• Title/Summary/Keyword: radiation concentration

Search Result 1,018, Processing Time 0.028 seconds

Disinfection and Reactivation of Microorganisms after UV Irradiation for Agricultural Water Reuse of Biofilter Effluent

  • Jung, Kwang-Wook;Yoon, Chun-G.;Hwang, Ha-Sun;Ham, Jong-Hwa
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.45 no.7
    • /
    • pp.94-106
    • /
    • 2003
  • A pilot study was performed to examine the feasibility of UV disinfection system and the reactivation of indicator microorganisms (TC, FC, E. coli) after UV irradiation for agricultural reuse of reclaimed water. Photoreactivation and dark repair enable UV-inactivated microorganisms to recover and may reduce the efficacy of UV inactivation, which might be drawbacks of the UV disinfection method. The effluent of biofilter for 16-unit apartment house was used as input to the UV disinfection system, and average SS and BOD concentration were 3.8 and 5.7 mg/L, respectively, and the mean level of total coliform was in the range of $1.0\times10^4$ MPN/100mL. UV disinfection was found to be effective and it reduced mean concentration of indicator microorganisms (total coliform, fecal coliform, and E. coli) to less than 100 MPN/100mL within 60s exposure using 17, 25, and 40W lamps. Two UV doses of 6 and 16 mW$\cdot$s/$\textrm{km}^2$ were applied and microorganisms reactivation was monitored under the dark, photoreactivating light, and solar irradiation. Microorganisms reactivation was observed in the UV dose of 6 mW$\cdot$s/$\textrm{km}^2$, and numbers increased up to 5% at the photoreactivating light and 1% at the dark. However, microorganisms were inactivated rather than reactivated at the solar radiation and numbers decreased to non-detectible level about below 2 MPN/100mL in 4 hours. In the case of 16 mW$\cdot$s/$\textrm{km}^2$, microorganism reactivation was not observed indicating that UV dose might affect the reactivation process such as photoreactivation and dark repair. Therefore, concerns associated with microorganism reactivation could be controlled by sufficient UV dose application. Agricultural reuse of reclaimed water might be even less concerned due to exposure to the solar irradiation that could further inactivate microorganisms. The pilot study result is encouraging, however, sanitary concern in water reuse is so critical that more comprehensive investigation is recommended.

Analysis of Radioactive Characterization in the Medical Linear Accelerator Shielding Wall Using Monte Carlo Method (몬테칼로법을 이용한 의료용 선형가속기 차폐벽의 방사화 특성 분석)

  • Lee, Dong-Yeon;Park, Eun-Tae
    • The Journal of the Korea Contents Association
    • /
    • v.16 no.10
    • /
    • pp.758-765
    • /
    • 2016
  • This study analyzed for the radioactive shielding wall, which shields the medical linear accelerator. This allows to evaluate the level of waste with respect to the shield wall, which accounts for more than half of the cost of dismantling later linac facility. In addition, by analyzing the waste processing method according we discuss the way to obtain the benefits in terms of dismantling cost. Results of the simulate, the amount sufficient to screen the amount of neutron radiation occurring in the shielding wall linac was measured. And neutron activation analysis results were analyzed nuclides more than about 20. This analysis was in excess of that, $^{24}Na$, $^{45}Ca$, $^{59}Fe$ nucleus paper deregulation concentration. The value is reduced is greater the deeper the depth of the shielding wall concentration. Based on this, three specific areas (E, F, G) was estimated to be impossible to landfill or recycling. The rest area was estimated to be buried or recycled if possible more than a predetermined depth.

Sensing Technology for Rapid Detection of Phosphorus in Water: A Review

  • Islam, Sumaiya;Reza, Md Nasim;Jeong, Jin-Tae;Lee, Kyeong-Hwan
    • Journal of Biosystems Engineering
    • /
    • v.41 no.2
    • /
    • pp.138-144
    • /
    • 2016
  • Purpose: Phosphorus is an essential element for water quality control. Excessive amounts of phosphorus causes algal bloom in water, which leads to eutrophication and a decline in water quality. It is necessary to maintain the optimum amount of phosphorus present. During the last decades, various studies have been conducted to determine phosphorus content in water. In this study, we present a comprehensive overview of colorimetric, electrochemical, fluorescence, microfluidic, and remote sensing technologies for the measurement of phosphorus in water, along with their working principles and limitations. Results: The colorimetric techniques determine the concentration of phosphorus through the use of color-generating reagents. This is specific to a single chemical species and inexpensive to use. The electrochemical techniques operate by using a reaction of the analyte of interest to generate an electrical signal that is proportional to the sample analyte concentration. They show a good linear output, good repeatability, and a high detection capacity. The fluorescence technique is a kind of spectroscopic analysis method. The particles in the sample are excited by irradiation at a specific wavelength, emitting radiation of a different wavelength. It is possible to use this for quantitative and qualitative analysis of the target analyte. The microfluidic techniques incorporate several features to control chemical reactions in a micro device of low sample volume and reagent consumption. They are cheap and rapid methods for the detection of phosphorus in water. The remote sensing technique analyzes the sample for the target analyte using an optical technique, but without direct contact. It can cover a wider area than the other techniques mentioned in this review. Conclusion: It is concluded that the sensing technologies reviewed in this study are promising for rapid detection of phosphorus in water. The measurement range and sensitivity of the sensors have been greatly improved recently.

