• Title/Summary/Keyword: q31.3)

Search Result 369, Processing Time 0.025 seconds

The Nutritive Values in Different Varieties of Corn Planted in One Location Fed to Growing Pigs over Three Consecutive Years

  • Zhang, L.;Li, Y.K.;Li, Z.C.;Li, Q.F.;Lyu, M.B.;Li, D.F.;Lai, C.H.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.29 no.12
    • /
    • pp.1768-1773
    • /
    • 2016
  • This experiment was conducted to determine the effect of variety and planting year on the nutritive values of corn fed to growing pigs. Four corn varieties examined in this experiment were planted in the same village located in Longhua County, Heibei Province, China, in 2012, 2013, and 2014, respectively. During each year, corn was hand-harvested in early October and sun dried to about 14% moisture content. Three batches of twenty-four barrows ($33.27{\pm}4.30$, $31.88{\pm}2.93$, $34.21{\pm}3.81kg$ body wight [BW] in 2012, 2013, and 2014, respectively) were used and allotted to a complete block design with 4 diets and 6 replicate pigs per diet. Pigs were individually placed in metabolic crates. The four experimental diets were formulated by mixing each variety of corn and vitamins and minerals, respectively. A five-day collection period followed a seven-day diet acclimation period. The results indicated that variety of corn significantly influenced the available energy content (digestible energy [DE] on dry matter basis, p<0.05; metabolizable energy (ME) on dry matter basis, p<0.05, respectively), and the apparent total tract digestibility (ATTD) of organic matter (p<0.01), dry matter (p<0.05), gross energy (p<0.05), neutral detergent fiber (p<0.01), acid detergent fiber and ether extract (p<0.05). The planting year also significantly influenced the available energy contents (DE on dry matter basis, p<0.05; ME on dry matter basis, p<0.01, respectively) and the ATTD of neutral detergent fiber (p<0.01), acid detergent fiber (p<0.01), crude protein (p<0.01), and ether extract (p<0.01). No interaction was observed between the variety and planting year in DE and ME contents in corn. In conclusion, the variety and planting year significantly influenced the available energy and nutrient digestibility of corn fed to growing pigs.

농업용수의 수온 상승에 관한 연구

  • Hwang, Eun;Kim, Cheol-Gyu;Lee, Sang-Beom
    • Water for future
    • /
    • v.5 no.2
    • /
    • pp.17-29
    • /
    • 1972
  • The persent study aims at finding out a means of prevention cool spell damages on the hilly areas. The irrigation plots of 24 hour stored water warm water way and warm water plots, cool water way are respectively established to find out water temperature and influnce on the growing rice plants. The results obtained are summed up as follows. 1. Warm water areas consisted of $5 m^2 Q=0.93 1{\ell}/sec$, V=31 cm/sec, S=1/1, 000, L=81.6m, B=5cm, h=6cm, t=4min 33sec, drops=9 areas, are constructed to help the water temperature of $14.5^{\circ}C$ rise to that of $21.6^{\circ}C$. This indicates lower temperature than $23^{\circ}C$ of critical water temperature in irrigation facilities by $1.45^{\circ}C$ and than $26.2^{\circ}C$ of balanced water temperature of Seoul arears by $4.6^{\circ}C$. But this does not give much influance on rice plant cultivation. 2. The rising of water temperature is influened according to the temperature, solar radiation but the water temperature changes according to the heat absorption of organized materials, weather and terraces. The difference of water temperature could be found in the first growing stage. 3. Through the warm water way of water rises to the temperature of $21.6^{\circ}C$ which also rises to the temperature of around $30^{\circ}C$ in the paddy field of submerged irrigation. The rice plants are comparatively free from prolonged cool damage, reproduction abstructive damage. 4. The water temperature in rice field in proportion to temperature influence of weather condition but the water temperature approaches to that of weather in the days of later growing stage and water temperature become lower than the air temperature in the fruit stage. 5. The water in the submreged field is $10^{\circ}C$ warmer than in the warm water way during the first growing stage period but the water temperature in the warm water way is warmer in the later growing stage period. The cool water of $14.5^{\circ}C$ is warmed to $30.1^{\circ}C$ and rice plants cultivation is free from other damages. 6. The 12% increased production or 570.98kg/10a is made cool water plot by rising the temperature of water from $14.5^{\circ}C$ to $21.6^{\circ}C$ making the water run through warm water way. 7. The damage inflicted by the cool water irrigation during the first growing stage period is the obstruction of peak tillering stage and the obstruction of heading the later growing stage period and the obstruction of fruiting and number of panides per fill.

