• Title/Summary/Keyword: quantitative GC analysis

Search Result 197, Processing Time 0.025 seconds

Analysis Method of Volatile Sulfur Compounds Utilizing Separation Column and Metal Oxide Semiconductor Gas Sensor

  • Han-Soo Kim;Inho Kim;Eun Duck Park;Sang-Do Han
    • Journal of Sensor Science and Technology
    • /
    • v.33 no.3
    • /
    • pp.125-133
    • /
    • 2024
  • Gas chromatography (GC) separation technology and metal oxide semiconductor (MOS) gas sensors have been integrated for the effective analysis of volatile sulfur compounds (VSCs) such as H2S, CH3SH, (CH3)2S, and (CH3)2S2. The separation and detection characteristics of the GC/MOS system using diluted standard gases were investigated for the qualitative and quantitative analysis of VSCs. The typical concentrations of the standard gases were 0.1, 0.5, 1.0, 5.0, and 10.0 ppm. The GC/MOS system successfully separated H2S, CH3SH, (CH3)2S, and (CH3)2S2 using a celite-filled column. The reproducibility of the retention time measurements was at a 3% relative standard deviation level, and the correlation coefficient (R2) for the VSC concentration was greater than 0.99. In addition, the chromatograms of single and mixed gases were almost identical.

Effect of Different GC Columns on the Quantitative Analysis of Long Chain Alkyl Diols (LCDs) (특성이 다른 GC 컬럼이 long chain alkyl diols (LCDs)의 정량 분석에 미치는 영향)

  • GAL, JONG-KU;KIM, JUNG-HYUN;NAM, SEUNG-IL;SHIN, KYUNG-HOON
    • The Sea:JOURNAL OF THE KOREAN SOCIETY OF OCEANOGRAPHY
    • /
    • v.22 no.2
    • /
    • pp.45-55
    • /
    • 2017
  • Long chain alkyl diols (LCDs) have been reported in sediments from various marine environments. Rampen et al. (2012) introduced the paleo-sea surface temperature (SST) proxy, Long chain Diol Index (LDI) based on the relative abundance of $C_{30}$ 1,15-diol, $C_{28}$ 1,13-diol, and $C_{30}$ 1,13-diol. In general, CP-Sil5CB and DB-5ms columns have been used for the quantitative and qualitative analysis of LCDs with a GC-MS. In this study, we examined the effect of three different columns (CP-Sil5CB, HP-5ms and DB-5) on the quantitative analysis of LCDs using marine sediments from the East Sea of Korea and the western Arctic Ocean. In general, our study showed that the results of CP-Sil5CB differed significantly from those of HP-5ms and DB-5. However, the differences of the LDI-derived SSTs among three columns were $0.1-0.2^{\circ}C$ for the East Sea and $0.2-0.7^{\circ}C$ for the western Arctic Ocean, which were well within the calibration error range (${\pm}1{\sigma}$). Accordingly, our study showed that the use of different columns resulted in significant differences of LCDs concentrations, but its effect on the LDI was relatively insignificant. Therefore, it appears that the different columns can be used for the paleo-SST reconstruction in the East Sea and the western Arctic Ocean using the LDI proxy.

An Improved Analytical Method for the Determination of Qualitative and Quantitative Characteristics of Di- and Trisaccharides in Honey using GC and GC/MS (GC 및 GC/MS에 의한 벌꿀 중의 이·삼당류 정성 및 정량 특성과 개선된 동시분석방법의 확립)

  • Kim, Jong-Bae;Jang, Eun-Suk;Kim, In-Suk;Lee, Hee-Jin;Lee, Hye-Jeong;Seo, Hyun-Sun;Park, Nam-Pyo
    • Korean Journal of Food Science and Technology
    • /
    • v.47 no.1
    • /
    • pp.27-36
    • /
    • 2015
  • The improved analytical method with gas chromatography (GC) and GC-mass spectrometry was established to identify and quantify disaccharides and trisacchrides in honey. In this method, the analysis of trimethylsilyl (TMS), TMS-oxime and TMS-methoxime sugars takes into account the determination of a single peak of complete separation on the chromatogram. The number of possible peaks for the qualitative and quantitative determination of TMS, TMS-oxime, and TMS-methoxime sugars was 17, 22, and 25, respectively. This new analytical method allowed for the determination of diand trisaccharides in honey by TMS-oxime and TMS-methoxime derivatives. This study suggested that the improved method is more suitable and precise than the other analytical methods for the simultaneous determination of sugars in honey.

