• Title/Summary/Keyword: radial distribution

Search Result 858, Processing Time 0.028 seconds

Prevalence of feline calicivirus and the distribution of serum neutralizing antibody against isolate strains in cats of Hangzhou, China

  • Zheng, Mengjie;Li, Zesheng;Fu, Xinyu;Lv, Qian;Yang, Yang;Shi, Fushan
    • Journal of Veterinary Science
    • /
    • v.22 no.5
    • /
    • pp.73.1-73.11
    • /
    • 2021
  • Background: Feline calicivirus (FCV) is a common pathogen of felids, and FCV vaccination is regularly practiced. The genetic variability and antigenic diversity of FCV hinder the effective control and prevention of infection by vaccination. Improved knowledge of the epidemiological characteristics of FCV should assist in the development of more effective vaccines. Objectives: This study aims to determine the prevalence of FCV in a population of cats with FCV-suspected clinical signs in Hangzhou and to demonstrate the antigenic and genetic relationships between vaccine status and representative isolated FCV strains. Methods: Cats (n = 516) from Hangzhou were investigated between 2018 and 2020. The association between risk factors and FCV infection was assessed. Phylogenetic analyses based on a capsid coding sequence were performed to identify the genetic relationships between strains. In vitro virus neutralization tests were used to assess antibody levels against isolated FCV strains in client-owned cats. Results: The FCV-positive rate of the examined cats was 43.0%. Risk factors significantly associated with FCV infection were vaccination status and oral symptoms. Phylogenetic analysis revealed a radial phylogeny with no evidence of temporal or countrywide clusters. There was a significant difference in the distribution of serum antibody titers between vaccinated and unvaccinated cats. Conclusions: This study revealed a high prevalence and genetic diversity of FCV in Hangzhou. The results indicate that the efficacy of FCV vaccination is unsatisfactory. More comprehensive and refined vaccination protocols are an urgent and unmet need.

Using three-dimensional theory of elasticity for vibration analysis of laminated sectorial plates

  • Liyuan Zhao;Man Wang;Rui Yang;Meng Zhao;Zenghao Song;N. Bohlooli
    • Steel and Composite Structures
    • /
    • v.48 no.1
    • /
    • pp.1-17
    • /
    • 2023
  • The main goal of this paper is to study vibration of damaged core laminated sectorial plates with Functionally graded (FG) face sheets based on three-dimensional theory of elasticity. The structures are made of a damaged isotropic core and two external face sheets. These skins are strengthened at the nanoscale level by randomly oriented Carbon nanotubes (CNTs) and are reinforced at the microscale stage by oriented straight fibers. These reinforcing phases are included in a polymer matrix and a three-phase approach based on the Eshelby-Mori-Tanaka scheme and on the Halpin-Tsai approach, which is developed to compute the overall mechanical properties of the composite material. Three complicated equations of motion for the sectorial plates under consideration are semi-analytically solved by using 2-D differential quadrature method. Using the 2-D differential quadrature method in the r- and z-directions, allows one to deal with sandwich annular sector plate with arbitrary thickness distribution of material properties and also to implement the effects of different boundary conditions of the structure efficiently and in an exact manner. The fast rate of convergence and accuracy of the method are investigated through the different solved examples. The sandwich annular sector plate is assumed to be simply supported in the radial edges while any arbitrary boundary conditions are applied to the other two circular edges including simply supported, clamped and free. Several parametric analyses are carried out to investigate the mechanical behavior of these multi-layered structures depending on the damage features, through-the-thickness distribution and boundary conditions.

Influence of Blending Method on the Generation of Wear Particulate Matters and Physical Properties in TBR Tire Tread Compounds

