• Title/Summary/Keyword: purpose

Search Result 155,985, Processing Time 0.156 seconds

Radiotherapy in Medically Inoperable Early Stage Non-small Cell Lung Cancer (내과적 문제로 수술이 불가능한 조기 비소세포성 폐암에서의 방사선치료)

  • Kim, Bo-Kyoung;Park, Charn-Il
    • Radiation Oncology Journal
    • /
    • v.18 no.4
    • /
    • pp.257-264
    • /
    • 2000
  • Purpose: For early stage non-small-cell lung cancer, surgical resection is the treatment of choice. But when the patients are not able to tolerate it because of medical problem and when refuse surgery, radiation therapy is considered an acceptable alternative. We report on the treatment results and the effect of achieving local control of primary tumors on survival end points, and analyze factors that may influence survival and local control. Materials and Method : We reviewed the medical records of 32 patients with medically inoperable non-small cell lung cancer treated at our institution from June, 1987 through June, 1997. All patients had a pathologic diagnosis of non-small cell lung cancer and were not candidate for surgical resection because of either patients refusal (4), old age (2), lung problem (21), chest wail invasion (3) and heart problems (3). In 8 patients, there were more than 2 problems. The median age of the patients was 68 years (ranging from 60 to 86 years). Histologic cell type included souamous (24), adenocarcinoma (6) and unclassiried squamous cell (2). The clinical stages of the patients were 71 in 5, 72 in 25, 73 in 2 patients. Initial tumor size was 3.0 cm in 11, between 3.0 cm and 5.0 cm in 13 and more than 5.0 cm in 8 patients. Ail patients had taken chest x-rays, chest CT, abdomen USG and bone scan. Radiotherapy was delivered using 6 MV or 10 MV linear accelerators. The doses of primary tumor were the ranging from 54.0 Gy to 68.8 Gy (median; 61.2 Gy). The duration of treatment was from 37 days through 64 days (median; 0.5 days) and there was no treatment interruption except 1 patient due to poor general status. In 12 patients, concomitant boost technique was used. There were no neoadjuvant or adjuvant treatments such as surgery or chemotherapy. The period of follow-up was ranging from 2 months through 93 months (median; 23 months). Survival was measured from the date radiation therapy was initiated. Results : The overall survival rate was 44.6$\%$ at 2 years and 24.5$\%$ at 5 years, with the median survival time of 23 months. of the 25 deaths, 7 patients died of intercurrent illness, and cause-specific survival rate was 61.0$\%$ at 2 years and 33.5$\%$ at 5 years. The disease-free survival rate was 38.9$\%$ at 2 years and 28.3$\%$ at 5 years. The local-relapse-free survival rate was 35.1$\%$, 28.1$\%$, respectively. On univariate analysis, tumor size was significant variable of overall survival (p=0.0015, 95$\%$ C.1.; 1.4814-5.2815), disease-free survival (P=0.0022, 95$\%$ C.1., 1.4707-5.7780) and local-relapse-free survival (p=0.0015, 95$\%$ C.1., 1.2910- 4.1197). 7 stage was significant variable of overall survival (p=0.0395, 95$\%$ C.1.; 1.1084-55.9112) and had borderline significance on disease-free survival (p=0.0649, 95$\%$ C.1.; 0.8888-50.7123) and local-relapse-free survival (p=0.0582, 95$\%$ C,1.; 0.9342-52.7755). On multivariate analysis, tumor size had borderline significance on overall survival (p=0.6919, 955 C.1., 0.9610-5.1277) and local-relapse-free survival ( p=0.0585, 95$\%$ C.1.; 0.9720-4.9657). Tumor size was also significant variable of disease-free survival (p=0.0317, 95% C.1.; 1.1028-8.4968). Conclusion : Radical radiotherapy is an effective treatment for small (71 or f3 cm) tumors and can be offered as alternative to surgery in elderly or infirmed patients. But when the size of tumor is larger than 5 cm, there were few long-term survivors treated with radiotherapy alone. The use of hypefractionated radiotherapy, endobronchial boost, radisensitizer and conformal or IMRT should be consider to improve the local control rate and disease-specific survival rate.