  • PDF

Measurement of thermal expansion characteristic of root canal filling materials : Gutta-percha and Resilon (수 종의 근관충전재의 열팽창 특성 측정 : Gutta-percha와 Resilon)

  • Jeon, Kyung-A;Lee, In-Bog;Bae, Kwang-Shik;Lee, Woo-Cheol;Baek, Seung-Ho
    • Restorative Dentistry and Endodontics
    • /
    • v.31 no.5
    • /
    • pp.344-351
    • /
    • 2006
  • The purpose of this study was to evaluate the thermal expansion characteristics of injectable ther-moplasticized gutta-perchas and a Resilon. The materials investigated are Obtura gutta-percha, Diadent gutta-percha, E&Q Gutta-percha Bar and Epiphany (Resilon). The temperature at the heating chamber orifice of an Obtura II syringe and the extruded gutta-percha from the tip of both 23- and 20-gauge needle was determined using a Digital thermometer. A cylindrical ceramic mold was fabricated for thermal expansion test, which was 27 mm long, with an internal bore diameter of 3 mm and an outer diameter of 10 mm. The mold was filled with each experimental material and barrel ends were closed with two ceramic plunger. The samples in ceramic molds were heated in a dilatometer over the temperature range from $25^{\circ}C$ to $75^{\circ}C$. From the change of specimen length as a function of temperature, the coefficients of thermal expansion were deter-mined. There was no statistical difference between four materials in the thermal expansion in the range from $35^{\circ}C$ to $55^{\circ}C$ (p > 0.05). However, Obtura Gutta-percha showed smaller thermal expansion than Diadent and Metadent ones from $35^{\circ}C$ to $75^{\circ}C$ (p < 0.05). The thermal expansion of Epiphany was similar to those of the other gutta-percha groups.

A Study of well-being in Caregivers Caring for Chronically Ill Family Members (만성 질환자 가족의 부담감에 관한 연구)

  • 서미혜;오가실
    • Journal of Korean Academy of Nursing
    • /
    • v.23 no.3
    • /
    • pp.467-486
    • /
    • 1993
  • Today, more chronically ill and handicapped people are being cared for at home by a family member caregiver. The task of caring for a family momber may mean that the caregiver has less time and money and more work which may result in increased fatigue and symptoms of illness. This study was done to examine the well-being of family caregivers. Fifty three family caregivers were interviewed. Concepts were measured using existing tools and included : Burden(25 item 5 point scale), Social sup-port (21 item 7 point scale), Health status defined by a symptom checklist(48 item S point scale), and Well -being defined by a quality of life scale (14 item 7 point scale) and caregiving activities. Data collection was done by interview and Q-sort. Social support and well - being were positively correlated as were symptoms and burden. Symptoms and burden were negatively correlated with social support and well-being. Items on the quality of life scale had a mean score range from 3.09 to 4.96. Quality of life related to income was lowest (3.09) but the desire to use more money for the patient was rated 2.90 on the burden scale where the item means ranged from 0.73 to 3.55. The high mean of 3.55 was for obligation to give care and the low 0.73 was (or not feeling that this was helping the patient. Mean scores for symptoms ranged from 0.26 to 2.15 with the 2.15 being for “worry about all the things that have to be done.” Over half of the patients were dependent for help with some activities of daily living. The caregivers reported doing an average of 3.40 out of five patient care activities including bathing (77.4%), shampooing (67.9%), and washing face and hands (49.1%), and 3.74 out of seven home maintenance activities including laundry (98.1%), cooking (83.0%), and arranging bed-ding(75.5%). The caregivers reported their spouse as one of the main sources of social support, including in times of loneliness and anger The mean score for loneliness as burden was 2.15 and ranked fourth and 31 (58.5%) of the sample reported being lonely recently and not being satisfied with the support received. Similarly anger caused by the patient was given a mean score of 2.13, and anger was reported to have been present recently by 38 (71.7%) of the sample and satis-faction with the support given was low. Having someone to help deal with anger ranked twelfth out of 21 items on the social support scale and had a mean score of 3.98 (range 3.49 to 5.98). Spouses were reported as a major source of social support but the fact that 50% of the caregivers were caring for a spouse, may account for the quality of this source of social support having been affected. These caregivers faced the same problems as others at the same stage of life. but because of the situation, there was a strain on their resources, particularly financial and social. In conclusion it was found that burden is correlated negatively to quality of life and positively to symptoms, but in this sample, symptoms and bur-den were scored relatively low. Does this indicate that the caregivers accept caregiving as part of their destiny and accept the quality of their lives with burden and symptoms just being a part of caregiving\ulcorner Does the correlation between the bur-den and symptoms indicate they are a measure of the same phenomenon or that the sample was of a more mobile, less burdened group of caregivers\ulcorner Quality of life was the one variable that was significant in explaining the varience on burden. Further study is needed to validate the conclusions found in this study but they indicate a need for nurses to ap-proach these caregivers with a plan tailored to each individual situation and to give consideration to interventions directed at improving quality of life and expanding social support networks for those caring for spouses.