  • Sanghoon Song;Junhwan Jeong;Jin Uk Ha;Daedong Park;Gyeongchan Ryu;Donghyuk Kim;Kiwon Hwang;Sungwook Chung;Wonho Kim
    • Elastomers and Composites
    • /
    • v.58 no.4
    • /
    • pp.161-172
    • /
    • 2023
  • Because particulate matter has emerged as a major contributor to air pollution, the tire industry has conducted studies to reduce particulate matters from tires by improving tire performance. In this study, we compared the conventional blending method, in which rubber, filler, and additives are mixed simultaneously, to the Y-blending method, in which masterbatches are blended. We manufactured carbon black (CB)-filled natural rubber (NR)/butadiene rubber (BR) blend and silica-filled epoxidized NR/BR blend compounds to compare the effects of the two blending methods on the physical properties of the compounds and the amount of particulate matter generated. The Y-blending method provided uniform filler distribution in the heterogeneous rubber matrix, improved processability, and exhibited low rolling resistance. This method also improved physical properties owing to the excellent filler-rubber interaction. The results obtained from measuring the generation of particulate matter indicated that, the Y-blending method reduced PM2.5 particulate matter generation from the CB-filled and silica-filled compounds by 38% and 60%, and that of PM10 by 29% and 67%, respectively. This confirmed the excellence of the Y-blending method regarding the physical properties of truck bus radial tire tread compounds and reduced particulate matter generated.

Solar concentrator optimization against wind effect

  • Sayyed Hossein Mostafavi;Amir Torabi;Behzad Ghasemi
    • Wind and Structures
    • /
    • v.38 no.2
    • /
    • pp.109-118
    • /
    • 2024
  • A solar concentrator is a reflective surface in the shape of a parabola that collects solar rays in a focal area. This concentrator follows the path of the sun during the day with the help of a tracking system. One of the most important issues in the design and construction of these reflectors is the force exerted by the wind. This force can sometimes disrupt the stability of the concentrator and overturn the entire system. One of the ways to estimate the force is to use the numerical solution of the air flow in three dimensions around the dish. Ansys Fluent simulation software has been used for modeling several angles of attack between 0 and 180 with respect to the horizon. From the comparison of the velocity vector lines on the dish at angles of 90 to - 90 degrees, it was found that the flow lines are more concentrated inside the dish and there is a tendency for the flow to escape around in the radial direction, which indicates the presence of more pressure distribution inside the dish. It was observed that the pressure on the concave surface was higher than the convex one. Then, the effect of adding a hole with various diameter of 200, 300, 400, 500, and 600 mm on the dish was investigated. By increasing the diameter up to the optimized size of 400 mm, a decrease in the maximum pressure value in the pressure distribution was shown inside the dish. This pressure drop decreased the drag coefficient. The effect of the hole on the dish was also investigated for the 30-degree angled dish, and it was found that the results of the 90-degree case should be considered as the basis of the design.

Study on the Mobility of Cd Ion Using Extraction by Solutions in Stem Wood of Pinus densiflora L. (용매추출(溶媒抽出)에 의한 소나무(Pinus densiflora L.) 수간부(樹幹部)에서의 Cd 이동성(移動性)에 관(關한) 연구(硏究))

  • Shin, Kyungwon;Cho, Namhoon;Kim, Jeong-Gyu
    • Journal of Korean Society of Forest Science
    • /
    • v.89 no.1
    • /
    • pp.77-84
    • /
    • 2000
  • In order to understand the chemical binding forms of Cd in terms of its binding strength in wood, the radial distribution of it through dendroanalysis and its different chemical fractions in trunk wood of mature red pine(Pinus densiflora L.) trees grown in a relatively unpolluted area, in Kangwon-Province, were examined. Total Cd concentration in stem wood was determined by dry digestion and $H_2O$ and 0.01 M solutions of citric acid, malic acid, $CaCl_2$, $MgCl_2$, $Na_2EDTA$ were used as extracting solutions for Cd. Extracting efficiencies of applied solutions were expressed as % of Cd concentration extracted by $Na_2EDTA$ which extracted all Cd instead of Cd total concentration. Total concentration of Cd decreased from the innermost rings near pith towards the the outermost rings near cambium. Especially through the transition zone this tendency was observed clearly. $H_2O$ was the least effective extractant of Cd, then extracting efficiency increased in the order $MgCl_2$ < $CaCl_2$ $Na_2EDTA$ (extracted all Cd). According to the radial position, extracting efficiency of Cd was ranging from 7 to 30% by $H_2O$ and even from 60 to 95% by citric acid. The Cd extracting efficiencies of $H_2O$ and organic acids increased continuously from the stem center to outermost annual rings, whereas salts showed somewhat different tendency, suddenly decreasing near the outermost ring. The results are discussed with regard to the different chemical binding forms of Cd and the mobility of Cd in wood and comparable with ones in previous studies on Pinus sylvestris and Quercus patraea. According to the results, usefulness of radial distribution pattern of Cd in pine tree trunks for retrosective biomonitoring is questioned.