  • PDF

Concurrent Chemoradiotherapy in Locally Advanced Carcinoma of The Uterine Cervix : A Phase I/II Prospective Study (국소적으로 진행된 자궁경부암의 방사선치료와 복합 항암화학요법의 동시치료 결과)

  • Kang One Chul;Choi Eun Kyung;Chung Weon Kuu;Kim Jong Hoon;Chang Hyesook;Kim Yong Man;Kim Young Tak;Nam Joo Hyun;Mok Jung-Eun;Lee Moo-Song
    • Radiation Oncology Journal
    • /
    • v.16 no.3
    • /
    • pp.311-323
    • /
    • 1998
  • Purpose : Prospective, single arm, Phase I/II clinical trial was performed to assess the efficacy and toxicity of the concurrent chemotherapy and definitive radiotherapy (RT) in patients with previously untreated locally advanced carcinoma of the uterine cervix. Methods and Materials : From Mar 1992 to January 1997, a total of 73 patients with advanced cervical carcinoma were entered on the protocol but 5 patients were excluded in analysis because of patients' refusal of treatment. Their ages ranged from 31 to 77 years, median 58 years. The International Federation of Gynecology and Obstetrics (FIGO) stage distribution was as follows: IIB 46, IIIA 2, IIIB 15 and IVA 5. RT consisted of external beam irradiation to 4,140-5,040 cGy/23-28 fractions plus high dose rate intracavitary treatments to deliver a dose of 30-35 Gy to point A in 6-7 fractions. During the intracavitary treatments parametrial boost was delivered for point B dose of 60 Gy in stage IIB and 65 Gy in stage IIIB. Two cycles of concurrent 5-fluorouracil and cisplatin (FP) chemotherapy (5-fluorouracil 1,000 mg/$m^2$/day continuous infusion for 4 days, day 1-4, 29-32 and cisplatin 20 mg/$m^2$/day intravenous bolus for 3 days day 1-3, 29-31) administered starting on day 1 of RT. Results : The median follow-up was 24 months (range 4-68+). Sixty-four patients were evaluable for survival rate in this protocol: The 5-year actuarial and disease-free survival rate were 52$\%$ and 64$\%$, respectively. The 5-rear actuarial survival for stage IIB and III+IVA patients were 58$\%$ and 36$\%$, respectively The 5-year disease-free survival rate for stage IIB and III+IVA patients were 71$\%$ and 40$\%$, respectively. Of the 68 patients evaluated for patterns of failure, overall recurrence rate was 27.9$\%$ (19/68) : local failure in 5.9$\%$ (4/68), distant metastasis in 10.3$\%$ (7/68) and both in 11.8$\%$ (8/68). Of the 64 patients evaluated for response at one month after the completion of treatment the complete response rate was 78$\%$ (50/64). Concurrent chemoradiation appear to be a well-tolerated regimen but there were two treatment-related deaths. Conclusion : Concurrent chemotherapy of FP with high-dose definitive RT in locally advanced carcinoma of the uterine cervix is feasible and effective with acceptable toxicities. This chemoradiation regimen may offer a modest survival benefit for advanced stage. Further follow-up of these patients will evaluate the impact of this regimen on the long-term local control and their survival.