  • PDF

A study of the plan dosimetic evaluation on the rectal cancer treatment (직장암 치료 시 치료계획에 따른 선량평가 연구)

  • Jeong, Hyun Hak;An, Beom Seok;Kim, Dae Il;Lee, Yang Hoon;Lee, Je hee
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.28 no.2
    • /
    • pp.171-178
    • /
    • 2016
  • Purpose : In order to minimize the dose of femoral head as an appropriate treatment plan for rectal cancer radiation therapy, we compare and evaluate the usefulness of 3-field 3D conformal radiation therapy(below 3fCRT), which is a universal treatment method, and 5-field 3D conformal radiation therapy(below 5fCRT), and Volumetric Modulated Arc Therapy (VMAT). Materials and Methods : The 10 cases of rectal cancer that treated with 21EX were enrolled. Those cases were planned by Eclipse(Ver. 10.0.42, Varian, USA), PRO3(Progressive Resolution Optimizer 10.0.28) and AAA(Anisotropic Analytic Algorithm Ver. 10.0.28). 3fCRT and 5fCRT plan has $0^{\circ}$, $270^{\circ}$, $90^{\circ}$ and $0^{\circ}$, $95^{\circ}$, $45^{\circ}$, $315^{\circ}$, $265^{\circ}$ gantry angle, respectively. VMAT plan parameters consisted of 15MV coplanar $360^{\circ}$ 1 arac. Treatment prescription was employed delivering 54Gy to recum in 30 fractions. To minimize the dose difference that shows up randomly on optimizing, VMAT plans were optimized and calculated twice, and normalized to the target V100%=95%. The indexes of evaluation are D of Both femoral head and aceta fossa, total MU, H.I.(Homogeneity index) and C.I.(Conformity index) of the PTV. All VMAT plans were verified by gamma test with portal dosimetry using EPID. Results : D of Rt. femoral head was 53.08 Gy, 50.27 Gy, and 30.92 Gy, respectively, in the order of 3fCRT, 5fCRT, and VMAT treatment plan. Likewise, Lt. Femoral head showed average 53.68 Gy, 51.01 Gy and 29.23 Gy in the same order. D of Rt. aceta fossa was 54.86 Gy, 52.40 Gy, 30.37 Gy, respectively, in the order of 3fCRT, 5fCRT, and VMAT treatment plan. Likewise, Lt. Femoral head showed average 53.68 Gy, 51.01 Gy and 29.23 Gy in the same order. The maximum dose of both femoral head and aceta fossa was higher in the order of 3fCRT, 5fCRT, and VMAT treatment plan. C.I. showed the lowest VMAT treatment plan with an average of 1.64, 1.48, and 0.99 in the order of 3fCRT, 5fCRT, and VMAT treatment plan. There was no significant difference on H.I. of the PTV among three plans. Total MU showed that the VMAT treatment plan used 124.4MU and 299MU more than the 3fCRT and 5fCRT treatment plan, respectively. IMRT verification gamma test results for the VMAT plan passed over 90.0% at 2mm/2%. Conclusion : In rectal cancer treatment, the VMAT plan was shown to be advantageous in most of the evaluation indexes compared to the 3D plan, and the dose of the femoral head was greatly reduced. However, because of practical limitations there may be a case where it is difficult to select a VMAT treatment plan. 5fCRT has the advantage of reducing the dose of the femoral head as compared to the existing 3fCRT, without regard to additional problems. Therefore, not only would it extend survival time but the quality of life in general, if hospitals improved radiation therapy efficiency by selecting the treatment plan in accordance with the hospital's situation.

