• Title/Summary/Keyword: pv module

검색결과 599건 처리시간 0.035초

Sliding Mode Controller Applied to Coupled Inductor Dual Boost Inverters

  • Fang, Yu;Cao, Songyin;Wheeler, Pat
    • Journal of Power Electronics
    • /
    • 제19권6호
    • /
    • pp.1403-1412
    • /
    • 2019
  • A coupled inductor-dual boost-inverter (CIDBI) with a differential structure has been presented for application to a micro-inverter photovoltaic module system due to its turn ratio of a high-voltage level. However, it is difficult to design a CIDBI converter with a conventional PI regulator to be stable and achieve good dynamic performance, given the fact that it is a high order system. In view of this situation, a sliding mode control (SMC) strategy is introduced in this paper, and two different sliding mode controllers (SMCs) are proposed and adopted in the left and right side of two Boost sub-circuits to implement the corresponding regulation of the voltage and current. The schemes of the SMCs have been elaborated in this paper including the establishment of a system variable structure model, selection of the sliding surface, determination of the control law, and presentation of the reaching conditions and sliding domain. Finally, the mathematic analysis and the proposed SMC are verified by experimental results.

MNPC IGBT 모듈을 적용한 3상 25kW급 태양광 인버터 개발 (Development of 3-Phase 25kW PV Inverter using MNPC IGBT Module)

  • 김명기;한석규;노용수;김진홍;최준혁
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2019년도 전력전자학술대회
    • /
    • pp.277-278
    • /
    • 2019
  • 본 논문은 기존 2레벨 인버터와 비교하여 고전압에서 고효율과 절반의 전류리플을 가지는 MNPC 모듈을 적용한 태양광 인버터 개발 내용에 대해 서술한다. 개발한 MNPC 모듈을 적용한 태양광 인버터의 입력 전압 사양은 600~1000V이며, 출력은 3상 380V, 25kW로 설계하였다. 설계된 인버터의 성능은 PSIM 시뮬레이션을 통해 검증하였다.

  • PDF

태양광 PCS 개발을 통한 MNPC 타입의 전력반도체 모듈 성능 비교 (A Comparative Analysis on Performance of MNPC Power Semiconductor Module through PV-PCS Development)

  • 김채린;이기철;노용수;현병조;박준성
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2020년도 전력전자학술대회
    • /
    • pp.302-303
    • /
    • 2020
  • 본 논문은 모듈 평가를 위한 태양광 PCS 개발과 이에 적용되는 모듈 성능 비교에 대해 다룬다. 개발되는 인버터는 3상 380V, 26.5kW 급으로 MNPC 타입의 전력반도체 모듈을 적용한다. 전력반도체 모듈 국내 개발품과 해외 선진사 제품(Vincotech사)의 성능비교를 위해 데이터시트를 기반으로 손실 분석을 수행하였다. 그리고 이를 검증하기 위해 개발된 전력모듈을 평가용 인버터에 적용하여 부하별 효율 비교 평가를 진행하였다.

  • PDF

성형용 코어면 DLC 코팅에 의한 비구면 Glass렌즈 광학적 특성에 관한 연구 (Optical Properties of Aspheric Glass Lens using DLC Coated Molding Core)

  • 김현욱;차두환;이동길;김상석;김혜정;김정호;정상화
    • 한국광학회지
    • /
    • 제18권5호
    • /
    • pp.362-366
    • /
    • 2007
  • 본 연구에서는 3 메가픽셀, 2.5배 줌 카메라폰 모듈용 비구면 유리렌즈 개발을 목적으로 실험계획법(DOE)을 적용하여 성형용 초경 코어의 연삭가공조건을 구하고, 이를 활용하여 비구면 Glass렌즈 성형용 초경합금(WC) 코어를 초정밀 연삭가공을 수행하였다. 또한 가공된 성형용 코어의 가공면 위에 이온증착법으로 다이아몬드상 탄소(Diamond-Like Carbon; DLC) 코팅을 수행하여 DLC 코팅이 성형용 코어의 형상정도(PV)와 표면조도(Ra)에 미치는 영향을 평가하였으며, 비구면 Glass렌즈를 동일한 조건에서 성형하여 성형렌즈의 광학적 특성을 비교하여 성형용 코어면의 DLC 코팅 효과에 대하여 검토하였다.

