• 제목/요약/키워드: radiation mode

검색결과 487건 처리시간 0.034초

전기-음향 방사컨덕턴스를 이용한 치료용 초음파 자극기의 음향출력 예측 (The Acoustic Output Estimation for Therapeutic Ultrasound Equipment using Electro-Acoustic Radiation Conductance)

  • 윤용현;조문재;김용태;이명호
    • 대한의용생체공학회:의공학회지
    • /
    • 제32권3호
    • /
    • pp.264-269
    • /
    • 2011
  • To increase therapeutic efficiency and biological safety, it is important to precision control of acoustic output for therapeutic ultrasound equipment. In this paper, the electro-acoustic radiation conductance, one of electroacoustic characteristics of therapeutic ultrasound equipment, was measured by the radiation force balance method according to IEC 61161 standards and the acoustic output was estimated using the electro-acoustic radiation conductance. The estimation of acoustic output was conducted to continuous wave mode and pulse wave mode of duty cycle between 20% and 80%. The differences between prediction values and measurement results are within 5% of measurement uncertainty, which is a reasonably good agreement. The results show that acoustic output controlled by electro-acoustic radiation conductance was found to be an effective method.

치과용 이동형 방사선장치의 선량평가 (Evaluation of Radiation Doses of Dental Portable Equipment)

  • 박훈희;강병삼
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제41권5호
    • /
    • pp.445-450
    • /
    • 2018
  • We aim to evaluate safety of radiation by measuring leakage dose and patient(phantom) incident dose of ZEN-PX II dental portable equipment developed by G company. Measurement for leakage dose of equipment is conducted on the top, at the bottom, on the left, on the right and at the back. Dose measurement incident on the subject with the area dosimeter when using the phantom and measurement the leakage dose of equipment when using the phantom are evaluated. Comparing the right with the highest leakage dose as a 0 cm, 25 cm, 50 cm, 75 cm and 100 cm dose measurement at the measurement height of 100 cm, 64.2 uR was reduced to 47.3 uR in the senser mode 0.32sec. Even in film mode it was measured at 414.4 uR and about 27% lower at 162.6 uR. As the result of this study, when the irradiation time is 2 sec the right side dose is 290.5 uR and sensor mode is 0.32 sec the right side dose is 64.2 uR.

CAE를 이용한 파워트레인의 방사소음 저감을 위한 구조변경 (Structural Modification for the Reduction of Radiation Noise of a Powertrain Based on CAE Technology)

  • 송민근;오기석;이상권
    • 한국소음진동공학회논문집
    • /
    • 제18권4호
    • /
    • pp.439-447
    • /
    • 2008
  • One of the key elements in efforts to minimize noise radiation from a powertrain is the knowledge of the main radiating component and the relation between the surface vibration of a powertrain and the sound pressure. In this research, the powertrain model is developed based on FEM(finite element method). This model is applied to the prediction of the vibration of a powertrain by using ADAMS and the radiation noise by using BEM(boundary element method). According to this numerical analysis, the surface vibration of a powertrain is investigated as a source of radiated noise. This surface vibration is caused by the 1st order natural vibration of the cylinder block and its mode shape is the torsion mode. Therefore, this mode shape is modified to reduce the surface vibration of the powertrain. The radiation noise of the modified powertrain is also reduced to $5{\sim}12\;dB$. This modification is very successful for the noise reduction based on the CAE technology.

악성종양의 광역학적 치료를 위한 레이저 시스템의 최적화 (The Otimization of Laser System for Photodynamic Therapy of Malignancies)

