• Title/Summary/Keyword: purpose

Search Result 155,985, Processing Time 0.149 seconds

A Study on the Effects of the Early Use of Nasal CPAP in the Weaning of Mechanical Ventilators (인공호흡기 이탈시 비강내 CPAP 조기 사용 효과에 관한 연구)

  • Kim, Yeoung Ju;Jung, Byun Kyung;Lee, Sang Geel
    • Clinical and Experimental Pediatrics
    • /
    • v.46 no.12
    • /
    • pp.1200-1206
    • /
    • 2003
  • Purpose : This study was conducted for the use of nasal continuous positive airway pressure (CPAP), by comparing the early use of non-invasive nasal CPAP with low intermittent mandatory ventilation(low IMV) and endotracheal CPAP in weaning a mechanical ventilator from infants with moderate respiratory distress syndrome(RDS). Methods : Thirty infants in the study group, with moderate RDS from November 2001 to June 2002, were administered surfactants and treated with the mechanical ventilator, and applied the nasal CPAP in weaning. Thirty infants of the control group, from January 1999 to September 2001, were applied low IMV and endoctracheal CPAP in weaning. Results : There were no significant differences in the characteristics, the severity of clinical symptoms, the initial laboratory findings and settings of the mechanical ventilator. After weaning, the study group showed no significant changes in $PaCO_2$. However, the control group showed a slight $CO_2$ retension after one and 12 hours. Twenty eight infants(93.3%) of the study group and 24 infants(80%) of the control group were successfully extubated. The primary cause of failure was apnea. There were no significant differences in the duration of weaning and the mechanical ventilator treatment between the groups. Complications in weaning were related to the fixation of nasal CPAP and the mechanical problems caused by endotracheal tube. Conclusion : Aggressive weaning is possible for moderate RDS, in which the nasal CPAP was used without the low IMV and the endotracheal CPAP process. It had no difficulties. In conclusion, the nasal CPAP is an adequate weaning method for moderate RDS.

Current feeding practices and maternal nutritional knowledge on complementary feeding in Korea (이유기 보충식 현황과 어머니 인식 조사)

  • Yom, Hye Won;Seo, Jeong Wan;Park, Hyesook;Choi, Kwang Hae;Chang, Ju Young;Ryoo, Eell;Yang, Hye Ran;Kim, Jae Young;Seo, Ji Hyun;Kim, Yong Joo;Moon, Kyung Rye;Kang, Ki Soo;Park, Kie Young;Lee, Seong Soo;Shim, Jeong Ok
    • Clinical and Experimental Pediatrics
    • /
    • v.52 no.10
    • /
    • pp.1090-1102
    • /
    • 2009
  • Purpose:To evaluate current feeding practices and maternal nutritional knowledge on complementary feeding. Methods:Mothers of babies aged 9-15 months who visited pediatric clinics of 14 general hospitals between September and December 2008 were asked to fill questionnaires. Data from 1,078 questionnaires were analyzed. Results:Complementary food was introduced at 4-7 months in 89% of babies. Home-made rice gruel was the first complementary food in 93% cases. Spoons were used for initial feeding in 97% cases. At 6-7 months, <50% of babies were fed meat (beef, 43%). Less than 12-month-old babies were fed salty foods such as salted laver (35%) or bean-paste soup (51%) and cow's milk (11%). The following were the maternal sources of information on complementary feeding: books/magazines (58%), friends (30%), internet web sites (29%), relatives (14%), and hospitals (4%). Compared to the 1993 survey, the incidence of complementary food introduction before 4 months (0.4% vs. 21%) and initial use of commercial food (7% vs. 39%) had decreased. Moreover, spoons were increasingly used for initial feeding (97% vs. 57%). The average maternal nutritional knowledge score was 7.5/10. Less percentage of mothers agreed with the following suggestions: bottle formula weaning before 15-18 months (68%), no commercial baby drinks as complementary food (67%), considering formula (or cow's milk) better than soy milk (65%), and feeding minced meat from 6-7 months (57%). Conclusion:Complementary feeding practices have considerably improved since the last decade. Pediatricians should advise timely introduction of appropriate complementary foods and monitor diverse information sources on complementary feeding.

