• Title/Summary/Keyword: purpose

Search Result 155,985, Processing Time 0.152 seconds

CT Evaluation of Long-Term Changes in Common Bile Duct Diameter after Cholecystectomy (담낭 절제술 후 총담관 직경의 장기 변화에 대한 CT 평가)

  • Sung Hee Ahn;Chansik An;Seung-seob Kim;Sumi Park
    • Journal of the Korean Society of Radiology
    • /
    • v.85 no.3
    • /
    • pp.581-595
    • /
    • 2024
  • Purpose The present study aimed to investigate the frequency and extent of compensatory common bile duct (CBD) dilatation after cholecystectomy, assess the time between cholecystectomy and CBD dilatation, and identify potentially useful CT findings suggestive of obstructive CBD dilatation. Materials and Methods This retrospective study included 121 patients without biliary obstruction who underwent multiple CT scans before and after cholecystectomy at a single center between 2009 and 2011. The maximum short-axis diameters of the CBD and intrahepatic duct (IHD) were measured on each CT scan. In addition, the clinical and CT findings of 11 patients who were initially excluded from the study because of CBD stones or periampullary tumors were examined to identify distinguishing features between obstructive and non-obstructive CBD dilatation after cholecystectomy. Results The mean (standard deviation) short-axis maximum CBD diameter of 121 patients was 5.6 (± 1.9) mm in the axial plane before cholecystectomy but increased to 7.9 (± 2.6) mm after cholecystectomy (p < 0.001). Of the 106 patients with a pre-cholecystectomy axial CBD diameter of < 8 mm, 39 (36.8%) showed CBD dilatation of ≥ 8 mm after cholecystectomy. Six of the 17 patients with long-term (> 2 years) serial follow-up CT scans (35.3%) eventually showed a significant (> 1.5-fold) increase in the axial CBD diameter, all within two years after cholecystectomy. Of the 121 patients without obstruction or related symptoms, only one patient (0.1%) showed IHD dilatation > 3 mm after cholecystectomy. In contrast, all 11 patients with CBD obstruction had abdominal pain and abnormal laboratory indices, and 81.8% (9/11) had significant dilatation of the IHD and CBD. Conclusion Compensatory non-obstructive CBD dilatation commonly occurs after cholecystectomy to a similar extent as obstructive dilatation. However, the presence of relevant symptoms, significant IHD dilatation, or further CBD dilatation 2-3 years after cholecystectomy should raise suspicion of CBD obstruction.

The Comparison of Efficacy and Safety between Radiofrequency Ablation Alone and Ethanol Ablation Followed by Radiofrequency Ablation in the Treatment of Mixed Cystic and Solid Thyroid Nodule (낭성 및 고형성 혼합 갑상선 결절 치료에서 고주파 절제술 단독요법과 에탄올 절제 후 고주파 절제술 요법의 유효성 및 안전성 비교)

  • Min Gang Jo;Min Kyoung Lee;Jae Ho Shin;Min Guk Seo;So Lyung Jung
    • Journal of the Korean Society of Radiology
    • /
    • v.85 no.3
    • /
    • pp.618-630
    • /
    • 2024
  • Purpose To compare the efficacy and safety of radiofrequency ablation (RFA) and ethanol ablation (EA) followed by RFA in treating mixed cystic and solid thyroid nodules. Materials and Methods We included 243 nodules from 243 patients who underwent RFA for mixed cystic and solid benign nodules. The nodules were divided into two groups (RFA alone and EA + RFA). We evaluated volume reduction rate (VRR), therapeutic success rate, improvement in symptomatic and cosmetic issues, complications, and adverse effects. Results The RFA group included 204 patients, and the EA + RFA group included 39 patients. The long-term success rates in the RFA only and EA + RFA groups were 90.2% and 97.4%, respectively. The mean VRR at the last follow-up in the RFA and EA + RFA groups were 81.6% and 87.2%, respectively. Therapeutic results were similar in both groups at the last followup. Cosmetic and symptomatic problems markedly improved in both groups. No major complications were observed. Conclusion Both RFA alone and EA + RA are safe and effective methods for treating mixed cystic and solid thyroid nodules, although EA + RFA is slightly more effective.

