• 제목/요약/키워드: radiation heat flux

검색결과 251건 처리시간 0.021초

석유류 저장 탱크에서의 액면 및 유츌화재에 대한 복사열의 실험적 연구 (Experimental Study of Radiation Heat Flux for the Pool and Spill Fire in Petroleum Storage Tanks)

  • 김홍;박형주
    • 한국안전학회지
    • /
    • 제19권1호
    • /
    • pp.88-93
    • /
    • 2004
  • This experimental study was carried out to evaluate effect of the radiation heat flux for the pool and spill fire in petroleum storage tanks, which were made form steel. Each of them had the capacity of 250, 2500 and 25000 liter, respectively. The effects of the radiation heat flux are as follows; 1) The intensity of radiation heat flux from a flame decreased exponentially with increasing distance from outside wall of tanks, and increased significantly with surface area of tank and dyke. 2) In the case of 25000L tank, the radiation heat flux was about max. 98.9kW/$m^2$ in 1m from wall of tank. 3) The distance, that was able to ignite wood or plastics by radiation heat flux of approximately 12.5kW/$m^2$, was about 3.14m from wall of 25000L tank.

기상 조건에 따른 도시 캐노피 모형의 성능 비교 (Performance Comparison of an Urban Canopy Model under Different Meteorological Conditions)

  • 유영희;백종진;이상현
    • 대기
    • /
    • 제22권4호
    • /
    • pp.429-436
    • /
    • 2012
  • The performances of the Seoul National University Urban Canopy Model (SNUUCM) under different meteorological conditions (clear, cloudy, and rainy conditions) in summertime are compared using observation dataset obtained at an urban site. The daily-averaged net radiation, sensible heat flux, and storage heat flux are largest in clear days and smallest in rainy days, but the daily-averaged latent heat flux is similar among clear, cloudy, and rainy days. That is, the ratio of latent heat flux to net radiation increases in order of clear, cloudy, and rainy conditions. In general, the performance of the SNUUCM is better in clear days than in cloudy or rainy days. However, the performance in simulating sensible heat flux in clear days is as poor as that in rainy days. For all the meteorological conditions, the performance in simulating latent heat flux is worst among the performances in simulating net radiation, sensible heat flux, and latent heat flux. The normalized mean error for latent heat flux is largest in rainy days in which the relative importance of latent heat flux in the surface energy balance becomes greatest among the three conditions. This study suggests that improvements to the parameterization of processes that are related to latent heat flux are particularly needed.

함평만 갯벌에서 순복사에 의한 토양열 플럭스와 기온의 변동 분석 (Analysis of Variations in Soil Heat Flux and Air Temperature by Net Radiation at a Mud Flat in Hampyeong Bay)

  • 박호선;권병혁;김일규;소윤환;오세봉;강동환
    • 한국환경과학회지
    • /
    • 제26권9호
    • /
    • pp.1101-1110
    • /
    • 2017
  • In this study, we analyze changes in soil heat flux and air temperature in August (summer) and January (winter) according to net radiation, at a mud flat in Hampyeong Bay. Net radiation was observed as $-84.2{\sim}696.2W/m^2$ in August and $-79.4{\sim}352.5W/m^2$ in January. Soil heat flux was observed as $-80.7{\sim}139.5Wm^{-2}$ in August and $-49.09{\sim}137W/m^2$ in January. Air temperature was observed as $24.2{\sim}32.9^{\circ}C$ in August and $-1.5{\sim}11.1^{\circ}C$ in January. The rate of soil heat flux for net radiation ($H_G/R_N$) was 0.17 in August and 0.34 in January. Because the seasonal fluctuation in net radiation was bigger than the soil heat flux, net radiation in August was bigger than in January. We estimated a linear regression function to analyze variations in soil heat flux and air temperature by net radiation. The linear regression function and coefficient of determination for the soil heat flux by net radiation was y=0.19x-7.94, 0.51 in August, and y=0.39x-11.69, 0.81 in January. The time lag of the soil heat flux by net radiation was estimated to be within ten minutes in August 2012 and January 2013. The time lag of air temperature by net radiation was estimated at 160 minutes in August, and 190 minutes in January.