The study of thermal change by chemoport in radiofrequency hyperthermia (고주파 온열치료시 케모포트의 열적 변화 연구)

  • Lee, seung hoon;Lee, sun young;Gim, yang soo;Kwak, Keun tak;Yang, myung sik;Cha, seok yong
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.27 no.2
    • /
    • pp.97-106
    • /
    • 2015
  • Purpose : This study evaluate the thermal changes caused by use of the chemoport for drug administration and blood sampling during radiofrequency hyperthermia. Materials and Methods : 20cm size of the electrode radio frequency hyperthermia (EHY-2000, Oncotherm KFT, Hungary) was used. The materials of the chemoport in our hospital from currently being used therapy are plastics, metal-containing epoxy and titanium that were made of the diameter 20 cm, height 20 cm insertion of the self-made cylindrical Agar phantom to measure the temperature. Thermoscope(TM-100, Oncotherm Kft, Hungary) and Sim4Life (Ver2.0, Zurich, Switzerland) was compared to the actual measured temperature. Each of the electrode measurement position is the central axis and the central axis side 1.5 cm, 0 cm(surface), 0.5 cm, 1.8 cm, 2.8 cm in depth was respectively measured. The measured temperature is $24.5{\sim}25.5^{\circ}C$, humidity is 30% ~ 32%. In five-minute intervals to measure the output power of 100W, 60 min. Results : In the electrode central axis 2.8 cm depth, the maximum temperature of the case with the unused of the chemoport, plastic, epoxy and titanium were respectively $39.51^{\circ}C$, $39.11^{\circ}C$, $38.81^{\circ}C$, $40.64^{\circ}C$, simulated experimental data were $42.20^{\circ}C$, $41.50^{\circ}C$, $40.70^{\circ}C$, $42.50^{\circ}C$. And in the central axis electrode side 1.5 cm depth 2.8 cm, mesured data were $39.37^{\circ}C$, $39.32^{\circ}C$, $39.20^{\circ}C$, $39.46^{\circ}C$, the simulated experimental data were $42.00^{\circ}C$, $41.80^{\circ}C$, $41.20^{\circ}C$, $42.30^{\circ}C$. Conclusion : The thermal variations were caused by radiofrequency electromagnetic field surrounding the chemoport showed lower than in the case of unused in non-conductive plastic material and epoxy material, the titanum chemoport that made of conductor materials showed a slight differences. This is due to the metal contents in the chemoport and the geometry of the chemoport. And because it uses a low radio frequency bandwidth of the used equipment. That is, although use of the chemoport in this study do not significantly affect the surrounding tissue. That is, because the thermal change is insignificant, it is suggested that the hazard of the chemoport used in this study doesn't need to be considered.

  • PDF

A study of usefulness for the plan based on only MRI using ViewRay MRIdian system (ViewRay MRIdian System을 이용한 MRI only based plan의 유용성 고찰)