Impact of Respiratory Phase during Pleural Puncture on Complications in CT-Guided Percutaneous Lung Biopsy (CT 유도 경피 폐생검에서 흉막 천자 시 호흡 시기가 합병증에 미치는 영향)

  • Ji Young Park;Ji-Yeon Han;Seok Jin Choi;Jin Wook Baek;Su Young Yun;Sung Kwang Lee;Ho Young Lee;SungMin Hong
    • Journal of the Korean Society of Radiology
    • /
    • v.85 no.3
    • /
    • pp.566-578
    • /
    • 2024
  • Purpose This study investigated whether the respiratory phase during pleural puncture in CT-guided percutaneous transthoracic needle biopsy (PTNB) affects complications. Materials and Methods We conducted a retrospective review of 477 lung biopsy CT scans performed during free breathing. The respiratory phases during pleural puncture were determined based on the table position of the targeted nodule using CT scans obtained during free breathing. We compared the rates of complications among the inspiratory, mid-, and expiratory respiratory phases. Logistic regression analysis was performed to control confounding factors associated with pneumothorax. Results Among the 477 procedures, pleural puncture was performed during the expiratory phase in 227 (47.6%), during the mid-phase in 108 (22.6%), and during the inspiratory phase in 142 (29.8%). The incidence of pneumothorax was significantly lower in the expiratory puncture group (40/227, 17.6%; p = 0.035) and significantly higher in the mid-phase puncture group (31/108, 28.7%; p = 0.048). After controlling for confounding factors, expiratory-phase puncture was found to be an independent protective factor against pneumothorax (odds ratio = 0.571; 95% confidence interval = 0.360-0.906; p = 0.017). Conclusion Our findings suggest that pleural puncture during the expiratory phase may reduce the risk of pneumothorax during image guided PTNB.

Is a Camera-Type Portable X-Ray Device Clinically Feasible in Chest Imaging?: Image Quality Comparison with Chest Radiographs Taken with Traditional Mobile Digital X-Ray Devices (카메라형 휴대형 X선 장치는 흉부 촬영에서 임상적 사용이 가능한가?: 기존의 이동형 디지털 X선 장치로 촬영한 흉부 X선 사진과 영상품질 비교)

  • Sang-Ji Kim;Hwan Seok Yong;Eun-Young Kang;Zepa Yang;Jung-Youn Kim;Young-Hoon Yoon
    • Journal of the Korean Society of Radiology
    • /
    • v.85 no.1
    • /
    • pp.138-146
    • /
    • 2024
  • Purpose To evaluate whether the image quality of chest radiographs obtained using a camera-type portable X-ray device is appropriate for clinical practice by comparing them with traditional mobile digital X-ray devices. Materials and Methods Eighty-six patients who visited our emergency department and underwent endotracheal intubation, central venous catheterization, or nasogastric tube insertion were included in the study. Two radiologists scored images captured with traditional mobile devices before insertion and those captured with camera-type devices after insertion. Identification of the inserted instruments was evaluated on a 5-point scale, and the overall image quality was evaluated on a total of 20 points scale. Results The identification score of the instruments was 4.67 ± 0.71. The overall image quality score was 19.70 ± 0.72 and 15.02 ± 3.31 (p < 0.001) for the mobile and camera-type devices, respectively. The scores of the camera-type device were significantly lower than those of the mobile device in terms of the detailed items of respiratory motion artifacts, trachea and bronchus, pulmonary vessels, posterior cardiac blood vessels, thoracic intervertebral disc space, subdiaphragmatic vessels, and diaphragm (p = 0.013 for the item of diaphragm, p < 0.001 for the other detailed items). Conclusion Although caution is required for general diagnostic purposes as image quality degrades, a camera-type device can be used to evaluate the inserted instruments in chest radiographs.

