• Title/Summary/Keyword: pulses

Search Result 1,607, Processing Time 0.018 seconds

Properties of the Twenty-seven Pulses in DongUiBoGam Based on the Eight Important Pulses (팔요맥을 중심으로 살펴본 『동의보감』 27맥 속성 연구)

  • Lee, Taehyung;Jung, Won-Mo;Go, Byeongho;Park, Hi-Joon;Kim, Namil;Chae, Younbyoung
    • Korean Journal of Acupuncture
    • /
    • v.32 no.4
    • /
    • pp.151-159
    • /
    • 2015
  • Objectives : Pulse diagnosis is considered particularly important among several methods of diagnosis in DongUiBoGam. In spite of its importance, numerous and various pulse descriptions made it difficult to learn and practice pulse diagnosis. In this article, we tried to analyze properties of the twenty-seven pulses from pulse diagnosis cases from DongUiBoGam to enable the practical understanding of pulse diagnosis. Methods : We constituted the four axis according to the eight important pulses. And we analyzed properties of the twenty-seven pulses through the relationship between the four pairs of important pulses and the twenty-seven pulses. To quantify the relevances of important pulses to the twenty-seven pulses, we used the term frequency-inverse document frequency(TF-IDF) method. Results : We could elicit properties of the twenty-seven pulses according to the four axis. Also, we reexamined the categorization of the seven exterior pulses / the eight interior pulses and the similar pulses from DongUiBoGam with the analysis results. Conclusions : We could understand properties of the twenty-seven pulses more specifically with the eight important pulses. And we also could see the relationship among the twenty-seven pulses on each axis. However, the limitation arising from insufficient number of pulse diagnosis cases in this research requires further research with more sources such as other traditional medical records or clinical records in the present time.

Transform-Limited Optical Short Pulse Generation by Compression of Gain-Switched DFB Laser Pulses (DFB 레이저 이득 스위칭과 펄스 압축을 이용한 변환 제한된 초단 광 펄스 발생)

  • 조성대;이창희;신상영;채창준
    • Journal of the Korean Institute of Telematics and Electronics D
    • /
    • v.35D no.6
    • /
    • pp.92-98
    • /
    • 1998
  • The transform limited optical short pulses are generated by compression of pulses from a gain switched distributed feedback laser at 5 GHz repetition rate. The gain-switched pulses have the minimum pulse width of 27 psec with the spectral width of 1.1 nm. Thus the output pulses have a large amount of linear chirp and nonlinear chirp. We suppress the nonlinear chirp by passing the pulses through the optical band pass filter with 3 dB band width of 0.55 nm which is narrower than spectral width of the input pulses and generate 7.1 psec pulses by compressing the output with the dispersion compensating fiber. The pulses have time-bandwidth product of 0.49 which is close to the transform limited gaussian pulse. These pulses can be utilized as optical sources in 40 Gbit/s time division multiplexed optical transmission system.

  • PDF

Multi-Pulse Amplitude and Location Estimation by Maximum-Likelihood Estimation in MPE-LPC Speech Synthesis (MPE-LPC음성합성에서 Maximum- Likelihood Estimation에 의한 Multi-Pulse의 크기와 위치 추정)

  • 이기용;최홍섭;안수길
    • Journal of the Korean Institute of Telematics and Electronics
    • /
    • v.26 no.9
    • /
    • pp.1436-1443
    • /
    • 1989
  • In this paper, we propose a maximum-likelihood estimation(MLE) method to obtain the location and the amplitude of the pulses in MPE( multi-pulse excitation)-LPC speech synthesis using multi-pulses as excitation source. This MLE method computes the value maximizing the likelihood function with respect to unknown parameters(amplitude and position of the pulses) for the observed data sequence. Thus in the case of overlapped pulses, the method is equivalent to Ozawa's crosscorrelation method, resulting in equal amount of computation and sound quality with the cross-correlation method. We show by computer simulation: the multi-pulses obtained by MLE method are(1) pseudo-periodic in pitch in the case of voicde sound, (2) the pulses are random for unvoiced sound, (3) the pulses change from random to periodic in the interval where the original speech signal changes from unvoiced to voiced. Short time power specta of original speech and syunthesized speech obtained by using multi-pulses as excitation source are quite similar to each other at the formants.

