• Title/Summary/Keyword: pulsed mode

Search Result 172, Processing Time 0.023 seconds

Magnetic Pulsed Compaction of nanostructured Al-Fe-Cr-Ti Powder and wear properties (Al-Fe-Cr-Ti 나노결정 합금분말의 자기펄스 성형 및 마모 특성)

  • Kim, Jun-Ho;Hong, Soon-Jik
    • Proceedings of the Korean Society for Technology of Plasticity Conference
    • /
    • 2008.05a
    • /
    • pp.528-530
    • /
    • 2008
  • The effect of consolidation temperature on the microstructure, density and mechanical properties (especially, wear property) of $Al_{92.5}-Fe_{2.5}-Cr_{2.5}-Ti_{2.5}$ alloy fabricated by gas atomization and magnetic pulsed compaction was investigated. All consolidated alloys consisted of homogeneously distributed fine-grained fcc-Al matrix and intermetallic compounds. Relative higher mechanical properties in the MPCed specimen were attributed to the retention of the nanostructure in consolidated bulk without cracks. The as consolidated bulk by magnetic pulsed compaction showed the enhanced wear properties than that of a general consolidation process. In addition, the wear mechanism and fracture mode of MPCed bulk was discussed.

  • PDF

Magnetic Properties of SmCo Thin Films Grown by Using a Nd-YAG Pulsed Laser Ablation Method (Nd-YAG Pulsed Laser Ablation법으로 제작한 SmCo계 박막의 자기특성)

  • 김상원;양충진
    • Journal of the Korean Magnetics Society
    • /
    • v.10 no.1
    • /
    • pp.30-36
    • /
    • 2000
  • SmCo films were deposited on Si(100) substrate by a Nd-YAG pulsed laser ablation of the targets of Sm$\_$100-x/Co$\_$x/ (73$\leq$x$\leq$93) at the substrate temperature of 600∼700$\^{C}$ and the laser beam energy density of Q switching mode or fixed Q mode. The magnetic properties of the films obtained from the Q switching mode exhibited a 4 $\pi$ Ms of 5200∼7700 Gauss, iHc of 190-250 Oe, and 4$\pi$M$\_$r//4$\pi$M$\_$s/ of 0.4∼0.74, respectively, while the fixed Q mode gave the magnetic properties of corresponding films of a 4$\pi$M$\_$r//4$\pi$M$\_$s/ = 0.32∼0.91 and iHc of 430-6290 Oe, respectively. The fixed Q mode gave the better magnetic properties of the SmCo films which seems to be due to a formation of magnetically hard minor phases in droplet of Sm-rich intermetallics. However, the resultant rough surface of the SmCo films is a problem to be solved by a continued study.

  • PDF

Effects of Pulse Modulations on Particle Growth m Pulsed SiH4 Plasma Chemical Vapor Deposition Process (펄스 SiH4 플라즈마 화학기상증착 공정에서 입자 성장에 대한 펄스 변조의 영향)

  • Kim, Dong-Joo;Kim, Kyo-Seon
    • Journal of Industrial Technology
    • /
    • v.26 no.B
    • /
    • pp.173-181
    • /
    • 2006
  • We analyzed systematically particle growth in the pulsed $SiH_4$ plasmas by a numerical method and investigated the effects of pulse modulations (pulse frequencies, duty ratios) on the particle growth. We considered effects of particle charging on the particle growth by coagulation during plasma-on. During plasma-on ($t_{on}$), the particle size distribution in plasma reactor becomes bimodal (small sized and large sized particles groups). During plasma-off ($t_{off}$), there is a single mode of large sized particles which is widely dispersed in the particle size distribution. During plasma on, the large sized particles grows more quickly by fast coagulation between small and large sized particles than during plasma-off. As the pulse frequency decreases, or as the duty ratio increases, $t_{on}$ increases and the large sized particles grow faster. On the basis of these results, the pulsed plasma process can be a good method to suppress efficiently the generation and growth of particles in $SiH_4$ PCVD process. This systematical analysis can be applied to design a pulsed plasma process for the preparation of high quality thin films.