Introduction of Japanese Ocean Flux data sets with Use of Remote sensing Observations (J-OFURO)

  • Kubota, Masahisa
    • 대한원격탐사학회:학술대회논문집
    • /
    • 대한원격탐사학회 1999년도 Proceedings of International Symposium on Remote Sensing
    • /
    • pp.231-236
    • /
    • 1999
  • Accurate ocean surface fluxes with high resolution are critical for understanding a mechanism of global climate. However, it is difficult to derive those fluxes by using ocean observation data because the number of ocean observation data is extremely small and the distribution is inhomogeneous. On the other hand. satellite data are characterized by the high density, the high resolution and the homogeneity. Therefore, it can be considered that we obtain accurate ocean surface by using satellite data. Recently we constructed ocean surface data sets mainly using satellite data. The data set is named by Japanese Ocean Flux data sets with Use of Remote sensing Observations (J-OFURO). Here, we introduce J-OFURO. The data set includes shortwave radiation, longwave radiation, latent heat flux, sensible heat flux, and momentum flux etc. Moreover, sea surface dynamic topography data are included in the data set. Radiation data sets covers western Pacific and eastern Indian Ocean because we use a Japanese geostationally satellite (GMS) to estimate radiation fluxes. On the other hand, turbulent heat fluxes are globally estimated. The constructed data sets are used and shows the effectiveness for many scientific studies.

  • PDF

온돌면(溫突面)의 방열량(放熱量) 산정방법(算定方法)에 관한 연구(硏究) (A Calculation Method on Heat Flux from Ondol Floor Surface)

  • 손장열;안병욱;방승기
    • 설비공학논문집
    • /
    • 제1권2호
    • /
    • pp.173-181
    • /
    • 1989
  • Until recently there was a lack of reliable performance data for the design and operation of Ondol heating systems. This paper presents a calculation method on heat flux from Ondol floor surface. Total heat flux from floor consists of radiation and convection component. In order to analyse the characteristics of both radiation and convection heat flux, each surface temperature is measured and several temperatures near each wall are measured vertically and horizontally in a practical Ondol heating space. Radiation heat flux is calculated and analysed by Gebhart's Absorption Factor Method with the consideration of instantaneous radiant exchanges. Convection heat output is derived from the vertical temperature profiles near floor. The vertical temperature profiles could be expressed by nonlinear regression equation models and convection coefficients could be estimated by the equations. As a result, radiation, convection and total heat flux are suggested by the expression of difference between floor surface and room air temperature.

  • PDF

건물과 수목의 그림자에 의한 도시의 열 분포 산정 및 저감효과 연구 (Estimating the urban radiation heat flux distribution and the reduction effect of building and tree shade)

  • 박채연;이동근;윤준하
    • 한국환경복원기술학회지
    • /
    • 제21권6호
    • /
    • pp.1-13
    • /
    • 2018
  • Mapping radiation heat flux of urban area is essential for urban design and landscape planning. Because controlling urban geometry and generating green space are important urban design strategies for reducing urban heat, urban planner and designer need to recognize the micro urban heat distribution for adequate urban planning. This study suggests a new methodology for mapping urban radiation heat flux in a micro scale considering buildings and trees' shade. For doing that, firstly, we calculate net radiation for each urban surfaces (building, road (not shaded, building shaded, tree shaded), ground (not shaded, building shaded, tree shaded), tree (not shaded, building shaded)). Then, by multiplying the area ratio of surfaces to the net radiation, we can obtain the radiation heat flux in micro-scale. The estimated net radiation results were found to be robust with a $R^2$ of 90%, which indicates a strong explanatory power of the model. The radiation heat flux map for 12h $17^{th}$ August explains that areas under the building and tree have lower net radiation heat flux, indicating that shading is a good strategy for reducing incident radiation. This method can be used for developing thermal friendly urban plan.

