• Title/Summary/Keyword: radiation hardening

Search Result 51, Processing Time 0.027 seconds

A design of radiation hardened common signal processing module for sensors in NPP (내방사선 원전센서 공통 신호처리 모듈 설계)

  • Lee, Nam-ho;Hwang, Young-gwan;Kim, Jong-yeol;Lee, Seung-min
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.19 no.6
    • /
    • pp.1405-1410
    • /
    • 2015
  • In this study we designed the radiation-hardened sensor signal processing modules that can be commonly used for a variety of sensors during normal operation and even in high-radiation environments caused by an accident. First development module was designed to receive the change of the R and C value from the sensors and to process the signal as a PWM modulation scheme. This module was assessed to have ± 10% error to the Full-Scale in the radiation test in the range of 12 kGy TID. The main cause of the error was analyzed as the annealing of the common circuit in the switching element and the consequent increase in the duty ratio of the pulse width modulation circuit according to the radiation dose increasement. The redesigned module for higher radiation resistivity with Stub transistor circuit was found to have less than 5% error to the Full-scale from the radiation test results for 20.7 kGy TID range.

Rubber Material Development and Performance Evaluation of Diaphragm Seal for Steam Generator Nozzle Dam

  • Woo, Chang-Su;Song, Chi-Sung;Lee, Han-Chil;Kwon, Jin-Wook
    • Elastomers and Composites
    • /
    • v.55 no.3
    • /
    • pp.222-228
    • /
    • 2020
  • Rubber materials, used in nuclear power plants, need high heat-oxidation resistance to curing or cracking under a heat aging environment. This is because they are applied to environments with high temperature, high humidity, and radiation exposure. Nuclear radiation causes additional hardening or degradation, therefore, rubber materials need radiation resistance that satisfies the general and any accidental conditions produced in the power plant. Therefore, in this study, we developed a rubber material with excellent heat and radiation resistance for the diaphragm seal of a nuclear steam generator nozzle dam. The rubber material greatly improved the reliability of the steam generator nozzle dam. In addition, 30 inch and 42 inch diaphragm seals were manufactured using the developed rubber material. A nozzle dam was installed in a nuclear power plant and tested under the same conditions as a steam generator to evaluate safety and reliability. In the future, the performance and safety of diaphragm seals developed through field tests of nuclear power plants will be evaluated and applied to currently operating and new nuclear power plants.

Analysis of Beam Hardening of Modulation Layers for Dual Energy Cone-beam CT (에너지 변조 필터로 구현한 이중 에너지 콘빔 CT의 에너지 스펙트럼 평가 연구)

  • Ahn, Sohyun;Cho, Sam Ju;Keum, Ki Chang;Choi, Sang Gyu;Lee, Rena
    • Progress in Medical Physics
    • /
    • v.27 no.1
    • /
    • pp.8-13
    • /
    • 2016
  • Dual energy cone-beam CT can distinguish two materials with different atomic compositions. The principle of dual energy cone-beam CT based on modulation layer is that higher energy spectrum can be acquired at blocked x-ray window. To evaluate the possibility of modulation layer based dual energy cone-beam CT, we analyzed x-ray spectrum for various thicknesses of modulation layers by Monte Carlo simulation. To compare with the results of simulation, the experiment was performed on prototype cone-beam CT for 50~100 kVp with CdTe XR-100T detector. As the result of comparing, the mean energy of energy spectrum for 80 kVp are well matched with that of simulation. The mean energy of energy spectrum for 80 and 120 kVp were increased as 1.67 and 1.52 times by 2.0 mm modulation layer, respectively. We realized that the virtual dual energy x-ray source can be generated by modulation layer.

The Study of Decrease Artifact when Scanning Head and Neck PET/CT(Decrease Radiation Dose of Patient) (두경부 PET/CT검사 시 인공음영 감소에 관한 연구 (환자 피폭선량 경감))

  • Kim, Ki-Jin;Kim, Gha-Jung;Yoo, Se-Jong;Kim, Jeong-Ho
    • Journal of the Korea Safety Management & Science
    • /
    • v.18 no.1
    • /
    • pp.153-158
    • /
    • 2016
  • Beam hardening artifact can be caused by metal material when performing PET exam. Therefore, we studied a solution decreasing artifact caused by metallic dental implant. The higher voltage, the lesser artifact in CT exam. But Higher voltage dosen't affect PET exam. The thicker silicon the lesser artifact in CT and PET exam. Both methods make less artifact in CT and PET exam. But considering safety of patient, the way of using silicon is better.