  • PDF

Analysis of Critical Control Points through Field Assessment of Sanitation Management Practices in Foodservice Establishments (현장실사를 통한 급식유헝별 위생관리실태 분석)

  • Kwak Tong-Kyung;Lee Kyung-Mi;Chang Hye-Ja;Kang Yong-Jae;Hong Wan-Soo;Moon Hye-Kyung
    • Korean journal of food and cookery science
    • /
    • v.21 no.3 s.87
    • /
    • pp.290-300
    • /
    • 2005
  • Increased sanitation management of foodservice establishments is required because most of the reported foodborne-disease outbreaks were in the foodservice industry. The purpose of this study was to determine the important control points for good sanitation. In this study, we inspected twenty foodservice establishments in Seoul, Kyunggi, Kyungnam with a self-developed monitoring tool. These foodservice establishments included secondary schools, universities, and industries. Six of them had appointed as the HACCP-certified establishments from the Korea Food and Drug Administration. The inspection was conducted from June to August in 2002. The inspection tool consisted of nine dimensions and sixty-five items. The dimensions were 'personal sanitation', 'supply of raw food', 'food storage', 'handling of raw food and ready-to-eat', 'cleaning and sterilization', 'waste control', 'pest control', and 'control of establishment and equipment' The highest possible score of this inspection tool is 105 points. Statistical data analysis was completed using the SPSS Package(11.0) for descriptive analysis Kruskal-Wallis. The score for the secondary schools (83.6 points) was higher than for the others and number of in compliance item was 50.9 on average. Therefore, we concluded that the secondary schools' sanitation condition was good. The foodservice establishments acquired HACCP certification was 89.7 points, which was significantly higher than that of establishments not applying foodservices in total score. Instituting the HACCP system in a foodservice is very effective for sanitation management. Many out of the compliance observations were found in the dimensions of 'waste control', 'control of establishment and equipment', and 'supply of raw food' 'Clean condition of refrigerator' item was $65\%$ out of the compliance that was the highest percent in this study. 'Notify and observance of heating/reheating temperature' was $45\%$ out of compliance. Items which were over $30\%$ out of compliance were 'sterilization of knifes and chopping boards in cooking', 'education of workers', 'maintain refrigerator temperature blow $5^{\circ}C$', and 'countermeasure of infection workers' In the results, most of the foodservice establishments were poorly managed in temperature control and cross-contamination. The important control points revealed in this study were preventing contamination, cooking temperature compliance, management of raw food and refrigerator. Therefore foodservice establishments should pay attention to education and training about important control points. The systematic sanitation management monitoring tool developed in this study can be effectively applied for conducting self-inspection and improving the sanitary conditions of their own foodservice operations.

A Study on the Changes of Taste Components in brisket and shank Gom-Kuk by Cooking Conditions (조리조건에 따른 양지머리와 사골곰국의 맛성분 변화에 대한 연구)

