Quantity Evaluation of Hot Spring at Onyang Spa Area

온양온천지구에서의 온천수 수량평가

  • 이철우 (한국지질자원연구원 지열자원연구실)
  • Published : 2006.06.22

Abstract

The groundwater level was originally above the surface at the Onyang spa area. However, it is now 98-138m depth below the surface deu to the artificial pumping from boreholes. The fluctuations of the piezometric head were observed in 4 boreholes. Transmissivity estimated from the pumping rate and the drawdown is about $577.51 m^2/day$ The transmissivity of Onyang spa area is much larger than common values of fractured aqui for the drawdown of the piezometric head by artificial pumping is widely spreaded out in that area. The drawdown related to each pumping rate was analyzed and the formula between drawdown and pumping rate was made by a regression analysis. The formula can be applied for the condition of enough groundwater flowing into the Onyang spa area

Keywords