• Title/Summary/Keyword: pv module

검색결과 599건 처리시간 0.024초

적외선 램프 가열방식을 이용한 태양전지 셀의 솔더링 공정 및 열처리 조건 별 특성 평가 (Characterization of Soldering Property on Heating Condition by Infrared Lamp Soldering Process for C-Si Photovoltaic Modules)

  • 손형진;이정진;김성현
    • Current Photovoltaic Research
    • /
    • 제4권2호
    • /
    • pp.59-63
    • /
    • 2016
  • A key point of a soldering process for photovoltaic (PV) modules is to increase an adhesive strength leading a low resistivity between ribbon and cell. In this study, we intended to optimize a heating condition for the soldering process and characterize the soldered joint via physical and chemical analysis methods. For the purpose, the heating conditions were adjusted by IR lamp power, heating time and hot plate temperature for preheating a cell. Since then the peel test for the ribbon and cell was conducted, consequently the peel strength data shows that there is some optimum soldering condition. In here, we observed that the peel strength was modified by increasing the heating condition. Such a soldering property is affected by a various factors of which the soldered joint, flux and bus bar of the cell are changed on the heating condition. Therefore, we tried to reveal causes determining the soldering property through analyzing the soldered interface.

III-V 화합물 반도체를 이용한 고효율 집광형 태양광 발전시스템 설계 및 성능분석 (Designed and Performance Analysis of High Efficiency Concentrated Photovoltaic System using III-V Compound Semiconductor)

  • 고재홍
    • 조명전기설비학회논문지
    • /
    • 제26권9호
    • /
    • pp.33-39
    • /
    • 2012
  • For photovoltaic power generation need certainly decreasing module's price and increasing promote efficiency technology. Almost of solar panel is on the decrease energy efficiency since 2,000. like silicone(Si) solar panel, thin film solar panel and etc. Silicone(Si) solar panel was best efficiency in 1999. It's 24%. But after that time, It didn't pass limit of energy efficiency. That's why, nowadays being issued that using III-V compound semiconductor to high efficiency of concentrating photovoltaic system for making an alternative proposal. In Korea, making researches in allied technology with III-V compound semiconductor solar panel, condenser technology, and solar tracker. but feasibility study for concentrating photovoltaic power generation hasn't progressed yet. This thesis made a plan about CPV(Concentrating Photovoltaic)system and CPV has a higher energy efficiency than PV(Photovoltaic)system in fine climate conditions from comparing CPV with using silicone(Si) solar panel to PV's efficiency test result.

열충격 시험을 통한 태양전지 특성 (Characteristics of Solar Cell by Thermal Shock test)

  • 강민수;전유재;손선익;김도석;신영의
    • 한국태양에너지학회:학술대회논문집
    • /
    • 한국태양에너지학회 2012년도 춘계학술발표대회 논문집
    • /
    • pp.91-95
    • /
    • 2012
  • 본 연구에서는 열충격 시험을 통하여 Cell레벨에서의 효율저하 특성을 분석하였다. 열충격 시험은 PV모듈의 시험 규격인 KS C IEC-61215를 이용하여 보다 가혹한 조건인 $-40^{\circ}C$에서 $120^{\circ}C$의 조건으로 500사이클 수행하였다. I-V 측정을 통하여 효율을 분석한 결과, 열충격 시험 전 13.9%에서 열충격 시험 후 11.0%로 효율이 저하 됐으며, 감소율은 20.9% 나타났다.EL촬영을 통해 표면을 분석한 결과 Ribbon접합부 및 Gridfinger의 손상으로 확인 됐으며, 보다 정확한 효율 저하의 원인을 분석하기 위해 단면분석을 실시한 결과 표면손상으로 확인 되었던 위치의 Cell내부에서도 Crack을 확인 할 수 있었다. 또한 FF값을 분석한 결과 열충격 시험 전 72.3%에서 시험 후 62.0%로 11.8%의 감소율을 보였다. 따라서, 경년 시 나타나는 효율저하는 Cell자체의 소모전력 증가와 외부환경에 의한 표면 손상 및 Cell내부의 Crack에 기인하여 가속된다고 판단된다.