  • Jeon, Chang Woo;Lee, Ho Jin;An, Beom Seok;Kim, Chan young;Lee, Je hee
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.27 no.2
    • /
    • pp.131-143
    • /
    • 2015
  • Purpose : By comparing a CT fusion plan based on MRI with a plan based on only MRI without CT, we intended to study usefulness of a plan based on only MRI. And furthermore, we intended to realize a realtime MR-IGRT by MRI image without CT scan during the course of simulation, treatment planning, and radiation treatment. Materials and Methods : BBB CT (Brilliance Big Bore CT, 16slice, Philips), Viewray MRIdian system (Viewray, USA) were used for CT & MR simulation and Treatment plan of 11 patients (1 Head and Neck, 5 Breast, 1 Lung, 3 Liver, 1 Prostate). When scanning for treatment, Free Breathing was enacted for Head&Neck, Breast, Prostate and Inhalation Breathing Holding for Lung and Liver. Considering the difference of size between CT and Viewray, the patient's position and devices were in the same condition. Using Viewray MRIdian system, two treatment plans were established. The one was CT fusion treatment plan based on MR image. Another was MR treatment plan including electron density that [ICRU 46] recommend for Lung, Air and Bone. For Head&Neck, Breast and Prostate, IMRT was established and for Lung and Liver, Gating treatment plan was established. PTV's Homogeneity Index(HI) and Conformity Index(CI) were use to estimate the treatment plan. And DVH and dose difference of each PTV and OAR were compared to estimate the treatment plan. Results : Between the two treatment plan, each difference of PTV's HI value is 0.089% (Head&Neck), 0.26% (Breast), 0.67% (Lung), 0.2% (Liver), 0.4% (Prostate) and in case of CI, 0.043% (Head&Neck), 0.84% (Breast), 0.68% (Lung), 0.46% (Liver), 0.3% (Prostate). As showed above, it is on Head&Neck that HI and CI's difference value is smallest. Each difference of average dose on PTV is 0.07 Gy (Head&Neck), 0.29 Gy (Breast), 0.18 Gy (Lung), 0.3 Gy (Liver), 0.18 Gy (Prostate). And by percentage, it is 0.06% (Head&Neck), 0.7% (Breast), 0.29% (Lung), 0.69% (Liver), 0.44% (Prostate). Likewise, All is under 1%. In Head&Neck, average dose difference of each OAR is 0.01~0.12 Gy, 0.04~0.06 Gy in Breast, 0.01~0.21 Gy in Lung, 0.06~0.27 Gy in Liver and 0.02~0.23 Gy in Prostate. Conclusion : PTV's HI, CI dose difference on the Treatment plan using MR image is under 1% and OAR's dose difference is maximum 0.89 Gy as heterogeneous tissue increases when comparing with that fused CT image. Besides, It characterizes excellent contrast in soft tissue. So, radiation therapy using only MR image without CT scan is useful in the part like Head&Neck, partial breast and prostate cancer which has a little difference of heterogeneity.

  • PDF

Effect of Dose Rate Variation on Dose Distribution in IMRT with a Dynamic Multileaf Collimator (동적다엽콜리메이터를 이용한 세기변조방사선 치료 시 선량분포상의 선량률 변화에 따른 효과)

  • Lim, Kyoung-Dal;Jae, Young-Wan;Yoon, Il-Kyu;Lee, Jae-Hee;Yoo, Suk-Hyun
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.24 no.1
    • /
    • pp.1-10
    • /
    • 2012
  • Purpose: To evaluate dose distribution differences when the dose rates are randomly changed in intensity-modulated radiation therapy using a dynamic multileafcollimator. Materials and Methods: Two IMRT treatment plans including small-field and large-field plans were made using a commercial treatment planning system (Eclipse, Varian, Palo Alto, CA). Each plan had three sub-plans according to various dose rates of 100, 400, and 600 MU/min. A chamber array (2D-Array Seven729, PTW-Freiburg) was positioned between solid water phantom slabs to give measurement depth of 5 cm and backscattering depth of 5 cm. Beam deliveries were performed on the array detector using a 6 MV beam of a linear accelerator (Clinac 21EX, Varian, Palo Alto, CA) equipped with 120-leaf MLC (Millenium 120, Varian). At first, the beam was delivered with same dose rates as planned to obtain reference values. After the standard measurements, dose rates were then changed as follows: 1) for plans with 100 MU/min, dose rate was varied to 200, 300, 400, 500 and 600 MU/min, 2) for plans with 400 MU/min, dose rate was varied to 100, 200, 300, 500 and 600 MU/min, 3) for plans with 600 MU/min, dose rate was varied to 100, 200, 300, 400 and 500 MU/min. Finally, using an analysis software (Verisoft 3.1, PTW-Freiburg), the dose difference and distribution between the reference and dose-rate-varied measurements was evaluated. Results: For the small field plan, the local dose differences were -0.8, -1.1, -1.3, -1.5, and -1.6% for the dose rate of 200, 300, 400, 500, 600 MU/min, respectively (for 100 MU/min reference), +0.9, +0.3, +0.1, -0.2, and -0.2% for the dose rate of 100, 200, 300, 500, 600 MU/min, respectively (for 400 MU/min reference) and +1.4, +0.8, +0.5, +0.3, and +0.2% for the dose rate of 100, 200, 300, 400, 500 MU/min, respectively (for 600 MU/min reference). On the other hand, for the large field plan, the pass-rate differences were -1.3, -1.6, -1.8, -2.0, and -2.4% for the dose rate of 200, 300, 400, 500, 600 MU/min, respectively (for 100 MU/min reference), +2.0, +1.8, +0.5, -1.2, and -1.6% for the dose rate of 100, 200, 300, 500, 600 MU/min, respectively (for 400 MU/min reference) and +1.5, +1.9, +1.7, +1.9, and +1.2% for the dose rate of 100, 200, 300, 400, 500 MU/min, respectively (for 600 MU/min reference). In short, the dose difference of dose-rate variation was measured to the -2.4~+2.0%. Conclusion: Using the Varian linear accelerator with 120 MLC, the IMRT dose distribution is differed a little <(${\pm}3%$) even though the dose-rate is changed.