  • 조은자;정은정
    • Korean journal of food and cookery science
    • /
    • v.15 no.5
    • /
    • pp.490-499
    • /
    • 1999
  • The purpose of this study was to investigate the changes of taste components in the boiled beef brisket soup stock and shank soup stock by varying pretreatment, boiling temperature and time. Free amino acids and nucleotides color and sensory evaluation in each samples were analyzed. The results were obtained as follows : 1. The amount of free amino acids in the brisket soup stock pretreated by soaking and blanching showed a tendency to increase in proportion to boiling time. The amount of glutamic acid in the brisket soup stock was much in order of soaking > blanching > roasting pretreatment. While the amount of glutamic acid in the boiled soup stock samples pretreated by soaking and blanching was much more at low temperature than at high temperature, the glutamic acid contents in the boiled soup stock pretreated by roasting were large at high temperature. The amount of glutamic acid in pretreated by soaked soup stock showed the highest and recorded 8.73 mg% at 6 hour-low temperature-boiling. 2. The amount of free amino acids in the shank soup stock did not show any regular tendency and had few changes in quantity by the methods of pretreatment. Each amount of glutamic acid in the shank soup stock pretreated by soaking and blanching was the highest, when boiled for 3 hours at high temperature. The samples pretreated by roasting showed the highest record 2.49 mg%, when boiled for 6 hours at high temperature, but could not recognize any regular tendency in the case of boiling at low temperature. 3. The amount of nucleotides in the brisket soup stock generally showed increase in proportion to boiling time. The amount of 5'-IMP extracted from the brisket soup stock was much in order of blanching > soaking > roaking pretreatment, but few differences between blanching and soaking soup stock samples. The amount of 5'-IMP extracted from soup stock samples pretreated by soaking and blanching was high at low-boiling and by roasting at high-boiling. Each amount of 5'-IMP extracted from soup stocks pretreated by soaking(BSL) and blanching(BBL) was the highest at 6 hour-low-boiling(37.06 mg%), and 5 hours(38.37 mg%) respectively. The amount of 5'in the soup stock pretreated by roasting(BRH) showed the highest records at 6 hour-high-boiling(10.85 mg%). 4. The amount of 5'-IMP extracted from the shank soup stock preteated by soaking and blanching showed a tendency to decrease after 3 hours boiling irrelative of boiling temperature. The amount of 5'in the shank soup stock was much in order of soaking > blanching > roasting pretreatment and showed high at the boiling of high temperature. In the sample pretreated by roasting it showed the highst records when boiled for 6 hours at high temperature(1.55 mg%). 5. The L Value of the brisket soup stock pretreared by roasting at high temperature(BRH) was the lowest and the b value of it was the highest of all the brisket samples boiled for 6 hours. No differences were found in the Value of L, a, and b in shank soup stock by the methods of pretreatment and boiling temperature. 6. The sensory scores in color and flavor of the brisket soup stock showd that BRH was higher than the other samples, and the preference in taste and overall was the highest in BSH while it was the lowest in BRH. The preference in the all sensory characteristics of SSH was higher than any other shank soup stock, but did not show any significant difference statistically.

  • PDF

Effect of Nasal Continuous Positive Airway Pressure after Early Surfactant Therapy in Moderate Respiratory Distress Syndrome (중등도 신생아 호흡 곤란 증후군에서 폐 표면 활성제 조기 투여 후 Nasal CPAP의 치료 효과)

  • Kim, Eun Ji;Kim, Hae Sook;Hur, Man Hoe;Lee, Sang Geel
    • Clinical and Experimental Pediatrics
    • /
    • v.45 no.10
    • /
    • pp.1204-1212
    • /
    • 2002
  • Purpose : Early surfactant therapy with either gentle ventilation, high-frequency ventilation or aggressive weaning of mechanical ventilation are principles for the treatment of respiratory distress syndrome(RDS). We studied to determine the accessibility of noninvasive nasal continuous positive airway pressure(CPAP) rather than mechanical ventilation by invasive intubation after early surfactant therapy. Methods : The study group consisted of 14 infants who were born and diagnosed with moderate respiratory distress syndrome and received early surfactant therapy with nasal CPAP of PEEP 5-6 cm $H_2O$ within two hours after birth in the Fatima neonatal intensive care unit for two years from January 1999 to August 2001. The control group consisted of 15 infants who were diagnosed with the disease and could be weaned from mechanical ventilator within five days after birth during the same period. Results : The characteristics, the severity of clinical symptoms and laboratory findings in the two groups at birth showed no significant difference. Neither did the interim analysis of laboratory data in two groups. Of 14 infants in the study group who received nasal CPAP after early surfactant therapy, only two infants showed weaning failure with this therapy. In the response cases, duration of CPAP was five days and mean airway pressure was $5.4{\pm}0.5cm$ $H_2O$. Two had the complication of CPAP with abdominal distension. Final complications and outcomes in the two groups showed no signifcant difference(P>0.05). Conclusion : The clinical courses in the two groups showed no significant difference. Therefore, we suggest that early surfactant therapy with noninvasive nasal CPAP is a simple and safe method rather than aggressive weaning after invasive mechanical ventilation in moderate respiratory distress syndrome.