Properties of Coating Film Containing Silicone acrylate (실리콘 아크릴레이트를 함유하고 있는 코팅필름의 물성)

  • Lee, Bong-Woo;Bang, Moon-Soo;Hong, Jin-Who;Kim, Dae-Jun;Kim, Hyun-Joong
    • Journal of Adhesion and Interface
    • /
    • v.3 no.4
    • /
    • pp.10-18
    • /
    • 2002
  • Modern plastics are of great importance in many practical applications and their performance can be enhanced by surface modification to improve their hardness, wear and chemical resistance. The object of this study is invention of functional hardening coating materials which are applied to plastic, such as polycarbonate, polymethylmethacylate and acrylonitrilebutadienestyrene. In order to invention of hardening coating materials, we synthesized new silicone acrylate oligomer and prepared coating films containing silicone acrylate oligomer (SAOE) on PC substrate. The curing of coatings is performed by UV-radiation. As results of experiments, The properties of coating films which are contained SAOE is greatly improved in comparison with coating films non-contained SAOE. Especially, when 1 wt% SAOE was introduced into the coating formulation, the UV hardening coatings obtained showed the best surface hardness and gloss.

  • PDF

Surface morphology and deuterium retention in W and W-HfC alloy exposed to high flux D plasma irradiation

  • Yongkui Wang;Xiaochen Huang;Jiafeng Zhou;Jun Fang;Yan Gao;Jinlong Ge;Shu Miao;Zhuoming Xie
    • Nuclear Engineering and Technology
    • /
    • v.55 no.2
    • /
    • pp.575-579
    • /
    • 2023
  • In this work, pure W and W-0.5wt%HfC alloy (WHC05) were fabricated by sintering and hot-rolling following the same processing route. After exposing to a high flux deuterium plasma irradiation with the D+ flux to three fluences of 6.00 × 1024, 2.70 × 1025 and 7.02 × 1025 D/m2, the evolution of surface morphology, deuterium retention and hardening behaviors in pure W and WHC05 has been studied. The SEM results show the formation of D blisters on the irradiated area, and with the increase of D implantation, the size of these blisters increases from 200 ~ 500 nm (2.70 × 1025 D/m2) to 1 ~ 2 ㎛ (7.02 × 1025 D/m2) in WHC05 and from 1 ~ 2 ㎛ (2.70 × 1025 D/m2) to > 3 ㎛ (7.02 × 1025 D/m2) in pure W, respectively. A higher D retention and obvious hardening are observed in pure W than that of the WHC05 alloy, indicating an improve radiation resistance in WHC05 compared to pure W.

Heavy-Ion Radiation Characteristics of DDR2 Synchronous Dynamic Random Access Memory Fabricated in 56 nm Technology

  • Ryu, Kwang-Sun;Park, Mi-Young;Chae, Jang-Soo;Lee, In;Uchihori, Yukio;Kitamura, Hisashi;Takashima, Takeshi
    • Journal of Astronomy and Space Sciences
    • /
    • v.29 no.3
    • /
    • pp.315-320
    • /
    • 2012
  • We developed a mass-memory chip by staking 1 Gbit double data rate 2 (DDR2) synchronous dynamic random access memory (SDRAM) memory core up to 4 Gbit storage for future satellite missions which require large storage for data collected during the mission execution. To investigate the resistance of the chip to the space radiation environment, we have performed heavy-ion-driven single event experiments using Heavy Ion Medical Accelerator in Chiba medium energy beam line. The radiation characteristics are presented for the DDR2 SDRAM (K4T1G164QE) fabricated in 56 nm technology. The statistical analyses and comparisons of the characteristics of chips fabricated with previous technologies are presented. The cross-section values for various single event categories were derived up to ~80 $MeVcm^2/mg$. Our comparison of the DDR2 SDRAM, which was fabricated in 56 nm technology node, with previous technologies, implies that the increased degree of integration causes the memory chip to become vulnerable to single-event functional interrupt, but resistant to single-event latch-up.