  • PDF

On the Design of Orthogonal Pulse-Shape Modulation for UWB Systems Using Hermite Pulses

  • Giuseppe, Thadeu Freitas de Abreu;Mitchell, Craig-John;Kohno, Ryuji
    • Journal of Communications and Networks
    • /
    • v.5 no.4
    • /
    • pp.328-343
    • /
    • 2003
  • Orthogonal pulse-shape modulation using Hermite pulses for ultra-wideband communications is reviewed. Closedform expressions of cross-correlations among Hermite pulses and their corresponding transmit and receive waveforms are provided. These show that the pulses lose orthogonality at the receiver in the presence of differentiating antennas. Using these expressions, an algebraic model is established based on the projections of distorted receive waveforms onto the orthonormal basis given by the set of normalized orthogonal Hermite pulses. Using this new matrix model, a number of pulse-shape modulation schemes are analyzed and a novel orthogonal design is proposed. In the proposed orthogonal design, transmit waveforms are constructed as combinations of elementary Hermites with weighting coefficients derived by employing the Gram-Schmidt (QR) factorization of the differentiating distortion model’s matrix. The design ensures orthogonality of the vectors at the output of the receiver bank of correlators, without requiring compensation for the distortion introduced by the antennas. In addition, a new set of elementary Hermite Pulses is proposed which further enhances the performance of the new design while enabling a simplified hardware implementation.

Statistical Characteristics of the Electromagnetic Pulses Radiated from Intracloud Discharges (운방전에 의해 발생한 전자장 펄스의 통계적 특성)

  • Lee, Bok-Hee;Jeong, Dong-Cheol;Lee, Dong-Moon;Ahn, Chang-Hwan
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.18 no.5
    • /
    • pp.112-117
    • /
    • 2004
  • In this paper, in order to obtain the detailed information about lightning electromagnetic pulses, the electromagnetic pulses radiated from intracloud discharges were measured, and their characteristics and waveform parameters were analyzed statistically. The electromagnetic pulses produced by intracloud discharges are distinctly different with those by lightning return strokes. The zero-crossing times and the full pulse widths of the large bipolar electromagnetic pulses are gradually decreased as the stroke proceeds. Also, the electromagnetic pulses tend to be bipolar, with narrow and fast leader pulses superimposed on the initial half cycle. The mean numbers of leader pulses superimposed on the initial half cycle were 1.61$\pm$0.74 and 1.75$\pm$0.73 for the positive and negative polarities, respectively.

Statistical Characteristics of the Electromagnetic Pulses Radiated from Intracloud Discharges (운방전에 의한 뇌전자장 펄스의 특성)

  • Lee, B.H.;Lee, D.M.;Jeong, D.C.;Lee, S.C.;Ahn, C.H.
    • Proceedings of the KIEE Conference
    • /
    • 2004.07c
    • /
    • pp.1882-1884
    • /
    • 2004
  • In this paper, the waveform parameters of electromagnetic pulses radiated from intracloud discharges were presented. The zero-crossing times and the full pulse widths of the large bipolar electromagnetic pulses due to intracloud discharges are gradually decreased as the stroke proceeds. Also, the electromagnetic pulses tend to be bipolar, with narrow and fast leader pulses superimposed on the initial half cycle. The mean numbers of leader pulses superimposed on the initial half cycle were 1.61${\pm}$0.74 and 1.75${\pm}$0.73 for the positive and negative polarities, respectively.