  • 임현수;김주옥;황인경
    • 전자공학회논문지SC
    • /
    • 제41권6호
    • /
    • pp.51-60
    • /
    • 2004
  • 본 논문은 광역학적 암치료 효율을 높이기 위한 레이저 시스템의 최적화 구현에 관한 연구이다. 레이저 시스템의 최적화를 위해서는 레이저 출력의 출력 변동율과 파장대의 편이가 적어야 한다. 임상에서 암치료의 효율을 높이기 위해서는 악성종양부위에 조사되는 방사방식이 다양하게 구현되어야 한다. 기존에 사용되고 있는 C.W 방식은 정상조직에도 손상을 입힐 수 있는 생체조직의 열적효과를 가져올 수 있다. 이에 새로운 방사모드를 제안하여 생체조직에 대한 열적 안전성과 치료의 효율을 높였다. 실험을 통하여 광파장의 안정성 및 광 출력과 출력의 안정성을 확인 하였고, 피부조직의 열적 손상 방지를 위한 방사모드의 구현은 생체조직에 대한 실험을 통해서 본 연구의 타당성을 검증하였다.

디지털 유방확대촬영술에서 노출방식에 따른 피폭선량 평가 (The Evaluation of Radiation Dose by Exposure Method in Digital Magnification Mammography)

  • 김미영;김화선
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제35권4호
    • /
    • pp.293-298
    • /
    • 2012
  • 디지털 유방촬영술은 유방의 두께 및 유선조직의 밀도에 따라 노출조건이 자동으로 이루어지는 자동노출제어장치를 사용하고 있는데 이는 피폭선량을 증가시키는 원인이 되기도 한다. 이 연구에서는 디지털 유방확대촬영술에서 영상의 질을 유지하며 불필요한 방사선 피폭을 줄이기 위한 최적의 방사선량 촬영조건을 알아보았다. 자동노출방식을 사용할 경우 가장 좋은 영상화질을 얻을 수 있었으나 평균유선선량 역시 가장 높았다. 수동노출방식의 경우 자동노출방식의 55 % 정도의 mAs 값만으로도 기준 팬텀영상 점수와 신호대잡음비를 얻을 수 있으며 평균유선선량은 55 % 이하로 줄일 수 있었다. 위와 같은 결과를 참고로 하면 디지털 유방확대촬영 시 자동노출방식보다는 수동노출방식을 이용함으로써 불필요한 환자의 피폭선량을 줄일 수 있을 것이라 생각된다.

방사선 치료위치 검증을 위한 다이오드 검출기의 특성에 관한 연구 (A Study on Characteristics of Diode Detecter for Verification of Radiation Therapy)

  • 이동훈;김윤종;지영훈;이동한;홍승홍
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2000년도 하계종합학술대회 논문집(5)
    • /
    • pp.106-109
    • /
    • 2000
  • The diode characteristics for therapy radiation sensor have been studied by irradiating therapy radiation from the MM22 microtron accelerator. Signal processing has been performed in the pulse mode which can process the signal fast. We have designed integrator, peak detector and synchronization circuit to detect diode signal in the pulse mode for implementation of portal image. We also read the diode signal by A/D board and displayed the peak value with LabView program. Because the quality of portal image obtained by film in the case of therapy radiation is much worse than that of diagnostic film, Digital radiography system by rectifier diode detector was suggested for portal Image.

  • PDF

감마선 조사에 의한 광섬유의 전송손실 특성변화에 관한 연구 (A Study on the Radiation-Induced Loss of Optical Fiber by ${\gamma}$-ray Irradiation)

  • 김웅기;이용범;이종민
    • 대한전자공학회논문지
    • /
    • 제27권4호
    • /
    • pp.604-611
    • /
    • 1990
  • One of the confronting problems in using optical fibers under radiation environments is producing of color centers in optical materials due to nuclear radiation. These centers increase transmission loss by absorbing propagating light. In this study, the radiation effects on optical fiber are studied theoretically. Also, optical attenuation induced by \ulcorner-ray irradiation from Co**60 for single mode and multimode optical fibers is measured at the optical wavelength of 0.85\ulcorner and 1.3\ulcorner, and the results are analyzed. Gammaray is irradiated for 5hours at the rate of 300rads/min, which is corresponding to 90 krads of integrated dose. In case of multimode optical fibers, the induced loss at 0.85\ulcorner wavelength has been twice higher than that at 1.3\ulcorner. The loss in multimode fibers has been significantly larger by 7-20 times than that in single mode fibers, dependently on fiber materials at 1.3\ulcorner.