Quantitative Reconstruction of Sea Level Change Using Diatom-Based Transfer Function at Sinduk-ri, Gochang-Gun Since the Middle Holocene (규조기반 전이함수를 활용한 Holocene 중기 이후 고창군 신덕리 일대의 정량적 해수면 변동)

  • Kim, Jeong-Yun;Yoon, Soon-Ock;Yang, Dong Yoon;Hwang, Sangill
    • Journal of The Geomorphological Association of Korea
    • /
    • v.24 no.3
    • /
    • pp.13-25
    • /
    • 2017
  • This study is quantitative reconstruction of palaeo sea level records around Sinduk-ri, Gochang-Gun. 7 cores were collected from GC14 to GC18 in order to examine the entire sedimentary facies and reconstruct the sea level records. The cores were analysed by AMS, sedimentary facies, diatom and WA-pls. As a result of the diatom analysis, diatom zone were classified as No diatom zone, B1 zone, M zone and B2 zone. The result of WA-pls was that the sea level was about 1.5m lower than the present level around 6,000 BP and about 1m lower during last 5,000 BP. Thereafter, sea level rose to the present during the Mc sub-diatom zone period. Moreover, during the Md sub-diatom zone period, sea level was about 0.5m higher than the present.

NEAR INFRARED TRANSFLECTANCE SPECTROSCOPY (NIRS) IN PHYTOCHEMISTRY

  • Huck, C.W.;W.Guggenbichler;Bonn, G.K.
    • Proceedings of the Korean Society of Near Infrared Spectroscopy Conference
    • /
    • 2001.06a
    • /
    • pp.3114-3114
    • /
    • 2001
  • During the last years phytochemistry and phytopharmaceutical applications have developed rapidly and so there exists a high demand for faster and more efficient analysis techniques. Therefore we have established a near infrared transflectance spectroscopy (NIRS) method that allows a qualitative and quantitative determination of new polyphenolic pharmacological active leading compounds within a few seconds. As the NIR spectrometer has to be calibrated the compound of interest has at first to be characterized by using one or other a combination of chromatographic or electrophoretic separation techniques such as thin layer chromatography (TLC), high performance liquid chromatography (HPLC), capillary electrophoresis (CE), gas chromatography (GC) and capillary electrochromatography (CEC). Both structural elucidation and quantitative analysis of the phenolic compound is possible by direct coupling of the mentioned separation methods with a mass spectrometer (GC-MS, LC-MS/MS, CE-MS, CEC-MS) and a NMR spectrometer (LC-NMR). Furthermore the compound has to be isolated (NPLC, MPLC, prep. TLC, prep. HPLC) and its structure elucidated by spectroscopic techniques (UV, IR, HR-MS, NMR) and chemical synthesis. After that HPLC can be used to provide the reference data for the calibration step of the near infrared spectrometer. The NIRS calibration step is time consuming, which is compensated by short analysis times. After validation of the established NIRS method it is possible to determine the polyphenolic compound within seconds which allows to raise the efficiency in quality control and to reduce costs especially in the phytopharmaceutical industry.

  • PDF

Discrimination Model of Cultivation Area of Alismatis Rhizoma using a GC-MS-Based Metabolomics Approach (GC-MS 기반 대사체학 기법을 이용한 택사의 산지판별모델)

  • Leem, Jae-Yoon
    • YAKHAK HOEJI
    • /
    • v.60 no.1
    • /
    • pp.29-35
    • /
    • 2016
  • Traditional Korean medicines may be managed more scientifically, through the development of logical criterion to verify their cultivation region. It contributes to advance the industry of traditional herbal medicines. Volatile compounds were obtained from 14 samples of domestic Taeksa and 30 samples of Chinese Taeksa by steam distillation. The metabolites were identified by NIST mass spectral library in the obtained gas chromatography/mass spectrometer (GC/MS) data of 35 training samples. The multivariate statistical analysis, such as Principal Component Analysis (PCA), Partial Least Squares Discriminant Analysis (PLS-DA), and Orthogonal Partial Least Squares Discriminant Analysis (OPLS-DA), were performed based on the qualitative and quantitative data. Finally trans-(2,3-diphenylcyclopropyl)methyl phenyl sulfoxide (47.265 min), 1,2,3,4-tetrahydro-1-phenyl-naphthalene (47.781 min), spiro[4-oxatricyclo[5.3.0.0.(2,6)]decan-3-one-5,2'-cyclohexane] (54.62 min), 6-[7-nitrobenzofurazan-4-yl]amino-morphinan-4,5-epoxy (54.86 min), p-hydroxynorephedrine (55.14 min) were determined as marker metabolites to verify candidates for the origin of Taeksa. The statistical model was well established to determine the origin of Taeksa. The cultivation areas of test samples, each 3 domestic and 6 Chinese Taeksa were predicted by the established OPLS-DA model and it was confirmed that all 9 samples were precisely classified.

