• Title/Summary/Keyword: radiation power

Search Result 1,954, Processing Time 0.024 seconds

Comparison Between Radiation Power and Beamforming Power of plate (평판에서의 음향 방사파워와 구면파 모델을 이용한 빔형성 파워와의 비교)

  • Kim, Young-Key;Kim, Yang-Hann
    • The Journal of the Acoustical Society of Korea
    • /
    • v.16 no.6
    • /
    • pp.12-18
    • /
    • 1997
  • Beamforming method has a limited spatial resolution because of finite aperture size, so that the estimated source distributions are smoothed within the resolution. Especially for low frequency noise such as mechanical noise, this limitation often diminishes the direct use of beamforming method. In this study, the relation between smoothed beamforming and radiation power distribution of plate has been addressed. By adjustment of aperture size of array, the smoothed beamforming power shows radiation power distribution of plate. Numerical simulations are carried for simply supported plate.

  • PDF

Remote Nozzle Blocking Device of RCS Pipe during Mid-Loop Operation in Nuclear Power Plants

  • Kang, Ki-Sig;Lee, Se-Yub;Chi, Ham-Chung
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 1996.05a
    • /
    • pp.571-576
    • /
    • 1996
  • Currently most nuclear power plants(NPPs) are adopted the mid-loop operation to minimize the overhaul period and save the operating cost. For mid-loop operation it is essential to install nozzle dam between RCS pipe and steam generator(SG). Because SG remains more highly contaminated with radioactive material than any other parts of the NPPs, the repairmen are very reluctant to carry out installing nozzle dam inside the SG. Until now, unfortunately, it appears that no practically applicable device was developed to provide the longstanding demand. Also the accidents have been reported by licenser event report during this operation mode due to loss of residual heat removal(RHR). The purpose of this paper is to conduct remotely blocking and disintegration of nozzle of a SG which has the highest radiation exposure during the maintenance in NPPs. The remote nozzle blocking device of a SG includes three bladders, hubs, air controller provisions to supply and contact air pressure into the bladders. This remote nozzle block device will give the larger operation margin to prevent the loss of RHR and minimize the radiation exposure dose to the repairman and shorten the overhaul periods.

  • PDF

Substrate Integrated Waveguide Power Divider Fed Dual-Dipole Array Antenna

  • Yu, Chen;Hong, Wei;Kuai, Zhenqi
    • Journal of electromagnetic engineering and science
    • /
    • v.10 no.3
    • /
    • pp.171-174
    • /
    • 2010
  • In the paper, a printed dual-dipole array antenna is presented. A 4-way planar SIW power divider is adopted for feeding the array antenna. The dual-dipole is adopted as radiation elements which greatly improves the impedance band. The measured bandwidth larger than 31 % for VSWR$\leq$1.5 operating near 14 GHz is achieved and in agreement with the simulated results. The radiation E-plane and H-plane radiation pattern is presented in the paper. The radiation gain is also presented in the paper.

A Study on the Radiation Pattern Measurement Technique of Shipboard Antenna (함정 탑재 안테나의 복사패턴 측정기법 연구)

  • 정회인
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.4 no.1
    • /
    • pp.177-187
    • /
    • 2001
  • It is important to test and evaluate the variation degree of ship-mounted antenna radiated power with respect to all directions in order to use more effectively antennas that installed on naval ships. The naval ship has various sensors for navigation, communication and electronic warfare, etc. And the performance of these sensors extremely depends on the various characteristics of antenna system to transmit and receive electromagnetic wave. The radiated power pattern of the antenna differs from all aspect angles of the ship because of complex superstructures. It is important to know the weak point(direction) of antenna radiation for appropriate operation. Therefore, the ARP(Antenna Radiation Pattern) of shipboard antennas is measured for the all aspect angles. The results of ARP measurement are utilized as reference for antenna arrangement of newly-built same class warship. This study also describes the development results for the ARP measurement technique, software design and test procedures to measure the radiation pattern of communication equipment antennas using the fixed test site.

  • PDF

The research of the UWB system radiation measurement (UWB 시스템의 방사출력 측정방법 연구)

  • Song, Hong-Jong;Cha, Jae-Sang
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.10 no.5
    • /
    • pp.277-286
    • /
    • 2010
  • In this paper we analyse radiation measurement method for UWB wireless system of the wideband low power frequency characteristics. In the radiation measurement environment we discuss RMS electric field strength, UWB PSD, UWB detect signal level, UWB noise signal collection etc.. also, we discuss power measure method of the CISPR16-1, low level e.i.r.p radiation measurement method. lastly we analyse consideration problem for the signal analyser of the UWB system.

DEVELOPMENT OF A FRAMEWORK FOR ASSESSING RADIATION SOURCE TERMS IN NUCLEAR POWER PLANTS

  • Jae, Moo-Sung;Park, Shane;Kang, Kyung-Min;Jeun, Gyoo-Dong
    • Journal of Radiation Protection and Research
    • /
    • v.26 no.3
    • /
    • pp.197-201
    • /
    • 2001
  • A risk analysis consists of a triplet, , where Si is the scenario identification; Pi is the probability of each scenario; and Xi is the consequences of each scenario. A new computing framework, OMAM (ORIGEN-MAAP4-MMCS), has been developed and applied for assessing the risk of a reference plant as well as radiation source terms using the concept of risk triplet. The result of this study using the OMAM framework presented in this paper, can contribute to producing domestic nuclear power plant's risk data base as well as to establishing severe accident management plans.