  • PDF

Evaluation of Tangential Fields Technique Using TOMO Direct Radiation Therapy after Breast Partial Mastectomy (유방 부분 절제술 후 방사선 치료 시 TOMO Direct를 이용한 접선 조사의 선량적 유용성에 관한 고찰)

  • Kim, Mi-Jung;Kim, Joo-Ho;Kim, Hun-Kyum;Cho, Kang-Chul;Chun, Byeong-Chul;Cho, Jeong-Hee
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.23 no.1
    • /
    • pp.59-66
    • /
    • 2011
  • Purpose: Investigation of the clinical use of tangential fields technique using TOMO direct in comparison to conventional LINAC based radiation therapy after breast partial mastectomy. Materials and Methods: Treatment plans were created for 3 left-sided breast cancer patients who had radiation therapy after breast partial mastectomy by using wedged tangential fields technique, field in field technique (FIF), TOMO Direct, TOMO Direct intensity modulated radiation therapy (IMRT) under the normalized prescription condition ($D_{90%}$: 50.4 Gy/28 fx within CTV). Dose volume histogram (DVH) and isodose curve were used to evaluate the dose to the clinical target volume (CTV), organ at risk (OAR). We compared and analyzed dosimetric parameters of CTV and OAR. Dosimetric parameters of CTV are $D_{99}$, $D_{95}$, Dose homogeneity index (DHI: $D_{10}/D_{90}$) and $V_{105}$, $V_{110}$. And dosimetric parameters of OAR are $V_{10}$, $V_{20}$, $V_{30}$, $V_{40}$ of the heart and $V_{10}$, $V_{20}$, $V_{30}$ of left lung. Results: Dosimetric results of CTV, the average value of $D_{99}$, $D_{95}$ were $47.7{\pm}1.1Gy$, $49.4{\pm}0.1Gy$ from wedged tangential fields technique (W) and FIF (F) were $47.1{\pm}0.6Gy$, $49.2{\pm}0.4Gy$. And it was $49.2{\pm}0.4$ vs. $48.6{\pm}0.8Gy$, $49.9{\pm}0.4$ vs. $49.5{\pm}0.3Gy$ Gy for the TOMO Direct (D) and TOMO Direct IMRT (I). The average value of dose homogeneity index was W: $1.1{\pm}0.02$, F: $1.07{\pm}0.02$, D: $1.03{\pm}0.001$, I: $1.05{\pm}0.02$. When we compared the average value of $V_{105}$, $V_{110}$ using each technique, it was the highest as $34.6{\pm}9.3%$, $7.5{\pm}7.9%$ for wedged tangential fields technique and the value dropped for FIF as $16.5{\pm}14.8%$, $2.1{\pm}3.5%$, TOMO direct IMRT as $7.5{\pm}8.3%$, $0.1{\pm}0.1%$ and the TOMO direct showed the lowest values for both as 0%. Dosimetric results of OAR was no significant difference among each technique. Conclusion: TOMO direct provides improved target dose homogeneity over wedged tangential field technique. It is no increase the amount of normal tissue volumes receiving low doses, as oppose to IMRT or Helical TOMO IMRT. Also, it simply performs treatment plan procedure than FIF. TOMO Direct is a clinical useful technique for breast cancer patients after partial mastectomy.