  • PDF

A Study on the dose distribution produced by $^{32}$ P source form in treatment for inhibiting restenosis of coronary artery (관상동맥 재협착 방지를 위한 치료에서 $^{32}$ P 핵종의 선원 형태에 따른 선량분포에 관한 연구)

  • 김경화;김영미;박경배
    • Progress in Medical Physics
    • /
    • v.10 no.1
    • /
    • pp.1-7
    • /
    • 1999
  • In this study, the dose distributions of a $^{32}$ p uniform cylindrical volume source and a surface source, a pure $\beta$emitter, were calculated in order to obtain information relevant to the utilization of a balloon catheter and a radioactive stent. The dose distributions of $^{32}$ p were calculated by means of the EGS4 code system. The sources are considered to be distributed uniformly in the volume and on the surface in the form of a cylinder with a radius of 1.5 mm and length of 20 mm. The energy of $\beta$particles emitted is chosen at random in the $\beta$ energy spectrum evaluated by the solution of the Dirac equation for the Coulomb potential. Liquid water is used to simulate the particle transport in the human body. The dose rates in a target at a 0.5mm radial distance from the surface of cylindrical volume and surface source are 12.133 cGy/s per GBq (0.449 cGy/s per mCi, uncertainty: 1.51%) and 24.732 cGy/s per GBq (0.915 cGy/s per mCi, uncertainty: 1.01%), respectively. The dose rates in the two sources decrease with distance in both radial and axial direction. On the basis of the above results, the determined initial activities were 29.69 mCi and 1.2278 $\mu$Ci for the balloon catheter and the radioactive stent using $^{32}$ P isotope, respectively. The total absorbed dose for optimal therapeutic regimen is considered to be 20 Gy and the treatment time in the case of the balloon catheter is less than 3 min. Absorbed doses in targets placed in a radial direction for the two sources were also calculated when it expressed initial activity in a 1 mCi/ml volume activity density for the cylindrical volume source and a 0.1 mCi/cm$^2$ area activity density for the surface source. The absorbed dose distribution around the $^{32}$ P cylindrical source with different size can be easily calculated using our results when the volume activity density and area activity density for the source are known.

  • PDF

A Study on the Mechanochemical Effects of Dickite (Dickite의 메카노케미칼 효과에 관한 연구)

  • Ryu, Ho-Jin
    • Korean Journal of Materials Research
    • /
    • v.7 no.2
    • /
    • pp.152-156
    • /
    • 1997
  • In this paper, I meritioned ,I study on thc rnechanochernic;~l effec ts of grountl iljckite To investigate the mechanochemical effects of ground tlickite 1,y planet,~r\- mill. a structul-ill i~nalvsis of dickite prepared with different grinding time has been made 11y X-ray diffraction and ilifierenti,~l tl~i.~-ni;~i analysis. 'l'he $SiO_{4}$ hecira was unchanged bl- milling and remained ;is the local ordering unit s t t - ~ c ~ u ~ - c ~ s in the ground dickitc samples I ) v analyzing the radial distribution function. On the other hand, with an increi~se of the grinding time a decrease of coordination number and atomic distance bet\vccn aluminum and oxygen hi1c.r l~een octurreil, and Li~~antitativcl\. coniirrned them This result corresponded to the local c,hange around aliimi~iuni I>V tliftercntii~l t1ii:rm;il ani~lysis. Therefore, the mechanochemical phenomina of ground tiickite werc3 h e to the local c~l~mge around aluminum \IT. the prolonged grinding.

  • PDF

A Study on the Structural Analysis of Amorphous Silicondioxide Prepared Sol-Gel Method with XRD (X-선 회절을 이용한 비정질 SiO$_2$ Gel 의 구조 해석에 관한 연구)

  • Yoon dai Hyun;Kim Ki Sun;Jung Hyun Chai
    • Journal of the Korean Chemical Society
    • /
    • v.34 no.5
    • /
    • pp.413-417
    • /
    • 1990
  • The structural variation process of amorphous SiO$_2$ gel upon heat-treatment conditions of 80, 250, 450 and 1000$^{\circ}C$ has been studied by using the radial distribution functions (RDF$_{obs}$) estimated from the X-ray diffraction intensities. The expected gel structure was determined by comparing the RDF$_{obs}$ with those for the other six standard samples selected appropriately. The structure of specimens prepared by sol-gel method is well consistent with that of fused SiO$_2$ (${\beta}$-cristobalite with cubic symmetry) except a slight difference in O-O band distance.

