• Title/Summary/Keyword: quantitative evaluation method

Search Result 1,410, Processing Time 0.035 seconds

A Study on Evaluation of Modulus of Horizontal Subgrade Reaction through Field Test and Numerical Analysis (현장시험과 수치해석을 통한 수평지반반력계수 산정에 관한 연구)

  • Kang, Byungyun;Park, Minchul;Lee, Sihyung;Jang, Kisoo;Koo, Jagap;Park, Kyunghan
    • Journal of the Korean GEO-environmental Society
    • /
    • v.17 no.4
    • /
    • pp.5-15
    • /
    • 2016
  • For achieving stability and economic construction at a retaining wall construction site, quantitative parameters of soil properties with excavation steps coincides with the actual field site. The main parameters of retaining wall design such as deformation modulus and modulus of horizontal subgrade reaction are common with N value of standard penetration test. Therefore, this study is compared and analyzed about the mutual relationship which is SPT, PBT and PMT for overcoming inconsistency of the existing retaining wall design generalized. In addition, modulus of horizontal subgrade reaction and reduction factor with excavation steps are proposed through back analysis of elasto-plasticity and finite element method with actual field monitoring data. Finally, it is purpose that parameter errors are reduced for applying effective retaining wall design at a construction small and medium-sized.

Micro-imaging techniques for evaluation of plastic microfluidic chip

  • Kim, Jung-Kyung;Hyunwoo Bang;Lee, Yongku;Chanil Chung;Yoo, Jung-Yul;Yang, Sang-Sik;Kim, Jin-Seung;Park, Sekwang;Chang, Jun-Keun
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • v.1 no.4
    • /
    • pp.239-247
    • /
    • 2001
  • The Fluorescence-Activated Cell Sorter (FACS) is a well-established instrument used for identifying, enumerating, classifying and sorting cells by their physical and optical characteristics. For a miniaturized FACS device, a disposable plastic microchip has been developed which has a hydrodynamic focusing chamber using soft lithography. As the characteristics of the spatially confined sample stream have an effect on sample throughput, detection efficiency, and the accuracy of cell sorting, systematic fluid dynamic studies are required. Flow visualization is conducted with a laser scanning confocal microscopy (LSCM), and three-dimensional flow structure of the focused sample stream is reconstructed from 2D slices acquired at $1\mutextrm{m}$ intervals in depth. It was observed that the flow structure in the focusing chamber is skewed by unsymmetrical velocity profile arising from trapezoidal cross section of the microchannel. For a quantitative analysis of a microscopic flow structure, Confocal Micro-PIV system has been developed to evaluate the accelerated flow field in the focusing chamber. This study proposes a method which defines the depth of the measurement volume using a detection pinhole. The trajectories of red blood cells (RBCs) and their interactions with surrounding flow field in the squeezed sample stream are evaluated to find optimal shape of the focusing chamber and fluid manipulation scheme for stable cell transporting, efficient detection, and sorting

  • PDF

Quantification of the tug-back by measuring the pulling force and micro computed tomographic evaluation

  • Jeon, Su-Jin;Moon, Young-Mi;Seo, Min-Seock
    • Restorative Dentistry and Endodontics
    • /
    • v.42 no.4
    • /
    • pp.273-281
    • /
    • 2017
  • Objectives: The aims of this study were to quantify tug-back by measuring the pulling force and investigate the correlation of clinical tug-back pulling force with in vitro gutta-percha (GP) cone adaptation score using micro-computed tomography (${\mu}CT$). Materials and Methods: Twenty-eight roots from human single-rooted teeth were divided into 2 groups. In the ProTaper Next (PTN) group, root canals were prepared with PTN, and in the ProFile (PF) group, root canals were prepared using PF (n = 14). The degree of tug-back was scored after selecting taper-matched GP cones. A novel method using a spring balance was designed to quantify the tug-back by measuring the pulling force. The correlation between tug-back scores, pulling force, and percentage of the gutta-percha occupied area (pGPOA) within apical 3 mm was investigated using ${\mu}CT$. The data were analyzed using Pearson's correlation analysis, one-way analysis of variance (ANOVA) and Tukey's test. Results: Specimens with a strong tug-back had a mean pulling force of 1.24 N (range, 0.15-1.70 N). This study showed a positive correlation between tug-back score, pulling force, and pGPOA. However, there was no significant difference in these factors between the PTN and PF groups. Regardless of the groups, pGPOA and pulling force were significantly higher in the specimens with a higher tug-back score (p < 0.05). Conclusions: The degree of subjective tug-back was a definitive determinant for master cone adaptation in the root canal. The use of the tug-back scoring system and pulling force allows the interpretation of subjective tug-back in a more objective and quantitative manner.

