• Title/Summary/Keyword: quadrupole mass spectrometer

Search Result 83, Processing Time 0.031 seconds

The etching of $HfO_2$ thin film as the ion energy distributions in the $BCl_3/Ar$ inductively coupled plasma system ($BCl_3/Ar$ 유도 결합 플라즈마 시스템해서 이온 에너지 분포에 따른$HfO_2$ 박막 식각)

  • Kim, Gwan-Ha;Kim, Kyoung-Tae;Kim, Jong-Kyu;Woo, Jong-Chang;Kang, Chan-Min;Kim, Chang-II
    • Proceedings of the KIEE Conference
    • /
    • 2006.10a
    • /
    • pp.117-118
    • /
    • 2006
  • In this work, we investigated etching characteristics of $HfO_2$ thin film and Si using inductive coupled plasma (ICP) system. The ion energy distribution functions in an inductively coupled plasma was analyzed by quadrupole mass spectrometer with an electrostatic ion energy analyzer. The maximum etch rate of $HfO_2$ is 85.5 nm/min at a $BCl_3/(BCl_3+Ar)$ of 20% and decreased with further addition of $BCl_3$ gas. From the QMS measurements, the most dominant positive ion energy distributions (IEDs) showed a maximum at 20 % of $BCl_3$. These tendency was very similar to the etch characteristics. This result agreed with the universal energy dependency of ion enhanced chemical etching yields. And the maximum selectivity of $HfO_2$ over Si is 3.05 at a O2 addition of 2 sccm into the $BCl_3/(BCl_3+ Ar)$ of 20% plasma.

  • PDF

Silicon trench etching using inductively coupled Cl2/O2 and Cl2/N2 plasmas

  • Kim, Hyeon-Soo;Lee, Young-Jun;Young, Yeom-Geun
    • Journal of Korean Vacuum Science & Technology
    • /
    • v.2 no.2
    • /
    • pp.122-132
    • /
    • 1998
  • Characteristics of inductively coupled Cl2/O2 and Cl2/N2 plasmas and their effects on the formation of submicron deep trench etching of single crystal silicon have been investigated using Langmuir probe, quadrupole mass spectrometer (QMS), X-ray photoelectron spectroscopy (XPS), and scanning electron microscopy (SEM), Also, when silicon is etched with oxygen added chlorine plasmas, etch products recombined with oxygen such as SiClxOy emerged and Si-O bondings were found on the etched silicon surface. However, when nitrogen is added to chlorine, no etch products recombined with nitrogen nor Si-N bondings were found on the etched silicon surface. When deep silicon trenches were teached, the characteristics of Cl2/O2 and Cl2/N2 plasmas changed the thickness of the sidewall residue (passivation layer) and the etch profile. Vertical deep submicron trench profiles having the aspect ratio higher than 5 could be obtained by controlling the thickness of the residue formed on the trench sidewall using Cl2(O2/N2) plasmas.

  • PDF

다양한 Plasma 처리 방법에 의존하는 PDP Panel 내 MgO Layer의 Outgassing 특성에 관한 연구

  • 이준희;황현기;정창현;이영준;염근영
    • Proceedings of the Korean Institute of Surface Engineering Conference
    • /
    • 2003.05a
    • /
    • pp.54-54
    • /
    • 2003
  • MgO layer는 POP 패빌 내 유전증을 이온의 스퍼터링으로부터 보호하여 주며, 또한 높은 이차 전자 밤출 계수의 특성을 가지고 있어 구동 및 유지 전압을 낮춰 주는 역할을 한다. 그러나. MgO layer는 $H_20,{\;}CO_2,{\;}N_2,{\;}0_2$ 그리고 $H_2$와 같은 불순물 들을 쉽게 를착하는 단점이 있어, PDP의 특성 및 수명 단축에 영향을 줄 수 있다. 따라서, 본 연구에서는 atmospheric pressure plasma cleaning 과 low pressure i inductively coupled plasma (ICP) cleaning 처리에 의하여, 보호층으로 사용이 되는 MgO layer의 outgassing 특성을 조사하고자 한다. plasma cleaning에 의한 MgO layer 표면의 roughness와 불순물의 변화를 알아보기 위 하여 atomic force microscopy(AFM)과 x-ray p photoelectron spectroscopy(XPS)를 이용하여 측정 하였다. 또한, outgassing의 특성을 분석하기 위하여 MgO layer를 $400^{\circ}C$ 까지 온도를 가하여 온도에 따른 outgassing의 특성을 quadrupole mass spectrometer(QMS)를 이용하여 알아보았다. atmospheric pressure plasma cleaning 에서는 $He/O_2/Ar/N_2$의 gas를 사용하였으며, low pressure ICP cleaning 에 서는 Ar의 gas를 사용하였다. atmospheric pressure plasma cleaning는 low pressure ICP C cleaning과 비교해 더 낮은 outgassing을 관잘 할 수 있었으나. MgO 표면의 roughness는 low pressure ICP cleaning 후 더 낮은 것을 알 수 있었다. 또한 $He/O_2/Ar/N_2$의 gas를 사용 한 atmospheric pressure plasma cleaning 과 $Ar/O_2$의 gas를 사용한 ICP cleaning에서 이 차전자방출계수(SEEC)가 약 1.5~2.5배 증가된 것을 알 수 있었다.

