Sensitivity Analysis of the Optical System for UV-IR Space Telescope

  • Kim, Sanghyuk;Chang, Seunghyuk;Pak, Soojong;Jeong, Byeongjoon;Kim, Geon Hee;Hammar, Arvid
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.40 no.2
    • /
    • pp.56.4-57
    • /
    • 2015
  • We present the optical design and a sensitivity analysis for a wide field of view (FOV) instrument operating at UV and IR wavelengths. The ongoing investigation is performed in collaboration with Omnisys Instruments (Sweden) and focuses on a telluric-limb-viewing instrument that will fly in a low Earth orbit to study mesospheric wave structures over a wide range of horizontal scales in the altitude range 80 - 100 km. The instrument has six wavelength channels which consist of 4 channels of IR and 2 of UV. We are proposing an optical design based on three mirror aplanatic off-axis reflective system. The entrance pupil diameter and effective focal length are 45 mm and 270 mm, respectively. The FOV is $5.5^{\circ}{\times}1^{\circ}$ and the secondary mirror is set for stop. The optical specification is required to have an encircled energy of at least 80 % within a diameter of 21 um. We performed sensitivity analysis for the longest wavelength of 772 nm in consideration of the diffraction limit of system. The results show that tolerance limits for positions and angles of the mirrors are not very sensitive compared with typical error budgets of manufacturing and assembling process. The secondary mirror has the most sensitive tolerance for surface figure of 250 nm in root-mean-square.

  • PDF

Mathematical Expression of Eye Movement Using Rotation Matrix (Rotation Matrix를 이용한 안구운동의 수학적 표현)

  • Kim, YongGeun
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.4 no.2
    • /
    • pp.51-55
    • /
    • 1999
  • The eye movement of the eyeball's center of a rotation can represent with the rotation matrix $R_x$, $R_y$, $R_z$ due to a coordinate axis rotation transformation of Cartesian coordinate, and describes of an abduction, an adduction, an elevation, a depression, an intorsion, an extorsion in principle rotation six forms of the eye. The eye movement from primary eye position to tertiary eye position could be composed with the rotation matrix combination, and by the primary rotation of six and the secondary rotation of eight, could be represented with the extrocular muscle of six. The position of the cornea vertex point or pupil point due to the eye movement can describe to transform the rotation matrix of the cartesian coordinate to spherical coordinate$(r,{\theta},{\phi})$.

  • PDF

Pupil Center Detection Method using Boundary Distortion Correction (경계선 왜곡 보정을 통한 동공중심 검출 방법)

  • Lee, Injae;Cho, Chul Woo;Lee, Hyeon Chang;Lee, Heekyung;Park, Kang Ryoung;Cha, Jihun
    • Proceedings of the Korean Society of Broadcast Engineers Conference
    • /
    • 2013.06a
    • /
    • pp.70-72
    • /
    • 2013
  • 시선추적 인터페이스는 다른 감각기관에 비해 빠른 반응속도를 보이므로 효과적인 인터랙션 수단으로 활용가능하며, 이를 통해 사용자 경험을 향상시킬 수 있다. 따라서 시선추적 기술은 장애인 안구마우스, 운전자 시선정보 분석, 광고 효과 모니터링, 차세대 게임 등 다양한 분야에 활용될 수 있다. 본 논문에서는 시선추적 인터페이스의 정확도를 향상시키기 위한 기술을 소개한다. 실제 사용자를 대상으로 시선추적을 수행할 때 눈꺼풀로 인한 동공 가림 현상이 자주 발생하며, 각막반사광으로 인한 동공 경계 왜곡 현상이 발생하기도 한다. 이로 인해 동공 중심이 왜곡되어 시선위치에 오류가 발생한다. 이와 같은 문제점을 개선하기 위해 눈꺼풀 및 각막반사광으로 인한 왜곡 현상을 보정하여 동공 중심을 검출하는 방법을 제안한다.

