• Title/Summary/Keyword: radial movement

Search Result 87, Processing Time 0.039 seconds

Analysis of fluctuations in ex-core neutron detector signal in Krško NPP during an earthquake

  • Tanja Goricanec;Andrej Kavcic;Marjan Kromar;Luka Snoj
    • Nuclear Engineering and Technology
    • /
    • v.56 no.2
    • /
    • pp.575-600
    • /
    • 2024
  • During an earthquake on December 29th 2020, the Krško NPP automatically shutdown due to the trigger of the negative neutron flux rate signal on the power range nuclear instrumentation. From the time course of the detector signal, it can be concluded that the fluctuation in the detector signal may have been caused by the mechanical movement of the ex-core neutron detectors or the pressure vessel components rather than the actual change in reactor power. The objective of the analysis was to evaluate the sensitivity of the neutron flux at the ex-core detector position, if the detector is moved in the radial or axial direction. In addition, the effect of the core barrel movement and core inside the baffle movement in the radial direction were analysed. The analysis is complemented by the calculation of the thermal and total neutron flux gradient in radial, axial and azimuthal directions. The Monte Carlo particle transport code MCNP was used to study the changes in the response of the ex-core detector for the above-mentioned scenarios. Power and intermediate-range detectors were analysed separately, because they are designed differently, positioned at different locations, and have different response characteristics. It was found that the movement of the power range ex-core detector has a negligible effect on the value of the thermal neutron flux in the active part of the detector. However, the radial movement of the intermediate-range detector by 5 cm results in 7%-8% change in the thermal neutron flux in the active part of the intermediate-range detector. The analysis continued with an evaluation of the effects of moving the entire core barrel on the ex-core detector response. It was estimated that the 2 mm core barrel radial oscillation results in ~4% deviation in the power and intermediate-range detector signal. The movement of the reactor core inside baffle can contribute ~6% deviation in the ex-core neutron detector signal. The analysis showed that the mechanical movement of ex-core neutron detectors cannot explain the fluctuations in the ex-core detector signal. However, combined core barrel and reactor core inside baffle oscillations could be a probable reason for the observed fluctuations in the ex-core detector signal during an earthquake.

Study on Movement of Wood (목재(木材)의 치수변동(変動)에 관(關)한 연구(硏究))

  • Jung, Hee-Suk;Lee, Phil-Woo;Lee, Nam-Ho
    • Journal of the Korean Wood Science and Technology
    • /
    • v.14 no.2
    • /
    • pp.36-42
    • /
    • 1986
  • Both the control and heated specimen of oak, hornbean, alder, poplar, red pine and pitch pine among domestic commercial species and taun imported were used for radial and tangential shrinkage and movement that occurred on changing the relative humidity of the atmosphere from 90 percent to 60 percent at $25^{\circ}C$. The results of this study were as follows. 1. The radial and tangential shrinkage of the control and heated hornbean and oak wood, except alder, of high specific gravity showed greater than species with low specific gravity. The ratio of tangential to radial shrinkage was 1.46 for taun to 2.70 for alder. Green volume specific gravity of the heated and soaked specimen of all species except poplar decreased 1.5 to 3.1 percent. Shrinkage of the heated specimen increased more than that of the control specimen, and antishrink efficiency of all timbers except alder had negative value. Shrinkage from green to air dry of treated specimens increased more than case of total shrinkage, and radial shrinkage of those specimen increased greater than tangential shrinkage. 3. The movement of the heating specimen for 120 hours decreased than those of the control and the heating specimen for 240 hours. The movement of heating oak, poplar, red pine and pitch pine (or 240 hours increased rather than those of the control specimen.