  • PDF

DEVELOPMENT OF EULERIAN-GRANULAR MODEL FOR NUMERICAL SIMULATION MODEL OF PARTICULATE FLOW (Eulerian-Granular method를 사용한 고체 입자 유동 모델 개발)

  • Lee, T.G.;Shin, S.W.
    • Journal of computational fluids engineering
    • /
    • v.20 no.2
    • /
    • pp.46-51
    • /
    • 2015
  • In this paper, we have developed numerical model for particulated flow through narrow slit using Eulerian-Granular method. Commercial software (FLUENT) was utilized as simulation tool and main focus was to identify the effect from various numerical options for modeling of solid particles as continuos phase in granular flow. Gidaspow model was chosen as basic model for solid viscosity and drag model. And lun-et-al model was used as solid pressure and radial distribution model, respectively. Several other model options in FLUENT were tested considering the cross related effect. Mass flow rate of the particulate through the slit was measured to compare. Due to the high volume density of the stacked particulates above the slit, effect from various numerical options were not significant. The numerical results from basic model were also compared with experimental results and showed very good agreement. The effects from the characteristics of particles such as diameter, angle of internal friction, and collision coefficient were also analyzed for future design of velocity resistance layer in solar thermal absorber. Angle of internal friction was found to be the dominat variable for the particle mass flow rate considerably. More defined 3D model along with energy equation for complete solar thermal absorber design is currently underway.

Intelligent Shape Analysis of the 3D Hippocampus Using Support Vector Machines (SVM을 이용한 3차원 해마의 지능적 형상 분석)

  • Kim, Jeong-Sik;Kim, Yong-Guk;Choi, Soo-Mi
    • 한국HCI학회:학술대회논문집
    • /
    • 2006.02a
    • /
    • pp.1387-1392
    • /
    • 2006
  • 본 논문에서는 SVM (Support Vector Machine)을 기반으로 하여 인체의 뇌 하부구조인 해마에 대한 지능적 형상분석 방법을 제공한다. 일반적으로 의료 영상으로부터 해마의 형상 분석을 하기 위해서는 충분한 임상 데이터를 필요로 한다. 하지만 현실적으로 많은 양의 표본들을 얻는 것이 쉽지 않기 때문에 전문가의 지식을 기반으로 한 작업이 수반되어야 한다. 결국 이러한 요소들이 분석 작업을 어렵게 한다. 의학 기술이 복잡해 지면서 최근의 형상 분석 연구는 점차 통계적 모델을 기반으로 진행되고 있다. 본 연구에서는 해마로부터 고해상도의 매개변수형 모델을 만들어 형상 표현으로 이용하고, 집단간 분류 작업에 SVM 알고리즘을 적용하는 지능적 분석 방법을 구현한다. 우선 메쉬 데이터로부터 물리변형모델 기반의 매개변수 모델을 구축하고, PDM (point distribution model) 방법을 적용하여 두 집단을 대표하는 평균 모델을 생성한다. 마지막으로 SVM 기반의 이진 분류기를 구축하여 집단간 분류 작업을 수행한다. 구현한 모델링 방법과 분류기의 성능을 평가하기 위하여 본 연구에서는 네 가지 커널 함수 (linear, radial basis function, polynomial, sigmoid)들을 적용한다. 본 논문에서 제시한 매개변수형 모델은 다양한 형태의 의료 데이터로부터 보편적인 3차원 모델을 생성하고, 또한 모델의 전역적, 국부적인 특징들을 복합적으로 표현할 수 있기 때문에 통계적 형상분석에 적합하다. 그리고 SVM 기반의 분류기는 적은 수의 학습 데이터로부터 정상인 해마 집단과 간질 환자 집단간의 정확한 분류를 가능하게 한다.

  • PDF