  • PDF

Anti-inflammatory Activity of Standardized Fraction from Inula helenium L. via Suppression of NF-κB Pathway in RAW 264.7 Cells

  • Chun, Jaemoo;Song, Kwangho;Kim, Yeong Shik
    • Natural Product Sciences
    • /
    • v.25 no.1
    • /
    • pp.16-22
    • /
    • 2019
  • Inula helenium L. is rich source of eudesmane-type sesquiterpene lactones, mainly alantolactone and isoalantolactone, which have the various pharmacological functions. In this study, we examined the inhibitory effects of nitric oxide (NO) production of hexane, methylene chloride, ethyl acetate, butanol, and water fractions from I. helenium and investigated the anti-inflammatory effect of hexane fraction of I. helenium (HFIH) in LPS-induced RAW 264.7 cells. Quantification of alantolactone and isoalantolactone from HFIH was carried out for the standardization by multiple reaction monitoring using triple quadrupole mass spectrometer. HFIH significantly inhibited inducible NO synthase (iNOS) and cyclooxygenase-2 (COX-2) protein as well as their downstream products NO and prostaglandin $E_2$ ($PGE_2$) in LPS-stimulated RAW 264.7 cells. Moreover, HFIH suppressed $NF-{\kappa}B$ transcriptional activity by decreasing the translocation of p65 to the nucleus. The in vivo study further confirmed that HFIH attenuated the paw edema induced by carrageenan in an acute inflammation model. These findings suggest that HFIH may be useful as a promising phytomedicine for inflammatory-associated diseases.

In-situ Process Monitoring Data from 30-Paired Oxide-Nitride Dielectric Stack Deposition for 3D-NAND Memory Fabrication

  • Min Ho Kim;Hyun Ken Park;Sang Jeen Hong
    • Journal of the Semiconductor & Display Technology
    • /
    • v.22 no.4
    • /
    • pp.53-58
    • /
    • 2023
  • The storage capacity of 3D-NAND flash memory has been enhanced by the multi-layer dielectrics. The deposition process has become more challenging due to the tight process margin and the demand for accurate process control. To reduce product costs and ensure successful processes, process diagnosis techniques incorporating artificial intelligence (AI) have been adopted in semiconductor manufacturing. Recently there is a growing interest in process diagnosis, and numerous studies have been conducted in this field. For higher model accuracy, various process and sensor data are required, such as optical emission spectroscopy (OES), quadrupole mass spectrometer (QMS), and equipment control state. Among them, OES is usually used for plasma diagnostic. However, OES data can be distorted by viewport contamination, leading to misunderstandings in plasma diagnosis. This issue is particularly emphasized in multi-dielectric deposition processes, such as oxide and nitride (ON) stack. Thus, it is crucial to understand the potential misunderstandings related to OES data distortion due to viewport contamination. This paper explores the potential for misunderstanding OES data due to data distortion in the ON stack process. It suggests the possibility of excessively evaluating process drift through comparisons with a QMS. This understanding can be utilized to develop diagnostic models and identify the effects of viewport contamination in ON stack processes.

