• Title/Summary/Keyword: quench detection

Search Result 17, Processing Time 0.022 seconds

Numerical estimation on balance coefficients of central difference averaging method for quench detection of the KSTAR PF coils

  • Kim, Jinsub;An, Seok Chan;Ko, Tae Kuk;Chu, Yong
    • Progress in Superconductivity and Cryogenics
    • /
    • v.18 no.3
    • /
    • pp.25-29
    • /
    • 2016
  • A quench detection system of KSTAR Poloidal Field (PF) coils is inevitable for stable operation because normal zone generates overheating during quench occurrence. Recently, new voltage quench detection method, combination of Central Difference Averaging (CDA) and Mutual Inductance Compensation (MIK) for compensating mutual inductive voltage more effectively than conventional voltage detection method, has been suggested and studied. For better performance of mutual induction cancellation by adjacent coils of CDA+MIK method for KSTAR coil system, balance coefficients of CDA must be estimated and adjusted preferentially. In this paper, the balance coefficients of CDA for KSTAR PF coils were numerically estimated. The estimated result was adopted and tested by using simulation. The CDA method adopting balance coefficients effectively eliminated mutual inductive voltage, and also it is expected to improve performance of CDA+MIK method for quench detection of KSTAR PF coils.

The quench detection technique of the superconducting magnet using an AE sensor (AE센서를 이용한 초전도자석의 퀜치 검출기법)

  • Kim, Ho-Min;Lee, Bang-Woo;Oh, Il-Sung;Lee, Hai-Gun;Iwasa, Yukikazu
    • Proceedings of the KIEE Conference
    • /
    • 2004.07c
    • /
    • pp.1748-1750
    • /
    • 2004
  • This paper deals with the detection method of the Quench phenomenon for superconducting magnet using the Acoustic Emission (AE) sensor. AE sensor is the elements, which is used to change the Acoustic signal to the voltage value. This signal may be used to detect whether the superconducting magnet has been at the Quench state or not. Recently, the development of the Quench detection technique, which is the using voltage and current signals, fiber-optic sensor, and so on, for the superconducting applications is widely studying. This method for the Quench detection of the superconducting magnet is also studying at some kinds of institute in Japan and the united state. Because of the large-scale superconducting magnet like International Thermonuclear Experimental Reactor(ITER) is charged a lot of energy, when the Quench phenomenon is being at the superconducting magnet it is happen to the problem of the protection for the applications. In this paper, we concluded that the Quench detection was possible when the mechanical stress by means of the local heat is generated at the part of inside superconducting magnets.

  • PDF

Quench Analysis and Operational Characteristics of the Quench Detection System for the KSTAR PF Superconducting Coils (펄스전류 운전에 따른 KSTAR PF 초전도자석의 퀜치 분석 및 퀜치 검출 시스템 운전 특성)

  • Chu, Y.;Yonekawa, H.;Kim, Y.O.;Park, K.R.;Lee, H.J.;Oh, Y.K.
    • Progress in Superconductivity and Cryogenics
    • /
    • v.11 no.3
    • /
    • pp.20-25
    • /
    • 2009
  • The quench detection system of the KSTAR (Korea Superconducting Tokamak Advanced Research) primarily uses the resistive voltage measurement due to a quench. This method is to detect the resistive voltage generated by a quench, which is continuously maintained above the preset voltage threshold for a given holding time. As the KSTAR PF (Poloidal Field) coils are operated in the pulse current mode, the large inductive voltages are generated. Therefore the voltage threshold and the quench holding time should be determined by considering both the inductive voltages measured during the operation, and the maximum conductor temperature rise through the quench analysis. In this paper, the compensation methods for minimizing the inductive voltages are presented for the KSTAR PF coils. The quench hot spot analysis of the PF coils was carried out by the analytical and numerical methods for determining the proper values of the quench voltage threshold and the allowable quench protection delay time.

Study on quench detection of the KSTAR CS coil with CDA+MIK compensation of inductive voltages

  • An, Seok Chan;Kim, Jinsub;Ko, Tae Kuk;Chu, Yong
    • Progress in Superconductivity and Cryogenics
    • /
    • v.18 no.1
    • /
    • pp.55-58
    • /
    • 2016
  • Quench Detection System (QDS) is essential to guarantee the stable operation of the Korea Superconducting Tokamak Advanced Research (KSTAR) Poloidal Field (PF) magnet system because the stored energy in the magnet system is very large. For the fast response, voltage-based QDS has been used. Co-wound voltage sensors and balanced bridge circuits were applied to eliminate the inductive voltages generated during the plasma operation. However, as the inductive voltages are hundreds times higher than the quench detection voltage during the pulse-current operation, Central Difference Averaging (CDA) and MIK, where I and K stand for mutual coupling indexes of different circuits, which is an active cancellation of mutually generated voltages have been suggested and studied. In this paper, the CDA and MIK technique were applied to the KSTAR magnet for PF magnet quench detection. The calculated inductive voltages from the MIK and measured voltages from the CDA circuits were compared to eliminate the inductive voltages at result signals.

The Investigation for the stable control of voltage and current in a superconductor power systems (초전도 전력 시스템의 안정적 전압.전류 제어를 위한 고찰)

  • 김동준;이양주;이창열;이승제
    • Proceedings of the Korea Institute of Applied Superconductivity and Cryogenics Conference
    • /
    • 2003.02a
    • /
    • pp.193-195
    • /
    • 2003
  • In superconductor power systems, a quench detector can misrecognize oscillation about current or voltage control as a quench. So, for the correct detection of a quench, it seems need to guarantee a smooth control of current or voltage. In this paper, we have studied a control function and control parameter for smooth control of current or voltage.

