiological examinations. This study analyzed the medical record requirements for radiological examinations, and as shown in the results, medical record requirements for radiological examinations was found that most radiological technologists felt need for the new law and supported it. In addition, if the information recorded in the DICOM image is used, it is considered that medical records could be easily prepared without additional work by the radiological technologists.

Development of Performance Analysis 80 kW High-efficiency Permanent Magnet Generator for Radar System Power Supply (레이더 체계 전원공급용 80 kW급 고효율 영구자석형 발전기 개발 및 성능분석)

  • Ryu, Ji-Ho;Cho, Chong-Hyeon;Chong, Min-Kil;Park, Sung-Jin;Kang, Kwang-Hee
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.22 no.1
    • /
    • pp.60-71
    • /
    • 2019
  • Electrical power supply is needed to operate the radar system in the field. In addition, it should not cause performance deterioration under the environmental factors due to characteristics of military equipment, and should not cause malfunction due to electromagnetic waves generated in radar, and then should not cause malfunction in radar equipment. Therefore, By applying a permanent magnet to the rotor of the generator, light weighting and high efficiency of generator were achieved. As a result, electrical performance test of the generator, the rated output power was 80.8 kW, the maximum output power was 88.1 kW, and the output power efficiency was 98.1 % under the full load condition. When the load capacity of the generator was changed from no load to full load, the maximum voltage variation was 3.6 % and the frequency variation was 0.3 %. As a result of the transient response test for measuring the output power of the generator according to the load characteristics change, the maximum voltage variation of 7.9 %, frequency variation of 0.5 % were confirmed, and the transient response time was 2.1 seconds. Environmental tests were conducted in accordance with MIL-STD-810G and MIL-STD-461F to evaluate the operability of the generator groups. Normal operation of radar system generator group was confirmed under high temperature and low temperature environment conditions. Electromagnetic tests were conducted to check if electromagnetic wave generated from both radar system and generator group in operation caused any performance deterioration to each other. As a result, it was confirmed that the performance deterioration due to electromagnetic wave inflow, radiation, and conduction did not occur. It is expected that it should be possible to provide high efficiency power supply and stable power supply by applying to various military system as well as radar system.

Evaluation of Habitat Suitability of Major Honey Trees in the Mt. Gariwang and Mt. Yumeong through Machine Learning Approach (머신러닝기법을 활용한 가리왕산과 유명산 지역 주요 밀원수의 서식지 적합성 평가)

  • Yong-Ju Lee;Min-Ki Lee;Hae-In Lee;Chang-Bae Lee;Hyeong-Seok Sim
    • Korean Journal of Agricultural and Forest Meteorology
    • /
    • v.25 no.4
    • /
    • pp.311-325
    • /
    • 2023
  • This study was conducted to analyze the habitat suitability of the major honey trees including Kalopanax septemlobus Koidz., Prunus spp., Tilia spp., and Styrax obassia Siebold & Zucc. indigenous to mountain Gariwang and Yumeong using the machine learning approach (i.e., MaxEnt model). The AUC values of the model predictions were mostly above 0.7, and the results of the response curves showed that the environmental drivers that had effects on the habitat suitability of the major honey trees were elevation, mean annual precipitation, and mean annual temperature. These results indicate that climatic drivers along the elevation gradient are the main environmental drivers in explaining the distribution patterns of the major honey trees. In addition, the results of the response curves of Prunus spp. and Styrax obassia Siebold & Zucc. differed slightly in terms of slope and mean annual solar radiation as the main environmental drivers. The results of this study will be valuable for the establishment of honey tree forests and management plans for the natural and artificial forests in South Korea, as well as for the mapping the distribution of honey trees. Further studies at different regional levels, reflecting biotic drivers, will be needed to expand the production of honey and pollen at different strata and to produce honey annually.