  • PDF

공동을 지나는 비정상 유동에 의한 소음 방사 해석 (Numerical Investigation of Sound Generation in the Flow Past a Cavity)

  • 허대영;이덕주
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2000년도 춘계학술대회논문집
    • /
    • pp.104-109
    • /
    • 2000
  • The modes of oscillation and radiated acoustic fields of compressible flows over open cavities are investigated computationally. The compressible Navier-Stokes equations are solved for two-dimensional cavities with laminar boundary layers upstream. The high-order and high-resolution numerical schemes are used for the evaluation of spatial derivatives and the time integration. Physically correct numerical boundary conditions are implemented to produce time-accurate solutions in the whole computation domain. The computational domain is large enough to directly resolve a portion of the radiated acoutic field. The results show a transition from a shear layer mode, for shorter cavities and lower Mach numbers, to a wake mode for longer cavities and higher Mach numbers. The shear layer mode is well characterized by Rossiter modes and these oscillations lead to intense upstream acoustic radiation dominated by a single frequency. The wake mode is characterized instead by a large-scale vortex shedding. Acoustic radiation is more intense, with multiple frequencies present.

  • PDF

구조물의 고유특성 제어를 통한 방사 소음 저감 (Reduction of Radiated Noise by Eigen-property Control)

  • 최성훈
    • 한국음향학회지
    • /
    • 제23권5호
    • /
    • pp.376-382
    • /
    • 2004
  • 구조물의 의해 방사되는 음향파워는 구조물의 진동특성에 의해 결정된다. 방사소음을 저감하는 가장 간단명료한 방법으로는 구조물의 진동을 최소화하는 방법이 있다. 하지만 구조물의 진동모드 각각은 방사효율이 다르기 때문에 이를 고려하여 진동모드를 제어하면 효율적으로 방사소음을 저감할 수 있다. 본 연구에서는 피드포워드 제어를 적용하여 구조물의 고유특성을 변화시켜 진동 모드의 방사효율을 저감하는 방법을 제안한다. 단순지지 빔에 대한수치모사를 통해 진동모드의 체적속도를 최소화하는 제어 변수를 결정하였고, 이러한 제어를 적용하면 저주파 영역에서 방사소음을 크게 줄일 수 있다는 것을 보여 준다.

E/H 평면 방사 패턴 대칭성 향상을 위해 개구면이 변형된 원형 이중 모드 혼 안테나 (Circular Dual Mode Horn Antenna(CDMHA) with Modified Aperture to Improve E/H-Plane Radiation Pattern Symmetry)

  • 김재식;윤지환;윤영중;이우상;소준호
    • 한국전자파학회논문지
    • /
    • 제24권5호
    • /
    • pp.502-507
    • /
    • 2013
  • 본 논문에서는 개구면이 큰 기존 원형 이중 모드 혼의 E/H 평면 방사 패턴 대칭성 향상을 위한 변형된 개구면을 갖는 원형 이중 모드 혼을 제안한다. 제안된 안테나는 급전부, 모드 발생부, 위상정합부로 구성되며, 이 중 위상정합부의 원형 개구면은 E/H 평면의 방사 패턴 대칭성 향상을 위해 타원형 혹은 직사각형으로 변이된 형상을 갖는다. 제안된 안테나와 기존 원형 이중 모드 혼의 성능 비교를 위해 15 GHz에서 동작하는 기존 원형 이중모드 혼과 직사각형 개구면을 갖는 원형 이중 모드 혼을 제작하고 분석하였다. 측정 결과, f/d 비가 1인 반사판 안테나의 최대 개구 효율을 위한 급전 혼의 빔 폭인 -11 dB 빔 폭($53^{\circ}$) 내에서 기존 원형 이중 모드 혼의 경우 3.394 dB의 E/H 평면 방사 패턴 차이를 갖는 반면, 제안된 안테나는 오직 0.539 dB 차이를 가진다.