  • PDF

Effect of external compressive load during a continuous radio-frequency /vacuum process on movement behavior

  • Lee, Nam-Ho;Jin, Young-Moon
    • Journal of the Korea Furniture Society
    • /
    • v.17 no.1
    • /
    • pp.1-10
    • /
    • 2006
  • Movement behavior, shrinkage and equilibrium moisture content (EMC), in this experiment reflected a change of hygroscopicity mainly affected by continuously compressive load during radio-frequency/vacuum (RF/V) drying and humidity changes during equilibrating. As a result of interaction of the compressive load and moisture content changing under the RF/V condition, the shrinkages in loading direction were significantly increased while those perpendicular to loading direction were decreased. The shrinkages were affected most in tangential, and least in longitudinal direction. The shrinkages showed higher values in continuous drying than in intermittent drying. In the direction of increased shrinkage, all the movements were also increased, for example, the tangential movement for the loaded-RS and the radial movement for loaded-TS; in the direction of decreased shrinkage, all the movements except the tangential movement for the loaded-TS were decreased such as the tangential and radial movements for the loaded-ES, and the radial movement for the loaded-RS, comparing with those of the load-free. EMCs of the loaded specimens were all higher than that of the load-free specimen, and the highest for the loaded-TS, the lowest for the loaded-ES. The transverse hygroscopicity of specimen was reduced for the loaded-ES, but increased for the loaded-TS.

  • PDF

Two Cases of Radial Nerve Palsy with Chuna Treatment on Cervical Vertebrae (경추 추나치료를 적용한 압박성 요골신경마비 환자 치험 2례)

  • Heo, Su-Young
    • The Journal of Churna Manual Medicine for Spine and Nerves
    • /
    • v.6 no.1
    • /
    • pp.89-96
    • /
    • 2011
  • Objective : The purpose of this study is to evaluate the korean medical treatment for compressive neuropathy of radial nerve, especially chuna treatment of cervical vertebrae. Methods : Two patients were treated with acupuncture and moxibustion, herbal medication, chuna treatment on cervical vertebrae. To evaluate the wrist drop and numbness of hand, Coding Result of arbitrary values and manual muscle test(MMT), visual analogue scale(VAS) were used. Results : After 2 weeks-treatment(in case 1) & 5 weeks-treatment(in case 2), the movement and power of wrist were restored to nearly normal range, also the numbness of hands was removed. All cases show the improvement in the movement of wrist and the numbness of hands. Conclusions : Korean medical treatment including cervical manual therapy as chuna treatment is remarkably effective for radial nerve palsy. But further studies are required to concretely prove the effectiveness of chuna treatment on central vertebrae for peripheral neuropathy.

  • PDF

Moisture Movement in Softwood and its Activation Energy (침엽수재(針葉樹材) 내부수분이동(內部水分移動)과 확산활성화(擴散活性化)에너지)

  • Kang, Ho-Yang
    • Journal of the Korean Wood Science and Technology
    • /
    • v.19 no.4
    • /
    • pp.27-33
    • /
    • 1991
  • Three kinds of specimens(radiata pine sapwood, radiata pine heartwood and whemlock heartwood) were dried at four temperature levels (30, 40, 50 and $60^{\circ}C$) in an emvironmental chamber. Unsteady-state diffusion coefficients were calculated from obtained drying fates by using infinite slab equation for first half of sorption and interval diffusion equation for second half of sorption. Activation energies for moisture diffusion in wood were calculated from the diffusion coefficients obtained at four temperatures. In most cases diffusion coefficients for radial movement were higher than those for tangential movement. Activation energy differences between sapwood and heartwood weren't significant for radial movement, but were significant for tangential movement. Most activation energies calculated from drying rates were lower than heat of water condensation(about 11,000cal/mole). Specially the avenge activation energy for sapwood tangential movement was only 5,000cal/mole.

  • PDF

A TMR Budget Design for 100kTPI Hard Disk Drives Using a Head Gimbal Assembly with Radial Motion Capability (100kTPI급 하드 디스크 드라이브 TMR 설계를 위한 SUSPENSION에 관한 연구)

  • Oh, Dong-Ho;Kang, Seong-Woo;Han, Yun-Sik;Kim, Young-Hoon;Koh, Jeong-Seok;Hwang, Tae-Yeon
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2002.11b
    • /
    • pp.140-145
    • /
    • 2002
  • In high-capacity disk drives with ever-growing track density, the allowable level of position error signal (PES) is becoming smaller and smaller. A substantial portion of the PES is caused by disk vibration. This can be reduced by using a head gimbal assemblies (HGAs) that do not confine the slider movement to the vertical direction to disks, but allow movement to the radial direction of disks with respect to disk vibration. Several types of HGAs are proposed for such radial motion of the slider. Experimental results show that the PES levels are reduced by the proposed HGA-design concepts.

