• Title/Summary/Keyword: quality deviation

Search Result 933, Processing Time 0.033 seconds

A study on performance improvement considering the balance between corpus in Neural Machine Translation (인공신경망 기계번역에서 말뭉치 간의 균형성을 고려한 성능 향상 연구)

  • Park, Chanjun;Park, Kinam;Moon, Hyeonseok;Eo, Sugyeong;Lim, Heuiseok
    • Journal of the Korea Convergence Society
    • /
    • v.12 no.5
    • /
    • pp.23-29
    • /
    • 2021
  • Recent deep learning-based natural language processing studies are conducting research to improve performance by training large amounts of data from various sources together. However, there is a possibility that the methodology of learning by combining data from various sources into one may prevent performance improvement. In the case of machine translation, data deviation occurs due to differences in translation(liberal, literal), style(colloquial, written, formal, etc.), domains, etc. Combining these corpora into one for learning can adversely affect performance. In this paper, we propose a new Corpus Weight Balance(CWB) method that considers the balance between parallel corpora in machine translation. As a result of the experiment, the model trained with balanced corpus showed better performance than the existing model. In addition, we propose an additional corpus construction process that enables coexistence with the human translation market, which can build high-quality parallel corpus even with a monolingual corpus.

Profile and Outcome of Management of Brain Tumours in Kaduna Northwestern Nigeria

  • Danjuma, Sale;Dauda, Happy Amos;Kene, Aghadi Ifeanyi;Akau, Kache Stephen;Jinjiri, Ismail Nasiru
    • Journal of Korean Neurosurgical Society
    • /
    • v.65 no.5
    • /
    • pp.751-757
    • /
    • 2022
  • Objective : Tumours of the brain are a rare occurrence accounting for approximately 2% of all neoplasms in adults. Few studies have been done in Nigeria on the profile of brain tumours. The aim of this study is to determine the profile of brain tumours in general and determine the change in Kanofsky Performance Score (KPS) after treatment. Methods : This is a prospective hospital-based study in Kaduna. All consecutive patients over 18 years of age with diagnosis of brain tumours from January 2016 to December 2019 were included in the study. Demographic and clinical data was collected using a proforma during the study. Patients who received treatment were followed up for 12 months. The primary outcome data was the difference in the quality of life as measured by KPS at the point of first contact and at 1-month after treatment and at 12-month follow up. Data obtained was analysed with SPSS version 25.0 for Windows. Descriptive statistics was done to determine the profile. Paired t-test at 95% confidence interval was done to check for significant correlation between the mean KPS. Results : A total of 39 consecutive patients were included in the study. There was a slight male preponderance with a M : F of 1.17 : 1. Meningioma and metastasis were more common in females while gliomas and pituitary tumours were more common in males. The mean age of patients was 49.8 years and standard deviation of 11.8 years. Pituitary tumours were the most common tumours. The most common location of the tumour was frontal lobe followed by the pituitary gland. The mean duration of symptoms before neurosurgical consultation was 38 weeks. The most common presenting symptoms of patient with brain tumour was headache. The quality of life improve compare to the baseline in 81% of patient at discharge and at 1 year follow up. The overall mortality rate was 25.6%. Conclusion : The most common brain tumour in our study is pituitary tumour. Most patients present late. The most common presenting symptoms is headache. There is significant improvement in the KPS of patients following treatment. The overall mortality rate at 1-year post treatment is 25.6%.

Prioritizing Themes Using a Delphi Survey on Patient Safety Theme Reports (환자안전 주제별 보고서의 주제 우선순위 설정: 델파이 조사를 통한 분석)