Toxic Evaluation and Chromatographic Analysis of Cucurbitacin D and F from Sorbaria sorbifolia (쉬땅나무(Sorbaria sorbifolia) 성분으로서 cucurbitacin D, F의 독성평가 및 정량)

  • Lee, Sang-Myung;Lee, Cheal-Gyu
    • Analytical Science and Technology
    • /
    • v.14 no.2
    • /
    • pp.191-195
    • /
    • 2001
  • Cucurbitacin D and F, the protostane type triterpenoid of S. sorbifolia, were isolated with chromatograpic method and used as the standard substances for quantitative analysis. The compounds were identified with $^1H$-NMR, FAB-MS and UV spectrophotometer. They were separated on YMC-Pack ODS-AQ(303)[$250{\times}4.6mm$ I.D., $S-5{\mu}m$, 120A] column by HPLC. Cucurbitacin F was detected at 10.73mg/kg in cortex of S. sorbifolia, but cucurbitacin D was not. The compounds were shown to exihibit significant cytotoxicity($ED_{50}$<$0.1{\mu}g/mL$) against several tumor cell lines and acute toxicity(cucurbitacin D: 4.7mg/kg/day, cucurbitacin F: 2.5mg/kg/day) against BDF-1 mouse.

  • PDF

NEW QUANTITATIVE MEASURING TECHNIQUE FOR MICROLEAKAGE OF THE RESTORED TOOTH THROUGH 3D RECONSTRUCTION (3차원 재구성법을 이용한 수복물의 정량적 미세누출도 측정)

  • Ha, Sang-Yoon;Shin, Dong-Hoon
    • Restorative Dentistry and Endodontics
    • /
    • v.29 no.5
    • /
    • pp.413-422
    • /
    • 2004
  • Established microleakage tests have their own disadvantages. In this study, 3D reconstruction method was tried to overcome these disadvantages. Four types of microleakage tests were used and relationships among them were estimated: penetrated dye volume: marginal adaptability: degree of dye penetration and relative penetrated length to cavity wall. Twenty-four Class V cavities were bulk filled with composite (Esthet X) following surface treatments: N group (no treatment): E group (etching only): T group (etching + Prime & Bond NT). 50% silver nitrate was used as a dye solution after thermocycling ($5^{\circ}C{\;}&{\;}55^{\circ}C$, 1.000 times). Teeth were serially ground with a thickness of 0.2 mm. Volume of dye penetration was estimated from a three-dimensionally reconstructed image with a software (3D-DOCTOR). Percentage of margin without gap was estimated from SEM and degree of dye penetration and the relative length of dye penetration to overall cavity wall were also estimated. ANOVA and Scheffe test for dye volume, Kruskal-Wallis and Mann-Whitney test for marginal quality, Spearman's rho test for checking of relationships among methods were used. The results were as follows: 1. Dye penetration could be seen from several directions, furthermore, its volumetric estimation was possible. 2. Reverse relationship was found between dye volume and marginal quality (r = -0.881/ p = 0.004). 3. Very low relationship was seen between dye volume and two-dimensional tests (degree of dye penetration and relative length). However, 2D evaluation methods showed high relationship (p = 0.002-0.054) each other. 4. Three times vertical section could be recommended as a 2D test.