Spatio-temporal Fluctuations of Size-structured Phytoplankton over an Annual Cycle in the Youngsan Lake

  • Song, Eun-Sook;Shin, Yong-Sik
    • Korean Journal of Ecology and Environment
    • /
    • v.41 no.4
    • /
    • pp.530-540
    • /
    • 2008
  • The temporal and spatial variations of size-structured phytoplankton dynamics in Youngsan Lake were investigated to explore potential mechanims controlling the dynamics in the Youngsan Lake. Field data were collected monthly from February to October, 2003 at 6 stations along the axis of Youngsan Lake. In this study, phytoplankton (chlorophyll $\alpha$) were categorized into three size classes: micro-size ($>20{\mu}m$), nano-size ($2{\sim}20{\mu}m$) and pico-size ($<20{\mu}m$). Water temperature, light attenuation coefficients, PAR (photosynthetically active radiation) and suspended solids were measured to analyze relationship between physical-chemical properties and size structure of phytoplankton. Phytoplankton blooms developed during March, July and October in the upper region of the main stem whereas small-scaled spring bloom was observed in the lower region. The scales of phytoplankton blooms were higher in the upper regions than the lower region and blooms were predominated by micro-size class in upper region but predominated by nano-size class in lower region. Growth of size-structured phytoplankton appeared to be controlled by rather light availability than temperature-dependant metabolisms in the system. Phytoplankton growth may be also supported by ambient nutrients available in the water column from analyses of chlorophyll $\alpha$ vs. nutrient concentrations including nitrite+nitrate and orthophosphate. Growth of nano-sized phytoplankton alone appeared to be supported by orthophosphate as well as nitrite+nitrate indicating that response of phytoplankton to nutrient inputs may be size-dependent.

Response of the Geomagnetic Activity Indices to the Solar Wind Parameters

  • Ahn, Byung-Ho;Park, Yoon-Kyung
    • Journal of Astronomy and Space Sciences
    • /
    • v.25 no.2
    • /
    • pp.129-138
    • /
    • 2008
  • This study attempts to show how the geomagnetic indices, AU, AL and Dst, respond to the interplanetary parameters, more specifically, the solar wind electric field VBz during southward interplanetary magnetic field (IMF) period. The AU index does not seem to respond linearly to the variation of southward IMF. Only a noticeable correlation between the AU and VBz is shown during summer, when the ionospheric conductivity associated with the solar EUV radiation is high. It is highly likely that the effect of electric field on the eastward electrojet intensification is only noticeable whenever the ionospheric conductivity is significantly enhanced during summer. Thus, one should be very cautious in employing the AU as a convection index during other seasons. The AL index shows a significantly high correlation with VBz regardless of season. Considering that the auroral electrojet is the combined result of electric field and ionospheric conductivity, the intensification of these two quantities seems to occur concurrently during southward IMF period. This suggests that the AL index behaves more like a convection index rather than a substorm index as far as hourly mean AL index is concerned. Contrary to the AU index, the AL index does not register the maximum value during summer for a given level of VBz. It has something to do with the findings that discrete auroras are suppressed in sunlight hemisphere (Newell et al. 1996), thus reducing the ionospheric conductivity during summer. As expected, the Dst index tends to become more negative as VBz gets intensified. However, the Dst index (nT) is less than or equal to 15VBz(mV/m) + 50(Bz < 0). It indicates that VBz determines the lower limit of the storm size, while another factor(s), possibly substorm, seems to get further involved in intensifying storms. Although it has not been examined in this study, the duration of southward IMF would also be a factor to be considered in determining the size of a storm.

One-way Coupled Response Analysis between Floating Wind-Wave Hybrid Platform and Wave Energy Converters (부유식 풍력-파력발전 플랫폼과 탑재된 파력발전기와의 단방향 연성 운동 해석)

  • Lee, Hyebin;Bae, Yoon Hyeok;Cho, Il-Hyoung
    • Journal of Ocean Engineering and Technology
    • /
    • v.30 no.2
    • /
    • pp.84-90
    • /
    • 2016
  • In this study, a six degree-of-freedom motion analysis of a wind-wave hybrid platform equipped with numerous wave energy converters (WECs) was carried out. To examine the effect of the WECs on the platform, an analysis of one-way coupling was carried out, which only considered the power take-off (PTO) damping of the static WECs on the platform. The equation of motion of a floating platform with mooring lines in the time domain was established, and the responses of the one-way coupled platform were then compared with the case of a platform without any coupling effects from the WECs. The hydrodynamic coefficients and wave exciting forces were obtained from the 3D diffraction/radiation pre-processor code WAMIT based on the boundary element method. Then, an analysis of the dynamic responses of the floating platform with or without the WEC effect in the time domain was carried out. All of the dynamics of a floating platform with multiple wind turbines were obtained by coupling FAST and CHARM3D in the time domain, which was further extended to include additional coupled dynamics for multiple turbines. The analysis showed that the PTO damping effect on platform motions was negligible, but coupled effects between multiple WECs and the platform may differentiate the heave, roll, and pitch platform motions from the one without any effects induced by WECs.