A Study on the Determination Method of Pumpin Rates in Tube Wells for Irrigation (관개용 관정의 가채빙량 추정에 관한 연구)

  • 구자웅;류한열
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.18 no.4
    • /
    • pp.4209-4217
    • /
    • 1976
  • The purpose of this thesis is to search for the determination method of pumping rates in the existing tube wells for irrigation. Pumping tests were carried out for the twelve test tube wells which were selected in the provinces of Kyounggi, Kangwon, Chungbuk and Chungnam. The depths, static water levels, pumping levels, drawdowns and yields of tube wells were measured in the pumping tests, and a centrifugal pump with 3 inches diameter, a 5 HP motor and a 90$^{\circ}$ V-notch were used in the pumping tests. The average coefficient of transmissibility calculated by Chow's and Jacob's methods is 0.0336 square meter per second, and the average pumping rate calculated by Thiem's, Smreker's, Brinkhaus' and Theis' formulae, is 919 cubic meter per day, Therefore, the ground water storage in the test areas is comparatively abundant. Correlation between pumping rates and depths of tube wells is not in existence. Also, correlation between pumping rates and the thickness of aquifer is not found in this experiment. This shows that the depths of some tube wells are deep and their thicknesses of aquifer are thick, but their ground water storages are poor, and that the depths of some tube wells are shallow and their thicknesses of aquifer are thin, but their ground water storages are abundant. It seems that the test tube wells are influenced by the peculiar characteristics that the ground water in the test areas is free ground water in alluvium layer closely related with surface water. As drawdown increases, pumping rate decreases, and as the coefficient of transmissibility increases, pumping rate also increases. Namely, there are negative correlation between pumping rate and drawdown, and positive correlation between pumping rate and the coefficient of transmissibility. Judging from the results of the pumping tests in these tests areas, the pumping rate calculated by the formula, {{{{ { Q}_{m } =Q { ( { { S}_{ m} } over { TRIANGLE S } )}^{ { 2} over {3 } } }}}} used traditionally, is likely to be higher than real pumping rates. The formula, {{{{ { Q}_{m } =Q { { H}^{ 2} } over { (2H- TRIANGLE S) TRIANGLE S} }}}} derived from Thiem's theory, is looked upon as the reasonable one to detemine pumping rates in the existing tube wells for irrigation.

  • PDF

Determination of the Optimal Strategy for Pump-And-Treat Method

  • Ko, Nak-Youl;Lee, Kang-Kun
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 2001.09a
    • /
    • pp.204-207
    • /
    • 2001
  • An optimization process for the design of groundwater remediation is developed by simultaneously considering the well location and the pumping rate. This process uses two independent models: simulation and optimization model. Groundwater flow and contaminant transport are simulated with MODFLOW and MT3D in simulation model. In optimization model, the location and pumping rate of each well are determined and evaluated by the genetic algorithm. In a homogeneous and symmetric domain, the developed model is tested using sequential pairs for pumping rate of each well, and the model gives more improved result than the model using sequential pairs. In application cases, the suggested optimal design shows that the main location of wells is on the centerline of contaminate distribution. The resulting optimal design also shows that the well with maximum pumping rate is replaced with the further one from the contaminant source along flow direction and that the optimal pumping rate declines when more cleanup time is given. But the optimal pumping rate is not linearly proportional to the cleanup time and the minimum total pumping volume does not coincide with the optimal pumping rate.

  • PDF

Optimal Pumping Rate of a Water Well at Imgokri, Sangju City (상주시 임곡리 굴착공의 적정양수량 결정)