  • PDF

Analysis and Design of a Three-port Flyback Inverter using an Active Power Decoupling Method to Minimize Input Capacitance

  • Kim, Jun-Gu;Kim, Kyu-Dong;Noh, Yong-Su;Jung, Yong-Chae;Won, Chung-Yuen
    • Journal of Power Electronics
    • /
    • 제13권4호
    • /
    • pp.558-568
    • /
    • 2013
  • In this paper, a new decoupling technique for a flyback inverter using an active power decoupling circuit with auxiliary winding and a novel switching pattern is proposed. The conventional passive power decoupling method is applied to control Maximum Power Point Tracking (MPPT) efficiently by attenuating double frequency power pulsation on the photovoltaic (PV) side. In this case, decoupling capacitor for a flyback inverter is essentially required large electrolytic capacitor of milli-farads. However using the electrolytic capacitor have problems of bulky size and short life-span. Because this electrolytic capacitor is strongly concerned with the life-span of an AC module system, an active power decoupling circuit to minimize input capacitance is needed. In the proposed topology, auxiliary winding defined as a Ripple port will partially cover difference between a PV power and an AC Power. Since input capacitor and auxiliary capacitor is reduced by Ripple port, it can be replaced by a film capacitor. To perform the operation of charging/discharging decoupling capacitor $C_x$, a novel switching sequence is also proposed. The proposed topology is verified by design analysis, simulation and experimental results.

전도성 접착제 물성에 따른 슁글드 어레이 태양전지 특성 평가 (Characterization of Electrically Conductive Adhesives for Shingled Array Photovoltaic Cells)

  • 지홍섭;최원용;이재형;정채환
    • Current Photovoltaic Research
    • /
    • 제5권3호
    • /
    • pp.95-99
    • /
    • 2017
  • The interconnecting shingled solar cells method shows extremely high ratio active area per total area and has the excellent potential for high power PV (photovoltaic). Compared to the conventional module, it can have much more active area due to busbar-free structure. The properties of ECA (electrically conductive adhesives) are significant to fabricate the shingled array PV since it should be used in terms of electric and structural connection. Various ECA were tried and characterized to optimize the soldiering conditions. The open circuit voltage of shingled array cells showed a three-fold increase and efficiency was also increased by 1.63%. The shingled array cells used in CE3103WLV showed the highest power and in CA3556HF the lowest curing temperature and very fast curing time.

그림자 영향과 태양광 어레이 구조에 따른 최대발생전력 비교 해석 및 실험 (Comparison of maximum generated power by shading effect and PV array configurations)

  • 김의종;유병규;차한주;유권종
    • 한국태양에너지학회 논문집
    • /
    • 제29권2호
    • /
    • pp.8-13
    • /
    • 2009
  • In this paper, two configurations of PV array are analyzed and tested under shading condition, where two configurations are series-parallel and total-crass-tied configuration. Each photovoltaic module is emulated by two 5 inch po1y-crystalline cells in series and an array is constructed by connecting 24 of the modules to compare a generated maximum power of the two configurations. Pspice and Sun simulator. PASAN IIIb, are used for simulation and experiment to test the array under various partial shading conditions. Test results show the total-cross-tied configuration generates 7.63% higher maximum power than the series-parallel configuration, and it is well matched to the analysis and simulations of the two configurations.

