• Title/Summary/Keyword: purging

Search Result 177, Processing Time 0.026 seconds

Carbonate scale reduction in reverse osmosis membrane by CO2 in wastewater reclamation

  • Shahid, Muhammad Kashif;Pyo, Minsu;Choi, Young-Gyun
    • Membrane and Water Treatment
    • /
    • v.8 no.2
    • /
    • pp.125-136
    • /
    • 2017
  • Reverse osmosis technology is being used on large scale for treatment of ground water, brackish water, wastewater and sea water. The most challenging issue in RO process is carbonate scaling which is directly linked with the efficiency and economy. Considering the natural phenomena of carbonate scaling different adaptations have been made to control scaling on the surface of RO membrane including acid dosage and antiscalant addition. As carbonate scaling is directly related with pH level of feed water, present study describes an experimental approach to reduce scaling on RO membrane by lowering the feed water pH by purging $CO_2$. In this comparative study four different conditions including control process (without any scale inhibitor), with dosage of antiscalant, with purging of $CO_2$ and with co addition of antiscalant and $CO_2$ in a feed stream line; it was established that $CO_2$ is a better appliance to reduce carbonate scaling on the membrane surface by reduce pH of feed stream. It was also observed that $CO_2$ and antiscalant mutually function better for scale control.

Negative Effects of Inbreeding of Artificially Bottlenecked Drosophila melanogaster Populations

  • Kim, Baek-Jun
    • Proceedings of the National Institute of Ecology of the Republic of Korea
    • /
    • v.2 no.2
    • /
    • pp.108-113
    • /
    • 2021
  • Detrimental effects of inbreeding have been studied by many researchers for a long time. However, only a few studies have shown the occurrence of inbreeding depression due to evolutionary changes as a purging process. In this study, two different populations (inbreeding and outbreeding) of Drosophila melanogaster were compared to assess inbreeding effects on artificial population bottlenecks. For inbreeding conditions, a couple of D. melanogaster (one virgin and one male) were selected from an inbred population and cultured in a vial. For outbreeding conditions, a couple of D. melanogaster were selected from different populations and cultured in a vial. There were significant differences in body lengths of adults, but not in other parameters such as the total number of adults, the rate of survival, and the rate of wing mutants. The mean body length of adults of outbreeding populations was longer than that of inbreeding populations in the first generation (G1; P = 0.004), but not in the second generation (G2; P = 0.066). Although the other three parameters (total number of adults, rate of survival, and rate of wing mutants) showed differences in their mean values between inbreeding and outbreeding populations, these differences were not statistically significant. This might be due to genetic purging. This study demonstrated one additional experimental case related to inbreeding depression in artificial bottlenecked populations. Further studies are necessary to confirm the clear interaction between inbreeding depression and genetic purging using more generations and replicates (or samples) of D. melanogaster.

Analysis of the Contents in Stabilized Chlorine Dioxide (안정화 이산화염소의 성분분석)

  • Shin, Ho-Sang;Oh-Shin, Yun-Suk
    • Analytical Science and Technology
    • /
    • v.12 no.5
    • /
    • pp.403-407
    • /
    • 1999
  • A method for detecting chlorine dioxide in drinking water was developed by the modified iodometric titration. This method requires prior removal of interfering chemicals such as chlorine and/or other oxidants: the interferents are removed by $N_2$ purging. Chlorite and chlorate were successfully quantified by the ion chromatography-conductivity detection. Stabilized chlorine dioxide that is commercially available contained only traces of chlorine dioxide (0.01-0.09%). In reality, its main component is chlorite.

  • PDF

The Characteristics of Ventilation in Railway Tunnel (철도터널의 환기특성에 관한 연구)

  • Yoo, Ji-oh;Shin, Hyun-Jun;Lee, Ho-Seok
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.2 no.2
    • /
    • pp.22-31
    • /
    • 2000
  • This study aimed at investigating the influence of tunnel length and area, drag coefficient, train velocity on the characteristics of ventilation in railway tunnel. The modified Subway Environment Simulation(SES) computer program has been used to calculate the flow velocity and longitudinal emission concentration with various condition. According to a series of numerical simulation, the influence of various parameter on maximum air flow velocity, purging length and emission concentration are estimated.

  • PDF

Effects of Quasi-Carbonization Process on the Mechanical Properties of Spun Yarn Type Quasi-Carbon Fabrics

  • Donghwan Cho;Lee, Jongmoon;Park, Jon-Kyoo
    • Macromolecular Research
    • /
    • v.10 no.6
    • /
    • pp.318-324
    • /
    • 2002
  • In this paper we have extensively studied what and how processing parameters for quasi-carbonization influence the breaking strength and modulus of resulting quasi-carbon fabrics that are prepared from stabilized PAN fabrics with a spun yarn texture. Seven processing parameters have been considered as follows: applied tension, final heat-treatment temperature, heating rate, heating step, holding time, cooling rate, and purging gas purity. The results indicate that optimal uses of applied tension, final heat-treatment temperature, heating rate, and heating step during quasi-carbonization process are primarily important to increase the tensile properties of quasi-carbon fabrics and holding time, cooling rate, and purging gas purity are less importantly contributed.