  • Park, Jeong Yun;Shin, Eun-Jung;Kim, Rhieun;Kim, Sukyeong;Park, Choon-Seon;Park, Taezoon;Choi, Yun-Kyoung;Heo, Young-Hee
    • Quality Improvement in Health Care
    • /
    • v.28 no.1
    • /
    • pp.45-54
    • /
    • 2022
  • Purpose: The study aims to identify the theme list and priority criteria of patient safety theme reports in South Korea. Methods: The survey was conducted twice, and the importance of each criterion and theme was measured on a nine-point scale using the Delphi technique by a panel of 19 patient safety experts. The criteria included severity, universality, preventability, and organizational-social impact. Descriptive statistics such as frequency, percentage, mean, standard deviation, median, and interval quartile range were used to analyze the data. Results: The parameters were assigned a weighted average of 35% for severity, 20% for universality, 30% for preventability, and 15% for organizational-social impact, respectively. The final top three rankings were surgery safety, blood transfusion safety, and medication safety. In addition to expert opinion, for the theme that is selected based on the priority ranking, one to five sub-topics can be derived from the theme based on the priority ranking, societal demands, or the yearly priority list of patient safety incidents. Conclusion: It is recommended that the official patient safety center distribute the report in the form of a summary that can be utilized nationwide at medical institutions, government institutions, and other places. Updates, as well as accumulated theme reports, will serve as the baseline data for the proposal of the system and for the policy designed to implement and improve institutions' safety practices as a standard of domestic patient safety practice guidelines.

The Effect of Mixed Cultivation Using Companion Plants on the Growth and Quality of Cherry Tomatoes

  • Lee, Byoung-Kwon;Yun, Hyung Kwon;Hong, In-Kyoung;Jung, Young-Bin;Lee, Sang-Mi
    • Journal of People, Plants, and Environment
    • /
    • v.24 no.4
    • /
    • pp.311-327
    • /
    • 2021
  • Background and objective: Recent urban agriculture meets the needs of urban residents that safety and avoids using chemical pesticides. This study was conducted to identify various factors of companion planting affecting the growth of cherry tomatoes, which will promoting urban agriculture by improving socioeconomic satisfaction with gardening activities through quality. Methods: Four types of companion plants such as marigold, zinnia, spearmint and basil, that have a companion effect with growth, sugar content, and vitamin C content. We obtained the mean and standard deviation and tested the significance at a 95% confidence level (p < .05) with Duncan's multiple range test after one way ANOVA and MANOVA. Results: Compared to monoculture of cherry tomatoes, the plant growth in the treatment plots with companion planting showed a significant increase overall(p < .05), but there wasn't interaction effect among companion plants, planting ratio and type. As for the absorption of inorganic components, the companion planting showed better absorption than monoculture of cherry tomatoes, as favorable growth, and there was an interaction effect among the individual factors. The sugar content was higher than the standard sugar content of 5.8 brix in both the treatment plots at the control, and vitamin C content was higher than the control at 26.27mg/100g in all treatment plots, but there wasn't statistically significant difference. The soil pH in the cultivation plot ranges from 5.5 to 9.0 and was weakly alkaline in all treatment plots except zinnia, showing low contents of phosphoric acid, exchageable potassium, calcium and magnesium. Conclusion: This study was conducted to analyze various factors such as the growth of cherry tomatoes, contents of inorganic components, sugar content and vitamin C content of fruits, and soil analysis according to companion plants, planting type, and planting ratio. We will study sugar content by measuring the change in growth every phase of fruits.

Comparison of ultrasound-guided subacromial corticosteroid and ozone (O2-O3) injections in the treatment of chronic rotator cuff tendinopathy: a randomized clinical trial

  • Merve Orucu Atar;Nurdan Korkmaz;Sefa Gumruk Aslan;Ozge Tezen;Sinem Uyar Koylu;Yasin Demir;Serdar Kesikburun
    • The Korean Journal of Pain
    • /
    • v.36 no.1
    • /
    • pp.128-136
    • /
    • 2023
  • Background: The authors aimed to compare the effects of a one-time ultrasound (US)-guided subacromial corticosteroid injection and three-time ozone (O2-O3) injection in patients with chronic supraspinatus tendinopathy. Methods: Participants were randomly assigned to the corticosteroid group (n = 22) or ozone group (n = 22). Injections in both groups were administered into subacromial bursa with an US-guided in-plane posterolateral approach. Primary outcome measure was the change in the Western Ontario Rotator Cuff Index (WORC) score between baseline and 12-weeks post-injection. Secondary outcome measures included visual analog scale and Shoulder Pain and Disability Index scores. Assessments were recorded at baseline, and 4-weeks and 12-weeks post-injection. Results: Forty participants completed this study. Based on repeated measurement analysis of variance, a significant effect of time was found for all outcome measures in both groups. Both the groups showed clinically significant improvements in shoulder pain, quality of life, and function. Baseline, 4-week post-injection, and 12-week post-injection WORC scores (mean ± standard deviation) were 57.91 ± 18.97, 39.10 ± 20.50 and 37.22 ± 27.31 in the corticosteroid group, respectively and 69.03 ± 15.89, 39.11 ± 24.36, and 32.26 ± 24.58 in the ozone group, respectively. However, no significant group × time interaction was identified regarding all outcome measures. Conclusions: Three-time ozone injection was not superior to a one-time corticosteroid injection in patients with chronic supraspinatus tendinopathy. It might be as effective as corticosteroid injection at 4-weeks and 12-weeks post-injection in terms of relieving pain and improving quality of life and function.

