• Title/Summary/Keyword: pumping rates

Search Result 113, Processing Time 0.026 seconds

A Study on the Correlation between Pumping Rates and Influential Factors in Tube Wells for Irrigation (관개용 관정의 양수량과 영향인자들의 상관관계에 관한 연구)

  • 류한열;구자웅
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.16 no.2
    • /
    • pp.3410-3419
    • /
    • 1974
  • The purpose of this study is to find out the correlation between pumping rates and influential factors in the tube wells for irrigation through the analysis of various statistical data of the existing tube wells for irrigation and pumping tests. Statistical data of the existing tube wells for irrigation were collected from the authorities concerned, and pumping tests were carried out for twelve tube wells. The results of this study are summarized as follows: 1. The drilled tube wells are the most useful among various tube wells in securing pumping rates. 2. The enlargement of well diameter or the improvement of pumping equipments is necessary in drilled tube wells with pumping rates more than 806 ㎥/day, and the adjustment of foot valves or the special control of pumping equipments is necessary in tube wells with pumping rates less than 300 ㎥/day. 3. The choking of aquifer and slits can be prevented by removing earth and sand piled in tube wells. 4. The increase of well loss and the destruction of aquifer can be prevented by determining the optimum pumping rates through the step draw down tests. 5. The thickness of gravel packing is rather thin in drilled tube tube wells. 6. High pamping rates can be gained by deepening the depth of tube wells in the place the ground water storage is abundant, the thickness of aquifer is thick. and the depth of tube wells is deep. 7. Higher pumping rates can be obtained by constructing tube wells in the place where the drawdown is little and the coefficient of transmissibility is large.

  • PDF

A Study on the Determination Method of Pumpin Rates in Tube Wells for Irrigation (관개용 관정의 가채빙량 추정에 관한 연구)

  • 구자웅;류한열
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.18 no.4
    • /
    • pp.4209-4217
    • /
    • 1976
  • The purpose of this thesis is to search for the determination method of pumping rates in the existing tube wells for irrigation. Pumping tests were carried out for the twelve test tube wells which were selected in the provinces of Kyounggi, Kangwon, Chungbuk and Chungnam. The depths, static water levels, pumping levels, drawdowns and yields of tube wells were measured in the pumping tests, and a centrifugal pump with 3 inches diameter, a 5 HP motor and a 90$^{\circ}$ V-notch were used in the pumping tests. The average coefficient of transmissibility calculated by Chow's and Jacob's methods is 0.0336 square meter per second, and the average pumping rate calculated by Thiem's, Smreker's, Brinkhaus' and Theis' formulae, is 919 cubic meter per day, Therefore, the ground water storage in the test areas is comparatively abundant. Correlation between pumping rates and depths of tube wells is not in existence. Also, correlation between pumping rates and the thickness of aquifer is not found in this experiment. This shows that the depths of some tube wells are deep and their thicknesses of aquifer are thick, but their ground water storages are poor, and that the depths of some tube wells are shallow and their thicknesses of aquifer are thin, but their ground water storages are abundant. It seems that the test tube wells are influenced by the peculiar characteristics that the ground water in the test areas is free ground water in alluvium layer closely related with surface water. As drawdown increases, pumping rate decreases, and as the coefficient of transmissibility increases, pumping rate also increases. Namely, there are negative correlation between pumping rate and drawdown, and positive correlation between pumping rate and the coefficient of transmissibility. Judging from the results of the pumping tests in these tests areas, the pumping rate calculated by the formula, {{{{ { Q}_{m } =Q { ( { { S}_{ m} } over { TRIANGLE S } )}^{ { 2} over {3 } } }}}} used traditionally, is likely to be higher than real pumping rates. The formula, {{{{ { Q}_{m } =Q { { H}^{ 2} } over { (2H- TRIANGLE S) TRIANGLE S} }}}} derived from Thiem's theory, is looked upon as the reasonable one to detemine pumping rates in the existing tube wells for irrigation.