Evaluating the Efficiency of the Device in Shielding Scattered Radiation during Treatment of Carcinoma of the Penis (음경암의 방사선치료 시 자체 제작한 Device의 산란선 차폐 효과에 대한 유용성 평가)

  • Gim, Yang-Soo;Lee, Sun-Young;Lim, Suk-Gun;Gwak, Geun-Tak;Pak, Ju-Gyeong;Lee, Seung-Hoon;Hwang, Ho-In;Cha, Seok-Yong
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.21 no.1
    • /
    • pp.9-15
    • /
    • 2009
  • Purpose: We evaluated the device that was created for maintaining the patient's setup and protecting the testicles from scattered radiation during treatment of carcinoma of the penis. Materials and Methods: The phantom testicles were made of vaseline cotton gauze and the device consisted of 5 mm of acryl box and 4 mm of lead shielding. $3{\times}3\;cm^2$, $4{\times}4\;cm^2$, $5{\times}5\;cm^2$, $6{\times}6\;cm^2$, $7{\times}7\;cm^2$ field sizes were used for this study and measurement was made at 4, 5, 6, 7, 8, 10 cm from the lower edge of the field for 10 times with lead shielding and without the shielding respectively. 200 cGy was delivered using 6 MV photons. Results: The scatted radiation without lead shielding at 4, 5, 6, 7, 8, 10 cm from the lower edge of the field were 14.8-4.7 cGy with $3{\times}3\;cm^2$, 15.7-5.2 cGy with $4{\times}4\;cm^2$, 17.6-5.5 cGy with $5{\times}5\;cm^2$, 19.9-6.6 cGy with $6{\times}6\;cm^2$, 22.2-7.6 cGy with $7{\times}7\;cm^2$ and the measured dose without lead shielding were 7.1-2.6 cGy with $3{\times}3\;cm^2$, 8.9-3.6 cGy with $4{\times}4\;cm^2$, 12.3-4.8 cGy with $5{\times}5\;cm^2$, 14.6-5.0 cGy with $6{\times}6\;cm^2$ and 21.1~6.4 cGy with $7{\times}7\;cm^2$. As shown above, the scatted radiation decreased after using lead shielding. Depending of the range of field sizes, the resulting difference between without shielding values and with shielding values were: 7.8-1.1 cGy at 4 cm, 5.1-1.2 cGy at 5 cm, 3.8-1.1 cGy at 6 cm, 3.4-1.7 cGy at 7 cm, 2.8-1.7 cGy at 8 cm, 2.4-2.5 cGy at 9 cm and 2.1-1.8 cGy at 10 cm. In the situation as described above, the range in values depending on the distance was 7.8-1.1 cGy with $3{\times}3\;cm^2$, 6.9-1.6 cGy with $4{\times}4\;cm^2$, 5.3-0.8 cGy with $5{\times}5\;cm^2$, 5.3-1.5 cGy with $6{\times}6\;cm^2$ and 1.1-1.8 cGy with $7{\times}7\;cm^2$. Conclusion: Using the device we created to shield the testicles from scattered radiation during treatment of carcinoma of the penis, we have found that scattered radiation to the testicles is decreased by the phantom testicles, and by increasing the distance between the testicles and penis.

  • PDF

USABILITY EVALUATION OF PLANNING MRI ACQUISITION WHEN CT/MRI FUSION OF COMPUTERIZED TREATMENT PLAN (전산화 치료계획의 CT/MRI 영상 융합 시 PLANNING MRI영상 획득의 유용성 평가)