  • PDF

Usefulness of Non-coplanar Helical Tomotherapy Using Variable Axis Baseplate (Variable Axis Baseplate를 이용한 Non-coplanar 토모테라피의 유용성)

  • Ha, Jin-Sook;Chung, Yoon-Sun;Lee, Ik-Jae;Shin, Dong-Bong;Kim, Jong-Dae;Kim, Sei-Joon;Jeon, Mi-Jin;Cho, Yoon-Jin;Kim, Ki-Kwang;Lee, Seul-Bee
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.23 no.1
    • /
    • pp.31-39
    • /
    • 2011
  • Purpose: Helical Tomotherapy allows only coplanar beam delivery because it does not allow couch rotation. We investigated a method to introduce non-coplanar beam by tilting a patient's head for Tomotherapy. The aim of this study was to compare intrafractional movement during Tomotherapy between coplanar and non-coplanar patient's setup. Materials and Methods: Helical Tomotherapy was used for treating eight patients with intracranial tumor. The subjects were divided into three groups: one group (coplanar) of 2 patients who lay on S-plate with supine position and wore thermoplastic mask for immobilizing the head, second group (non-coplanar) of 3 patients who lay on S-plate with supine position and whose head was tilted with Variable Axis Baseplate and wore thermoplastic mask, and third group (non-coplanar plus mouthpiece) of 3 patients whose head was tilted and wore a mouthpiece immobilization device and thermoplastic mask. The patients were treated with Tomotherapy after treatment planning with Tomotherapy Planning System. Megavoltage computed tomography (MVCT) was performed before and after treatment, and the intrafractional error was measured with lateral(X), longitudinal(Y), vertical(Z) direction movements and vector ($\sqrt{x^2+y^2+z^2}$) value for assessing overall movement. Results: Intrafractional error was compared among three groups by taking the error of MVCT taken after the treatment. As the correction values (X, Y, Z) between MVCT image taken after treatment and CT-simulation image are close to zero, the patient movement is small. When the mean values of movement of each direction for non-coplanar setup were compared with coplanar setup group, X-axis movement was decreased by 13%, but Y-axis and Z-axis movement were increased by 109% and 88%, respectively. Movements of Y-axis and Z-axis with non-coplanar setup were relatively greater than that of X-axis since a tilted head tended to slip down. The mean of X-axis movement of the group who used a mouthpiece was greater by 9.4% than the group who did not use, but the mean of Y-axis movement was lower by at least 64%, and the mean of Z-axis was lower by at least 67%, and the mean of Z-axis was lower by at least 67%, and the vector was lower by at least 59% with the use of a mouthpiece. Among these 8 patients, one patient whose tumor was located on left frontal lobe and left basal ganglia received reduced radiation dose of 38% in right eye, 23% in left eye, 30% in optic chiasm, 27% in brain stem, and 8% in normal brain with non-coplanar method. Conclusion: Tomotherapy only allows coplanar delivery of IMRT treatment. To complement this shortcoming, Tomotherapy can be used with non-coplanar method by artificially tilting the patient's head and using an oral immobilization instrument to minimize the movement of patient, when intracranial tumor locates near critical organs or has to be treated with high dose radiation.