Calculation of Combustion Stability Limits Using Linear Stability Analysis in Liquid Rocket Engines (액체 로켓엔진에서 선형 연소 불안정 해석을 이용한 연소 안정한계 곡선 계산)

  • Sohn, Chae-Hoon;Moon, Yoon-Wan;Huh, Hwan-Il
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.32 no.10
    • /
    • pp.93-101
    • /
    • 2004
  • A method to calculate stability limits is investigated to predict the characteristics of high-frequency combustion instability in liquid-propellant rocket engine. It is based on the theory of linear stability analysis proposed in previous works and useful to predict combustion stability at the beginning stage of engine development. The system of equations governing reactive flow in combustor has the simplified and linearized forms. The overall equation expressing stability limits is adopted. The procedures to evaluate quantitatively each term included in the equation are proposed. The thermo-chemical properties and flow variables required in the evaluation can be obtained from calculation of thermodynamic equilibrium, CFD results, and experimental test data. Based on the existent data, stability limits are calculated with actual rocket engine (KSR-III rocket engine). The present calculations show the reasonable stability limits in a quantitative manner and the stability characteristics of the engine are discussed. The prediction from linear stability analysis could be serve as the first approximation to the true prediction.

TOXICOLOGICAL STUDIES ON RAW AND PROCESSED (PREBREWED) ACONITI TUBERS; ACUTE, SUBACUTE TOXICITY STUDIES AND ASSAY OF ACONITINE ALKALOIDS (生附子와 修治附子에 관한 毒性연구 : 급성 및 아급성 독성과 Aconitine 알칼로이드 함량분석)

  • Park, Han-Soo;Kim, Seung-Hee;Kim, Pu-Young;Chang, Il-Moo
    • Toxicological Research
    • /
    • v.6 no.1
    • /
    • pp.41-49
    • /
    • 1990
  • Aconiti Tuber is the root of Aconitum sp (Ranunclaceae) which has been considered as one of the most important medicinal plant having cordiotonic, diuretic and analgesic effect. On the other hand, it has been known that Aconiti Tuber contained toxic agent, aconitine alkaloids so that only processed Aconiti Tubers have been used as herbal drug traditionally. For the safety evaluation of processed Aconiti Tuber, quantitative determination of aconitine and acute, subacute toxicity test were performed on 5 commercial processed Aconiti Tubers. Arapid and precise method using HPLC has been developed for the separation and determination of aconitine. Samples were extracted with hydrochloric acid (pH3) and hot water decoction. In case of d-HCL extracts, the contents of aconitine were from 0.08 mg/g to trace. But in case of hot water decoction extracts, the contents of aconitine were not detected. For the investigation of Aconiti Tuber toxicity in rats, hot water decoction samples and methanol extracts were tested. 1) Acute toxicity test Hot water decoction sample and methanol extracts from Aconiti Tuber did not show any toxic effects in rats by an oral administration. $LD_50values of 2 extracts were above 10.0 g/kg. 2) Subacute toxicity study In the repeated administration study, hot water decoction samples were given orally to Sprague-Dawlay rats for 2 week at daily doses of 5.0 g/kg. The results are as follows; No toxic manifestation, body weight changes and lethality were observed during wxperimental period. There were no significant changes in serum enzyme activities such as GOT, GPT, LDH, ALP between treated and control groups. However CPK values were decreased in the Subuja-treated group. (P<0.01). In addition, no gross and microscopic changes were noted in Aconiti Tuber-treated groups.

  • PDF

Analysis of Organochlorine Pesticide, in the Presence of Polychlorinated Biphenyls(PCBs) I. Florisil Column Separation of the Pesticides-PCBs Mixture (Polychlorinated Biphenyls(PCBs) 존재하에 유기염소계 살충제의 잔류분 분석 1. Florisil Column에 의한 농약과 PCBs의 분리)