  • Park, Do-Geun;Choe, Byeong-Gi;Kim, Jin-Man;Lee, Dong-Hun;Song, Gi-Won;Park, Yeong-Hwan
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.26 no.1
    • /
    • pp.127-135
    • /
    • 2014
  • Purpose : By taking advantage of each imaging modality, the use of fused CT/MRI image has increased in prostate cancer radiation therapy. However, fusion uncertainty may cause partial target miss or normal organ overdose. In order to complement such limitation, our hospital acquired MRI image (Planning MRI) by setting up patients with the same fixing tool and posture as CT simulation. This study aims to evaluate the usefulness of the Planning MRI through comparing and analyzing the diagnostic MRI image and Planning MRI image. Materials and Methods : This study targeted 10 patients who had been diagnosed with prostate cancer and prescribed nonhormone and definitive RT 70 Gy/28 fx from August 2011 to July 2013. Each patient had both CT and MRI simulations. The MRI images were acquired within one half hour after the CT simulation. The acquired CT/MRI images were fused primarily based on bony structure matching. This study measured the volume of prostate in the images of Planning MRI and diagnostic MRI. The diameters at the craniocaudal, anteroposterior and left-to-right directions from the center of prostate were measured in order to compare changes in the shape of prostate. Results : As a result of comparing the volume of prostate in the images of Planning MRI and diagnostic MRI, they were found to be $25.01cm^3$(range $15.84-34.75cm^3$) and $25.05cm^3$(range $15.28-35.88cm^3$) on average respectively. The diagnostic MRI had an increase of 0.12 % as compared with the Planning MRI. On the planning MRI, there was an increase in the volume by $7.46cm^3$(29 %) at the transition zone directions, and there was a decrease in the volume by $8.52cm^3$(34 %) in the peripheral zone direction. As a result of measuring the diameters at the craniocaudal, anteroposterior and left-to-right directions in the prostate, the Planning MRI was found to have on average 3.82cm, 2.38cm and 4.59cm respectively and the diagnostic MRI was found to have on average 3.37cm, 2.76cm and 4.51cm respectively. All three prostate diameters changed and the change was significant in the Planning MRI. On average, the anteroposterior prostate diameter decrease by 0.38cm(13 %). The mean right-to-left and craniocaudal diameter increased by 0.08cm(1.6 %) and 0.45cm(13 %), respectively. Conclusion : Based on the results of this study, it was found that the total volumes of prostate in the Planning MRI and the diagnostic MRI were not significantly different. However, there was a change in the shape and partial volume of prostate due to the insertion of prostate balloon tube to the rectum. Thus, if the Planning MRI images were used when conducting the fusion of CT/MRI images, it would be possible to include the target in the CTV without a loss as much as the increased volume in the transition zone. Also, it would be possible to reduce the radiation dose delivered to the rectum through separating more clearly the reduction of peripheral zone volume. Therefore, the author of this study believes that acquisition of Planning MRI image should be made to ensure target delineation and localization accuracy.

Compare to Evaluate the Imaging dose of MVCT and CBCT (Tomotherapy MVCT와 Linac CBCT의 Imaging dose 비교평가)

