• Title/Summary/Keyword: pumping volume

Search Result 108, Processing Time 0.034 seconds

An Estimation on Area Error For Surface Roughness Advancement of Rapid Prototype by FDM (FDM에서 단면오차법을 이용한 표면예측)

  • 전재억;김수광;황양오;박후명;하만경
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2003.06a
    • /
    • pp.1869-1872
    • /
    • 2003
  • As SLA(Sterealithography), SLS(Selective Laser Sintering), LOM(Laminated Object Manufacturing), FDM(Fused Deposition Modeling) etc. The FDM system the heart of a study and is developed by Stratasys co. ltd, in US., is small and cheap R.P. The material filament is heated until the material reaches a near-liquid state, it is pumped through a nozzle and become hand with a shape required, and this nozzle move pumping on the previously deposited material. Such FDM system that choice deposition type with X-Y plouter obtain in the thin continue layer by decreasing amount of extrusion or to central the injection amount when the head slow down at the corner, but in the process that fusion wax or resin become hand, deformation occur and it will affect the shape accuracy and the surface roughness. Such effect will depreciate quality and reliability of the product. Therefore, when the product made in actuality, the fundamental study on the basis geometry(surface, volume, line, angle) must be preceded and it have been research by many Free Form Fabrication. So, this basic object study purpose to obtain the fundamental geometry data and to enhance the surface roughness of the shape. And an operant can use the data for the progress of the surface roughness. This study research the estimation and application of the prototype surface roughness by adjustment the injection amount. And basie of this research, describe the pattern of prototype surface roughness and also used the result to estimate the surface of prototype.

  • PDF

Experimental studies on stabilization techniques for ground over abandoned subsurface excavations

  • Pal Samir K.
    • 한국지구물리탐사학회:학술대회논문집
    • /
    • 2003.11a
    • /
    • pp.142-149
    • /
    • 2003
  • Blind hydraulic backfilling is a commonly used technique for subsidence control of the strata over unapproachable waterlogged underground excavations. In this investigation model studies on all the three variants of this technique, namely, hydro-pneumatic or air-assisted gravity backfilling, pumped-slurry backfilling and simple gravity backfilling, have been carried out in fully transparent models of the underground excavations. On examination of the filling process, it was revealed that in all the three cases, the basic process of filling occurs by sand transport along one or more meandering channels. The relative influence of sand, water and air flow rates on the area of filling from a single inlet point and the hydraulic pressure loss per unit length were studied in details. In hydro-pneumatic backfilling process, the air bubbles while moving upward through the meandering channels provide an additional buoyant force over and above the available hydraulic head. In this way the area of filling from a single borehole may be quite large even at small flow rates of water. During actual field implementation the injected air, if not released completely from the rise side holes, may cause troubles by way of creating potholes on the surface. The pumped-slurry technique has shown its capability of filling a relatively larger area at faster rate, especially when high-volume, low-pressure method was selected. But simple gravity filling was also found to be equally effective method as slurry pumping, especially when flow rates were high. In the second and third method discussed above, examination of variations of injection pressure was also done and its relation with physical phenomenon was also attempted. Some empirical relationships were also developed using multivariate regression with a view to help the practicing engineers.

  • PDF

Analytical, Numerical, and Experimental Comparison of the Performance of Semicircular Cooling Plates (반원형 구조의 냉각판 성능에 관한 해석적/수치해석적/실험적 비교)

  • Cho, Kee-Hyeon;Kim, Moo-Hwan
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.35 no.12
    • /
    • pp.1325-1333
    • /
    • 2011
  • An analytical, numerical, and experimental comparison of the hydraulic and thermal performance of new vascular channels with semicircular cross sections was conducted. The following conditions were employed in the study: Reynolds number, 30-2000; cooling channels with a volume fraction of the cooling channels, 0.04; and pressure drop, $30-10^5$ Pa. Three flow configurations were considered: first, second, and third constructal structures with diameters optimized for hydraulic operations. To validate the proposed vascular designs by an analytical approach, 3-D numerical analysis was performed. The numerical model was also validated by the experimental data, and the comparison results were in excellent agreement in all cases. The validation study against the experimental data showed that compared to traditional channels, the optimized structure of the cooling plates could significantly enhance heat transfer and decrease pumping power.