실측데이터를 이용한 에너지제로주택의 연간 에너지성능평가 (Annual Energy Performance Evaluation of Zero Energy House Using Metering Data)

  • 임희원;윤종호;신우철
    • KIEAE Journal
    • /
    • 제16권3호
    • /
    • pp.113-119
    • /
    • 2016
  • Purpose: In this study, we evaluate the annual energy performance of the detached house which was designed with the aim of zero energy. Method: The experimental house which was constructed in Gonju Chungnam in 2013, is the single family detached house of light weight wood frame with $100m^2$ of heating area. Thermal transmittance of roof (by ISO 10211) and building external walls are designed as $0.10W/m^2K$ and $0.14W/m^2$ respectively and low-e coating vacuum window glazing with PVC frame was installed. Also grid connected PV system and natural-circulation solar water heater was applied and 6kWp capacity of photovoltaic module was installed in pitched roof and $5m^2$ of solar collector in vertical wall facing the south. We analyzed the 2014 annual data of the detached house in which residents were actually living, measured though web-based remote monitoring system. Result: First, as a result, total annual energy consumption and energy production (PV generation and solar hot water) are 7,919kWh and 7,689kWh respectively and the rate of energy independence is 97.1% which is almost close to the zero energy. Second, plug load and hot water of energy consumption by category showed the highest numbers each with 33% and 31%, with following space heating 24%, electric cooker 8%, lighting 3% in order. Hot water supply is relatively higher than space heating because high insulation makes it decreased.

Genotypic Variation in Leaf Water Status of Soybean

  • Jin, Yong-Moon;Lee, Hong-Suk;Lee, Suk-Ha;Kwon, Yong-Woong;Im, Jeong-Nam
    • 한국작물학회지
    • /
    • 제44권1호
    • /
    • pp.55-58
    • /
    • 1999
  • Plant water status during growth is directly and indirectly associated with seed yield. The objective of the present study was to determine the genotypic differences in leaf water characteristics at an early growth stage of soybean [Glycine max (L.) Merrill] plants through the pressure-bomb technique. Measurements of water potential as well as relative water content (RWC) were made at the third leaf from the fully-expanded top leaf of eight different soybean genotypes grown for 31 to 35 days after field emergence. On the basis of the modified exponential model, pressure-volume (PV) curves were fitted well ($R^2$=0.92** to 0.99** for the curvi-linear region and R=0.67** to 0.96** for the linear region), indicating that a segmented model using PROC NLIN of SAS could be used effectively to estimate the leaf water characteristics. The regression analysis for the pressure-volume (PV) curve revealed genotypic variation in the solute potential at saturation (Ψ$_{s,sat}$ :-10.7 to -14.8 bar), solute potential at incipient plasmolysis (Ψ$_{s,ip}$ : -14.3 to -18.3 bar), RWC at incipient plasmolysis (RW $C_{ip}$ : 83.3 to 91.7%), high integrated turgor pressure from saturation to plasmolysis ( $_1$$^{b}$ : 0.39 to 0.81), and maximum volumetric modulus of elasticity ($\varepsilon$$_{max}$ : 150 to 445 bar).).

  • PDF

한국 산업용 건물지붕 적용 PV에 의한 발전량 및 CO2 분석연구 (A Study on Electric Capacity and CO2 by the Roof Top PV System of the Industrial Building in Korea)

  • 김지수;이응직;황정하
    • 한국태양에너지학회 논문집
    • /
    • 제30권6호
    • /
    • pp.131-136
    • /
    • 2010
  • The purpose of this study is to provide foundational data for expansion of solar generation in building application, a clean energy, by introducing applicability of solar power generation system on roofs of industrial buildings and computing expected amounts of power and carbon dioxides reduction. As methodologies of this study, after reviewing 120,000 domestic factories to verify the BIPV feasibility for industrial building sthrough theoretical considerations of solar generation system, we calculated BIPV application methods and subsequent expected power generation quantity and carbon dioxide reductions through roof type analysis. we analyzed four cases of expected power generation amounts of solar batteries according to application methods, and when considering that the main type of roofs are slant roofs according to the investigation result about roof forms of domestic industrial complexes, we believe that the module angle of a slant roof around $17^{\circ}$(case3) is most suitable for the application. Finally, we came up with 517,944[TOE] as the corresponding petroleum tonnage based on this computed expected power generation amount and the amount of 1,214,836[$tCO_2$] carbon dioxide reductions by calculating them by energy sources.

