광 포획 태양전지 모듈 커버용 유리기판 기술 현황 (Current status of light trapping in module cover glass for PV module)

  • 박형식;정재성;신명훈;김선보;이준신
    • Current Photovoltaic Research
    • /
    • 제4권3호
    • /
    • pp.119-123
    • /
    • 2016
  • We discussed various cover glass substrates available for photovoltaic (PV) modules, and investigated the fabrication methods of light trapping structures for the efficiency enhancement of PV modules: wet and dry etching or laser and direct patternings. We also introduced the analysis of haze at etched glass surfaces as a function of wavelength and also presented a anti-reflection coating technology for PV module.

태양전지모듈의 노화현상에 따른 전기적 특성 고찰 (Consideration of Electrical Properties in Field-aged Photovoltaic Module)

  • 강기환;유권종;안형근;한득영
    • 한국전기전자재료학회논문지
    • /
    • 제17권12호
    • /
    • pp.1289-1295
    • /
    • 2004
  • In this paper, degradation in field-aged PV modules including degradation of interconnect, discoloration of encapsulant and hot spot have been observed and analyzed. From the results, photovoltaic module installed for 6 years shows around 16 % drop of electrical properties due to the interconnect degradation and PV module passed 18 years has been found to drop of around 20 % mainly by the encapsulant discoloration. Furthermore the difference between low and high temperature of PV array at hot spot goes up to 3$0^{\circ}C$ and it leads to interconnect degradation. On the other hands, the temperature difference was observed to be around 15$^{\circ}C$ at the encapsulant discoloration spot of PV array.

10kW급 지붕재용 태양전지모듈 실증연구 (Demonstration Study of 10kW Poly Metal Panel integrated PV Module)

  • 이소미;노지희;주만식
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2007년도 추계학술대회 논문집
    • /
    • pp.246-249
    • /
    • 2007
  • The application of photovoltaics into building as integrated building components has been paid more attention worldwide. Photovoltaics or solar electric modules are sol id state devices, directly converting solar radiation into electricity; the process does not require fuel and any moving parts, and produce no pollutants. And the prefab building method is very effective because the pre- manufactured building components is simply assembled to making up buildings in the construction fields especially the sandwich panel. So, this paper describes a design and performance test of the 10kW poly metal pv module(pmpp) system. It is concluded that the prediction of BIPV system's performance should be based on the more accurate PV module installation.

  • PDF

전기적인 특성을 고려한 태양전지모듈의 노화 분석 (Degradation Analysis of PV Module Considering Electrical Characteristics)

  • 김승태;강기환;박지홍;안형근;유권종;한득영
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2008년도 제39회 하계학술대회
    • /
    • pp.1110-1111
    • /
    • 2008
  • The life time of PV module is semi-permanent. But, because of installation and module fabrication process, its important part can not be finished. In this paper, we analyze 15 years old modules made from different company. Among the PV modules, the maximum power drop ratio was 12.23% minimum and 80.63% maximum. Also the effect of solar cell's short circuit current difference was analyzed. The PV module exposed about 65days, its the maximum power drop ratio was 1.29% minimum and 23.43% maximum. It is for reduction of current value. And the reason for current reduction was due to reduction of parallel resistance of solar cell. To prevent early degradation, it is need to have attention to fabrication, installation and maintenance.

  • PDF

PV 모듈에서 셀의 파손에 따른 전기적 출력 특성 비교 (The comparison of maximum output power of PV module by solar cell breakage)

  • 이진섭;강기환;박지홍;유권종;안형근;한득영
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2007년도 하계학술대회 논문집 Vol.8
    • /
    • pp.9-10
    • /
    • 2007
  • In this paper, we investigated the effect of solar cell breakage on maximum output power of PV module. The test result using artificial light source didn't give any change in output power in case of crack near electrical ribbon. Also, there was a reduction in output power in case of increasing of crack area far from electrical ribbon. But, this experiment is under artificial light source test method. So, when such a PV module is outdoor for a long time, there would be problems on electrical output power and durability because of thermal aging phenomenon of solar cell breakage.

  • PDF

Field aged 태양전지모듈의 노화현상에 따른 전기적 특성 관찰 (Observation of Electrical Properties in Field-aged Photovoltaic Module)

  • 강기환;유권종;안형근;한득영
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2004년도 하계학술대회 논문집 Vol.5 No.1
    • /
    • pp.28-32
    • /
    • 2004
  • In this paper, degradation in field-aged PV modules including degradation of interconnect, discoloration of encapsulant and hot spot have been observed and analyzed. From the results, photovoltaic module installed for 6 years shows around 16% drop of electrical properties due to the interconnect degradation and PV module passed 18 years has been found to drop of around 20% mainly by the encapsulant discoloration. Furthermore the difference between low and high temperature of PV array at hot spot goes up to $30^{\circ}C$ and it leads to interconnect degradation. On the other hands, the temperature difference was observed to be around $15^{\circ}C$ at the encapsulant discoloration spot of PV array.