  • PDF

Rapid Determination of Imatinib in Human Plasma by Liquid Chromatography-Tandem Mass Spectrometry: Application to a Pharmacokinetic Study

  • Yang, Jeong Soo;Cho, Eun Gi;Huh, Wooseong;Ko, Jae-Wook;Jung, Jin Ah;Lee, Soo-Youn
    • Bulletin of the Korean Chemical Society
    • /
    • v.34 no.8
    • /
    • pp.2425-2430
    • /
    • 2013
  • A simple, fast and robust analytical method was developed to determine imatinib in human plasma using liquid chromatography-tandem mass spectrometry with electrospray ionization in the positive ion mode. Imatinib and labeled internal standard were extracted from plasma with a simple protein precipitation. The chromatographic separation was performed using an isocratic elution of mobile phase involving 5.0 mM ammonium formate in water-5.0 mM ammonium formate in methanol (30:70, v/v) over 3.0 min on reversed-stationary phase. The detection was performed using a triple-quadrupole tandem mass spectrometer in multiple-reaction monitoring mode. The developed method was validated with lower limit of quantification of 10 ng/mL. The calibration curve was linear over 10-2000 ng/mL ($R^2$ > 0.99). The method validation parameters met the acceptance criteria. The spiked samples and standard solutions were stable under conditions for storage and handling. The reliable method was successfully applied to real sample analyses and thus a pharmacokinetic study in 27 healthy Korean male volunteers.

Quantitative Proteogenomics and the Reconstruction of the Metabolic Pathway in Lactobacillus mucosae LM1

  • Pajarillo, Edward Alain B.;Kim, Sang Hoon;Lee, Ji-Yoon;Valeriano, Valerie Diane V.;Kang, Dae-Kyung
    • Food Science of Animal Resources
    • /
    • v.35 no.5
    • /
    • pp.692-702
    • /
    • 2015
  • Lactobacillus mucosae is a natural resident of the gastrointestinal tract of humans and animals and a potential probiotic bacterium. To understand the global protein expression profile and metabolic features of L. mucosae LM1 in the early stationary phase, the QExactiveTM Hybrid Quadrupole-Orbitrap Mass Spectrometer was used. Characterization of the intracellular proteome identified 842 proteins, accounting for approximately 35% of the 2,404 protein-coding sequences in the complete genome of L. mucosae LM1. Proteome quantification using QExactiveTM Orbitrap MS detected 19 highly abundant proteins (> 1.0% of the intracellular proteome), including CysK (cysteine synthase, 5.41%) and EF-Tu (elongation factor Tu, 4.91%), which are involved in cell survival against environmental stresses. Metabolic pathway annotation of LM1 proteome using the Kyoto Encyclopedia of Genes and Genomes (KEGG) database showed that half of the proteins expressed are important for basic metabolic and biosynthetic processes, and the other half might be structurally important or involved in basic cellular processes. In addition, glycogen biosynthesis was activated in the early stationary phase, which is important for energy storage and maintenance. The proteogenomic data presented in this study provide a suitable reference to understand the protein expression pattern of lactobacilli in standard conditions

Development and validation of LC-MS/MS for bioanalysis of hydroxychloroquine in human whole blood

  • Park, Jung Youl;Song, Hyun Ho;Kwon, Young Ee;Kim, Seo Jin;Jang, Sukil;Joo, Seong Soo
    • Journal of Biomedical and Translational Research
    • /
    • v.19 no.4
    • /
    • pp.130-139
    • /
    • 2018
  • This study aimed to analyze a high-performance liquid chromatography (HPLC) separation using a pentafluorophenyl column of parent drug hydroxychloroquine (HCQ) and its active metabolite, desethylhydroxchloroquine (DHCQ) applying to determine bioequivalence of two different formulations administered to patients. A rapid, simple, sensitive and specific liquid chromatography-tandem mass spectrometry (LC-MS/MS) method has been developed and validated for bioanalysis of HCQ and its metabolite DHCQ in human whole blood using deuterium derivative $hydroxychloroquine-D_4$ as an internal standard (IS). A triple-quadrupole mass spectrometer was operated using electrospray ionization in multiple reaction monitoring (MRM) mode. Sample preparation involves a two-step precipitation of protein techniques. The removed protein blood samples were chromatographed on a pentafluorophenyl (PFP) column ($50mm{\times}4.6mm$, $2.6{\mu}m$) with a mobile phase (ammonium formate solution containing dilute formic acid) in an isocratic mode at a flow rate of 0.45 mL/min. The standard curves were found to be linear in the range of 2 - 500 ng/mL for HCQ; 2 - 2,000 ng/mL for DHCQ in spite of lacking a highly sensitive MS spectrometry system. Results of intra- and inter-day precision and accuracy were within acceptable limits. A run time of 2.2 min for HCQ and 2.03 min for DHCQ in blood sample facilitated the analysis of more than 300 human whole blood samples per day. Taken together, we concluded that the assay developed herein represents a highly qualified technology for the quantification of HCQ in human whole blood for a parallel design bioequivalence study in a healthy male.