  • PDF

Surveying the Daily Pumpage for Irrgating Paddy Rice in the Han River Basin (한강수계의 관개용수 일별 양수량 조사)

  • 임상준;박승우;김상민;김현준
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.42 no.1
    • /
    • pp.57-65
    • /
    • 2000
  • The objective of this paper are to present a realistic methodology to estimate the daily water supply rates form irrigation pumping stattions, to validate it with the field data, and to report the daily irrigation pumping rates from the Han river basin. Five-year historical pumping records were collected from seventy-three pumping stations in the Han river basin. And the daily pumping rates were estimated from the electrical consumption records. The pumping patterns from the stations were analyzed and the results were applied to ungauged pumping stations in the basin. The method was appliedto five stations which were field monitored during the irragation periods in 1998. The relative errors between the observed and simulated water pumpage ranged from 1.4 to 7.0 percent. This indicates that the proposed method is valid to apply for estimating the pumping rates for agricultural lands. During 1993 to 1997, the annual average water pumpaging from the Han river and the tributaries were 350 million cubic meter. The annual water supply from the pumping stations varied from 973 to 1.377 mm in depth and the mean was 1,170 mm. The major factor affecting the annual variations was attributed to the rainfall during the growing seasons.

  • PDF

Experiment for the Relation Between Arrangement,Numbers and Pumping Rates of Well (관정의 배열수 및 양수량의 상호관계에 관한 실험)

  • 권무남
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.11 no.3
    • /
    • pp.1707-1718
    • /
    • 1969
  • The purpose of this experiment is to determine the relations between numbers, arrangements and pumping rates of wells. In this experiment, well pipes were vertically set up in an artificial water-bearing sand layer of homogeneous quality. Wells were arranged in different ways and their number was varied in order to observe the variation of pumping rates. Sands were filled in a square tank, $183cm{\times}91.5cm{\times}91.5cm$ so as to secure a water-bearing layer. Water was constantly supplied from a supply tank located at an end of the tank. The number of well pipes was varied from one to four. Well pipes were connected by a horizontal header pipes were connected by a horizontal header pipe located above them and one pump was used. Pumping rates were measured, when they were arranged in longitudinal and lateral directions, They were also arranged in a square and triangle. The main results thus obtained are presented as follows: (1) When well pipes are laid out in a longitudinal line, i. e., in a flow direction, the ratios of pumping rates of one-pipe well and wells 2-, 3- and 4- pipe t, are 1.903, 2.506 and 2.66, respectively. (2) When well pipes are laid out in a lateral line, i.e., in a perpendicular direction to flow, the same ratios as (1) are 1.912, 2.527 and 2.88. (3) When four pipes are laid out in a square and three pipes are laid out in a triangle, pumping rates are deereased, Comparing with the cases when pipes are laid out in a straight line.

  • PDF

Determining Optimal Locations of an Artificial Recharge Well using an Optimization-coupled Groundwater Flow Model (지하수 모델링 기법을 이용한 인공함양정 최적 위치 평가)

  • Lee, Hyeonju;Koo, Min-Ho;Kim, Yongcheol
    • Journal of Soil and Groundwater Environment
    • /
    • v.19 no.3
    • /
    • pp.66-81
    • /
    • 2014
  • A Fortran program was developed to determine the optimal locations of an artificial recharge well. Three objective functions were considered: (1) maximizing the recovery rates, (2) maximizing the injection rates, and (3) minimizing the coefficient of variation of the increased pumping rates. We also suggested a new aggregate objective function which combined the first and the third objective functions. The model results showed that locating the injection well inside the cluster of pumping wells was desirable if either the recovery or the injection rate was taken into account. However, the injection well located outside the cluster evenly increased the pumping rates in existing pumping wells. Therefore, for clustered pumping wells, installing an injection well at the center or the upstream of the pumping wells seems beneficial. For linear arrangement of pumping wells parallel to the constant head boundary, locating the injection well in the upstream was recommended. On the contrary, in case of the linear arrangement perpendicular to the constant head boundary, the injection well installed on both sides of the central part of the pumping wells was preferable.