  • Cho, Byong-Wook;Yun, Uk;Moon, Sang-Ho;Lee, Byeong-Dae;Cho, Soo-Young;Kim, YongCheol;Hwang, Seho;Shin, Jehyun;Ha, Kyoochul
    • The Journal of Engineering Geology
    • /
    • v.27 no.3
    • /
    • pp.255-265
    • /
    • 2017
  • We have determined the optimal pumping rate of the PW-2 water well (depth=100 m) at Imgokri, Sangju City. Cutting analysis and geophysical logging data reveal water-producing horizons at 26.1-26.5, 28.0-30.0, 33, 58, and 71 m. For pumping rates of 40, 55, 70, 90, and $132m^3/d$ over 70 days, the estimated drawdown from the PW-2 well was 6.48, 11.56, 18.07, 28.99 and 60.26 m, respectively. During a constant-rate pumping test at a rate of $117m^3/d$, the cone of depression intersected an impermeable boundary after 120-150 min of pumping. Therefore, we consider the critical pumping rate for well PW-2 to be $90m^3/d$. After pumping at $90m^3/d$ for 70 days, the calculated drawdown was 28.82-31.27 m. We suggest an optimal pumping rate for well PW-2 of $70-90m^3/d$, as the optimal pumping rate should be similar to the critical pumping rate. Sharp increases in the slope of the time-drawdown relationship, dissolved oxygen concentrations, and oxidation-reduction potential during the constant-rate pumping test indicate the limited development of bedrock aquifers around PW-2.

Characteristics of Ground Water Capture Zone according to Pumping Rate (지하수 양수량에 따른 지하수유동 및 포획구간 특성 변화)

  • Ahn, Seung-Seop;Park, Dong-Il;Oh, Young-Hun
    • Journal of Environmental Science International
    • /
    • v.22 no.7
    • /
    • pp.895-903
    • /
    • 2013
  • This study analyzed on characteristics of the ground-water capture zone in coastal areas and mid-mountainous area according to pumping rate. For this study, it targeted Jejudo island where is the volcanic island. To analyze, MODFLOW model and MODPATH model, which are the ground-water flow analysis models, were used. As a result of research, the following conclusions could be obtained. As a result of analyzing influence of a change in pumping time upon length of capture zone, the length of capture zone in coastal area was indicated to be greater in the changing ratio compared to the length of capture zone in mid-mountainous area. Next, in the coastal area, the pumping rate and the capture-zone length are changing similarly. However, in mid-mountainous area, the length of capture zone was indicated to grow when the pumping rate comes to exceed 1,500m3/day. As a result of analyzing influence of a change in pumping time upon capture area, the tendency of a change in the area was indicated similarly in coastal areas and mid-mountainous area. Especially, it could be known that the larger pumping rate leads to the more definite increase in tendency to a change in capture area. Based on this study, it was allowed to be possibly used in the suitable pumping rate in coastal areas and mid-mountainous area of the volcano island in the future. A follow-up research is judged to necessarily analyze the influence of tubular-well group upon capture zone by additionally analyzing a change in capture zone targeting the concentrated tubular well.

Quantity Evaluation of Hot Spring at Onyang Spa Area (온양온천지구에서의 온천수 수량평가)

  • Lee, Chol-Woo
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2006.06a
    • /
    • pp.438-441
    • /
    • 2006
  • The groundwater level was originally above the surface at the Onyang spa area. However, it is now 98-138m depth below the surface deu to the artificial pumping from boreholes. The fluctuations of the piezometric head were observed in 4 boreholes. Transmissivity estimated from the pumping rate and the drawdown is about $577.51 m^2/day$ The transmissivity of Onyang spa area is much larger than common values of fractured aqui for the drawdown of the piezometric head by artificial pumping is widely spreaded out in that area. The drawdown related to each pumping rate was analyzed and the formula between drawdown and pumping rate was made by a regression analysis. The formula can be applied for the condition of enough groundwater flowing into the Onyang spa area

  • PDF

A Study on Pump and Treat Design through Evaluation of Radius of Influence (영향반경을 이용한 양수처리법 설계에 대한 연구)

  • Kim, Jeong-Woo;Lee, Kang-Kun
    • Journal of Soil and Groundwater Environment
    • /
    • v.19 no.3
    • /
    • pp.1-14
    • /
    • 2014
  • It is necessary to decide the pumping rate and pumping well location together with the capture zone in order to determine an appropriate groundwater remediation strategy to manage the contaminated groundwater. The relationship between the capture zone and the drawdown radius of influence ($ROI_s$) was considered. $ROI_{cs}$ is defined as the distance where the criteria of drawdown is cs meter from pumping well in this paper. A method to decide the required pumping rate for the remediation of contaminated groundwater in order to create appropriate $ROI_{cs}$ is suggested by using the Theis equation (1935) and Cooper-Jacob equation (1946). It was shown in this study that $ROI_{cs}$ is in proportion to the pumping rate and the criteria of drawdown, which decides $ROI_{cs}$, is inversely proportional to Ti value (transmissivity ${\times}$ hydraulic gradient). The pumping rate which creates the required $ROI_{cs}$ could be planned through the relationship between the $ROI_{cs}$ and pumping rates ($ROI_{cs}$-Q curve) of the field sites 1, 2 and 3. If the drawdown is investigated along with Ti value and pumping rate at a specific site where pump and treat remediation is planned, it is expected that the required criteria of drawdown can be evaluated by using the relationship between the cs and Ti (cs-Ti curve).