  • PDF

Radiation power estimation for the planar array acoustic sensor considering mutual coupling effects (상호간섭영향을 고려한 평면배열형 음향센서의 방사출력 예측)

  • Lee, Jong-Kil;Seo, In-Chang
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.2 no.3
    • /
    • pp.194-199
    • /
    • 1996
  • 평면 배열형 소나 센서에서는 트랜스듀서 상호간의 간섭효과들이 음을 방사하는 각각의 트랜스듀서 및 평면 배열의 빔패턴에 영향을 주게된다. 따라서 음향 방사출력의 계산은 소나용 트랜스듀서의 성능및 효율을 평가하는데 필수적이다. 음향 방사출력을 예측하기 위하여 무한 강성 배플에 고정된 수개의 트랜스듀서를 이론해석의 대상으로 설정하였다. 각 트랜스듀서는 자기방사 임피던스 및 상호방사 임피던스로 구성되어 있으며 이것의 총 방사 임피던스 및 음향반사 출력의 추출은 등가 전기회로 모델을 이용하였다. 이론및 수치해석의 결과에 근거하여 음향방사 출력은 각 트랜스듀서 상호간의 간섭의 양에 의존함을 보였으며 상호간섭에 의한 음향출력 손실은 25.05%에서 최고 51.52%정도임을 확인하였다.

  • PDF

Radiation damage to Ni-based alloys in Wolsong CANDU reactor environments

  • Kwon, Junhyun;Jin, Hyung-Ha;Lee, Gyeong-Geun;Park, Dong-Hwan
    • Nuclear Engineering and Technology
    • /
    • v.51 no.3
    • /
    • pp.915-921
    • /
    • 2019
  • Radiation damage due to neutrons has been calculated in Ni-based alloys in Wolsong CANDU reactor environments. Two damage parameters are considered: displacement damage, and transmutation gas production. We used the SPECTER and SRIM computer codes in quantifying radiation damage. In addition, damage caused by Ni two-step reactions was considered. Estimations were made for the annulus spacers in a CANDU reactor that are located axially along a fuel channel and made of Inconel X-750. The calculation results indicate that the transmutation gas production from the Ni two-step reactions is predominant as the effective full power year increases. The displacement damage due to recoil atoms produced from Ni two-step reactions accounts for over 30% out of the total displacement damage.

The Study on the Way of Radioactive Waste Disposal in China

  • Keyan Teng;Hao Peng;Caixia Lv;Han Wu
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.20 no.4
    • /
    • pp.533-540
    • /
    • 2022
  • Because of the massive development of nuclear power plants in China in recent years, China is facing the challenge of radioactive waste disposal. China has established complete regulatory requirements for radioactive waste disposal, but it also has encountered problems and challenges in low-level radioactive waste disposal in terms of management, selection of disposal facility sites, and implementation of a site selection plan. Three low-level radioactive waste disposal facilities that have been operated in China are described, and their activity limits, locations, and capacities are also outlined. The connotations of "regional" and "centralized" disposal policies are discussed in light of the characteristics of the radioactive waste. The characteristics and advantages of the regional and centralized disposal policies are compared. It is concluded that the regional disposal policy adopted in 1992 can no longer meet the current disposal needs, and China should adopt a combination of the two disposal policies to solve the problem of radioactive waste disposal.

Development of Highly Reliable Power and Communication System for Essential Instruments Under Severe Accidents in NPP

  • Choi, Bo Hwan;Jang, Gi Chan;Shin, Sung Min;Lee, Soo Ill;Kang, Hyun Gook;Rim, Chun Taek
    • Nuclear Engineering and Technology
    • /
    • v.48 no.5
    • /
    • pp.1206-1218
    • /
    • 2016
  • This article proposes a highly reliable power and communication system that guarantees the protection of essential instruments in a nuclear power plant under a severe accident. Both power and communication lines are established with not only conventional wired channels, but also the proposed wireless channels for emergency reserve. An inductive power transfer system is selected due to its robust power transfer characteristics under high temperature, high pressure, and highly humid environments with a large amount of scattered debris after a severe accident. A thermal insulation box and a glass-fiber reinforced plastic box are proposed to protect the essential instruments, including vulnerable electronic circuits, from extremely high temperatures of up to $627^{\circ}C$ and pressure of up to 5 bar. The proposed wireless power and communication system is experimentally verified by an inductive power transfer system prototype having a dipole coil structure and prototype Zigbee modules over a 7-m distance, where both the thermal insulation box and the glass-fiber reinforced plastic box are fabricated and tested using a high-temperature chamber. Moreover, an experiment on the effects of a high radiation environment on various electronic devices is conducted based on the radiation test having a maximum accumulated dose of 27 Mrad.