Evaluation of Pumping Rates for Multiple-Well Systems (군정 시스템의 취수량 평가)

  • Park, Nam-Sik;Kim, Sung-Yun;Kim, Boo-Gil;Kim, Il-Ryong
    • The Journal of Engineering Geology
    • /
    • v.18 no.4
    • /
    • pp.439-446
    • /
    • 2008
  • We have developed a method to evaluate pumping rates from a system of pumping-well family. For a given system actual pumping rates depend on pump characteristics and the sum of the static head and the dynamic head. The static head is the elevation difference between the natural groundwater level and the outlet of the pipeline that connects all the wells. Major components of the dynamic head are groundwater drawdown in the well and pipeline head loss. The dynamic head and the pump characteristics depend on the pumping rates. Actual pumping rates are determined at the intersections of the system total-head curves and the pump characteristic curves. The Newton-Raphson's method is used to solve the nonlinear simultaneous equations. The method is applied to a hypothetical well family. Impacts of various design and operational parameters on the pumping rates are analyzed.

Asymmetric Flows for Porous Silicon Electroosmotic Pumps (다공성 실리콘막을 포함한 전기침투 방식 펌프에서의 비대칭적 인 유동)

  • Kim, Dae-Joong;Santiago, Juan G.
    • 한국전산유체공학회:학술대회논문집
    • /
    • 2008.03b
    • /
    • pp.703-704
    • /
    • 2008
  • We fabricated and tested porous silicon-based electroosmotic pumps. Compared to other pumping media, porous silicon is beneficial for obtaining comparable flow rates with much lowered electric potential, while maintaining enough mechanical properties. We fabricated porous silicon with two sided-reactive etching processes. We found higher flow rate per electric potential (consistent with previous studies) and we also found asymmetric flow rates for different pumping directions. We plan to utilize this asymmetry for AC pumping applications.

  • PDF

Effects of Self-breast Pumping in Primiparous Women after Cesarean Delivery (제왕절개술 초산모의 자가 착유 행위 효과)

  • Yeo, Jung-Hee;Moon, Guil-Nam;Lee, Sun-Ok
    • Women's Health Nursing
    • /
    • v.18 no.2
    • /
    • pp.98-107
    • /
    • 2012
  • Purpose: This study was done to identify the effects of self-breast pumping on breastfeeding rates and, the degree of breast milk fullness among primiparous women giving birth by cesarean section. Methods: The study design was a non-synchronized posttest control group experiment with repeated measures. The participants were 60 women, 31 in the experimental group who used a manual pump 5 times a day after exclusive breastfeeding and 29 in the control group who breastfed exclusively with no other interventions. Results: While self-breast pumping did not improve breastfeeding rates or the degree of breast milk fullness at any of the time points studied, breastfeeding rates continued to remain high till 12 weeks postpartum in both groups. Conclusion: Although some modifications in research methods will be required to identify the effects of breast pumping and exclusive breastfeeding, both these approaches can be used as interventions to improve breastfeeding rates and breast milk quantity.

Quasi-quantitative estimation on backstreaming characteristics of a turbomolecular pump (터보분자펌프 역류특성의 준정량적 평가)

  • 인상렬;박미영
    • Journal of the Korean Vacuum Society
    • /
    • v.10 no.1
    • /
    • pp.1-9
    • /
    • 2001
  • Pumping characteristics of a turbomolecular pump are influenced by interrelations of the down-stream and upstream pumping speeds (transmission probabilityxaperture conductance), and of gas flow rates (pumping speedxentrance pressure) in two directions. The pumping speed, one of the most important items characterized the performance of a pump, is given by dividing the net flow rate, that is, the difference between the counter flow rates by the pressure at the pumping port. The maximum compression ratio is defined as the ratio of the downstream pumping speed to the upstream one. Because these directional characteristics affect each other and are functions of the pressures of both sides, it is difficult to distinguish the relevant factors. However, quasi-quantitative analyses on them can be done if considering carefully the results of measuring the pumping speed and the maximum compression ratio.

  • PDF