Tumor Margin Infiltration in Soft Tissue Sarcomas: Prediction Using 3T MRI Texture Analysis (연조직 육종의 종양 가장자리 침윤: 3T 자기공명영상 텍스처 분석을 통한 예측)

  • Minji Kim;Won-Hee Jee;Youngjun Lee;Ji Hyun Hong;Chan Kwon Jung;Yang-Guk Chung;So-Yeon Lee
    • Journal of the Korean Society of Radiology
    • /
    • v.83 no.1
    • /
    • pp.112-126
    • /
    • 2022
  • Purpose To determine the value of 3 Tesla (T) MRI texture analysis for predicting tumor margin infiltration in soft tissue sarcomas. Materials and Methods Thirty-one patients who underwent 3T MRI and had a pathologically confirmed diagnosis of soft tissue sarcoma were included in this study. Margin infiltration on pathology was used as the gold standard. Texture analysis of soft tissue sarcomas was performed on axial T1-weighted images (WI) and T2WI, fat-suppressed contrast-enhanced (CE) T1WI, diffusion-weighted images (DWI) with b-value of 800 s/mm2, and apparent diffusion coefficient (ADC) was mapped. Quantitative parameters were compared between sarcomas with infiltrative margins and those with circumscribed margins. Results Among the 31 patients with soft tissue sarcomas, 23 showed tumor margin infiltration on pathology. There were significant differences in kurtosis with the spatial scaling factor (SSF) of 0 and 6 on T1WI, kurtosis (SSF, 0) on CE-T1WI, skewness (SSF, 0) on DWI, and skewness (SSF, 2, 4) on ADC between sarcomas with infiltrative margins and those with circumscribed margins (p ≤ 0.046). The area under the receiver operating characteristic curve based on MR texture features for identification of infiltrative tumor margins was 0.951 (p < 0.001). Conclusion MR texture analysis is reliable and accurate for the prediction of infiltrative margins of soft tissue sarcomas.

Computer-Aided Diagnosis Parameters of Invasive Carcinoma of No Special Type on 3T MRI: Correlation with Pathologic Immunohistochemical Markers (3T 자기공명영상에서 비특이 침윤성 유방암의 컴퓨터보조진단 인자들과 병리적 면역조직화학 표지자들과의 상관성)

  • Jinho Jeong;Chang Suk Park;Jung Whee Lee;Kijun Kim;Hyeon Sook Kim;Sun-Young Jun;Se-Jeong Oh
    • Journal of the Korean Society of Radiology
    • /
    • v.83 no.1
    • /
    • pp.149-161
    • /
    • 2022
  • Purpose To investigate the correlation between computer-aided diagnosis (CAD) parameters in 3-tesla (T) MRI and pathologic immunohistochemical (IHC) markers in invasive carcinoma of no special type (NST). Materials and Methods A total of 94 female who were diagnosed with NST carcinoma and underwent 3T MRI using CAD, from January 2018 to April 2019, were included. The relationship between angiovolume, curve peak, and early and late profiles of dynamic enhancement from CAD with pathologic IHC markers and molecular subtypes were retrospectively investigated using Dwass, Steel, Critchlow-Fligner multiple comparison analysis, and univariate binary logistic regression analysis. Results In NST carcinoma, a higher angiovolume was observed in tumors of higher nuclear and histologic grades and in lymph node (LN) (+), estrogen receptor (ER) (-), progesterone receptor (PR) (-), human epidermal growth factor 2 (HER2) (+), and Ki-67 (+) tumors. A high rate of delayed washout and a low rate of delayed persistence were observed in Ki-67 (+) tumors. In the binary logistic regression analysis of NST carcinoma, a high angiovolume was significantly associated with a high nuclear and histologic grade, LN (+), ER (-), PR (-), HER2 (+) status, and non-luminal subtypes. A high rate of washout and a low rate of persistence were also significantly correlated with the Ki-67 (+) status. Conclusion Angiovolume and delayed washout/persistent rate from CAD parameters in contrast enhanced breast MRI correlated with predictive IHC markers. These results suggest that CAD parameters could be used as clinical prognostic, predictive factors.