Characteristics of Heat Flux in a Compartment Fire - Reduced Scale Test (구획공간 화재의 열유속 특성 - 축소 실험)

  • Kim, Sung-Chan;Ko, Gwon-Hyun
    • Fire Science and Engineering
    • /
    • v.25 no.5
    • /
    • pp.128-133
    • /
    • 2011
  • The present study performs a series of 40 % reduced scale of ISO-9705 fire test to investigate the characteristics of heat flux on the floor level in terms of fire characteristics and location in the compartment. The heat flux was measured with Schmidt-Boelter type heat flux gauge at two locations on the floor level of inside and doorway side of the compartment. Different types of fuel - methane, heptane, toluene, ethanol, polystyrene - were burned in this test series. The measured heat flux inside of the compartment was relatively higher than that of front side as the heat release rate of fire and upper layer temperature increased. The difference of measured heat flux at inside and doorway side increased for high sooty fire. The present study shows that the heat flux distribution at lower layer greatly depend on the thermal radiation from fire and upper layer, not only the upper layer temperature but also various fire characteristics such as composition of combustion gases, soot concentration, ventilation condition and so on.

Pbotocatalysis decomposition of TCE in water phase with recirculation photoreactor (Recirculation 광촉매 화학 반응기를 이용한 액상 TCE 분해)

  • 이태규;김동형;조덕기;조서현;오정무
    • Proceedings of the Korea Society for Energy Engineering kosee Conference
    • /
    • 1993.05a
    • /
    • pp.33-41
    • /
    • 1993
  • The objectives of this experiment performed were to determine the potential using of solar radiation to destroy organic contaminants in water by photolysis and to develop the process and improve its performance. We used lab, scale of recirculation photoreactor with 30, 50, 80ppm initial concentration of TCE and Ti $O_2$ anatase, respectively. Adsorption constant, reaction constant were obtained and compared using the Langmuir-Hinshelwood kinetics equation. Ti $O_2$ anatase demonstrated the highest conversion ratio co TCE among Ti $O_2$ anatase, ZnO and F $e_2$ $O_3$ in this experiment. It was shown that in case of two component system, TCE+ phenol, as the concentration of phenol increased in the feed solution, TCE decomposition rate decreased.

  • PDF

Effect of Hydrogen Peroxide on UV Treatment of Color in Secondary Effluent for Reclamation (물 재이용을 위한 하수처리장 방류수 색도의 자외선처리에 미치는 과산화수소의 영향)

  • Park, Ki-Young;Maeng, Sung-Kyu;Kim, Ki-Pal;Lee, Seock-Heon;Kweon, Ji-Hyang;Ahn, Kyu-Hong
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.18 no.3
    • /
    • pp.377-384
    • /
    • 2004
  • In the present study, a feasibility of an advanced oxidation process using UV/Hydrogen peroxide($H_2O_2$) system equipped with a medium pressure lamp for secondary effluent reclamation was investigated. Initial concentration of $H_2O_2$ and pH were changed to determine the optimum operation condition for the system. The removal efficiency of color was than 80% with 14.3mg/L of initial $H_2O_2$ and 5 minute of contact time in the UV/$H_2O_2$ system. The color removal was analyzed using first-order reaction equation. The dependence of rate constant (k) on initial $H_2O_2$ represented the rational relationship with maximum value. Residual $H_2O_2$ caused increase of effluent COD, since analyzing agent, dichromate, reacted with $H_2O_2$ in the sample. Therefore, excess initial concentration of $H_2O_2$ would significantly affect effluent COD measurement. At pH variation experiment, both residual $H_2O_2$ and color showed peak in the neutral pH range with the same pattern. Effect of $H_2O_2$ dose also enhanced color removal but raised residual $H_2O_2$ problem in the continuous operation UV system. In conclusion, these results indicated that medium pressure UV/$H_2O_2$ system could be used to control color in the secondary effluent for reclamation and reuse.