  • Park C. K.;Lee C. Y.;Park R. D.
    • Korean journal of applied entomology
    • /
    • v.16 no.4 s.33
    • /
    • pp.221-227
    • /
    • 1977
  • Polychlorinated Biphenyls (PCBs) interfere with gas chromatographic analysis of multiple organochlorine pesticide residues. In the present work, existing Florisil column chromatographic method has been modified as to improve separation of organochlorine pesticides and their metabolites from PCBs. It was amply demonstrated that separation of $\alpha-BHC,\; \gamma-BHC$ Heptachlor epoxide Dieldrin, p.p-DDD, p.p'-DDT from PCBs such as Aroclor 1254 is complete and recovery of the pesticides is found quantitative. Aldrin and Heptachlor in the Aroclor eluant can be separately analyzed by comparison of the chromatographic pattern of standard Aroclor 1254 with that of Aroclor 1254 a dmixed with the two pesticides. The Florsil column technique can be utilized in the routine evaluation of the organochlorine pesticide residues by gas chromatography.

  • PDF

Evaluation of Grinding Effects on the Extraction of Photosynthetic Pigments for HPLC Analysis (광합성 색소의 HPLC 분석을 위한 여과지 분쇄 효과 평가)

  • Jang, Su Jin;Park, Mi Ok
    • The Sea:JOURNAL OF THE KOREAN SOCIETY OF OCEANOGRAPHY
    • /
    • v.20 no.2
    • /
    • pp.71-77
    • /
    • 2015
  • High-Performance Liquid Chromatography (HPLC) is a widely used method for measuring the concentration of chlorophyll a as an indicator for estimating phytoplankton biomass and primary production and also for identifying carotenoids to determine phytoplankton composition. However, tissue grinding procedure requires a lot of time and experience in the analysis of multiple sample. Accordingly, we measured the concentrations of photosynthetic pigments before and after the grinding, in order to understand the grinding effects on the quantitative analysis of chlorophylls and carotenoids using samples from southwestern East Sea. When tissue grinding procedure was omitted, we found that Chl a concentrations were underestimated up to 45% in average. Also, concentrations of Zeaxanthin, 19'-butanoyloxyfucoxanthin, 19'-hexanoyloxyfucoxanthin, biomarkers of pico and nano-size phytoplankton, were underestimated up to maximum 77~85% without grinding. We found that the smaller the phytoplankton, the bigger underestimation of their biomarker pigments concentration is likely to happen due to the incomplete extraction. Thus, tissue grinding procedure should be included for HPLC analysis in all cases, to prevent the underestimation of not only Chl a but also carotenoids pigments.

A Study on Evaluation for Sampling and Analytical Methods of Diatomaceous Earth Dust (규조토 분진 측정 및 분석 방법의 비교에 관한 연구)

  • Lim, Hyun Sul;Kim, Ji Yong;Cheong, Hoe Kyeong
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.5 no.2
    • /
    • pp.212-225
    • /
    • 1995
  • This study was performed in a diatomite factory located at Pohang City, Kyeongsangbuk-Do. The major objectives were to evaluate sampling and analytical methods of diatomaceous earth dust. Concentrations of total and respirable diatomaceous earth dust were measured. Size distribution of dust was analyzed by a personal cascade impactor and the particle size analyzer which is an application of multiple diffraction method. Also crystalline silica in respirable and total dust samples was analyzed quantitatively by X-ray diffraction and Fourie Transform Infrared Spectroscopy(FTIR). The results were as follows: The airborne total and respirable dust concentrations, particle size distribution, and cristalline silica(quartz) concentrations showed approximately a log-normal distribution. The means of totaldust concentrations at flour maufacturing, fire brick grinding and packaging processes exceeded the Korean and American Conference of Governmental Industrial Hygienists standards, $10mg/m^3$. The size distribution of diatomaceous earth dust was log-normal and identified as the rspirable particle mass and thoracic particle mass. The crystalline silica in respirable and total dust samples was identified to quartz and contained about 10 % in those samples. Finally, it is necessary to study the applicability of multiple diffraction for particle size distribution to compare the ACGIH's size selective sampling with other materials containing crystalline silica. Also, advanced quantitative study to X-ray diffraction and FTIR methods shoud be carried out 10 verify general and specific characteristics for respirable crystalline silica.

  • PDF