  • PDF

A Pulsed Mode Operating DC Power Supply Based on Modified Multilevel Converter (Modified 멀티레벨 컨버터 기반 펄스모드 동작 직류전원장치)

  • Ahn J.S.;Nho E.C.;Kim I.D.;Kim H.G.;Chun T.W.
    • Proceedings of the KIPE Conference
    • /
    • 2003.07a
    • /
    • pp.264-268
    • /
    • 2003
  • This paper describes a high voltage high power DC power supply which has the ability of pulsed mode operation. The power supply Is constructed with several series connected power converters based on modified multilevel converters. The modified multilevel converters are suitable for the protection of frequent output short-circuit. The output dc power of the proposed converter can be disconnected from the load within several hundred microseconds at the instant of short-circuit fault. The rising time of the dc load voltage is as small as several hundred microseconds, and there is no overshoot of the do voltage because the dc output capacitors keep undischarged state. Analysis, simulations, and experiments are carried out to Investigate the operation and usefulness of the proposed scheme.

  • PDF

Pulsed Energy Dependent Neutron Transport Theory

  • Minn, Hokee
    • Nuclear Engineering and Technology
    • /
    • v.2 no.4
    • /
    • pp.249-254
    • /
    • 1970
  • A time-energy transient characteristics of pulsed neutron transport problem with an inelastic kernel in the fast domain is solved exactly with a continuous energy transfer operator. A discrete time eigenvalue is found which is asymptotically dominant. The complete solution consists of three parts: a time-energy separable mode which is asymptotically dominant and a non-separable mode which is made up by two parts; a pure energy slowing-down transient and a mixture of time and energy transient which is negligible asymptotically.

  • PDF

The Therapeutic Effects of a Pulsed Nd:YAG Laser on Oral Lesions (구강병소에 대한 펄스형 Nd: YAG 레이저의 치료효과)

  • 신금백
    • Journal of Oral Medicine and Pain
    • /
    • v.22 no.2
    • /
    • pp.309-325
    • /
    • 1997
  • In order to set the lasing variables and evaluate, clinically, the therapeutic effects of a pulsed Nd:YAG laser on oral lesion, the author applied the laser energy from a fiberoptic delivered, free running, pulsed Nd:YAG laser (wavelength 1064nm, Pulse duration 120$\mu$sec, fiber diameter 200$\mu$m/320$\mu$m) to 22 cases of oral soft tissue lesions and 6 cases of oral hard tissue lesions. The obtained results were as follows : 1. The effective excision with contact mode and the effective hemostasis of accompanied bleeding with noncontact mode were occurred by lasing on oral soft tissue lesions with fiber diameter of 320$\mu$m under the variables of 2.0~4.0W and 20~50Hz which were controlled into high power/low pulses for excision, low power/high pulses for hemostasis, low power in granulation tissue and high power in fibrous tissue according to therapeutic goals and tissue conditions. 2. About 50% of decreasing effect on hypersensitivity was occurred by lasing with non-contact and contact mode on cervical abrasion which caused dentinal hypersensitivity with fiber diameter of 320$\mu$m under the variables of 0.7 - 1.0W and 10Hz which were applied 2~3 times with 1 week interval. 3. The effective sterilization of infected root canal and lesion of periapical abscess was occurred by lasing with contact and spiral modes on wall of root canal and periapical abscess with fiber diameter of 200$\mu$m of which the tip was placed about 1mm shorter than root canal length under the variables of 1.OW and 10Hz.

