• 제목/요약/키워드: quasi-steady

검색결과 320건 처리시간 0.038초

보조 권선형 능동 스너버를 적용하여 낮은 스위치 서지 전압 특성을 갖는 유사 공진형 컨버터에 관한 연구 (A Study on Quasi Resonant Converter with Low Switching Surge Voltage Characteristics by Applying Auxiliary Winding Type Active Snubber)

  • 안태영
    • 반도체디스플레이기술학회지
    • /
    • 제17권4호
    • /
    • pp.56-61
    • /
    • 2018
  • In this paper, a new type of active snubber was proposed to lower the excessive rated voltage of the clamp capacitor which was a problem in the conventional circuit by applying auxiliary winding into the active snubber. A simplified equivalent circuit of the proposed snubber was derived by applying it to QR flyback converter, and the equivalent circuits for each switch state was shown under the steady-state condition. In addition, the maximum voltage of the clamp capacitor as well as the main switch was found by using the steady-state equations. In particular, it was found that the clamp capacitor voltage could be controlled by the auxiliary winding ratio. In order to verify the utility and practicality of the proposed converter with auxiliary winding type active snubber circuit, a prototype with an output voltage of 19V and a maximum load current of 6A was produced and the results were reported.

배수시간과 격자크기와 반동력학적 또는 동력학적 습윤지수에 대한 연구 (The Analysis of Drainage Time and Resolution of the Quasi-dynamic and Dynamic Wetness Index)

  • 김상현;한지영;이가영;김남원
    • 한국수자원학회논문집
    • /
    • 제36권6호
    • /
    • pp.949-960
    • /
    • 2003
  • 정상상태 가정을 완화시킨 습윤지수의 해상도 문제가 수치지형모형에서 다루어졌다. 반 동역학적 습은지수와 동력학적 습윤지수의 변화성을 수치고도모형의 격자 크기와 배수시간을 변화시키면서, 공간적 통계적으로 고찰하였다. 변화하는 배수시간과 격자크기에 따라 습윤지수의 구조화 양상이 관찰 되었다. 설마천 유역의 적용결과 비교적 짧은 배수시간에서는 습윤도의 천이성이 관찰되었고, 10,000 시간 이상의 배수 시간에서는 통계적 분석 결과가 정상상태의 특성으로 수렴함을 보여주고 있다. 반 동역학적 및 동역학적 습윤지수의 확률밀도 함수들은 계산결과의 안정성과 일관성에 관련이 있는 경계 격자 크기가 존재함을 보여주고 있다.

유사 동력학적 습윤지수와 동력학적 습윤지수의 개발과 적용 (The Development and Application of the Quasi-dynamic Wetness Index and the Dynamic Wetness Index)

  • 한지영;김상현;김남원;김현준
    • 한국수자원학회논문집
    • /
    • 제36권6호
    • /
    • pp.961-969
    • /
    • 2003
  • 토양수분 분포의 시공간적인 예측을 위하여 유사 동력학 상태의 습윤지수 계산과정을 정리하였고, 우량 자료를 회귀적분한 동력학적 습윤지수의 계산 알고리즘을 개발하였다. 설마천 유역의 수치고도 모형과 2년간의 우량자료를 활용하여 동력학적 상태의 습윤지수의 시ㆍ공간적인 거동을 분석하였다. 공간적인 거동은 동력학적인 습윤지수가 유사 동력학적 상태나 정적인 습윤지수와 비교하여 흐름분산 특성이 강조된 분포특성을 보여주었다. 통계적인 특성으로는 시간이 경과함에 따라 유사동력학적 습윤지수나 동력학적 습윤지수 모두 정상상태 습윤지수에 근접하나, 동력학적 습윤지수의 경우 두 개의 상이한 분포특성이 나타났다.

An Active Auxiliary Quasi-Resonant Commutation Block Snubber-Assisted Three Phase Voltage Source Soft Switching PFC Rectifier using IGBTs

  • Hiraki Eiji;Nakaoka Mutsuo;Sugimoto Shigeyuki;Ogawa Shigeaki
    • Journal of Power Electronics
    • /
    • 제5권1호
    • /
    • pp.29-35
    • /
    • 2005
  • This paper presents a novel prototype of an active auxiliary quasi-resonant snubber(Auxiliary Quasi-Resonant Commutation Block-Link; ARCB)-assisted three phase voltage source soft switching space voltage vector modulated PFC rectifier, which uses Zero Voltage Soft Switching (ZVS) commutation. The operating principles of this digitally-controlled three phase soft switching PWM-PFC rectifier system with an instantaneous power feedback scheme are illustrated and its steady-state performance is evaluated using computer-aided simulation analysis.

수평 환형 공간에서의 중간 Prandtl 수 유체의 혼돈 열대류: Pr=0.2 (Chaotic Thermal Convection of a Intermediate Prandtl-Number Fluid in a Horizontal Annulus: Pr=0.2)

  • 유주식;김용진
    • 대한기계학회논문집B
    • /
    • 제25권3호
    • /
    • pp.433-441
    • /
    • 2001
  • Natural convection of a fluid with intermediate Prand시 number of Pr=0.2 in a horizontal annulus is considered, and the bifurcation phenomena and chaotic flows are numerically investigated. The unsteady two-dimensional streamfunction-vorticity equation is solved with finite difference method. The steady downward flow with two counter-rotating eddies bifurcates to a simple periodic flow with a fundamental frequency. And afterwards, second Hopf bifurcation occurs, and a quasi-periodic flow with two incommensurable frequencies appears. However, a new time-periodic flow is established after experiencing quasi-periodic states. As Rayleigh number is increased further, the chaotic flow regime is reached after a sequence of successive Hopf bifurcation to quasi-periodic and chaotic flow regimes. A scenario similar to the Ruelle-Takens-Newhouse scenario of the onset of chaos is observed.

