• Title/Summary/Keyword: radial distribution

Search Result 851, Processing Time 0.035 seconds

The Experimental Study on the Interaction of Dual Orifice Type Swirl Injectors (이중선회 분무간의 상호작용에 관한 실험적 연구)

  • Kim, H.J.;Park, B.S.;Kim, H.Y.;Chung, J.T.
    • 한국연소학회:학술대회논문집
    • /
    • 2001.06a
    • /
    • pp.119-126
    • /
    • 2001
  • The effects of injection pressure and the distance between injectors on the droplet distribution characteristics of liquid spray for dual orifice type swirl injectors were experimentally investigated. The SMD distributions, volume concentration and Rosin- Rammler variation N of liquid spray droplets for water and a fuel were measured by using the laser diffraction particle sizer. The results of present study show that SMD decreases and spray angle increases as the injection pressure increases. The interaction of sprays from two injectors gives more uniform SMD distribution in the radial direction. As the distance between two injectors increases, SMD that is measured in the interacting region increases. The effect of viscosity on the droplet distribution in the interacting region is greater than the that of surface tension of liquid.

  • PDF

UV ENERGY DISTRIBUTION OF AZ CASSIOPEIAE

  • Kang, Young-Woon
    • Journal of Astronomy and Space Sciences
    • /
    • v.11 no.1
    • /
    • pp.31-40
    • /
    • 1994
  • The IUE low dispersion spectra of AZ Cas have been analyzed for line identifications and energy distribution in ultraviolet region. Highly ionized atoms, SiIV and CIV are identified. We could infer a temperature range of the B star between 15,000K and 20,000K. The energy density distribution shows a hump between IUE short wavelength and long wavelength regions. Photometric and spectroscopic elements were revised based on the Florkowisk photeelectric observations and collected radial velocities. The temperature of both stars were reduced as 16,000K and 3,800K. The radii of both stars are $10 R_{\odot}\;and\;320R_{\odot}$. The eccentricity and longitude of periastron are 0.61 and $10.5^{\circ}$, respectively.

  • PDF

Optimal Routing for Distribution System Planning using New Adaptive GA (새로운 적응 유전 알고리즘을 이용한 배전계통계획의 최적경로탐색)

  • Kim, Min-Soo;Kim, Byung-Seop;Lee, Tae-Hyung;Shin, Joong-Rin
    • Proceedings of the KIEE Conference
    • /
    • 2000.07a
    • /
    • pp.137-141
    • /
    • 2000
  • This paper presents an application of a new Adaptive Genetic Algorithms(AGA) to solve the Optimal Routing problem(ORP) for distribution system planning. In general, since the ORP is modeled as a mixed integer problem with some various mathematical constraints, it is hard to solve the problem. In this paper, we proposed a new adaptive strategy in GA to overcome the premature convergence and improve the convergence efficiency. And for these purposes, we proposed a fitness function suited for the ORP. In the proposed AGA, we used specially designed adaptive probabilities for genetic operators to consider the characteristics of distribution systems that are operated under radial configuration. The proposed algorithm has been tested in sample networks and the results are presented.

  • PDF

Load Distribution, Contact and Fatigue Life Analysis of Pitch Bearing for Wind Turbine (풍력발전기용 피치베어링의 하중분배, 접촉 및 피로수명 해석)

  • Kim, Youngjin;Moon, Sukman;Cho, Yongjoo
    • Tribology and Lubricants
    • /
    • v.29 no.1
    • /
    • pp.33-38
    • /
    • 2013
  • This study is aimed to predict the fatigue life for pitch bearings under combined radial, thrust load and moment. In order to do this, a series of simulation such as bearing load distribution, initial surface stress, subsurface stress and fatigue analysis is needd. Fatigue life for pitch bearing can be predicted by using a bearing's material fatigue property.

Themally Loaded Characteristics of Diesel Engine Piston (디젤기계의 피스톤 열부하 특성에 관한 연구)

  • Han, Mun-Sik;Park, Tae-In
    • 한국기계연구소 소보
    • /
    • s.15
    • /
    • pp.91-103
    • /
    • 1985
  • In this paper, temperature distribution and thermal stress are investigated considering engine peak pressure and the time average temperature distribution in the piston under running conditions for the diesel engine. The induced stress are calculated by the Finite Element Method(FEM). The results obtained are summerized as follows. 1) The results calculated by the FEM present good agreement with other numerical solution in literature. 2) It is confirmed that maximum compressive stress are induced in the part of outside wall between the piston crown and the pin bush. 3) In the axial direction, the hoop stresses are changed its sigh at the portion of crown near the inner wall side 4)Large gradient of temperature is shown in the piston crown near the side wall in the axial direction, in the part between the piton crown and the pin bush in radical direction 5)in case of stress distribution of piston wall surface in the axial direction, the hoop stress is a little greater than axial stress, and the latter is greater than the radial stress