Residual Multi Pesticides Screening of Dead Birds by Orbitrap High Resolution Mass Spectrometry (오비트랩 고분해능 질량분석기를 이용한 폐사 조류 중 다성분 잔류 농약 스크리닝 기법)

  • Lee, Doo-Hee;Kim, Bo-Kyong;Wang, Seung-Jun;Son, Ki-Dong;Jung, Hyen-Mi;Choi, Jong-Woo
    • Korean Journal of Environmental Agriculture
    • /
    • v.36 no.4
    • /
    • pp.269-278
    • /
    • 2017
  • BACKGROUND: The objective of this study was to evaluate screening method of residual multi pesticides in dead birds by Orbitrap high resolution mass spectrometry (HRMS) to identify the cause of death for birds. METHODS AND RESULTS: Extraction and clean-up method of residual pesticides in liver of dead birds was used QuEChERS (Quick Easy Cheap Effective Rugged and Safe) and method validations was conducted using liquid chromatography and gas chroamtography with triple-quadrupole mass spectrometer (LC/MS/MS and GC/MS/MS) Also, we were evaluated screening method for the determination of residual pesticides in liver of dead birds by LC and GC Orbitrap Mass Spectrometry. Results of method validations, Correlation coefficients of the matrix matched calibration curves were >0.978, and the method detection limits (MDLs) and limits of quantitation (LOQ) were 2.8~72.1 ng/g (18.4 ng/g on average) and 9.0~230 ng/g (58.5 ng/g on average). The accuracy ranged from 69.1%to 130% (103% on average), and the precision values were less than 14.8%(3.8%on average). The screening of residual pesticides in liver of dead birds by LC and GC Orbitrap HRMS was detected monocrotophos, carbofuran, carbosulfan, deltametrin, benfuracarb, carbofuran, phosphamidon, prochloraz in investigated samples. CONCLUSION: This results showed that accurate mass were extraction of residual pesticides in dead birds by Orbitrap HRMS. It suggested that this screening method is applicable to the residual pesticide analysis for the cause of death as a main tool.

The Effect of Contamination of Ion Source on Ionic Current of Quadrupole Mass Spectrometer (사중극 질량 분석기의 이온소스 오염이 이온전류에 미치는 영향)

  • Lee, K.C.;Park, C.J.;Kim, J.T.;Oh, E.S.;Hong, K.S.;Hong, S.S.;Lim, I.T.;Yun, J.Y.;Kang, S.W.;Shin, Y.H.
    • Journal of the Korean Vacuum Society
    • /
    • v.18 no.3
    • /
    • pp.197-202
    • /
    • 2009
  • The long term stability of ion current of QMS has been one of key parameters for monitoring gas process in vacuum. The time dependence of ionic current was monitored while the pressure of nitrogen gas was kept at a fixed pressure by introducing the gas into vacuum chamber. The chamber was evacuated to ${\sim}3{\times}10^{-9}\;Torr$ to reduce background signals before the measurement. Two ion sources were tested; one had brownish or black color due to gas contamination and the other one was new, i.e. cleaner. At a nitrogen pressure of $1{\times}10^{-5}\;Torr$, the ionic currents measured by the contaminated ion source decreased faster with time. The decrease rate was respectively ${\sim}46%$ for cleaner one and ${\sim}84%$ for contaminated one after ${\sim}5.5%$ hours. In order to test the effect of filament material on the ion current decrease, we fabricated a tungsten(W) filament which consisted of two parts; one half was made of W and the other was coated with yttria. The similar decrease of ionic currents were shown for the two types of filaments, indicating that slight change of temperature of filament due to material difference i.e. baking effect could not improve the origin of ionic current decrease. Overall the decreasing rate of ionic current is more closely associated with contaminated ion source of QMS rather than its filament materials.