Bidirectional Quasi-Cuk DC/DC Converter with Reduced Voltage Stress on Capacitor and Capability of Changing the Output Polarity

  • Asl, Elias Shokati;Sabahi, Mehran
    • Journal of Electrical Engineering and Technology
    • /
    • 제12권3호
    • /
    • pp.1108-1113
    • /
    • 2017
  • In this paper, a bidirectional topology for quasi-Cuk dc/dc converter with capability of zero-voltage and zero-current-switching (ZVZCS) is proposed. The bidirectional quasi-Cuk (BQ-Cuk) converter has different voltage and current transfer ratio, reduced voltage stress on capacitor and capability of changing the output polarity in comparison with conventional bidirectional Cuk converter. In this paper, steady-state analysis of the quasi-Cuk converter with capability of ZVZCS in turn-on is presented. Then, critical inductances for transient from this operation to two new operations are calculated. Next, besides values designing of used elements, maximum and minimum value of their current and voltage are calculated. Finally, experimental results to verify the accuracy of the proposed converter in different operating modes are presented.

An Analytical Investigation on the Build-up of the Temperature Field due to a Point Heat Source in Shallow Coastal Water with Oscillatory Alongshore-flow

  • Jung, Kyung-Tae;Kim, Chong-Hak;Jang, Chan-Joo;Lee, Ho-Jin;Kang, Sok-Kuh;Yjm, Ki-Dai
    • Ocean and Polar Research
    • /
    • 제25권1호
    • /
    • pp.63-74
    • /
    • 2003
  • The build-up of the heat field in shallow coastal water due to a point source has been investigated using an analytical solution of a time-integral form derived by extending the solutions by Holley(1969) and also presented in Harleman (1971). The uniform water depth is assumed with non-isotropic turbulent dispersion. The alongshore-flow is assumed to be uni-directional, spatially uniform and oscillatory. Due to the presence of the oscillatory alongshore-flow, the heat build-up occurs in an oscillatory manner, and the excess temperature thereby fluctuates in that course and even in the quasi-steady state. A series of calculations reveal that proper choices of the decay coefficient as well as dispersion coefficients are critical to the reliable prediction of the excess temperature field. The dispersion coefficients determine the absolute values of the excess temperature and characterize the shoreline profile, particularly within the tidal excursion distance, while the decay coefficient determines the absolute value of the excess temperature and the convergence rate to that of the quasi-steady state. Within the e-folding time scale $1/k_d$ (where $k_d$ is the heat decay coefficient), heat build-up occurs more than 90% of the quasi-steady state values in a region within a tidal excursion distance (L), while occurs increasingly less the farther we go to the downstream direction (about 80% at 1.25L, and 70% at 1.5L). Calculations with onshore and offshore discharges indicate that thermal spreading in the direction of the shoreline is reduced as the shoreline constraint which controls the lateral mixing is reduced. The importance of collecting long-term records of in situ meteorological conditions and clarifying the definition of the heat loss coefficient is addressed. Interactive use of analytical and numerical modeling is recommended as a desirable way to obtain a reliable estimate of the far-field excess temperature along with extensive field measurements.

1MHZ 공진형 DC - DC 콘버터 (ZERO - VOLTAGE - SWITCHED QUASI - RESONANT DC - DC CONVERTER WITH 1MHZ SWITCHING FREQUENCY)

  • 이윤종;김희준;안태영
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1988년도 추계학술대회 논문집 학회본부
    • /
    • pp.381-384
    • /
    • 1988
  • This paper analysed basic operation in Zero-voltages-switching quasi-resonant buck converter and considered steady state characteristics. Especially, it is confirmed that converter operating at maximum 1MHz switching frequency in load characteristics. In this paper, a novel slope method is proposed and implemented in regulation characteristics analysis. It is proved that experimenental results coincide with theory results.

  • PDF

Cost Effective Quasi-Resonant Soft Switching PWM High Frequency Inverter With Minimum Circuit Components for Consumer IH Cooker and Steamer

  • Sugimura, Hisayuki;Eid, Ahmad-M.;Nakaoka, M.;Lee, H.W.
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2005년도 춘계학술대회 논문집 전기기기 및 에너지변환시스템부문
    • /
    • pp.134-139
    • /
    • 2005
  • This paper presents a cost effective quasi-resonant soft-switching PWM high frequency inverter with minimum circuit components. This inverter can achieve wider soft commutation, simpler power circuit configuration, smaller volumetric size, lower cost and wider power regulation range, higher-efficiency as compared with single ended quasi-resonant ZVS-PFM inverter and active voltage clamped quasi-resonant ZVS-PWM inverter. The operation principle of the proposed inverter is described on the basis of the simulation and experimental results, together with its operating performances in steady state. The operating performances of this unique proposed high frequency inverter based on ZVS and ZCS arms-related soft commutation principle is evaluated and discussed as compared with the active voltage-clamped ZVS-PWM inverter and a conventional single-ended ZVS-PFM inverter. The practical effectiveness of a novel type quasi-resonant soft-switching PWM high frequency inverter using IGBT is actually proved for consumer induction heated appliances as rice cooker, hot water producer, steamer and super heated steamer. The extended bidirectional circuit topology of quasi-resonant PWM high frequency inverter with minimum circuit components is demonstrated, which operate as the direct frequency changer.

  • PDF