Effect of Nutrients on the Production of Extracellular Enzymes for Decolorization of Reactive Blue 19 and Reactive Black 5

  • Lee Yu-Ri;Park Chul-Hwan;Lee Byung-Hwan;Han Eun-Jung;Kim Tak-Hyun;Lee Jin-Won;Kim Sang-Yong
    • Journal of Microbiology and Biotechnology
    • /
    • v.16 no.2
    • /
    • pp.226-231
    • /
    • 2006
  • Several white-rot fungi are able to produce extracellular lignin-degrading enzymes such as manganese peroxidase (MnP), lignin peroxidase (LiP), and laccase. In order to enhance the production of laccase and MnP using Trametes versicolor KCTC 16781 in suspension culture, the effects of major medium ingredients, such as carbon and nitrogen sources, on the production of the enzymes were investigated. The decolorization mechanism in terms of biodegradation and biosorption was also investigated. Among the carbon sources used, glucose showed the highest potential for the production of laccase and MnP. Ammonium tartrate was a good nitrogen source for the enzyme production. No significant difference in the laccase production was observed, when glucose concentration was varied between 5 g/l and 30 g/l. As the concentration of nitrogen source increased, a lower MnP activity was observed. The optimal C/N ratio was 25 for the production of laccase and MnP. When the concentrations of glucose and ammonium tartrate were simultaneously increased, the laccase and MnP activities increased dramatically. The maximum laccase and MnP activities were 33.7 U/ml at 72 h and 475 U/ml at 96 h, respectively, in the optimal condition. In this condition, over 90% decolorization efficiency was observed.

The Variation Characteristics of Indoor Radon Concentration from Buildings with Different Environment, Seoul (서울지역 건축물의 환경적 특성에 따른 실내 라돈농도 변화)

  • Jeon, Jae-Sik;Lee, Ji-Young;Eom, Seok-Won;Chae, Young-Zoo
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.27 no.6
    • /
    • pp.692-702
    • /
    • 2011
  • For more effective indoor radon reduction policy and technique, we researched radon data analysis for some buildings in Seoul. Those buildings were categorized as dwelling, underground and office space and the variations of radon concentration and its sources were evaluated. The variations of radon concentrations of indoor space of buildings for a day were patterned specifically by dwelling habits and different environment. As for the new built apartments which were not yet moved in, their indoor radon concentrations were showed more than 3 times after applying interior assembly, and were 5 times higher than ones of rather old residences. As for the subway stations, the radon concentrations during off-run times were about 15% higher than run-times. 10% of radon seemed to be reduced by installation of platform screen doors. As for office space, radon concentrations during working hours were about 2.5 times higher than non-working hours. Plaster board are expected as a main source of radon for them. By radon measurement method for long-term, its data can be over estimated because it covers non-active time in office or public space. Therefore combination of short and long-term measurement method is required for effective and economic reduction. Furthermore importance of ventilation is requested as public information service for all dwelling space. And also standardization for radium content or radiation of radon is necessary.

Influencing Factors for Short-term Variations of Carbon Dioxide Concentration at the Gosan Site in Jeju, Korea (제주도 고산지역 CO2 농도의 단기 변동에 영향을 미치는 요인 분석)

  • Kim, Seung-Yeon;Lee, Sang-Deok;Kim, Deok-Rae;Lee, Jae-Bum;Song, Chang-Keun;Choi, Kwang-Ho;Han, Jin-Seok
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.30 no.5
    • /
    • pp.423-433
    • /
    • 2014
  • This study examined the short-term variability of $CO_2$ concentrations measured at the Gosan site ($33^{\circ}17^{\prime}N$, $126^{\circ}10^{\prime}E$) in Jeju, Korea for the last 9 years from 2002 to 2010. The weekly distribution shows higher $CO_2$ concentrations during weekends than weekdays which implies the impact of local emissions because Jeju Island is one of the top tourist attraction in Korea. In diurnal variation, $CO_2$ concentration reached the maximum at 6 am and the minimum at 1 pm. The high $CO_2$ concentrations were mostly associated with lower wind speed (below 4 m/s) and easterlies, which was typical of summer night. In other seasons, however, the high concentrations were encountered under strong westerlies (8~16 m/s), which implies the influence of Chinese outflows. $CO_2$ concentrations were found to be highly correlated with meteorological parameters including wind speed, temperature, humidity, and solar radiation except for winter.

A study on the Combustion Characteristics of Wall Paper (내장벽지의 연소특성에 관한 연구)

  • Oh, Kyu-Hyung;Choi, Yeon-Yi;Lee, Sung-Eun
    • Fire Science and Engineering
    • /
    • v.21 no.1 s.65
    • /
    • pp.90-97
    • /
    • 2007
  • Combustion characteristics and toxicity of combustion gas of wallpaper samples were analyzed to evaluate the fire risk of wallpaper furnished in living space. In this study ash residue ratio was measured with high temperature electric furnace, and thermal analysis was carried out with TGA. Combustion time and smoke concentration were measured with cone heater and combustion gas analyzer. Smoke density of samples was measured using smoke chamber of ASTM E 662. The experimental results were showed as followings. Pyrolysis of silk wallpaper started at lower temperature compared to the other samples. It means that the silk wallpaper can be ignited at low heat flux and will have more fire risk than the others. Ignition time by radiation heat flux of silk wallpaper is shorter compared to the other samples, so evacuation time must be reduced. In the case of vinyl coated silk wall paper, carbon mono oxide concentration is the highest and the toxicity and damage effect to consciousness was stronger compared to the other samples. Smoke density of silk wall paper and fire retardant mixed coated silk wall paper were very high due to vinyl coating.