  • PDF

Optical Design of the DOTIFS Spectrograph

  • Chung, Haeun;Ramaprakash, A.N.
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.39 no.2
    • /
    • pp.100.2-100.2
    • /
    • 2014
  • The DOTIFS is a new multi-object Integral Field Spectrograph (IFS) planned to be designed and built by the Inter-University Center for Astronomy and Astrophysics, Pune, India, (IUCAA) for cassegrain side port of the 3.6m Devasthal Optical Telescope (DOT) being constructed by the Aryabhatta Research Institute of Observational Sciences, Nainital. (ARIES) It is a multi-integral field unit (IFU) spectrograph which has 370-740nm wavelength coverage with spectral resolution R~1200-2400. Sixteen IFUs with microlens arrays and fibers can be deployed on 8 arcmin field. Each IFU has $8.7^{{\prime}{\prime}}{\times}7.4^{{\prime}{\prime}}$ field of view with 144 spaxel elements. 2304 fibers coming from IFUs are dispersed by eight identical spectrographs with all refractive and all spherical optics. In this work, we show optical design of the DOTIFS spectrograph. Expected performance and result of tolerance and thermal analysis are also shown. The optics is comprised of f=520mm collimator, broadband filter, dispersion element and f=195mm camera. Pupil size is determined as 130mm from spectral resolution and budget requirements. To maintain good transmission down to 370nm, calcium fluoride elements and high transmission optical glasses have been used. Volume Phase Holographic grating is selected as a dispersion element to maximize the grating efficiency and to minimize the size of the optics. Detailed optics design report had been documented. The design was finalized through optical design review and now ready for order optics.

  • PDF

A study on Iris Recognition using Wavelet Transformation and Nonlinear Function

  • Hur Jung-Youn;Truong Le Xuan;Lee Sang-Kyu
    • Journal of the Korean Institute of Intelligent Systems
    • /
    • v.15 no.3
    • /
    • pp.357-362
    • /
    • 2005
  • Iris recognition system is the one of the most reliable biometries recognition system. An algorithm is proposed to determine the localized iris from the iris image received from iris input camera in client. For the first step, the algorithm determines the center of pupil. For the second step, the algorithm determines the outer boundary of the iris and the pupillary boundary. The localized iris area is transformed into polar coordinates. After performing three times Wavelet transformation, normalization was done using a sigmoid function. The converting binary process performs normalized value of pixel from 0 to 255 to be binary value, and then the converting binary process is compared pairs of two adjacent pixels. The binary code of the iris is transmitted to the server by the network. In the server, the comparing process compares the binary value of presented iris to the reference value in the database. The process of recognition or rejection is dependent on the value of Hamming Distance. After matching the binary value of presented iris with the database stored in the server, the result is transmitted to the client.

An Optical Design of Off-axis Four-mirror-anastigmatic Telescope for Remote Sensing

  • Li, Xing Long;Xu, Min;Ren, Xian Dong;Pei, Yun Tian
    • Journal of the Optical Society of Korea
    • /
    • v.16 no.3
    • /
    • pp.243-246
    • /
    • 2012
  • An off-axis four-mirror-anastigmatic telescope is presented here which is composed of two aspheric surfaces and two spherical surfaces. The entrance pupil diameter is 290 mm and the stop is located at the primary mirror. The effective focal length is 900 mm. The strip field of view for the telescope is $15^{\circ}{\times}0.2^{\circ}$ and if the telescope is launched into an orbit about 400 km altitude, the observed range width will be more than 105 km within a scene without any other auxiliary scanning instrument. The spectral range can be as wide as from visual wave band to infrared wave band in the mirror system. This telescope can be used for environmental monitoring with different detectors whose pixel is adapted to the optical resolution. In this paper, the spectral range is chosen as 3.0 -5.0 ${\mu}m$, and center distance of the pixel is 30 ${\mu}m$. And the image quality is near the diffraction limit.

Optical Design of a Snapshot Nonmydriatic Fundus-imaging Spectrometer Based on the Eye Model

  • Zhao, Xuehui;Chang, Jun;Zhang, Wenchao;Wang, Dajiang;Chen, Weilin;Cao, Jiajing
    • Current Optics and Photonics
    • /
    • v.6 no.2
    • /
    • pp.151-160
    • /
    • 2022
  • Fundus images can reflect ocular diseases and systemic diseases such as glaucoma, diabetes mellitus, and hypertension. Thus, research on fundus-detection equipment is of great importance. The fundus camera has been widely used as a kind of noninvasive detection equipment. Most existing devices can only obtain two-dimensional (2D) retinal-image information, yet the fundus of the human eye also has spectral characteristics. The fundus has many pigments, and their different distributions in the eye lead to dissimilar tissue penetration for light waves, which can reflect the corresponding fundus structure. To obtain more abundant information and improve the detection level of equipment, a snapshot nonmydriatic fundus imaging spectral system, including fundus-imaging spectrometer and illumination system, is studied in this paper. The system uses a microlens array to realize snapshot technology; information can be obtained from only a single exposure. The system does not need to dilate the pupil. Hence, the operation is simple, which reduces its influence on the detected object. The system works in the visible and near-infrared bands (550-800 nm), with a volume less than 400 mm × 120 mm × 75 mm and a spectral resolution better than 6 nm.