The Evaluation for Attenuation Map using Low Dose in PET/CT System (PET/CT 시스템에서 감쇠지도를 만들기 위한 저선량 CT 평가)

  • Nam, So-Ra;Cho, Hyo-Min;Jung, Ji-Young;Lee, Chang-Lae;Lim, Han-Sang;Park, Hoon-Hee;Kim, Hee-Joung
    • Progress in Medical Physics
    • /
    • v.18 no.3
    • /
    • pp.134-138
    • /
    • 2007
  • The current PET/CT system with high quality CT images not only increases diagnostic value by providing anatomic localization, but also shortens the acquisition time for attenuation correction than primary PET system. All commercially available PET/CT system uses the CT scan for attenuation correction instead of the transmission scan using radioactive source such as $^{137}Cs,\;^{68}Ge$. However the CT scan may substantially increase the patient dose. The purpose of this study was to evaluate quality of PET images reconstructed by CT attenuation map using various tube currents. in this study, images were acquired for 3D Hoffman brain phantom and cylindrical phantom using GE DSTe PET/CT system. The emission data were acquired for 10 min using phantoms after injecting 44.03 MBq of $^{18}F-FDG$. The CT images for attenuation map were acquired by changing tube current from 10 mA to 95 mA with fixed exposure time of 8 sec and fixed tube voltage of 140 kVp. The PET images were reconstructed using these CT attenuation maps. Image quality of CT images was evaluated by measuring SD (standard deviation) of cylindrical phantom which was filled with water and $^{18}F-FDG$ solution. The PET images were evaluated by measuring the activity ratio between gray matter and white matter in Hoffman phantom images. SDs of CT images decrease by increasing tube current. When PET images were reconstructed using CT attenuation maps with various tube currents, the activity ratios between gray matter and white matter of PET images were almost same. These results indicated that the quality of the PET images using low dose CT data were comparable to the PET images using general dose CT data. Therefore, the use of low dose CT is recommended than the use of general dose CT, when the diagnostic high quality CT is not required. Further studies may need to be performed for other system, since this study is limited to the GE DSTe system used in this study.

  • PDF

Interlaboratory Comparison of Blood Lead Determination in Some Occupational Health Laboratories in Korea (일부 산업보건기관들의 혈중연 분석치 비교)