  • PDF

Anatomical Studies on Root Formation in Hypocotyl and Epicotyl Cuttings of Woody Plants (임목(林木)의 배축(胚軸) 및 유경삽수발근(幼茎揷穗発根)의 해부학적(解剖学的) 연구(研究))

  • Choi, Man Bong
    • Journal of Korean Society of Forest Science
    • /
    • v.52 no.1
    • /
    • pp.1-30
    • /
    • 1981
  • The origin and development of adventitious roots was studied using hypocotyl and epicotyl cuttings of 34 species, 24 genus of woody plants. These cuttings obtained from young seedlings cultured in vials containing distilled water only. The several characteristics of cuttings materials studied are shown in Table 1. The results are summerized as follows: 1. The circumference shapes of cross-sections of hypocotyl and epicotyl cuttings can be divided into six categories, namely, round, irregular round, ellipse, irregular ellipse, square, and triangle. Species differences within a genus did not show any difference of hypocotyl and epicotyl cross-sections shape, however, a noticeable variation among genus or higher taxa. 2. The arrangements of vascular bundles in the cross-sections of hypocotyls or epicotyls were almost all collateral types and generally showed generic characteristics differing one to the other. However, there were some variations between species within the genus. Six models of vascular bundle arrangement were proposed for all the above speices. 3. The rooting portions of hypocotyl and epicotyl cuttings in this experimental materials can be grouped as follows: (1) Interfascicular parenchyma; (Thuja orientalis. T. orientalis for. sieboldii, Acer microsieboldianum, A. palmatum, A. saccharinum, Cercis chinensis, Lespedeza bicolor, Magnolia obovata, M. sieboldii, Mallotus japonicus, Staphylea bumalda) (2) Cambial and phloem parenchyma: (Chamaecyparis obtusa, C. pisifera, Albizzia julibrissin, Buxus microphylla var. Koreana, Cereis chinensis, Euonymus japonica, Firmiana platanifolia, Lagerstroemia indica, Ligustrum salicinum, L. obtusifolium, Magnolia kobus, M. obovata, Mallotus japonicus, Morus alba, Poncirus trifoliata, Quercus myrsinaefolia, Rosa polyantha, Styrax japonica, Styrax obassia) (3) Primary ray tissues; (Euonymus japonica, Styrax japonica) (4) Leaf traces; (Quercus acutissima, Q. aliena) (5) Cortex parenchyma; (Ailanthus altissima) (6) Callus tissues; (Castanea crenata, Quercus aliena, Q. myrsinaefolia, Q. serrata) 4. As a general tendency throughout the species studied, in hypocotyl cuttings, the adventitious root primordia were originated from the interfascicular parenchyma tissue, however, leaf traces and callus tissues were contributed to the root primordia formation in epicotyl cuttings. The hypocotyl cuttings of Ailanthus altissima exhibited a special performance in the root primordia formation, this means that cortex parenchyma was participated to the origin tissue. And in Firmiana platanifolia, differening from the other most species, the root primordia were formed at the phloem parenchyma adjacent outwardly to xylem tissue of vascular bundle system as shown photo. 48. 5. All the easy-to, or difficult-to root species developed adventitious roots in vials filled with distilled water. In the difficult-to-root species, however, root formations seemed to be delayed because they almost all had selerenchyma or phloem fiber which gave some mechanical hindrance to protrusion of root primordia. On the other hand, in the easy-to-root species they seemed to form them more easily because they did not have the said tissues. The rooting portions between easy-to-root and difficult-to-root species have not clearly been distinguished, and they have multitudinous variations. 6. The species structured with the more vascular bundles in number compared with the less vascular bundles exhibited delayed rooting. In the cuttings preparation, the proximal end of cuttings was closer to root-to-stem transition region, the adventitious root formation showed easier. 7. A different case occured however with the mature stem cuttings, in both the needle-leaved and the broad-leaved species. In the hypocotyl cuttings, parenchymatous tissues sited near the vascular bundles become the most frequent root forming portions in general and relevant distinctions between both species were hardly recognizable. 8. In the epicotyl cuttings, root primordia originated mainly in leaf traces in connection with cambial and phloems or callus tissues itself. In the hypocotyl cuttings, interfascicular parenchyma was the most frequent portion of the root primordia formation. The portions of root primordia had more connection with vascular cambium system, as the tissues were continuing to be developed.