  • PDF

Comparative analysis of food intake according to the family type of elderly women in Seoul area (서울 일부지역 여자 노인들의 가구유형에 따른 영양소 섭취실태 및 식사의 질 평가)

  • Lee, Yeon Joo;Kwon, Min Kyung;Baek, Hee Joon;Lee, Sang Sun
    • Journal of Nutrition and Health
    • /
    • v.48 no.3
    • /
    • pp.277-288
    • /
    • 2015
  • Purpose: As the rate of senior citizens living alone increases in the current aging society, there is much concern regarding the health and nutritional intake of solitary senior citizens. Therefore, this study compared the nutritional intake of senior citizens according to their family type. Methods: In July and August of 2011, two senior citizen welfare centers in Seoul were visited to survey 267 elderly women. Excluding 54 subjects for which the data were incomplete, information from 213 subjects was analyzed. The subjects were divided into three family types, living alone (LA, n = 74), living with spouse (LS, n = 78), and living with children (LC, n = 61). Results: The mean age of the LA group was the highest, while the mean age of the LS group was the lowest (p < 0.001), and WHR of the LC group was the highest (p = 0.049). Income was the highest in the LS group (p < 0.001). Frequency of eating out was the lowest in the LA group (p = 0.031). By Duncan's multiple analysis, the amounts of energy intake, vegetable protein, fat, calcium, phosphorus, potassium, selenium, Vit D, Vit E, $Vit\;B_2$, niacin, $Vit\;B_6$, $Vit\;B_{12}$, and cholesterol were significantly higher in the LS group compared with the LA or LC group (p < 0.05). The intakes of calcium, Vit D, $Vit\;B_{12}$, and cholesterol were still significantly different among the three groups, even after adjustment for age and monthly income. The LA group ate less fruit and fish than the LS or LC group (p < 0.05). The LA group showed the lowest dietary diversity and the LS group showed the highest diversity (p = 0.014), however, the significance of dietary diversity score among the three groups disappeared after adjustment for age and monthly income. Conclusion: Elderly women living with spouse were receiving better nutrition than elderly women living alone or living with children. Therefore, solitary elderly women who do not live with their spouse or children should be offered greater opportunities to receive a balanced meal at a congregational kitchen or welfare center. To ensure their healthy diet, it is essential to provide continuous nutrition education with these groups in mind.

A Case Study on Application of the Menu Engineering Technique in Government Offices Contract Foodservice (관공서급식소의 메뉴엔지니어링기법을 적용한 메뉴분석 사례연구)

  • Rho, Sung-Yoon
    • Journal of Nutrition and Health
    • /
    • v.42 no.1
    • /
    • pp.78-96
    • /
    • 2009
  • The purpose of this study was to analyze and evaluate the menu served in government offices foodservice by using Kasavana & Smith's Menu-Engineering. Sales and food costs were collected from the daily sales reports for a year from Jan 2 to Dec 31 in 2007. Calculation for menu analysis and customer's data were done by computer using the MS 2003 Excel spreadsheet program and SPSS 12.0 package program. Menu mix% (MM%) and unit contribution margin were used as variables by Kasavana & Smith. Four possible classifications by Menu-Engineering technique were turned out as 'STAR', 'PLOWHORSE', 'PUZZLE', 'DOG'. The main menus served during a year were 128 dishes and about 141 peoples visited this restaurant daily. The mean age of the men was $44.1\;{\pm}\;6.3$, women were $32.7\;{\pm}\;6.4$ and showed that was statistically higher than that of women (p < .0001). The rates of STAR menus were 'Western style (75.0%)', 'guk/tang-ryu (48.1%)', 'jjigae/ jeongol-ryu (23.1%)', 'bap-ryu (17.2%)' in sequence. There were no STAR menus in gui/jorim/jjim-ryu. PLOWHORSE menus were 'gui-ryu (75.0%)', 'guk/tang-ryu (29.6%)', 'bap-ryu (27.6%)' in sequence. There were no PUZZLE or DOG menus in 'jjigae/jeongol-ryu'. PUZZLE menus were 'jorim/jjim-ryu and Myeonryu (each 33.3%)', 'bap-ryu (31.0%)' in sequence. PUZZLE menus were a lots of 'Chinese food (75.0%)' and 'myeonryu (55.6%)'. This study provides the basic data based on regularly menu analysis method applied the scientific menu analysis techniques in government offices food services, I'd like to suggest that the menu management must be done based on the necessity and result of menu analysis according to the seasonal and middle, long-term plans.