A Study on the Practical Operation of a Farm-scale Two-phase Anaerobic Digester for the Treatment of Swine Manure (돼지분뇨 처리를 위한 Farm-scale Two-phase Anaerobic Digester의 실증운영에 관한 연구)

  • 백인규;이상락;안정제;권윤정;맹원재
    • Journal of Animal Environmental Science
    • /
    • v.6 no.2
    • /
    • pp.73-81
    • /
    • 2000
  • A two-phase anaerobic digestion system for the treatment of swine waste was constructed in a commercial hog farm. The digester system was composed of 4 major units; slurry storage pit, acidogenic digester, methanogenic digester and sedimentation pit. A biogas boiler unit was also attached to maintain the digester temperature of 37$^{\circ}C$. Substrate lading was made with 2hr-interval by pumping about 2.1$m^3$ of slurry type swine waste from the slurry pit into the acidogenic digester, which corresponds to hydraulic retention time of 4 days for the acidogenic digester and of 11 days for the methanogenic digester. Digester temperature were well maintained as the set temperature of 37$^{\circ}C$ in the methanogenic digester, while the temperature in the acidogenic digester showed around 34$^{\circ}C$. pH also showed a steady-state results of 7.3 in the acidogenic digester and of 7.6 in the methanogenic digester during the operation period. Average biogas production rate was 0.66$m^3$/$m^3$ digester volume. Reduction rate of total solid and volatile solid were 42.8% and 5.8%, respectively. Total nitrogen and ammonia nitrogen were not reduced during the anaerobic fermentation, however, most of VFAs seemed to be converted to the biogas,. These fermentation performance data may suggest that he newly developed a two-phase anaerobic digester for the swine waste treatment worked so successfully.

  • PDF

A Note on Estimating and Managing Groundwater Reserves (지하수 부존량 평가와 관리에 대한 소고)

  • Lee, Byung Sun;Park, Jong Hwan;Myoung, Wooho;Son, Joohyeong;Lee, Sanghaw;Shim, Gyuseong;Song, Sung-Ho
    • Journal of Soil and Groundwater Environment
    • /
    • v.23 no.6
    • /
    • pp.28-36
    • /
    • 2018
  • This study was conducted to estimate groundwater reserves within a designated depth. Three methods were applied to one representative county in southern Gyeongsang province, South Korea, to estimate the groundwater reserves in the aquifers. Estimated amounts of groundwater reserves in the region ranged from $20.2{\times}10^9m^3$ to $68.7{\times}10^9m^3$ (average $37.9{\times}10^9m^3$). Groundwater recharge obtained with a recharge ratio of 16.6% was $1.1{\times}10^9m^3/year$. Exploitable groundwater with an assumption of decadal-cycle minimal rainfall of 977.0 mm/year was approximated as 72% ($0.8{\times}10^9m^3/year$) of the total replenished water by recharge. The volume of recharge and exploitable water accounted for only 1.1% and 0.8% of groundwater reserves, respectively, which indicates substantial capacity of the reservoir to supply groundwater in an event of unexpected droughts. Nonetheless, each groundwater well should strictly comply with its allocated pumping rate to avoid alluvial groundwater depletion.

A study on the discharge ratio of two solutions with different viscosities using computational fluid analysis (전산유체해석을 이용한 점도가 다른 이종 용액의 토출 비율 연구)

  • Ko, Min-Sung;Wi, Eun-Chan;Yun, Yi-Seob;Kong, Jung-Shik;Lee, Joong-Bae;Kim, Min-Su;Baek, Seung-Yub
    • Design & Manufacturing
    • /
    • v.15 no.4
    • /
    • pp.43-50
    • /
    • 2021
  • Pump-cap is a device for discharging the contents stored inside a container to the outside of the container by a simple operation by a certain amount. In particular, in recent years, as the number of cosmetic products made of functional materials has rapidly increased, the development of convenient containers for functional materials is being actively conducted. Among these, there are a growing number of products that show their efficacy only by mixing two components, so the development of a dual pump cap container is necessary. However, the conventional dual pump cap container has a problem in that it is difficult to implement a quantitative discharge as solutions having different viscosities are used. Therefore, in this study, a discharge port of a dual pump cap that can apply an optimal ratio was designed by analyzing the discharge amount of two components with different viscosities through computational fluid dynamics. Since the discharge amount is affected by the size of the discharge port, the higher the viscosity of the solution, the larger the discharge port should be set. Conversely, the lower the viscosity, the smaller the discharge port should be. Through this, it is possible to dispense a fixed amount of a heterogeneous solution by one pumping, and it is determined that the user's convenience will increase.