  • PDF

Early Changes after Death of Plaice, Paralichthys olivaceus Muscle -2. Temperature Dependency on Physicochemical and Rheological Properties- (넙치(Paralichthys olivaceus)육의 사후 조기 변화 -2. 물리 화학적 및 물성적 특성의 온도 의존성-)

  • CHO Young-Je;KIM Yuck-Yong
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.26 no.1
    • /
    • pp.1-7
    • /
    • 1993
  • To clarify the effect of storage temperature on the physicochemical and rheological properties of plaice, Paralichthys olivaceus muscle, the changes in IMP accumulation rates, rigor index, breaking strength and K-value of muscle during storage at $0^{\circ},\;5^{\circ}C$ and $10^{\circ}C$ were studied. The maximum speed and content of IMP accumulation were showed in sample stored at $0^{\circ}C$ among the all samples. The content and time reached around the maximum IMP accumulation for each samples were $6.94{\mu}mole/g$ and 30hrs for samples stored at $0^{\circ}C,\;6.30{\mu}mole/g$ and 31.5hrs for $5^{\circ}C$ samples and $5.40{\mu}mole/g$ and 45hrs for $10^{\circ}C$ samples, respectively. Values of breaking strength in sample stored at $5^{\circ}C$ increased rapidly than samples at $0^{\circ}C$ showed maximum values after 10hrs. However, In case of fresh flesh stored at $10^{\circ}C$, there was no increase of breaking strength during storage. The breaking strength was not closely related with rigor index. The times reached around $5\%$ K-value which is representative excellent freshness index of sashimi were 14hrs for samples stored at $0^{\circ}C$, 13hrs for $5^{\circ}C$ samples and 4hrs for $10^{\circ}C$ samples. From the results above, it was suggested that the storage at low temperature($10^{\circ}C{\sim}5^{\circ}C$) was effective in increase the IMP contents and breaking strength, and maintenance the high-freshness of fresh plaice flesh at early periods after death.

  • PDF

Diagnostic Performance of HPV E6/E7 mRNA and HPV DNA Assays for the Detection and Screening of Oncogenic Human Papillomavirus Infection among Woman with Cervical Lesions in China