  • PDF

A Study on the Effective Coordination Scheme of Recloser for the Conventional Distribution System Interconnected Dispersed Generation (배전계통에 분산전원 연계시 기존 배전 계통측의 효과적인 리클로저 보호협조 연구)

  • Jung, Seung-Bock;Kim, Jae-Chul;Moon, Jong-Fil;Yun, Sang-Yun;Choi, Joon-Ho;Bae, Joo-Chun
    • Proceedings of the KIEE Conference
    • /
    • 2002.07a
    • /
    • pp.533-535
    • /
    • 2002
  • In Korea, power requirement has been increasing. But the large generation unit is hardly installed because of economic and environment problem. Therefore, the concern of dispersed generation system(DGS) is growing. The power distribution system is generally operated with radial type. The protection system is composed of one directive source. But power distribution system inserted DGS changes it to two directive source system. Therefore, the insertion of DGS has the problem of protection coordination. In this paper, we argue fault current affected by interconnected DGS. We analyze fault current flow affected by DGS placement. Then, we find protective coordination problem. Consequently, we study advance point for protection scheme of power system interconnected DGS.

  • PDF

Development of a Loss of Mains Detection Method for Distributed Resources (분산 전원의 고립 운전 검출 기법 개발)

  • Jang, S.I.;Kim, K.H.
    • Proceedings of the KIEE Conference
    • /
    • 2001.05a
    • /
    • pp.42-45
    • /
    • 2001
  • The islanding protection for distributed resources (DR) becomes an important and emerging issue in power system protection since the distributed generator installations are rapidly increasing and most of the installed systems are interconnected with distribution network. In order to avoid the negative impacts on distributed network resulting from islanding operations of DR, it is necessary to detect the loss of mains (LOM) effectively. This paper presents a new LOM detection method using the rate of change in total harmonic distortion (THD) of current. The proposed method effectively detects LOM of the DR unit operating in parallel with the distribution network. We also verified the efficiency of the proposed method using the radial distribution network of IEEE 34 bus model.

  • PDF

A Study on the Flow Characteristics of an Intermittent Fuel Spray (간헐적인 연료분무의 유동특성에 관한 연구)

  • Kim, Won-Tae;Gang, Sin-Jae
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.21 no.9
    • /
    • pp.1198-1206
    • /
    • 1997
  • The flow characteristics of an intermittent fuel injection into a stationary ambient air were investigated using gasoline. The measurements were made by two-channel, air cooling type Phase Doppler Anemometer(PDA) system (DANTEC, 750 MW). And a pintle type injector of MPI (Multi-point Port Injection) system was utilized as a fuel injector. The PDA receiver optic was set up in a 60.deg. C forward scatter arrangement to obtain the optimum scattering signal of fuel droplets. The data were obtained by synchronizing PDA system with the fuel injection period, and the axial and radial velocity and turbulent components of fuel droplets were mainly measured for the analysis of temporal and spatial distribution depending upon the fuel injection pressures.

UNCERTAINTIES IN THE STAR-COUNT ANALYSIS

  • Hong, Seung-Soo;Lee, See-Woo
    • Journal of The Korean Astronomical Society
    • /
    • v.21 no.2
    • /
    • pp.155-171
    • /
    • 1988
  • We have examined how sensitively the extinction value determined by the method of star-count depends on such factors as the plate limit, the size of counting reseau, the non-linearity in the number distribution of stars with magnitude, and the angular resolution demanded by the given problem. We let the Poisson distribution portray the statistical nature of the countings, and chose the region containing the globule Barnard 361 as an example field. Uncertainties due to various combinations of the factors are presented in graphic forms: (1) Dynamic range in the extinction measurements is evaluated as a function of reseau size for varying plate limits. (2) Statistical errors involved in the star-count are analized in terms of the signal-to-noise ratio, the plate limit and the reseau size. (3) Systematic error due to the non-linearity in the number distribution are thoroughly analized. (4) Finally, a methodology is presented for correcting the systematic error in the observed radial density gradient. These graphs are meant to be used in selecting proper size of the reseau and in estimating errors inherent to the star-count analysis.

  • PDF

A study on distribution system reconfiguration with constant power load using Genetic algorithms (유전알고리즘을 이용한 정전력부하를 갖는 배전계통 선로의 재구성에 관한 연구)

  • Mun, K.J.;Kim, H.S.;Hwang, G.H.;Lee, H.S.;Park, J.H.
    • Proceedings of the KIEE Conference
    • /
    • 1995.11a
    • /
    • pp.71-73
    • /
    • 1995
  • This paper presents an optimization technique using genetic algorithms(GA) for loss minimization in the distribution network reconfiguration. Determining switch position to be opened for loss minimization in the radial distribution system is a discrete optimization problem. GA is appropriate to solve the multivariable optimization problem and it uses population, not a solution. For this reason, GA is attractive to solve this problem. In this paper, we aimed at finding appropriate open sectionalizing switch position using GA, which can lead to minimum transmission losses.

  • PDF