Characteristics of Korea's Groundwater use Rights and Suggestions for Groundwater Management Direction (우리나라 지하수 이용권의 특성과 지하수 관리 방향 제언)

  • Ayoung, Jeong;Yunjung, Hyun;Eun-jee, Cha;Jongwon, Kim
    • Journal of Soil and Groundwater Environment
    • /
    • v.28 no.6
    • /
    • pp.1-8
    • /
    • 2023
  • In order to efficiently manage groundwater resources, it is necessary to establish clear definition about the rights to use groundwater because it directly governs the interests of various stakeholders, from users to policy makers. In this paper, we examined the characteristics of Korea's rights to use groundwater through legal precedents, public recognition, laws, and institutional stipulaton. Inclarity about the scope and definition of the right, and the absence of legal basis ruling the exclusion and duration of groundwater use have entailed numerous cases of legal disputes between the parties with incompetible interests. In the perception survey, various responses were obtained from the surveyee regarding the scope of rights perceived by groundwater users, how to respond to groundwater shortages, and opinions about expanding public uses of groundwater. In Korea, the legal authority to use groundwater is governed by different laws while considering groundwater as both private and public property. In foreign countires, the right to use water is separated from property ownership, and it limits the volume and pumping rate of groundwater during a specified period. In order to better manage groundwater resources, it is necessary to come up with a public consensus on the right to use groundwater by considering the opinions of various stakeholders and accomodating them in adminstrative effort in directing groundwater management.

Effects of the Exercise Training on Aging Heart in Rat I. Long Term Endurance Exercise (운동훈련이 흰쥐 노화심근에 미치는 영향 I. 장기간 지구력 운동 훈련)

  • 박원학;이상선;이용덕
    • Biomedical Science Letters
    • /
    • v.2 no.1
    • /
    • pp.71-90
    • /
    • 1996
  • There is considerable current interest in the effect of regular vigorous exercise and in particular endurance-running as a possible measure in improving myocardial function. Some data indicate that the aging heart may actually suffer from vigorous endurance exercise. On the contrary appropriate exercise in aged animals improves myocardial function and aerobic energy metabolism. So far there is relatively little data to indicate that endurance exercise is in fact beneficial in improving myocardial function or damaging to heart of aged animals. The present investigation aimed to study the possible effect of a long range treadmill training program on the heart in aging rats. Male rats aged 3, 10, and 20 months were divided at random into a control (sedentary) and an exercise group. The training group was exercised for 5 days a week on an automated treadmill for 20minutes at 18m/min over a period of 5 months. The exercise regimen of our experiments did not cause any significant changes in the tissues and ultrastructural as com-pared with sedentary age-matched control. Tissues and ultrastructures of myocardial cells in trained group aged 8 months are intact and well organized as well as sedentary control group. Age associated tissue and ultrastructural changes of trained group aged 15 months included : an increase in transformed mitochondria, vacuoles, lysosomes, lipid droplets and early lipofuscin. But the trained heart did not show significant difference in tissue and ultrastructural properties from those of sedentary controls. Endurance-trained group aged 25 months showed significant qualitative tissue and ultrastructural difference as compared with age-matched controls. In addition to those found in 25 months control group, focal necrosis, myofibril fraying, hypercontraction band, seperation of intercalated discs, degenerating nucleus and infiltration of collagenous fiber into myocyte were noted in trained 25 months group. The stereological examination of the mi-crographs disclosed no significant difference in the myoflbril, mitochondrion, sarcotubule and in-terstitium volume density and surface density of mitochondrial cristae and numerical density of mitochondria between trained and control group aged 8 and 15 months. In the trained 25 months group, significant increase in volume density of interstitium, lipofucsin granule were shown as compared to untrained age-matched control. On the other hand, significant decrease in mitochondrion volume density was shown. The myofibril volume density did not differ between trained and control group although trained group showed slight increase. From the data obtained a reduced mitochondria/myofibrils ratio was found in trained rat heart aged 25 months and there was no difference between trained and control rat aged 15 months. But a slight but not significant increase was found in the trained group aged 8 months as compared with same age control group. Such increase in the ratio in young animals is considered to be of great importance to cardiac pumping and adaptability. Whereas such adaptations don't seem to occur in aged heart muscle. This study proposed that repeated endurance exercise do not cause any significant qualitative and quantitative ultrastructural change of heart muscle in young(3months) and adult (10months) suggesting that the heart is able to adapt to the exercise. On the contrary, the repeated endurance exercise stress may actually induce degenerative changes in the aged heart muscle(20months).