Effect of black sand as a partial replacement for fine aggregate on properties as a novel radiation shielding of high-performance heavyweight concrete

  • Ashraf M. Heniegal;Mohamed Amin;S.H. Nagib;Hassan Youssef;Ibrahim Saad Agwa
    • Structural Engineering and Mechanics
    • /
    • v.87 no.5
    • /
    • pp.499-516
    • /
    • 2023
  • To defend against harmful gamma radiation, new types of materials for use in the construction of heavyweight concrete (HWC) are still needed to be developed. This research introduces new materials to be employed as a partial replacement for fine aggregate (FA) to manufacture high-performance heavyweight concrete (HPHWC). These materials include hematite, black sand, ilmenite, and magnetite, with substitution ratios of 50% and 100% of FA. In this research, the hardening and fresh characteristics of HPHWC were obtained. Concrete samples' Gamma-ray linear attenuation coefficient was evaluated utilizing a gamma source of Co-60 through the thicknesses of 2.5, 5, 7.5, 10, 12.5, and 15 cm. High temperatures were studied for HPHWC samples, which were exposed to up to 700℃ for two hours. Energy-dispersive x-rays and a scanning electron microscope carried out microstructure analyses. Magnetite as an FA attained the lowest compressive strength of 87.1 MPa, but the best radiation protection characteristics and the highest density of 3100 kg/m3 were achieved. After 28 days, the attenuation efficiency of concrete mixtures was increased by 6.5% when fine sand was replaced with black sand at a ratio of 50%. HPHWC, which contains hematite, black sand, ilmenite, and magnetite, is designed to reduce environmental and health dangers and be used in medicinal, military, and civil applications.

Effects of heat and gamma radiation on the degradation behaviour of fluoroelastomer in a simulated severe accident environment

  • Inyoung Song ;Taehyun Lee ;Kyungha Ryu ;Yong Jin Kim ;Myung Sung Kim ;Jong Won Park;Ji Hyun Kim
    • Nuclear Engineering and Technology
    • /
    • v.54 no.12
    • /
    • pp.4514-4521
    • /
    • 2022
  • In this study, the effects of heat and radiation on the degradation behaviour of fluoroelastomer under simulated normal operation and a severe accident environment were investigated using sequential testing of gamma irradiation and thermal degradation. Tensile properties and Shore A hardness were measured, and thermogravimetric analysis was used to evaluate the degradation behaviour of fluoroelastomer. Fourier transform infrared spectroscopy and X-ray photoelectron spectroscopy were used to characterize the structural changes of the fluoroelastomer. Heat and radiation generated in nuclear power plant break and deform the chemical bonds, and fluoroelastomer exposed to these environments have decreased C-H and functional groups that contain oxygen and double bonds such as C-O, C=O and C=C were generated. These functional groups were formed by auto oxidation by reacting free radicals generated from the cleaved bond with oxygen in the atmosphere. In this auto oxidation reaction, crosslinks were generated where bonded to each other, and the mobility of molecules was decreased, and as a result, the fluoroelastomer was hardened. This hardening behaviour occurred more significantly in the severe accident environment than in the normal operation condition, and it was found that thermal stability decreased with the generation of unstable structures by crosslinking.

Dosimetric Characteristics of Dynamic Wedge Technique (Dynamic Wedge의 조직내 방사선량 분포의 특성)

  • Oh Young Taek;Keum Ki Chang;Chu Seong Sil;Kim Gwi Eon
    • Radiation Oncology Journal
    • /
    • v.14 no.4
    • /
    • pp.323-332
    • /
    • 1996
  • Purpose : The wedge filter is the most commonly used beam modifying device during radiation therapy Recently dynamic wedge technique is available through the computer controlled asymmetric collimator, independent jaw. But dosimetric characteristics of dynamic wedge technique is not well known. Therefore we evaluate dosimetric characteristics of dynamic wedge compared to conventional fixed wedge. Materials and Methods : We evaluated dosimetric characteristics of dynamic wedge and fixed wedge by ion chamber, film dosimetry and TLD in phantoms such as water, polystyrene and average breast phantom. Six MV x-ray was used in $15{\times}15cm$ field with 15,30 and 45 degree wedge of dynamic/liked wedge system, Dosimeric characteristics are interpreted by Wellhofer Dosimetrie system WP700/WP700i and contralateral breast dose (CBD) with tangential technique was confirmed by TLD. Results : 1) Percent depth dose through the dynamic wedge technique in tissue equivalent phantom was similar to open field irradiation and there was no beam hardening effect compared to fixed wedge technique. 2) Isodose line composing wedge angle of dynamic wedge is more straight than hard wedge. And dynamic wedge technique was able to make any wedge angle on any depth and field size. 3) The contralateral breast dose in primary breast irradiation was reduced by dynamic wedge technique compared to fixed wedge. When the dynamic wedge technique was applied, the scatter dose was similar to that of open field irradiation. Conclusion : The dynamic wedge technique was superior to fixed wedge technique in dosimetric characteristics and may be more useful in the future.

  • PDF