Prevalence of Incidentally Detected Spondylolysis in Children (소아 환자에서 우연히 발견되는 척추분리증의 유병률)

  • Boram Song;Sun Kyoung You;Jeong Eun Lee;So Mi Lee;Hyun-Hae Cho
    • Journal of the Korean Society of Radiology
    • /
    • v.83 no.1
    • /
    • pp.127-137
    • /
    • 2022
  • Purpose To assess the prevalence of incidentally detected lumbar spondylolysis in children. Materials and Methods We retrospectively reviewed the data of 809 patients under the age of 11 years (mean age, 7.0 ± 2.7 years; boys:girls = 479:330) who underwent abdominal and pelvic CT between March 2014 and December 2018. We recorded the presence, level, and laterality (unilateral or bilateral) of spondylolysis. Patients were divided into two groups based on the presence of spondylolysis: the spondylolysis (SP) and non-SP groups. Results In total, 21 cases of spondylolysis were detected in 20 patients (20/809, 2.5%). The mean age of the SP group was higher than that of the non-SP group (7.8 ± 1.8 vs. 6.9 ± 2.7 years, p > 0.05). The prevalence of spondylolysis in boys was higher than that in girls (15/479 [3.1%] vs. 5/330 [1.5%], p > 0.05). The prevalence of spondylolysis in school-age children (6-10 year olds) was higher than that in preschool-age children (0-5 year olds) (17/538 [3.2%] vs. 3/271 [1.1%], p > 0.05). L5 was the most common level of spondylolysis (76.2%); one 8-year-old boy had two-level spondylolysis. One case of isthmic spondylolisthesis was detected in a 10-year-old boy (1/809, 0.1%). There were 11 unilateral spondylolysis cases (11/21, 52.4%). Conclusion In our study, the prevalence of spondylolysis in children under the age of 11 was 2.5%. The prevalence was higher in boys than in girls and in school-age than in preschool-age children, despite the lack of any statistically significant differences.

Correlation Analysis between Fat Fraction and Bone Mineral Density Using the DIXON Method for Fat Dominant Tissue in Knee Joint MRI: A Preliminary Study (지방우세 딕슨기법을 이용한 슬관절 자기공명영상 지방신호분율과 골밀도 간의 상관관계 분석: 예비 연구)

  • Sung Hyun An;Kyu-Sung Kwack;Sunghoon Park;Jae Sung Yun;Bumhee Park;Ji Su Kim
    • Journal of the Korean Society of Radiology
    • /
    • v.84 no.2
    • /
    • pp.427-440
    • /
    • 2023
  • Purpose This study aimed to investigate the correlation between the fat signal fraction (FF) of the fat-dominant bone tissue of the knee joint, measured using the MRI Dixon method (DIXON) technique, and bone mineral density (BMD). Materials and Methods Among the patients who underwent knee DIXON imaging at our institute, we retrospectively analyzed 93 patients who also underwent dual energy X-ray absorptiometry within 1 year. The FFs of the distal femur metaphyseal (Fm) and proximal tibia metaphyseal (Tm) were calculated from the DIXON images, and the correlation between FF and BMD was analyzed. Patients were grouped based on BMD of lumbar spine (L), femoral neck (FN), and common femur (FT) respectively, and the Kruskal-Wallis H test was performed for FF. Results We identified a significant negative correlation between TmFF and FN-BMD in the entire patient group (r = -0.26, p < 0.05). In female patients, TmFF showed a negative correlation with FN-BMD, FT-BMD, and L-BMD (r = -0.38, 0.28 and -0.27, p < 0.05). In male patients, FmFF was negatively correlated with only FN-BMD and FT-BMD (r = -0.58 and -0.42, p < 0.05). There was a significant difference in the TmFF between female patients grouped by BMD (p < 0.05). In male patients, there was a significant difference in FmFF (p < 0.05). Conclusion Overall, we found that FF and BMD around the knee joints showed a negative correlation. This suggests the potential of FF measurement using DIXON for BMD screening.