인조잔디 바닥종류에 따른 양면수광형 실리콘 태양광 모듈의 발전성능 평가 (Evaluation of Power Generation Performance for Bifacial Si Photovoltaic Modules installed on Different Artificial Grass Floors)

  • 유영균;서영주;박도현;김민수;장호준;권영훈;황보철;김우경;장성호
    • 에너지공학
    • /
    • 제27권3호
    • /
    • pp.1-9
    • /
    • 2018
  • 본 연구에서는 양면수광형 태양광 발전시스템의 바닥면 적용을 목적으로 개발된 고반사율 인조잔디를 적용하여 태양광 모듈의 발전성능 옥외실증평가를 실시하였다. 사용된 모듈은 60셀 규격의 단면수광형 모듈과 2종의 양면수광형 모듈이며, 양면수광형 모듈들은 각각 split-type과 일반 box-type의 정션박스가 부착된 모델이다. 평가결과 양면모듈의 split-type 정션박스가 일반 box-type 정션박스 대비 후면출력개선에 크게 도움이 되었고, 이는 energy yield 향상으로 이어졌다. 양면수광형 모듈은 단면모듈 대비 일반 시멘트 바닥면에서는 평균적으로 28-29%, 인조잔디 바닥면에서는 29-33% 정도의 발전량 향상 (bifacial gain)을 보였다. 인조잔디의 경우 반사율을 높힌 시편의 경우 반사율(Albedo)이 0.18로 기존의 단모 및 장모의 반사율 0.14-0.15 보다 우수한 것으로 평가되었고, 이는 bifacial gain의 기존 29-30% 수준에서 33%로의 개선을 달성하였다.

제로에너지 건축물 확산을 위한 건물 일체형 태양광 적용방안 연구 (A Study on the Application of BIPV for the Spread of Zero Energy Building)

  • 박승준;전현우;이승준;오충현
    • 디지털융복합연구
    • /
    • 제19권9호
    • /
    • pp.189-199
    • /
    • 2021
  • 국내 제로에너지건축물 의무화를 대응하기 위해서 신재생에너지 자립률을 높이려면 고층 건물일수록 대지면적에 한계가 있고 옥상에 PV모듈을 설치하는 것만으로는 부족하다. 따라서 제로에너지건축물을 실현할 수 있는 핵심 에너지원으로 BIPV(Building Integrated PhotoVoltaic, 이하 BIPV)는 가장 주목받는 산업이다. 이에 본 연구는 BIPV 산업의 올바른 방향 제시와 활성화룰 위해 설계자, 시공자, 제품 제조자, 유지관리자 등 경력 10년 이상 전문가를 대상으로 BIPV 산업의 문제점을 자율 토론 방식으로 설문 조사를 시행하였다. BIPV 적용의 산업적 문제점으로는 제품 인증을 위한 표준 및 인증기준의 범위 확대, 다품종 소량 생산의 현황을 고려한 인증범위 개선, 컬러 모듈과 루버 모듈 및 지붕형 제품을 수용할 수 있는 표준 개정 필요성, 인증제품 의무화를 통한 외산 모듈의 국내 유입 차단의 필요성, BIPV 제품 정보 획득의 어려움, BIPV의 건축 적용 부위 등에 대한 정확한 가이드라인으로 참여자간의 혼란 야기 방지 필요, BIPV 정의의 명확한 정립과 지원 정책이나 제도가 부족하다는 문제들을 도출하였다. 이에 본 연구는 산업계에서 바라보는 시장 변화와 영향을 주고 있는 요소, 경쟁력 강화를 위한 필요한 개선 사항을 바탕으로 대응 방안과 방향성을 제시하고 제안하는데 그 목적이 있다.

One sensor방식의 추적식 PV System (The Tracking Photovoltaic System by One sensor Type)

  • 고재홍;박정민
    • 한국산학기술학회논문지
    • /
    • 제13권10호
    • /
    • pp.4733-4739
    • /
    • 2012
  • 본 논문에서는 태양과 태양전지 모듈이 법선을 이루도록 기존에 태양의 방위각 및 고도각을 제어하는 양축 추적시스템에 2개의 센서를 사용하였던 Double-sensor방식에서 1개의 센서로 방위각 및 고도각을 제어할 수 있는 One-sensor방식의 양축 추적시스템을 제안하였다. 그리고 제안한 추적시스템을 제작하여 시스템의 실제 운전을 실행하였다. 제안한 추적시스템은 1개의 센서를 이용하여 태양이 항상 법선을 이루면서 태양전지 모듈에 입사되게 제어하기 위해 방위각과 고도각을 제어하는 양축 추적시스템이다. 실험결과 가장 효율적인 운전과 불필요한 구동부의 동작을 방지하여 전력소모를 감소할 수 있었으며 고정식에 비해 본 논문에서 제안한 One-sensor방식의 양축 추적시스템이 약 23[%]의 발전효율이 증가함을 확인 할 수 있었다. 태양을 추적하여 더 많은 햇빛을 받게 하여 태양전지의 효율을 높이기 위하여 행해진 추적장치는 대형 방식에 많은 연구가 진행되어 왔다. 따라서 본 논문의 태양위치추적의 모니터링 시스템을 구축하여 지속적인 발전효율에 대한 실용화 연구를 통해 태양광발전시스템 보급에 큰 역할을 할 것이라 기대된다.