  • PDF

Using Pulse-Front Tilt to Measure Laser Pulses Less Than 100 Picoseconds in Duration

  • Jeong, Hoon
    • Korean Journal of Optics and Photonics
    • /
    • v.26 no.6
    • /
    • pp.318-321
    • /
    • 2015
  • We demonstrate a frequency-resolved optical grating (FROG) device for measuring the intensity and phase versus time of several-tens-of-picoseconds laser pulses, using a thick nonlinear optical crystal. The huge pulse-front tilt generated by a holographic grating increases the temporal range of the device, which can make a single-shot measurement of laser pulses less than 100 ps in duration. To verify the measurement technique, we generate double pulses using a Michelson interferometer. The measured duration of a single pulse is about 300 fs and the measured maximum delay of two pulses is 60 ps, which implies that the proposed FROG device can measure laser pulses with maximum pulse width of about 120 ps.

Design and Manufacture of a Device for the Recognition of Long Vowels (장모음 인식장치 설계 제작)

  • 구용회
    • Journal of the Korean Institute of Telematics and Electronics T
    • /
    • v.35T no.3
    • /
    • pp.9-14
    • /
    • 1998
  • The speech recognition on long vowels are carried out by electric circuits. A level compressor is able to transform the wave of voice to serial pulses. The obtained pulses have informations to distinguish the vowels. The sampling of the pulses is carried out by the register which picks up a series of serial signals in a pitch of a vowel as an unit. The timing control pulses such as sampling pulses are generated by using peak pulses in the speech wave. The parallel data in the register assign the phonetic symbol by means of the decision making circuit which carries out the IF-THEN rule.

  • PDF

Characterization of Supercontinuum and Ultraviolet Pulses by Using XFROG

  • Tsermaa, Baatarchuluun;Yang, Byung-Kwan;Kim, Myung-Whun;Kim, Jin-Seung
    • Journal of the Optical Society of Korea
    • /
    • v.13 no.1
    • /
    • pp.158-165
    • /
    • 2009
  • We present cross-correlation frequency-resolved optical gating (XFROG) measurements of supercontinuum pulses generated by using a photonic crystal fiber (PCF), and ultraviolet (UV) pulses generated by frequency doubling of infrared ultra-short pulses. Since supercontinuum pulses have broad spectra, XFROG measurement typically requires using an extremely thin nonlinear crystal which has a thickness of sub-ten microns. Instead of using such a thin crystal, we employed a relatively thick crystal which was mounted on a galvanometer in order to achieve a phase-matching over the whole spectral bandwidth of the supercontinuum pulses by a crystal-dithering technique. Experimental results of the retrieved phase and intensity were in fair agreement with the independently measured data.

A Study on the 27 Pulse Patterns of Heo Jun Based on the Theoretical Principle and Analysis of the Seven Exterior Pulses (허준(許浚) <이십칠맥(二十七脈)>에 대한 고찰 - 입론(立論) 원칙과 칠표맥(七表脈) 분석을 중심으로 -)

  • Jang Woo-chang;Yoon Eunkyung;Nanjie;Kim Jin-uk;Kim Hyeon-ki
    • Journal of Korean Medical classics
    • /
    • v.36 no.4
    • /
    • pp.1-24
    • /
    • 2023
  • Objectives : To understand the theoretical principle of the pulse patterns listed in the 27 Pulses chapter in the Donguibogam, to further examine the relationship between the pattern and according disease of each pulse. Based on these findings, the fundamental meaning of Heo's theories and specific characteristics of the seven exterior pulses were understood. Methods : First, the 27 Pulses chapter of Heo Jun and Zhenmaimun chapter of Lichan were compared. Next, the Chandomaekgyeol and the Maijing were compared to determine bibliographical evidence of Heo's integration of pulse patterns. Based on the main references, the relationship between pattern and disease were studied, along with cases where the principles of the 27 pulses were applied in the Maekbeob chapter of the Donguibogam. Results & Conclusions : In the 27 Pulses chapter, Heo undertook the task of integrating the pulse patterns based on the differentiation of the excessive type and deficient type, along with the awareness of the issue of pulse pattern and disease matching. In specific, he organized and integrated the linguistic expressions of pulses in major pulse texts, directly intervening in places that he felt needed additional explanation. In conclusion, we found that the 27 pulses are systematic, rational, and unique in terms of pulse integration.