Development of Rabbit Brain Tumor Model Using VX2 Cells and Verification with the MRI in Neuroradiologic Research (Neuroradiology 연구를 위한 VX2 세포를 이용한 토끼 뇌종양 모델 제작과 MRI를 이용한 검증)

  • Yong-Woo Kim;Seon Hee Choi;Hak Jin Kim
    • Journal of the Korean Society of Radiology
    • /
    • v.84 no.2
    • /
    • pp.441-453
    • /
    • 2023
  • Purpose To evaluate the development, location, and volume of a VX2 carcinoma using four inoculation methods in a rabbit brain. Materials and Methods Inoculation of a VX2 cell suspension was performed 1) on the appointed day, 2) seven days after storing a VX2 carcinoma in a freezer or 3) seven days after storing a VX2 carcinoma in a deep freezer after sacrificing the donor rabbits. 4) Without sacrificing the rabbits, the VX2 cell suspension was obtained using a gun biopsy, inoculation was performed on the appointed day. MR imaging was performed 10 days after inoculation. Brain tissues were obtained the day after. The development, location, and volume of the tumor were evaluated. Results Seventeen of the 18 rabbits inoculated on the appointed day developed tumors (average tumor volume, 106.32 mm3). One of five inoculated seven days after storing the VX2 tumor in the freezer, and three of five inoculated seven days after storing the VX2 tumor in the deep freezer developed tumors. Inoculation with a VX2 cell suspension obtained with a gun biopsy from five rabbits revealed development of tumors in only two rabbits. The tumors mostly developed in the superficial cortex. Conclusion TVX2 rabbit brain tumor model is easy to develop and revealed variable reproducibility. This model can be applicable in radiologic imaging, treatment planning, interventional treatment and drug delivery research. VX2 cell can be successfully innoculated into the brain using variable methods under researcher's variable conditions.

Comparison of True and Virtual Non-Contrast Images of Liver Obtained with Single-Source Twin Beam and Dual-Source Dual-Energy CT (간의 단일선원 Twin Beam과 이중선원 이중에너지 전산화단층촬영의 비조영증강 영상과 가상 비조영증강 영상의 비교 연구)

  • Jeong Sub Lee;Guk Myung Choi;Bong Soo Kim;Su Yeon Ko;Kyung Ryeol Lee;Jeong Jae Kim;Doo Ri Kim
    • Journal of the Korean Society of Radiology
    • /
    • v.84 no.1
    • /
    • pp.170-184
    • /
    • 2023
  • Purpose To assess the magnitude of differences between attenuation values of the true non-contrast image (TNC) and virtual non-contrast image (VNC) derived from twin-beam dual-energy CT (tbDECT) and dual-source DECT (dsDECT). Materials and Methods This retrospective study included 62 patients who underwent liver dynamic DECT with tbDECT (n = 32) or dsDECT (n = 30). Arterial VNC (AVNC), portal VNC (PVNC), and delayed VNC (DVNC) were reconstructed using multiphasic DECT. Attenuation values of multiple intra-abdominal organs (n = 11) on TNCs were subsequently compared to those on multiphasic VNCs. Further, we investigated the percentage of cases with an absolute difference between TNC and VNC of ≤ 10 Hounsfield units (HU). Results For the mean attenuation values of TNC and VNC, 33 items for each DECT were compared according to the multiphasic VNCs and organs. More than half of the comparison items for each DECT showed significant differences (tbDECT 17/33; dsDECT 19/33; Bonferroni correction p < 0.0167). The percentage of cases with an absolute difference ≤ 10 HU was 56.7%, 69.2%, and 78.6% in AVNC, PVNC, and DVNC in tbDECT, respectively, and 70.5%, 78%, and 78% in dsDECT, respectively. Conclusion VNCs derived from the two DECTs were insufficient to replace TNCs because of the considerable difference in attenuation values.