  • PDF

Numerical Study of Three Dimensional Detonation Waves Structure in Highly Unstable Mode. (고불안정 조건에서의 3차원 데토네이션 파면 구조 해석 연구)

  • Cho, Deok-Rae;Won, Su-Hee;Shin, Jae-Ryul;Choi, Jeong-Yeol
    • 한국연소학회:학술대회논문집
    • /
    • 2012.11a
    • /
    • pp.359-362
    • /
    • 2012
  • The results are shown highly unstable mode's detonation dynamics by compared with weakly unstable mode. And we investigate the difference and similar features of 2D and 3D results. By using PSD via FFT, the effects of pre-exponential factor difference and of unstable mode were investigated in this study. The result of PSD is shown pulsed features in weakly unstable mode, but noselike in highly unstable mode. By compared between Sheliren image and overlaid slice image, the irregular feature of detonation waves structure was discussed in highly unstable mode.

  • PDF

Effectiveness of Shortwave Therapy in Management of Knee Osteoarthritis : A Systematic Review and Meta-analysis of Randomized Controlled Trials (무릎 뼈관절염의 단파치료 효과 : 무작위임상시험의 메타분석과 체계적 고찰)

  • Lee, Jae-Hyoung;Cho, Hyuk-Shin;Song, In-Yong
    • The Journal of Korean Physical Therapy
    • /
    • v.26 no.5
    • /
    • pp.331-343
    • /
    • 2014
  • Purpose: The purpose of this study is to assess the effectiveness of short-wave therapy (SWT) for treatment of knee osteoarthritis (OA) as compared to placebo and control, and to assess the question of whether the effects are related to the mode, dosage, and application method. Methods: We searched randomized, placebo-controlled trials using electronic databases. We also manually reviewed sources in order to identify additional relevant studies. Results: Eight studies (597 participants) with OA were included in the meta-analysis. Pulse SWT had a significant effect on pain relief compared with control treatment, while did not favour compared with the placebo group. Pulse SWT had a significant effect on functional improvement compared with control and placebo treatment. Continuous SWT had no effect on pain relief and functional improvement. Capacitive SWT a significant effect on pain relief, functional improvement, and muscle strength. Continuous and capacitive SWT had increased muscle strength significantly. We found no clinical significance of all outcomes except pain and functional improvement in pulsed SWT with low dose. There was no difference in adverse events. None of the participants experienced any serious adverse events. Conclusion: Low dose pulsed SWT provided a short-term clinical benefit for pain relief and functional improvement. Pulsed SWD with low and high dose had effects on pain and function. There seems to be a placebo effect. We found significant effects on pain and function in capacitive SWT. Despite some positive findings, this analysis lacked data on how effectiveness is affected by mode, dosage, and application method of SWT. Further well-designed clinical studies are required in order to confirm the effectiveness of SWT.

Polymer Thin Film of Phthalic Anhydride via Plasma Polymerization (플라즈마 중합에 의한 프탈릭 안하이드라이드 고분자 박막 필름 제조 연구)

  • Kang, Hyun Min;Basarir, Fevzian;Paek, Kwan Yeol;Yoon, Tae-Ho
    • Journal of Adhesion and Interface
    • /
    • v.10 no.1
    • /
    • pp.17-22
    • /
    • 2009
  • Polymer thin films were prepared by radio frequency (RF) plasma polymerization of phthalic anhydride (PA). First, monomer vaporization temperature ($100{\sim}160^{\circ}C$) was optimized by evaluating the thermal properties of thin films using differential scanning calorimeter (DSC) and measuring the root-mean-square (RMS) roughness with atomic force microscope (AFM) at the fixed plasma power of 10 W and time of 5 min in a continuous-wave (CW) mode. Plasma power (5~20 W) was then optimized by measuring the film solubility in solvents such as toluene, acetone, dimethylsulfoxide (DMSO) and 1 methylpyrrolidine (NMP). Next, pulsed mode plasma polymerization was also studied by varying the duty cycle of on-time (5, 20%) under optimized conditions of continuous-wave (CW) mode ($120^{\circ}C$, 10 W) in order to increase the anhydride functional groups. Finally, polymer thin films were characterized by Fourier transform infrared spectroscopy (FT-IR), thermogravimetric analyzer (TGA) and ${\alpha}$-step.

  • PDF