Correlations between Pumping Rate to Irrigated Area and Rainfall Amount in a Paddy Field (논관개 양수량의 관개면적과 강수량과의 관계)

  • Lee, Sung-Hee;Kim, Tai-Cheol
    • Proceedings of the Korean Society of Agricultural Engineers Conference
    • /
    • 2001.10a
    • /
    • pp.89-92
    • /
    • 2001
  • This study was to analyse the correlations between pumping rate to irrigated area and rainfall amount in the Geum river basins. A total of 84 pumping stations and field data from the paddy of 28,772 ha were introduced to the analysis. The results showed that the pumping volume was highly correlated to the rainfall during the irrigation period and irrigated area. But, it was difficult to determine the exact correlation factors, because of the lack of data like the efficiency of water in the paddy field.

  • PDF

Prediction of changes in the pumping speed characteristics of dry pumps with the geometry of the conduit

  • Sunmin Song;Jun Oh Kim;Sang-Woo Kang;Won Chegal;Jae-Soo Shin;Sung-Kyu Lim
    • Journal of the Korean Physical Society
    • /
    • v.80
    • /
    • pp.337-346
    • /
    • 2022
  • In this study, we investigated whether changes in the pumping speed characteristics of dry pumps due to the conduit can be predicted through simulation. The intrinsic pumping speed was measured in the dry pump characteristic evaluation system of the Korea Research Institute of Standards and Science, and the pumping speed affected by the conduit was measured using the plasma enhanced chemical vapor deposition (PECVD) equipment of the National NanoFab Center. Change in the pumping speed were predicted using conductance calculation equations and commercial vacuum-system simulation program, VacTran. A comparison of the results from the two approaches showed that the error rate was within ± 6.5%, confirming the reliability of the prediction. The simulation result was compared with the measured effective pumping speed, and it was confirmed that the error rate was within ± 10%, except in a specific part where the error rate was up to ± 40%. It is considered that the high error rate in some areas is as a result of automatically adjusting the rotation speed of the motor according to the power consumption of the inverter. However, a high simulation accuracy was obtained, demonstrating that the pumping speed characteristics can be predicted through simulation. This has potential application in the design of a vacuum system.

Impacts of Seasonal Pumping on Stream Depletion (계절양수가 하천건천화에 미치는 영향)

  • Lee, Hyeonju;Koo, Min-Ho;Lim, Jinsil;Yoo, Byung-Ho;Kim, Yongcheol
    • Journal of Soil and Groundwater Environment
    • /
    • v.21 no.1
    • /
    • pp.61-71
    • /
    • 2016
  • Visual MODFLOW was used for quantifying stream-aquifer interactions caused by seasonal groundwater pumping. A hypothetical conceptual model was assumed to represent a stream-aquifer system commonly found in Korea. The model considered a two-layered aquifer with the upper alluvium and the lower bedrock and a stream showing seasonal water level fluctuations. Our results show that seasonal variation of the stream depletion rate (SDR) as well as the groundwater depletion depends on the stream depletion factor (SDF), which is determined by aquifer parameters and the distance from the pumping well to the stream. For pumping wells with large SDF, groundwater was considerably depleted for a long time of years and the streamflow decreased throughout the whole year. The impacts of return flow were also examined by recalculating SDR with an assumed ratio of immediate irrigation return flow to the stream. Return flow over 50% of pumping rate could increase the streamflow during the period of seasonal pumping. The model also showed that SDR was affected by both the conductance between the aquifer and the stream bed and screen depths of the pumping well. Our results can be used for preliminary assessment of water budget analysis aimed to plan an integrated management of water resources in riparian areas threatened by heavy pumping.