  • PDF

태양광 모듈 통합 전기 자동차용 Phase Shift Full Bridge Converter (A PV-Module Integrated Phase Shift Full Bridge Converter for EV)

  • 황윤경;남광희
    • 전력전자학회논문지
    • /
    • 제25권6호
    • /
    • pp.425-432
    • /
    • 2020
  • The phase-shifted, full-bridge (PSFB) DC-DC converter is widely used in electric vehicles (EVs) to charge a low-voltage (12 V) battery from a high-voltage battery. A Photovoltaic (PV) module-integrated PSFB converter is proposed for the EV power conversion system. The converter is useful because solar energy can be utilized to extend the driving range. The buck converter circuit is simply realized by adding one switch to the conventional PSFB converter's secondary side. For the inductor and diode, the existing components in the PSFB converter are shared. The proposed converter can charge a low-voltage battery from the PV module with maximum power point tracking. In addition, the two power sources can be used simultaneously, and efficiency is increased by reducing the circulating current, which is a problem for the conventional PSFB converter.

The Improvement of Junction Box Within Photovoltaic Power System

  • Sun, Ki-Ju;Cheon, Min-Woo
    • Transactions on Electrical and Electronic Materials
    • /
    • 제17권6호
    • /
    • pp.359-362
    • /
    • 2016
  • In the PV (Photovoltaic) power system, a junction box collects the DC voltage generated from the PV module and transfers it to the PCS (power conditioning system). The junction box prevents damage caused by the voltage difference between the serially connected PV modules and provides convenience while repairing or inspecting the PV array. In addition, the junction box uses the diode to protect modules from the inverse current when the PV power system and electric power system are connected for use. However, by using the reverse blocking diode, heat is generated within the junction box while generating electric power, which decreases the generating efficiency, and causes short circuit and electric leakage. In this research, based on the purpose of improving the performance of the PV module by decreasing the heat generation within the junction box, a junction box with a built-in bypass circuit was designed/manufactured so that a certain capacity of current generated from the PV module does not run through the reverse blocking diode. The manufactured junction box was used to compare the electric power and heating power generated when the circuit was in the bypass/non-bypass modes. It was confirmed that the electric power loss and heat generation indicated a decrease when the circuit was in the bypass mode.

IEC61215을 통한 PV모듈 내구성 평가 및 분석 (Durability Determination and Analysis during IEC61215 PV Module Test)

  • 김경수;강기환;유권종
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2009년도 제40회 하계학술대회
    • /
    • pp.1061_1061
    • /
    • 2009
  • Running low of fossil fuel energy forces the industry to find a new way to overcome this energy crisis. One of the solutions is using the unlimited and everlasting energy sources like wind, sun, water, and so on. Especially, sun energy becomes the hottest issue in recent years because of its merit in installation, operation and abundant material source of silicon. In 2008, about 5.5GW photovoltaic (PV) system has been installed all around world. Many professional renewable energy organizations expect that the total PV system installation will be 30GW. To sustain the long-term stability of the PV system, several institutes perform the test based on IEC standards like IEC 61215 for silicon crystalline PV module and IEC 61646 for thin film PV module. Also in South Korea, Korea Institute of Energy Research (KIER) performs the certificate test according to IEC 61215 standards. In this paper, we want to summarize and inform the 3 years‘ test results of domestic and foreign PV modules. The specific and technical explanation will be shown in the following paper in detail.

  • PDF

후면 환기조건에 따른 건물외피용 태양광발전(BIPV) 모듈의 열적 영향에 관한 실험연구 (Experimental Study on the Thermal Effect of BIPV Modules Depending on the Ventilation Type of PV Module Backside)

  • 윤종호;김재웅
    • 한국태양에너지학회 논문집
    • /
    • 제26권1호
    • /
    • pp.81-89
    • /
    • 2006
  • Building integrated photovoltaic (BIPV) system operates as a multi-functional building construction material. They not only produce electricity, but also are building integral components such as facade, roof, window and shading device. On the other hands lots of architectural considerations should be reflected such as Installation position, shading, temperature effect and so on. As PV modules function like building envelope in BIPV, combined thermal and PV performance should be simultaneously evaluated This study is on the combined thermal and PV performance evaluation of BIPV modules. The purpose of this study is to investigate a temperature effect of PV module depending on the ventilation type of PV module backside. Test cell experiment was performed to identify the thermal and power effect of PV modules. Measurement results on the correlation of temperature and power generation were obtained. Those results can be utilized for the development of optimal BIPV installation details in the very early design stage.