  • Ahn, Kyu Dong;Lee, Byung Kook
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.5 no.1
    • /
    • pp.8-15
    • /
    • 1995
  • The reliable measurement of metal in biological media in human body is one of critical indicators for the proper evaluation of its toxic effect on human health. Recently in Korea the necessity of quality assurance of measurement in occupational health and occupational hygiene fields brought out regulatory quality control program. Lead is often used as a standard metal for the program in both fields of occupational health and hygiene. During last 20 years lead poisoning was prevalent in Korea and still is one of main heavy metal poisoning and the capability of the measurement of blood lead is one of prerequisites for institute of specialized occupational health in Korea. Furthermore blood lead is most important indicator to evaluate lead burden of human exposure to lead and the reliable and accurate analysis is most needed whenever possible. To evaluate the extent of the interlaboratory differences of blood lead measurement in several well-known institute specialized in occupational health in Korea, authors prepared 68 blood samples from two storage battery industries and all samples were divided into samples with 2 ml. One set of 68 samples were analyzed by authors's laboratory(Soonchunhyang University Institute of Industrial Medicine: SIIM) and 40 samples of other set were analyzed by C University Institute of Industrial Medicine(CIIM) and the rest 28 samples of other set were analyzed by Japanese institute(K Occupational Health Center:KOHC). Authors also prepared test bovine samples which were obtained from Japanese Federation of Occupational Health Organization (JFOHO) for quality control. Authors selected 2 other well-known occupational health laboratories and one laboratory specialized for instrumental analysis. A total of 6 laboratories joined the interlaboratory comparison of blood lead measurement and the results obtained were as follows: 1. There was no significant difference in average blood lead between SIIM and CIIM in different group of blood lead concentration, and the relative standard deviation of two laboratories was less than 3.0%. On the other hand, there was also no significant difference of average blood lead between SIIM and KOHC with relative standard deviation of 6.84% as maximum. 2. Taking less than 15% difference of mean or less than 6 ug/dl difference in below 40 ug/dl in whole blood as a criteria of agreement of measurement between two laboratories, agreement rates were 87.5%(35/40) and 78.6%(22/28) between SIIM and CIIM, SIIM and KOHC respectively. 3. The correlation of blood lead between SIIM and CIIM was 0.975 (p=0.0001) and the regression equation was SIIM = 2.19 + 0.9243 ClIM, whereas the correlation between SUM and KOHC was O.965(p=0.0001) with the equation of SIIM = 1.91 + 0.9794 KOHC. 4. Taking the reference value as a dependent variable and each of 6 laboratories's measurement value as a independent variable, the determination coefficient($R^2$) of simple regression equations of blood lead measurement for bovine test samples were very high($R^2>0.99$), and the regression coefficient(${\beta}$) was between 0.972 and 1.15 which indicated fairly good agreement of measurement results.

  • PDF

Water Quality and Chlorophyll-a at the Birth Stage of a Large Reclaimed Estuarine Lake in Korea (Lake Hwaong) (간척하구호 (화옹호) 태동기의 수질과 엽록소-a 변화)

  • Kim, Ho-Sub;Chung, Mi-Hee;Choi, Chung-Il;Hwang, Soon-Jin
    • Korean Journal of Ecology and Environment
    • /
    • v.36 no.4 s.105
    • /
    • pp.455-462
    • /
    • 2003
  • This study evaluated the change of water quality and chlorophyll - a at the birth stage of a large reclaimed estuarine lake (Lake Hwaong) of which the dike was finally constructed in March, 2002. Physico -chemical parameters and chlorophyll - a were investigated along a longitudinal transect, including 3 in-lake sites and 1 out-lake site from June to November, 2002. Salinity at all in-lake sites was over 21 psu during the study period, indicating that lake is still in the seawater phase. Salinity was periodically diluted at times when precipitation was high, especially in August. Chemocline was established in July near the dam site, and correspondingly vertical profile of dissolved oxygen was very clear during that Period. Total nitrogen and phosphorus concentrations at all lake sites were in the eutrophic range, and they were especially high at the stream inlet site. Nutrients concentration was not much varied vertically but significantly varied temporally, and correlated significantly with precipitation and chlorophyll-a concentration, indicating that inflowing water from the watershed seemed not to improve lake water by dilution but cause eutrophication of the lake, and thereby stimulate phytoplankton development. Based on the analyses of nutrient ratio (N/P) and trophic state deviation, both phosphorus and nitrogen appeared to limit phytoplankton growth in the lake. Phosphorus limitation appeared to be probable at all in-lake sites with being most severe at the stream inlet site. Nitrogen limitation seemed to occur at both in-lake and out-lake sites. These results indicate that in Lake Hwaong experiencing the very early stage of a reclaiming lake, water quality and phytoplankton development appear to be affect-ed largely by salinity and hydrology and nutrients from the inflowing water. Lake biogeochemistry is still very unstable, and thus further long-term study is necessary to understand the effects of seawater to freshwater conversion on lake biology and water chemistry.