  • PDF

The Effect of Decentralized Rainwater Tank System on the Reduction of Peak Runoff - A Case Study at M Village - (빗물저류조의 분산배치에 따른 첨두유출 저감효과 분석 - M 마을 사례 -)

  • Han, Moo-Young;Kum, So-Yoon;Mun, Jung-Soo;Kwak, Dong-Geun
    • Journal of Korea Water Resources Association
    • /
    • v.45 no.1
    • /
    • pp.65-73
    • /
    • 2012
  • Recently climate change and increase of surface runoff caused the urban flooding. Traditional way of dealing with urban flooding has been to increase the sewer capacity or construction of pumping stations, however, it is practically almost impossible because of time, money and traffic problems. Multipurpose DRMS (Decentralized Rainwater Management System) is a new paradigm proposed and recommended by NEMA (National Emergency Management Agency) for both flood control and water conservation. Suwon City has already enacted the ordinance on sound water cycle management by DRMS. In this study, a flood prone area in Suwon is selected and analysis of DRMS has been made using XP-SWMM for different scenarios of RT installation with same total rainwater tank volume and location. Installing one rainwater tank of 3,000$m^3$ can reduce the peak flow rate by 15.5%. Installing six rainwater tanks of 500$m^3$ volume in the area can reduce the peak flow rate by 28%. Three tanks which is concentrated in the middle region can reduce peak rate more than evenly distributed tanks. The method and results found from this study can be used for the design and performance prediction of DRMS at a flood prone area by supplementing the existing sewer system without increase of the sewer capacity.

Development of Neural Network Based Cycle Length Design Model Minimizing Delay for Traffic Responsive Control (실시간 신호제어를 위한 신경망 적용 지체최소화 주기길이 설계모형 개발)

  • Lee, Jung-Youn;Kim, Jin-Tae;Chang, Myung-Soon
    • Journal of Korean Society of Transportation
    • /
    • v.22 no.3 s.74
    • /
    • pp.145-157
    • /
    • 2004
  • The cycle length design model of the Korean traffic responsive signal control systems is devised to vary a cycle length as a response to changes in traffic demand in real time by utilizing parameters specified by a system operator and such field information as degrees of saturation of through phases. Since no explicit guideline is provided to a system operator, the system tends to include ambiguity in terms of the system optimization. In addition, the cycle lengths produced by the existing model have yet been verified if they are comparable to the ones minimizing delay. This paper presents the studies conducted (1) to find shortcomings embedded in the existing model by comparing the cycle lengths produced by the model against the ones minimizing delay and (2) to propose a new direction to design a cycle length minimizing delay and excluding such operator oriented parameters. It was found from the study that the cycle lengths from the existing model fail to minimize delay and promote intersection operational conditions to be unsatisfied when traffic volume is low, due to the feature of the changed target operational volume-to-capacity ratio embedded in the model. The 64 different neural network based cycle length design models were developed based on simulation data surrogating field data. The CORSIM optimal cycle lengths minimizing delay were found through the COST software developed for the study. COST searches for the CORSIM optimal cycle length minimizing delay with a heuristic searching method, a hybrid genetic algorithm. Among 64 models, the best one producing cycle lengths close enough to the optimal was selected through statistical tests. It was found from the verification test that the best model designs a cycle length as similar pattern to the ones minimizing delay. The cycle lengths from the proposed model are comparable to the ones from TRANSYT-7F.