  • PDF

The Study on The Complex Composition By SFCL and Power Equipments for Fault Detection in HVDC Line (HVDC 선로 내 초전도 한류기와 전력기기들의 복합 구성을 통한 고장 검출에 관한 연구)

  • Kim, Myong-Hyon;Kim, Jae-Chul
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.67 no.8
    • /
    • pp.1113-1118
    • /
    • 2018
  • Protection in HVDC(High Voltage Direct Current) have the very fast velocity of fault detection. Because Fault in HVDC has the fast propagation, large currents, high interruption cost. The focus to velocity caused possibility of errors like a detection error like a high impedance fault. In this paper, Proposed complex composition for get the reliability and velocity. That used SFCL(Super Conducting Fault Current Limiter), Protection Zone and DTS(Distributed Temperature Sensing). The SFCL was detect the fault by quench and DTS&Protection Zone were perceive the detect by variation too. To examine the proposed method, PSCAD/EMTDC simulated. The results of simulation, proposed methods could the detect of fault to whole HVDC line. And that improved the reliability of fault clearing.

A study on the Detection of Premature Quench Generated in the Process of Current Pumping in a Superconducting Power Supply (초전도 Power Supply의 전류펌핑 과정에서 발생하는 조기 퀜치발생 진단)

  • Kim, Ho-Min;Bae, Joon-Han;Noh, Jeong-Sub;Sim, Ki-Deok;Jang, Won-Kap;Ko, Tae-Kuk
    • Proceedings of the KIEE Conference
    • /
    • 1997.07a
    • /
    • pp.244-246
    • /
    • 1997
  • This paper is to analyze the Premature Quench characteristics of a rotating magnet type superconducting fluxpump and consider the method of detecting and protecting this premature quench. Practically, there is contact resistance between the fluxpump and the load, namely the S.C. magnet. The thermal increase due to the contact resistance cause the premature quench before the charging current amounts to the critical current of S.C magnet. Therefore, this paper is devoted to solving the heat equation on contact region using cylindrical coordinates and to calculating the rate of thermal increase during the current is pumped up. Doing so, the predictive value of the maximum pumping current is obtained. It has been verified that the results of simulation are coincident with those of experiment. It must be considered essentially to minimize the contact resistance in designing the S.C fluxpump system in order to protect the premature quench and improve the maximum pumping current.

  • PDF

Protection properties of HTS coil charging by rotary HTS flux pump in charging and compensation modes

  • Han, Seunghak;Kim, Ji Hyung;Chae, Yoon Seok;Quach, Huu Luong;Yoon, Yong Soo;Kim, Ho Min
    • Progress in Superconductivity and Cryogenics
    • /
    • v.23 no.4
    • /
    • pp.19-24
    • /
    • 2021
  • The low normal zone propagation velocity (NZPV) of high-temperature superconducting (HTS) tape leads to a quench protection problem in HTS magnet applications. To overcome this limitation, various studies were conducted on HTS coils without turn-to-turn insulation (NI coils) that can achieve self-protection. On the other hand, NI coils have some disadvantages such as slow charging and discharging time. Previously, the HTS coils with turn-to-turn insulation (INS coils) were operated in power supply (PS) driven mode, which requires physical contact with the external PS at room-temperature, not in persistent current mode. When a quench occurs in INS coils, the low NZPV delays quench detection and protection, thereby damaging the coils. However, the rotary HTS flux pump supplies the DC voltage to the superconducting circuit with INS coils in a non-contact manner, which causes the INS coils to operate in a persistent current mode, while enabling quench protection. In this paper, a new protection characteristic of HTS coils is investigated with INS coils charging through the rotary HTS flux pump. To experimentally verify the quench protection characteristic of the INS coil, we investigated the current magnitude of the superconducting circuit through a quench, which was intentionally generated by thermal disturbances in the INS coil under charging or steady state. Our results confirmed the protection characteristic of INS coils using a rotary HTS flux pump.

Inductance Characteristics of Tokamak Poroidal Field Coil by the Plasma Current (Plasma Current에 의한 Tokamak Poroidal Field Coil의 Inductance 특성)

  • Chung, Yoon-Do;Lee, Seung-Je;Kim, Tae-Joong;Kim, Kee-Man;Ko, Tae-Kuk
    • Proceedings of the KIEE Conference
    • /
    • 2000.07b
    • /
    • pp.801-803
    • /
    • 2000
  • The large scale magnets like thermalnuclear fusion devices are necessary for superconducting CICC cable, When the Cable In Conduit Conductors(CICC) is occurred by the external turbulence, the CICC occurs to quench, The CICC can be broken because the CICC spends all energy in the quench-happened spot. Therefore, it is necessary to develop measurement systems of the quench detection. The measurement systems of the relative good degree of efficiency are the voltage tap sensors. The weak points of voltage tap sensors are effected by EMF noise and inductance. The thermalnuclear fusion devices easily can't measure inductance value because of plasma current. In the experiment, The value of inductance was estimated by FEM techniques and the decrement of Inductance value measured as long as remaining plasma current.

  • PDF