  • Wang, Hye-young;Lee, Dongsup;Park, Sunyoung;Kim, Geehyuk;Kim, Sunghyun;Han, Lin;Yubo, Ren;Li, Yingxue;Park, Kwang Hwa;Lee, Hyeyoung
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.16 no.17
    • /
    • pp.7633-7640
    • /
    • 2015
  • Background: Human papillomavirus (HPV) is the most common sexually transmitted infection worldwide and it is responsible for most cases of cervical uterine cancer. Although HPV infections of the cervix do not always progress to cancer, 90% of cervical cancer cases have been found to be associated with high risk HPV (HR-HPV) infection. HPV DNA testing is widely used, along with Papanicolaou (Pap) testing, to screen for cervical abnormalities. However, there are no data on the prevalence of genotype-specific HPV infections assessed by measuring HPV E6/E7 mRNA in women representative of the Chinese population across a broad age range. Materials and Methods: In the present study, we compared the results with the CervicGen HPV RT-qDx assay, which detects 16 HR-HPV genotypes (Alpha-9: HPV 16, 31, 33, 35, 52, and 58; Alpha-7: HPV 18, 39, 45, 51, 59, and 68; and Alpha-5, 6: HPV 53, 56, 66, and 69), and the REBA HPV-ID assay, which detects 32 HPV genotypes based on the reverse blot hybridization assay (REBA) for the detection of oncogenic HPV infection according to cytological diagnosis. We also investigated the prevalence and genotype distribution of HPV infection with a total of 324 liquid-based cytology samples collected in western Shandong province, East China. Results: The overall HPV prevalences determined by HPV DNA and HPV E6/E7 mRNA assays in this study were 79.9% (259/324) and 55.6% (180/324), respectively. Although the positivity of HPV E6/E7 mRNA expression was significantly lower than HPV DNA positivity, the HPV E6/E7 mRNA assay showed greater specificity than the HPV DNA assay (88.6% vs. 48.1%) in normal cytology samples. The prevalence of Alpha-9 (HPV 16, 31, 33, 35, 52, and 58) HPV infection among these women accounted for up to 80.3% and 76.1% of the high-grade lesions detected in the HPV mRNA and DNA tests, respectively. The HR-HPV genotype distribution, based on HPV DNA and E6/E7 mRNA expression by age group in patients with cytologically confirmed lesions, was highest in women aged 40 to 49 years (35.9% for cytologically confirmed cases, Pearson correlation r value=0.993, p<0.001) for high-grade lesions. Among the oncogenic HR-HPV genotypes for all age groups, there was little difference in the distribution of HPV genotypes between the HPV DNA (HPV -16, 53, 18, 58, and 33) and HPV E6/E7 mRNA (HPV -16, 53, 33, 58, and 18) assays. HPV 16 was the most common HPV genotype among women with high-grade lesions. Conclusions: Our results suggest that the HPV E6/E7 mRNA assay can be a sensitive and specific tool for the screening and investigation of cervical cancer. Furthermore, it may provide useful information regarding the necessity for early cervical cancer screenings and the development of additional effective HPV vaccines, such as one for HPV 53 and 58. Additionally, gaining knowledge of HPV distribution may also inform us about ecological changes in HPV after the vaccination.

Assessment of LCD Color Display Performance Based on AAPM TG 18 Protocol : Decision of Quality Control and Calibration Period (판독용 LCD 컬러 모니터 장치의 성능 평가 - 성능 평가 및 Calibration 주기 결정을 중심으로 -)

  • Lee, Won-Hong;Son, Soon-Yong;Noh, Sung-Soon;Lee, In-Hwa;Kang, Sung-Ho;Lee, Yong-Moon;Park, Jae-Soo;Yoon, Seok-Hwan
    • Journal of radiological science and technology
    • /
    • v.31 no.1
    • /
    • pp.55-60
    • /
    • 2008
  • Purpose: This study is to decide a quality control and calibration period of LCD display devices used for reading diagnostic images. Materias and Methods: The assessment test of 20 flat panel LCD color display devices used for reading diagnostic images were performed based on AAPM TG 18 protocol over the total six sessions at one month intervals from three months after primary calibration, in terms of geometric distortion, reflection test, luminance response evaluation, luminance uniformity, resolution, noise, veiling glare and chromaticity test. Results: The results of geometric distortion, reflection test, luminance uniformity, resolution, noise, veiling glare and chromaticity test were within the criteria recommended by AAPM TG 18, except for luminance response evaluation. In the measured luminance deviation of luminance response evaluation, 4(25%) of 20 display devices were passed a criterion from four months after calibration, and 11 (55%) were passed from eight months. Also in the contrast response of the luminance response evaluation, 1(5%) display device was passed a criterion from four months after calibration, and 3(15%) were passed from eight months. Conclusion: Considering the passing deviation after calibration, the time required and a manpower, the quality control and calibration period of LCD display devices used for reading diagnostic images should be a three months and six months after calibration.