Comparison and Analysis of Photon Beam Data for Hospitals in Korea and Data for Quality Assurance of Treatment Planning System (국내 의료기관들의 광자 빔 데이터의 비교 분석 및 치료계획 시스템 정도관리자료)

  • Lee, Re-Na;Cho, Byung-Chul;Kang, Sei-Kwon
    • Progress in Medical Physics
    • /
    • v.17 no.3
    • /
    • pp.179-186
    • /
    • 2006
  • Purpose: Photon beam data of linear accelerators in Korea are collected, analyzed, and a simple method for checking and verifying the dose calculations in a TPS are suggested. Materials and Methods: Photon beam data such as output calibration condition, output factor, wedge factor, percent depth dose, beam profile, and beam quality were collected from 26 institutions in Korea. In order to verify the accuracy of dose calculation, ten sample planning tests were peformed. These Include square, elongated, and blocked fields, wedge fields, off-axis dose calculation, SSD variation. The planned data were compared to that of manual calculations. Results: The average and standard deviation of photon beam quality for 6, 10, and 15 MV were $0.576{\pm}0.005,\;0.632{\pm}0.004,\;and\;0.647{\pm}0.006$, respectively. The output factors of 6 MV photon beam measured at depth of dose maximum for $5{\times}5cm,\;15{\times}15cm,\;20{\times}20cm\;were\;0.944{\pm}0.006,\;1.031{\pm}0.006,\;and\;1.055{\pm}0.007$. For 10 MV photon beam, the values were $0.935{\pm}0.006,\;1.031{\pm}0.007,\;1.054{\pm}0.0005$. The collected data were not enough to calculate average, the output factors for 15MV photon beam with field size of $5{\times}5cm,\;15{\times}15cm,\;20{\times}20cm\;were\;0.941{\pm}0.008,\;1.032{\pm}0.004,\;1.049{\pm}0.014$. There was seven institutions $e{\times}ceeding$ tolerance when monitor unit values calculated from treatment planning system and manually were compared. The measured average MU values for the machines calibrated at SAD setup were 3 MU and 5 MU higher than the machines calibrated at SSD for 6 MV and 10 MV, respectively except the wedge case. When the wedges were inserted, the MU values to deliver 100 cGy to 5 cm depends on manufactures. When the same wedge angle was used, Siemens machine requires more MUs then Varian machine. Conclusion: In this study, photon beam data are collected and analyzed to provide a baseline value for chocking beam data and the accuracy of dose calculation for a treatment planning system.

  • PDF

Comparative Analysis of Long-term Water Quality Data Monitored in Andong and Imha Reservoirs (안동호와 임하호에서 관측한 장기 수질자료의 비교 분석)

  • Park, Sun-Jae;Choi, Seong-Mo;Park, Jong-Seok;An, Kwang-Guk
    • Korean Journal of Ecology and Environment
    • /
    • v.39 no.1 s.115
    • /
    • pp.21-31
    • /
    • 2006
  • The objectives of this study were to analyze trends of temporal water quality and trophic state in Andong and Imha reservoirs using chemical dataset during 1993 ${\sim}$ 2004, obtained from the Ministry of Environment, Korea. According to long-term limnological analyses, Suspended solids (SS) in Imha Reservoir were 2 ${\sim}$ 8 fold2 greater, than those in SS of Andong Reservoir, and the high solids increased total phosphorus (TP) and biological oxygen demand ($BOD_5$) and decreased the transparency, measured as Secchi depth (SD). Chlorophyll-a (CHL-a) increased little or decreased slightly in the both reservoirs during the high solids, resulting in reduced yields of CHL-a : TP ratios. The deviation analysis of Trophic State Index (TSI) in Imha Reservoir showed that about 70% of TSI (CHL-a)-TSI (SD) and TSI (CHL-a)-TSI(TP) values were less than zero and the lowest values were-60, indicating that influence of inorganic solids (or non-volatile solids) on phytoplankton growth was evident in Imha Reservoir and the impact was greater than that of Andong Reservoir. Inorganic solids in Imha Reservoir resulted in light limitation on phytoplankton growth and thus contributed variations in the relations among three parameters of trophic state index. Especially, seasonal data analysis of nutrients in both reservoirs showed that during the postmonsoon, mean TP concentration was Imha Reservoir greater in than that in Andong Reservoir. The higher TP concentrantion was mainly attributed to increases of inorganic solids from soil erosions and nonpoint source inputs within the watershed. The high inorganic turbidity in Imha Reservoir should be reduced for the conservation of water quality for, especially a tap water supply.