CFD analysis of ventilation efficiency around an elevated highway using visitation frequency and purging flow rate

  • Huang, Hong;Kato, Shinsuke;Ooka, Ryozo;Jiang, Taifeng
    • Wind and Structures
    • /
    • v.9 no.4
    • /
    • pp.297-313
    • /
    • 2006
  • The concentration of air pollution along roads is higher than the surrounding area because ventilation efficiency has decreased due to the high-density use of space along roads in recent years. In this study, ventilation efficiency around a heavily traffic road covered by an elevated highway and hemmed in along its side by buildings is evaluated using Visitation Frequency (VF, the frequency for pollutant to return to the objective domain) and Purging Flow Rate (PFR, the air flow rate for defining the local domain-averaged concentration). These are analyzed using Computational Fluid Dynamics (CFD) based on the standard $k-{\varepsilon}$ model. The VF and PFR characteristics of four objective domains are analyzed in terms of the changes in wind direction and arrangements of the fencing dividing up and down direction in the road center under the elevated highway. The resulting VFs are more than 1.0 for all cases, which means that pollutants return to the objective domain restricted by the elevated highway and side buildings. The influence of the arrangement of the buildings around the objective domain and the structure in the domain on the VF is substantial. In cases where there are no obstacles under the elevated highway, the local air exchange rate in the domain tends to be improved. Using these indices, the urban ventilation efficiencies between different urban areas can be compared easily.

THE CHANGE IN SURFACE CONVERSION AND DISCOLORATION IN DENTAL RESTORATIVE COMPOSITE RESIN UNDER DIFFERENT POLISHING METHODS; THE CORRELATION BETWEEN SURFACE CONVERSION AND SURFACE DISCOLORATION (수복용복합레진의 표면처리방법에 따른 표면중합률 및 변색정도의 변화와 그 상관관계에 대한 연구)

  • Park, Sung-Ho;Noh, Byung-Duk;Kim, Mo-Ran;Ahn, Hyun-Jung
    • Restorative Dentistry and Endodontics
    • /
    • v.25 no.3
    • /
    • pp.482-486
    • /
    • 2000
  • The purpose of the present study was first, to evaluate the relationship between composite surface conversion and surface discoloration, second, to know if there was difference in surface discoloration between celluloid-strip-finished composite surface and polished surface. In addition, the discoloration of composite surface was also evaluated with visual inspection or digital camera with high resolution monitor, Z100, Tetric Ceram, Spectrum, and Aelitfil were used. The composite surfaces were celluloid-strip finished (group 1), polished (group 2), celluloid-strip finished under nitrogen gas purging (group 3) or only light cured without finishing or polishing under nitrogen gas purging (group 4). The microhardness of each samples were also measured in each group. The samples of each group were also divided into 4 subgroup whether they were immediately placed in disclosing solution (0.2% Elythrosin, pH 7.0) (subgroup1), 1 day after light curing(subgroup 2), 3day after light curing(subgroup 3) or 7 day after light curing(subgroup 4). The computer controlled spectrophotometer was used to determine CIELAB coordinates ($L^*$, $a^*$, $b^*$). The amounts of color difference were compared. The results were as follows; 1. There was no difference in discoloration between celluloid strip finished composite surface and polished surface. 2. The samples discolored more when they were placed in disclosing solution immediately after polymerization than other groups. 3. When the samples were light cured under nitrogen gas purging and without polishing process, they discolored more than other groups even though they showed higher micro hardness. 4. With visual inspection or digital camera, only a limited information was available in detecting composite surface discoloration.

  • PDF

An experimental study on the performance improvement of dead-end type PEMFC with pulsating effect (맥동 효과를 이용한 dead-end type 연료전지의 성능향상에 대한 실험적 연구)

  • Choi, Jong-Won;Seo, Jeong-Hoon;Hwang, Yong-Sheen;Lee, Dae-Heung;Cha, Suk-Won;Kim, Min-Soo
    • Proceedings of the SAREK Conference
    • /
    • 2008.11a
    • /
    • pp.567-571
    • /
    • 2008
  • PEM Fuel Cell operation mode can be classified into dead-end mode or open mode by whether the outlet port is blocked or not. Generally, dead-end type fuel cell has some merits on the pressure drop and system efficiency because it can generate more power than the open type fuel cell due to high operating pressure condition. However, the periodic purging process should be done for removing water which is formed as product of a reaction in the gas diffusion layer. In this study, cathode side dead-end type operation has been conducted. Moreover, pulsating flow generator at the outlet of cathode side has been suggested for increasing the period to purge the formed water because the pulsating flow can make formed water scattered uniformly over the whole channel. As a result, the purging period with pulsation increased by 1.5-2 times longer than that without pulsating.

  • PDF