MPPT 및 CCVC 알고리즘을 적용한 에너지 절약형 OF-LED 광고조명시스템 (Energy Saving Type OF-LED Illuminated Display Board System with MPPT and CCVC Algorithms)

  • 이성룡;전칠환;이수원;이은철
    • 조명전기설비학회논문지
    • /
    • 제19권2호
    • /
    • pp.1-6
    • /
    • 2005
  • 본 연구에서는 광고 조명으로 인한 에너지 소비를 극소화하기 위하여 OF-LED(Optical-Fiber LED)를 이용한 에너지 절약형 광고 조명 시스템에 대하여 연구하였다. 제안한 OF-LED광고 조명 시스템은 에너지 소비가 획기적으로 저감되고 시스템의 소형화가 가능하며, 부조일이 높은 장마철을 제외하고는 태양광 발전만으로 운영하는 큰 장점을 가진다. 태양전지의 출력 특성에 의한 배터리의 최단$\cdot$최적 충전을 위해 정전류$\cdot$정전압 제어법(CCVC)과, IncCond알고리즘을 병행하여 적용하였다 그리고 원칩 마이크로프로세서로 디스플레이 제어와 충 방전제어를 동시에 수행하도록 하였다. 이를 실험을 통하여 제시된 시스템의 유용성을 입증하였다.

반사판을 이용한 고정식 집속형 태양광.열복합패널의 성능평가 (Performance Evaluation of Fixed-concentrated Photovoltaic/Thermal Hybrid Panel using Reflector)

  • 서유진;허창수
    • 한국태양에너지학회 논문집
    • /
    • 제25권4호
    • /
    • pp.85-92
    • /
    • 2005
  • One of the most effective methods for utilizing solar energy is to combine thermal solar and optical energy simultaneously using a hybrid panel. Many systems using various kinds of photovoltaic panels have already been constructed. But utilizing solar energy by means of a hybrid panel with concentrator has not been to be attempted yet. Normally if sunlight is directed on the solar cell, and there is no increase in temperature, the absorption energy of each cell will increase per unit area. In a silicon solar cell. however, cell conversion efficiency decreases according to the increasing temperature. Therefore, to maintain cell conversion efficiency under normal condition, it is necessary to keep the cell at operating temperature. we design and make new hybrid panel with cooling system to prevent increasing of temperature on cell, collect effectively thermal energy. We compared performance of new hybrid panel with PV module and thermal panel. We also evaluated conversion efficiency, electric power and thermal capacity and confirmed cooling effect from thermal absorption efficiency.

태양광 발전시스템의 MPPT 알고리즘 분석 (Analysis of various MPPT algorithms for PCS)

  • 심재휘;양승대;정승환;최주엽;최익;안진웅;이동하
    • 한국태양에너지학회 논문집
    • /
    • 제31권2호
    • /
    • pp.16-21
    • /
    • 2011
  • Since the maximum power operating point(MPOP) of PCS alters with changing atmospheric conditions temperature conditions shadow conditions it is important to operate for PCS to keep maximum power point tracking(MPPT) continuously. This paper presents the results of modeling PV system by PSIM simulator and investigates the influence on the PV system from aspect of power quality i.e. voltage drop. This paper investigates four MPPT algorithms; Perturbation & Observation(P&O) Improved P&O Incremental Conductance(Incond) Differential coefficient method simulated with irradiation temperature change and shadow conditions.

건물일체형 태양광발전 시스템의 발전성능 분석 (A Study on generation characteristics of building integrated Photovoltaic system)

  • 박재완;신우철;김대곤;윤종호
    • 한국태양에너지학회 논문집
    • /
    • 제33권3호
    • /
    • pp.75-81
    • /
    • 2013
  • In this study, we analyze the performance characteristics of Building Integrated Photovoltaic (BIPV) system of K Research Building which was designed with the aim of zero carbon building. In addition, BIPV system, which is consist of three modules; G to G(Glass to Glass), G to T(Glass to Tedlar/Crystal) and Amorphous, has 116.2kWp of total capacity, and is applied to wall, window, atrium and pagora on roof. Therefore, in this paper, our research team analyzed BIPV yield and generation characteristic. BIPV yield was 112,589kWh a year from January 2012 to December 2012. And after applying PV panels on the building, the power from the best setting angle, $30^{\circ}$, of panel was compared. In addition, when the PV was attached practically on the building, the generation power was analyzed. BIPV modules in this study the relationship between module setting angle, type of modules ect. and power characteristics plans to identify.