  • Yoon, Bo Reum;Hong, Mi Lan;Ahn, Jong Ho;Song, Ki Won
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.26 no.1
    • /
    • pp.83-89
    • /
    • 2014
  • Purpose : In case of the intensity modulated radiation therapy (IMRT) using Tomotherapy and linear accelerator (Linac), it was to compare and to evaluate the imaging dose of MVCT and CBCT that were performed daily for the correct set up of the patient. Materials and Methods : The human body model Phantom (Anderson rando Phantom, USA) was divided into the three parts as Head, Thorax, pelvis, and after GafChromic EBT3 film cut to the size of $0.5{\times}0.5cm2$.in the center of the recording area were situated on the ant, post, left, and right surface of the phantom and 2cm in depth from the ant, post, left, right, and center surface of the phantom, the surface dose and inner dose were measured repeatedly three times, respectively, using the tomotherapy (Hi Art) and the OBI of NovalisTx. The measured film calculated the output value by RIP version6.0 and then the average value of the dose was calculated by the one-way analysis of variance. Results : Using the human body model phantom, the results of MVCT and CBCT performance were that measurements of MVCT inner dose were showed $15.43cGy{\pm}6.05$ in the head, $16.62cGy{\pm}3.08$ in the thorax, $16.81cGy{\pm}5.24$ in the pelvis, and measurements of CBCT inner dose were showed $13.28{\pm}3.68$ in the head, from $13.66{\pm}4.04$ in the thorax, $15.52{\pm}3.52$ in the pelvis. The measurements of surface dose were showed in case of MVCT performance, $11.64{\pm}4.05$ in the head, $12.16{\pm}4.38$ in the thorax, $12.05{\pm}2.71$ in the pelvis, and in case of CBCT performance, $14.59{\pm}3.51$ in the head, $15.82{\pm}2.89$ in the thorax, $17.48{\pm}2.80$ in the pelvis, respectively. Conclusion : In case of Inner dose, the MVCT using MV energy showed higher than the CBCT using kV energy at 1.16 times in the head, at 1.22 times in the thorax, at 1.08 times in the pelvis, and in case of surface dose, the CBCT was higher than MVCT, at 1.25 times in the head, at 1.30 times in the thorax, at 1.45 times in the pelvis. Imaging dose was a small amount compared to the therapeutic dose but it was thought to affect partially to normal tissue because it was done in daily schedule. However, IMRT treatment was necessarily parallel with the IGRT treatment through the image-guide to minimize errors between planned and actual treatment. Thus, to minimize imaging dose that the patients receive, when planning the treatment, it should be set up a treatment plan considering imaging dose, or it must be performed by minimizing the scan range when shooting MVCT.

Usefulness of Gated RapidArc Radiation Therapy Patient evaluation and applied with the Amplitude mode (호흡 동조 체적 세기조절 회전 방사선치료의 유용성 평가와 진폭모드를 이용한 환자적용)

  • Kim, Sung Ki;Lim, Hhyun Sil;Kim, Wan Sun
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.26 no.1
    • /
    • pp.29-35
    • /
    • 2014
  • Purpose : This study has already started commercial Gated RapidArc automation equipment which was not previously in the Gated radiation therapy can be performed simultaneously with the VMAT Gated RapidArc radiation therapy to the accuracy of the analysis to evaluate the usability, Amplitude mode applied to the patient. Materials and Methods : The analysis of the distribution of radiation dose equivalent quality solid water phantom and GafChromic film was used Film QA film analysis program using the Gamma factor (3%, 3 mm). Three-dimensional dose distribution in order to check the accuracy of Matrixx dosimetry equipment and Compass was used for dose analysis program. Periodic breathing synchronized with solid phantom signals Phantom 4D Phantom and Varian RPM was created by breathing synchronized system, free breathing and breath holding at each of the dose distribution was analyzed. In order to apply to four patients from February 2013 to August 2013 with liver cancer targets enough to get a picture of 4DCT respiratory cycle and then patients are pratice to meet patient's breathing cycle phase mode using the patient eye goggles to see the pattern of the respiratory cycle to be able to follow exactly in a while 4DCT images were acquired. Gated RapidArc treatment Amplitude mode in order to create the breathing cycle breathing performed three times, and then at intervals of 40% to 60% 5-6 seconds and breathing exercises that can not stand (Fig. 5), 40% While they are treated 60% in the interval Beam On hold your breath when you press the button in a way that was treated with semi-automatic. Results : Non-respiratory and respiratory rotational intensity modulated radiation therapy technique absolute calculation dose of using computerized treatment plan were shown a difference of less than 1%, the difference between treatment technique was also less than 1%. Gamma (3%, 3 mm) and showed 99% agreement, each organ-specific dose difference were generally greater than 95% agreement. The rotational intensity modulated radiation therapy, respiratory synchronized to the respiratory cycle created Amplitude mode and the actual patient's breathing cycle could be seen that a good agreement. Conclusion : When you are treated Non-respiratory and respiratory method between volumetric intensity modulated radiation therapy rotation of the absolute dose and dose distribution showed a very good agreement. This breathing technique tuning volumetric intensity modulated radiation therapy using a rotary moving along the thoracic or abdominal breathing can be applied to the treatment of tumors is considered. The actual treatment of patients through the goggles of the respiratory cycle to create Amplitude mode Gated RapidArc treatment equipment that does not automatically apply to the results about 5-6 seconds stopped breathing in breathing synchronized rotary volumetric intensity modulated radiation therapy facilitate could see complement.