The Causes of Conflict and the Effect of Control Mechanisms on Conflict Resolution between Manufacturer and Supplier (제조-공급자간 갈등 원인과 거래조정 방식의 갈등관리 효과)

  • Rhee, Jin Hwa
    • Journal of Distribution Research
    • /
    • v.17 no.4
    • /
    • pp.55-80
    • /
    • 2012
  • I. Introduction Developing the relationships between companies is very important issue to ensure a competitive advantage in today's business environment (Bleeke & Ernst 1991; Mohr & Spekman 1994; Powell 1990). Partnerships between companies are based on having same goals, pursuing mutual understanding, and having a professional level of interdependence. By having such a partnerships and cooperative efforts between companies, they will achieve efficiency and effectiveness of their business (Mohr and Spekman, 1994). However, it is difficult to expect these ideal results only in the B2B corporate transaction. According to agency theory which is the well-accepted theory in various fields of business strategy, organization, and marketing, the two independent companies have fundamentally different corporate purposes. Also there is a higher chance of developing opportunism and conflict due to natures of human(organization), such as self-interest, bounded rationality, risk aversion, and environment factor as imbalance of information (Eisenhardt 1989). That is, especially partnerships between principal(or buyer) and agent(or supplier) of companies within supply chain, the business contract itself will not provide competitive advantage. But managing partnership between companies is the key to success. Therefore, managing partnership between manufacturer and supplier, and finding causes of conflict are essential to improve B2B performance. In conclusion, based on prior researches and Agency theory, this study will clarify how business hazards cause conflicts on supply chain and then identify how developed conflicts have been managed by two control mechanisms. II. Research model III. Method In order to validate our research model, this study gathered questionnaires from small and medium sized enterprises(SMEs). In Korea, SMEs mean the firms whose employee is under 300 and capital is under 8 billion won(about 7.2 million dollar). We asked the manufacturer's perception about the relationship with the biggest supplier, and our key informants are denied to a person responsible for buying(ex)CEO, executives, managers of purchasing department, and so on). In detail, we contact by telephone to our initial sample(about 1,200 firms) and introduce our research motivation and send our questionnaires by e-mail, mail, and direct survey. Finally we received 361 data and eliminate 32 inappropriate questionnaires. We use 329 manufactures' data on analysis. The purpose of this study is to identify the anticipant role of business hazard (environmental dynamism, asset specificity) and investigate the moderating effect of control mechanism(formal control, social control) on conflict-performance relationship. To find out moderating effect of control methods, we need to compare the regression weight between low versus. high group(about level of exercised control methods). Therefore we choose the structural equation modeling method that is proper to do multi-group analysis. The data analysis is performed by AMOS 17.0 software, and model fits are good statically (CMIN/DF=1.982, p<.000, CFI=.936, IFI=.937, RMSEA=.056). IV. Result V. Discussion Results show that the higher environmental dynamism and asset specificity(on particular supplier) buyer(manufacturer) has, the more B2B conflict exists. And this conflict affect relationship quality and financial outcomes negatively. In addition, social control and formal control could weaken the negative effect of conflict on relationship quality significantly. However, unlikely to assure conflict resolution effect of control mechanisms on relationship quality, financial outcomes are changed by neither social control nor formal control. We could explain this results with the characteristics of our sample, SMEs(Small and Medium sized Enterprises). Financial outcomes of these SMEs(manufacturer or principal) are affected by their customer(usually major company) more easily than their supplier(or agent). And, in recent few years, most of companies have suffered from financial problems because of global economic recession. It means that it is hard to evaluate the contribution of supplier(agent). Therefore we also support the suggestion of Gladstein(1984), Poppo & Zenger(2002) that relational performance variable can capture the focal outcomes of relationship(exchange) better than financial performance variable. This study has some implications that it tests the sources of conflict and investigates the effect of resolution methods of B2B conflict empirically. And, especially, it finds out the significant moderating effect of formal control which past B2B management studies have ignored in Korea.

  • PDF