  • PDF

Comparison of Naphthalene Degradation Efficiency and OH Radical Production by the Change of Frequency and Reaction Conditions of Ultrasound (초음파 주파수 및 반응조건 변화에 따른 나프탈렌 분해효율과 OH 라디칼의 발생량 비교)

  • Park, Jong-Sung;Park, So-Young;Oh, Je-Ill;Jeong, Sang-Jo;Lee, Min-Ju;Her, Nam-Guk
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.31 no.2
    • /
    • pp.79-89
    • /
    • 2009
  • Naphthalene is a volatile, hydrophobic, and possibly carcinogenic compound that is known to have a severe detrimental effect to aquatic ecosystem. Our research examined the effects of various operating conditions (temperature, pH, initial concentration, and frequency and type of ultrasound) on the sonochemical degradation of naphthalene and OH radical production. The MDL (Method detection limit) determined by LC/FLD (1200 series, Agilient) using C-18 reversed column is measured up to 0.01 ppm. Naphthalene vapor produced from ultrasound irradiation was detected under 0.05 ppm. Comparison of naphthalene sonodegradion efficiency tested under open and closed reactor cover fell within less than 1% of difference. Increasing the reaction temperature from $15^{\circ}C$ to $40^{\circ}C$ resulted in reduction of naphthalene degradation efficiency ($15^{\circ}C$: 95% ${\rightarrow}$ $40^{\circ}C$: 85%), and altering pH from 12 to 3 increased the effect (pH 12: 84% ${\rightarrow}$pH 3: 95.6%). Pseudo first-order constants ($k_1$) of sonodegradation of naphthalene decreased as initial concentration of naphthalene increased (2.5 ppm: $27.3{\times}10^{-3}\;min^{-3}\;{\rightarrow}$ 10 ppm : $19.3{\times}10^{-3}\;min^{-3}$). Degradation efficiency of 2.5 ppm of naphthalene subjected to 28 kHz of ultrasonic irradiation was found to be 1.46 times as much as when exposed under 132 kHz (132 kHz: 56%, 28 kHz: 82.7%). Additionally, its $k_1$ constant was increased by 2.3 times (132 kHz: $2.4{\times}10^{-3}\;min^{-1}$, 28 kHz: $5.0{\times}10^{-3}\;min^{-1}$). $H_2O_2$ concentration measured 10 minutes after the exposure to 132 kHz of ultrasound, when compared with the measurement under frequency of 28 kHz, was 7.2 times as much. The concentration measured after 90 minutes, however, showed the difference of only 10%. (concentration of $H_2O_2$ under 28 kHz being 1.1 times greater than that under 132 kHz.) The $H_2O_2$ concentration resulting from 2.5 ppm naphthalene after 90 minutes of sonication at 24 kHz and 132 kHz were lower by 0.05 and 0.1 ppm, respectively, than the concentration measured from the irradiated M.Q. water (no naphthalene added.) Degradation efficiency of horn type (24 kHz) and bath type (28 kHz) ultrasound was found to be 87% and 82.7%, respectively, and $k_1$ was calculated into $22.8{\times}10^{-3}\;min^{-1}$ and $18.7{\times}10^{-3}\;min^{-1}$ respectively. Using the multi- frequency and mixed type of ultrasound system (28 kHz bath type + 24 kHz horn type) simultaneously resulted in combined efficiency of 88.1%, while $H_2O_2$ concentration increased 3.5 times (28 kHz + 24 kHz: 2.37 ppm, 24 kHz: 0.7 ppm.) Therefore, the multi-frequency and mixed type of ultrasound system procedure might be most effectively used for removing the substances that are easily oxidized by the OH radical.