Optical Design and Tolerance Analysis for UVO-Multiband Polarizing Imager System

  • Han, Jimin;Chang, Seunghyuk;Park, Woojin;Lee, Sunwoo;Ahn, Hojae;Kim, Geon Hee;Lee, Dae-Hee;Pak, Soojong
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.45 no.1
    • /
    • pp.68.2-68.2
    • /
    • 2020
  • UVO-Multiband Polarizing Imager System (UVOMPIS) is an ultraviolet to visible light multi-wavelength polarization/imaging system for Compact Advanced Satellite. We developed Linear Astigmatism Free-Three Mirror System (LAF-TMS) D200F2 as an optical system of UVOMPIS which has an entrance pupil diameter of 200 mm, a focal ratio of 2, a field of view of 2° × 4°. LAF-TMS is a confocal off-axis reflecting telescope system that removes linear astigmatism, and its all mirrors (M1, M2, M3) are optimized with the freeform surface to reduce high-order aberrations. Through the sensitivity analysis and Monte-Carlo simulation as the tolerance analysis, we can confirm the feasibility of the system, relatively sensitive parameters (tilt, decenter, despace, surface RMS error), and considerations for optomechanical design. From the sensitivity analysis, we can discover the relatively sensitive optical alignment parameters to a single perturbation. Further more, in the monte-carlo simulation, we investigate the minimum tolerance budget satisfying the required optical performance and whether the tolerance range is satisfied within manufacturing error.

  • PDF

A Study on Iris Recognition by Iris Feature Extraction from Polar Coordinate Circular Iris Region (극 좌표계 원형 홍채영상에서의 특징 검출에 의한 홍채인식 연구)

  • Jeong, Dae-Sik;Park, Kang-Ryoung
    • Journal of the Institute of Electronics Engineers of Korea SP
    • /
    • v.44 no.3
    • /
    • pp.48-60
    • /
    • 2007
  • In previous researches for iris feature extraction, they transform a original iris image into rectangular one by stretching and interpolation, which causes the distortion of iris patterns. Consequently, it reduce iris recognition accuracy. So we are propose the method that extracts iris feature by using polar coordinates without distortion of iris patterns. Our proposed method has three strengths compared with previous researches. First, we extract iris feature directly from polar coordinate circular iris image. Though it requires a little more processing time, there is no degradation of accuracy for iris recognition and we compares the recognition performance of polar coordinate to rectangular type using by Hamming Distance, Cosine Distance and Euclidean Distance. Second, in general, the center position of pupil is different from that of iris due to camera angle, head position and gaze direction of user. So, we propose the method of iris feature detection based on polar coordinate circular iris region, which uses pupil and iris position and radius at the same time. Third, we overcome override point from iris patterns by using polar coordinates circular method. each overlapped point would be extracted from the same position of iris region. To overcome such problem, we modify Gabor filter's size and frequency on first track in order to consider low frequency iris patterns caused by overlapped points. Experimental results showed that EER is 0.29%, d' is 5,9 and EER is 0.16%, d' is 6,4 in case of using conventional rectangular image and proposed method, respectively.

The Upgrade of Sasangin Classification System by the Morphologic Study of Head and Face : Facial Differences on Sex and Age (사상체질진단 두면부 분석프로그램의 Upgrade 연구 : 성별.연령별 특징)

  • Seok, Jae-Hwa;Yoon, Jong-Hyun;Lee, Jun-Hee;Hwang, Min-Woo;Cho, Yong-Jin;Kho, Byung-Hee;Lee, Eui-Ju;Song, Il-Byung
    • Journal of Sasang Constitutional Medicine
    • /
    • v.19 no.3
    • /
    • pp.30-50
    • /
    • 2007
  • 1. Objectives Facial features are the important personal characteristics. As a study of all the standardization research about the morphology of face and head, this study was carried out to find the differences according to sex, age. 2. Methods We have collected 1140 cases of patients of the Sasang constitutional Department of Kyung-Hee Medical Center and Kangnam Kyung-Hee Oriental Hospital. we took pictures their frontal view, lateral view of face and measured height, breaths and projected length of face with Face Features Measurement Program(FFMP) and analyzed shape differences of face according to sex, age. 3. Results We got the morphologic characteristics of face according to sex, age. And we will upgrade the Sasangin Classification System by this Morphologic study of Head and Face. 4. Conclusions 1) The morphologic characteristics of face according to sex (1) A man's head is longer and wider than a woman's in most measurement. (2) A woman's eye is bigger in height than man's. (3) A woman's face is looked full-filled than man's. (4) A man's polion is higher than pupil but a woman's polion is lower than pupil. 2) The morphologic characteristics of face according to age (1) Young age's forehead is longer and higher than old age's. (2) Young age's eyebrow is wider than old age's (3) Young age's eye is bigger in height than old age's (4) Old age's nose is longer, wider and lower than young age's (5) Old age's ear is longer than young age's (6) Old age's bigonial breath is wider than young age's (7) Old age's low face is extinguished than you age's

  • PDF