A Study of the Effect of Model Characteristics on Purchasing intentions and Brand Attitudes (광고모델 특성이 구매의도와 브랜드태도에 미치는 영향)

  • Kim, Sung-Duck;Youn, Myoung-Kil;Kim, Ki-Soo
    • Journal of Distribution Science
    • /
    • v.10 no.4
    • /
    • pp.47-53
    • /
    • 2012
  • Businesses make use of advertising strategy using models to give consumers efficient product information. Modern advertisements often make use of models for greater reminiscence to create messages and remind viewers of the product. The purpose of this study was to examine the characteristics of each type of model. The subjects were 230 college students in their twenties or older, and the material was collected from October 20, 2011 to November 5, 2011 to examine the effects of model characteristics on buying intention as well as attitude toward a brand. A questionnaire survey was used; investigators gave one copy to each interviewee. The study investigated the characteristics of each model using a questionnaire of each 40 copies with five kinds of photographs. The characteristics of models had great influence on buying intention and attitude toward the brand: First, factor 2 (being honest and virtuous and having good credit and a good press assessment) and factor 3 (being interesting and a good communicator and creating good memories) had great influence on buying intention. Factor 2 was explained by reliability, and factor 3 by the efficiency of the model in creating a feeling. Second, factors 1 (being attractive, smart, unique, friendly, loved by others, and popular), 2, and 3 influenced attitude toward brand. Factor 1 encapsulated the outgoing characteristics of a model, factor 2 was based on reliability, and factor 3 was based on the efficiency of the model in creating a feeling. The model's positive effects on buying intention and attitudes toward brand shall be examined. For their positive influence on buying intention, reliability and efficiency shall be given attention. For their positive influence on attitude toward brand, creating a good impression, having outgoing characteristics, being reliable, and efficiency shall be given attention. The findings were as follows: Model characteristics influencing buying intention were similar to those influencing attitude toward brand. The differences were as follows. First, reliability and efficiency influenced buying intention. When customers were asked to consider the influence on buying intention of an advertisement, regardless of the strength of the buying intention, they considered these two characteristics. Customers decided to buy based not only on the credibility of the product as presented in the advertisement but also the transmission of the contents of the advertisement. Second, outgoing characteristics, reliability, and efficiency influenced attitude toward a brand. The attitude toward a brand was said to be the attitude toward the business. The attitude is produced even after buying, so businesses view it as very important. The attitude might vary depending upon the model used rather than the brand. Therefore, a model with outgoing characteristics was thought to be important. Therefore, attitude toward a brand whose model influenced buying intention as well as attitude toward brand had outgoing characteristics. The result is that an image the model was related to attitude toward the brand. As such, customers would buy the goods advertised. However, an outgoing image of a model was also important to create a positive attitude toward a business brand. For instance, talent Park Gyeong-Rim's photo was used to promote cosmetics about 10 years ago. When she worked as a model of cosmetics products, she had to make compensation for losses and damages because she made a mistake on a talk show program. At that time, customers who had bought the cosmetics product asked for refunds of several billion won. As such, models who are said to be the face of the businesses they represent can play an important role. To advertise in the most attractive and effective way, the current image of a model should be investigated by examining current activities and news articles after selecting the model, and the model's efficiency and attitude toward the brand should be examined. Factors that stimulate customers' buying decisions can be used to plan advertisement that have positive influence on a brand. This study had the limitation of investigating mainly college students and there were insufficient copies of the questionnaire. The investigation was not done widely but in detail so that a concrete investigation could not be done. Further studies shall supplement these shortcomings and discuss new directions.

  • PDF