Quantitative Approaches for the Determination of Volatile Organic Compounds (VOC) and Its Performance Assessment in Terms of Solvent Types and the Related Matrix Effects

  • Ullah, Md. Ahsan;Kim, Ki-Hyun;Szulejko, Jan E.;Choi, Dal Woong
    • Asian Journal of Atmospheric Environment
    • /
    • v.11 no.1
    • /
    • pp.1-14
    • /
    • 2017
  • For the quantitative analysis of volatile organic compounds (VOC), the use of a proper solvent is crucial to reduce the chance of biased results or effect of interference either in direct analysis by a gas chromatograph (GC) or with thermal desorption analysis due to matrix effects, e.g., the existence of a broad solvent peak tailing that overlaps early eluters. In this work, the relative performance of different solvents has been evaluated using standards containing 19 VOCs in three different solvents (methanol, pentane, and hexane). Comparison of the response factor of the detected VOCs confirms their means for methanol and hexane higher than that of pentane by 84% and 27%, respectively. In light of the solvent vapor pressure at the initial GC column temperature ($35^{\circ}C$), the enhanced sensitivity in methanol suggests the potential role of solvent vapor expansion in the hot injector (split ON) which leads to solvent trapping on the column. In contrast, if the recurrent relationships between homologues were evaluated using an effective carbon number (ECN) additivity approach, the comparability assessed in terms of percent difference improved on the order of methanol (26.5%), hexane (6.73%), and pentane (5.24%). As such, the relative performance of GC can be affected considerably in the direct injection-based analysis of VOC due to the selection of solvent.

Isotope-Dilution Mass Spectrometry for Quantification of Urinary Active Androgens Separated by Gas Chromatography

  • Lee, Su-Hyeon;Choi, Man-Ho;Lee, Won-Yong;Chung, Bong-Chul
    • Mass Spectrometry Letters
    • /
    • v.1 no.1
    • /
    • pp.29-32
    • /
    • 2010
  • Cross reacting antibodies can cause an overestimation of the results of immunoassays. Therefore, alternative methods are needed for the accurate quantification of steroids. Gas chromatography combined with isotope-dilution mass spectrometry (GC-IDMS) is developed to quantify urinary active androgens, testosterone, epitestosterone and dihydrotestosterone, which are clinically relevant androgens to both hair-loss and prostate diseases. The method devised involves enzymatic hydrolysis with $\beta$-glucuronidase, solid-phase extraction, liquid-liquid extraction using methyl tert-butyl ether and subsequent conversion to pentafluorophenyldimethylsilyl-trimethylsilyl (flophemesyl-TMS) derivatives for sensitive and selective analysis in selected-ion monitoring mode. Flophemesyl-TMS derivatization not only eliminates matrix interference but also has a good peak resolution within a 6 min-run. A selective and sensitive GC technique with flophemesyl-TMS derivatives also allows accurate quantitative analysis of three active androgens when combined with IDMS. The limit of quantification of the three analytes was <50 pg/mL, and extraction recoveries ranged from 91.9 to 102.1%. The precision and accuracy were 1.2~6.5% and 89.0~106.7%, respectively. This GC-IDMS method can be useful for evaluating the drug efficacy and monitoring the biological processes responsible for male-pattern baldness and prostate diseases.

Quantitative Analysis of Radiation-induced Hydrocarbons in Irradiated Chicken at Various Dose Levels

  • Kim, Eun-Ah;Lee, Hae-Jung;Yang, Jae-Seung;Kim, Kyong-Su
    • Preventive Nutrition and Food Science
    • /
    • v.3 no.4
    • /
    • pp.339-343
    • /
    • 1998
  • Gamma-irradiated chicken at dose levels of 0.1 to 10 kGy was subjected to detection of radiation-induced hydrocarbons whether irradiated or not. The hydrocarbons extracted from chicken fat were separated by florishil column chromatography and identified with GC-FID and GC/MS methods. Eight kinds of hydrocarbons were identified from irradiated chicken, among which 1, 7-hexadecadiene and 8-heptadencene were detected as major compounds , Remarkably radiation-induced hydrocarbons in irradiated chiken were detected at 0.5kGy and over. The concentration of radiation-induced hydrocarbons was relatively constant during 16 weeks.

  • PDF

Simultaneous Gas Chromatographic Analysis of Ethanol and Acetic Acid in Vinegar (식초의 에탄올 및 초산 함량의 동시분석)

  • Yoon, Hee-Nam
    • Korean Journal of Food Science and Technology
    • /
    • v.30 no.6
    • /
    • pp.1247-1251
    • /
    • 1998
  • A method is developed for simultaneously determining ethanol and acetic acid in vinegars by quantitative packed-column gas chromatography. Vinegars were filtrated and directly chromatographed on a $2\;m{\times}2\;mm$ stainless steel column packed with Tenax-GC, 80/100. Ethanol, isopropy alcohol as an internal standard, and acetic acid were completely separated within 20 min of running time without any interfering peaks. The accuracy of packed column gas solid chromatography (PCGSC) was discussed compared to the analytical data by titration, high performance liquid chromatography and capillary column gas liquid chromatography (CCGLC).

  • PDF