  • PDF

A TMR Budget Design for 100kTPI Hard Disk Drives Using a Head Gimbal Assembly with Radial Motion Capability (100 kTPI급 HDD TMR 설계를 위한 Suspension에 관한 연구)

  • D. H. Oh;S. W. Kang;Y. S. Han;Kim, Y. H.;T. Y. Hwang
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2002.11a
    • /
    • pp.320.2-320
    • /
    • 2002
  • In high-capacity disk drives with ever-growing track density, the allowable level of position error signal (PES) is becoming smaller and smaller. A substantial portion of the PES is caused by disk vibration. This can be reduced by using a head gimbal assemblies (HGAs) that do not confine the slider movement to the vertical direction to disks, but allow movement to the radial direction of disks with respect to disk vibration. Several types of HGAs are proposed for such radial motion of the slider. (omitted)

  • PDF

Analysis of Radial Force Density as a Vibration Source in Brushless DC Motor Using 3D Equivalent Magnetic Circuit Network Method (3차원 등가자기회로망법을 이용한 Brushless DC 모터의 진동원으로서의 Radial Force Density 해석)

  • Chun, Y.D.;Hur, J.;Yoon, S.B.;Hong, J.P.;Hyun, D.S.
    • Proceedings of the KIEE Conference
    • /
    • 1997.07a
    • /
    • pp.171-173
    • /
    • 1997
  • This paper presents analysis of the radial force density in brushless DC motor of which distribution is not uniform in the axial direction. The analysis considering 3D shape of teeth and overhang is not only important but essential to calculate the radial force density that acts on the teeth of stator, because it is frequent source of vibration and changes at the end of teeth. For the analysis, a new 3D equivalent magnetic circuit network method taking into account movement of the rotor without remesh is proposed. The radial force density is calculated by Maxwell stress tensor and analyzed by discrete Fourier transform.

  • PDF

Three Cases of Radial Nerve Palsy with Bee Venom Therapy (봉약침요법(蜂藥鍼療法)을 이용한 요골신경마비(橈骨神經麻痺) 치험(治驗) 3례(例))

  • Kim, Il-Hwan;Wei, Tung-Shuen;Kim, Hyo-Soo
    • Journal of Pharmacopuncture
    • /
    • v.7 no.2
    • /
    • pp.75-81
    • /
    • 2004
  • Objective : The purpose of this study is to report the efficiency of Bee Venom Therapy by managering of radial nerve palsy patients. Method : Three patients were treatmented by Bee Venom therapy and acupucture therapy. And we took pictures of someone's wrist and checked the power of muscles by the improving phase. Results : Almost cases shows the improvement in the movement of wrist and the numbness of hand. By using acuputure and Bee Venom therapy, the symptoms of radial nerv palsy was more fastly recovered.

A New Measurement Method of a Radial Pulse Wave Using Multiple Hall Array Devices

  • Lee, Sang-Suk;An, Myoung-Chone;Ahn, Sung-Hoon
    • Journal of Magnetics
    • /
    • v.14 no.3
    • /
    • pp.132-136
    • /
    • 2009
  • This study investigated the radial pulse waveform obtained by a medical pulsimeter sensor. A pulse-sensing part array consisting of multiple Hall devices was located over a skin-contacting part with a hard magnetic material. The periodic movement of the magnetic material of the skin-contacting part affected the magnetic field in the pulse-sensing part array and was detected by multiple Hall devices. The analysis of a radial pulse waveform that is measured noninvasively by detecting the changes of the magnetic field can be used to develop a new diagnostic algorithm of oriental medical apparatus.