위성자료를 이용한 한반도 주변 해상 대기표층의 열속 (Heat Fluxes in the Marine Atmospheric Surface Layer around the Korean Peninsula based on Satellite Data)

  • 홍기만;권병혁;김영섭
    • 수산해양교육연구
    • /
    • 제17권2호
    • /
    • pp.209-217
    • /
    • 2005
  • The energy balance of the surface layer of the water (the Yellow Sea, the East China Sea and the East Sea) was examined using satellite data. Variations of the net heat flux were similar to those of the latent heat flux which was more intensive than the sensible heat flux. The sensible heat flux was affected the difference between the sea surface temperature and the air temperature and was less important over the Yellow Sea. The maximum of the latent heat flux occurred in autumn when the air is drier and the wind is stronger. The shortwave radiation flux decreased with the latitude and depended on the cloudiness as the longwave radiation flux does. Annual variations of heat fluxes show that the latent heat flux was more intensive over the East China Sea than the East Sea and the Yellow Sea, while the spatial differences of the other heat fluxes were weak.

제주도 북부해역의 표면 열수지 해석 -1993년과 1994년 하계의 경우- (Surface Heat Budget of the Northern Sea of Cheju Island for June-August 1993 and 1994)

  • 김해동;양성기
    • 한국환경과학회지
    • /
    • 제4권3호
    • /
    • pp.197-206
    • /
    • 1995
  • Surface heat balance of the northern sea of Cheju Island for summer in 1993 and 1994 is analyzed using the observation data obtained by Marine Research Institute, Cheju National University. Each flux elements at the sea surface is derived from the marine meteorological reports with application of an aerodynamical bulk method for the turbulent heat fluxes, and empirical formulae for the long-wave radiation heat fluxes. The flux divergence of oceanic heat transport and the rate of heat storage in the ocean are estimated as residual. The features of the surface heat balance are mainly decided by the solar radiation flux and the latent heat flux for 199B. But the Bowen Ratios were large for 1993. This means that the sensible heat fluxes were nearly equal to the latent heat fluxes for 1993. In this period, mean flux divergence of oceanic heat transport is about 130 W/$m^2$.

  • PDF

고흥만 습지에서 증발산량의 산출 방법 (Estimation Method of Evapotranspiration over Goheung bay Wetland)

  • 권병혁;김동수;김근회;강동환
    • 한국습지학회지
    • /
    • 제10권1호
    • /
    • pp.21-30
    • /
    • 2008
  • 증발산은 지표와 대기 사이에서 일어나는 에너지 상호작용에 기여하는 중요한 요소 중 하나이다. 갈대로 덮인 고흥만 간척지에서 현열, 토양열 그리고 순복사를 측정하여 증발산량을 조사하였다. 자동기상관측 자료로부터 산출된 증발산량은 구름과 바람의 연직경도가 $1s^{-1}$보다 미약한 경우를 제외하고 열수지 방정식으로 추정한 값과 잘 일치하였다. 토양열은 순복사의 약 10%로 평가되었다. 갈대로 구성된 식생캐노피 내에서 온도에 따른 포화수증기압의 변화율($${\Delta}{\sim_=}de_s/dT$$)이 약 1.5로 근사되었고, 증발산량은 순복사 에너지의 함수로 설명될 수 있다.

  • PDF

낙동강 구미 보의 수면 열수지 계절 변화 (Seasonal Variation of the Surface Heat Budget in the Gumi Reservoir of Nakdong River)

  • 김학윤;서광수;조창범;김해동
    • 한국환경과학회지
    • /
    • 제25권8호
    • /
    • pp.1057-1063
    • /
    • 2016
  • The heat budget is investigated in the Gumi Reservoir of the Nakdong river. In warm climate season, solar radiation effects play a important role in the change of water temperature. The features of the surface heat balance are almost derived by the latent heat flux and the solar radiation flux. On the other hand, in cold climate season, change of heat stored in the water is mainly dominated by latent and sensible heat transfer between water and air, since flux of solar radiation and loss of outgoing long wave radiation balance approximately. For the annual averages, net flux of radiation, evaporation(latent heat) loss are dominant in the Gumi reservoir. The evaporation losses are dominant from spring to early winter. This means that the Gumi reservoir rolls like a lake of thermal medium or deep depth.