• 제목/요약/키워드: pulsed fiber laser

검색결과 42건 처리시간 0.028초

Pulsed Nd:YAG 레이저로 유발된 백서 설점막 창상의 조직학적 변화-수술칼에 의해 형성된 창상과의 비교 실험 (Histological Changes of the Wound in the Tongue Mucosa of White Rats by Pulsed Nd:YAG Laser - A Comparative Experiment with the Scalpel Incision)

  • 박준상;박미희;박봉수
    • Journal of Oral Medicine and Pain
    • /
    • 제22권1호
    • /
    • pp.125-135
    • /
    • 1997
  • The Author examined the clinical and histological changes on the dorsal tongue mucosa of the adult rats after lasing by pulsed Nd:YAG laser and incising with scalpel. The dorsal tongue was lased through 320$\mu\textrm{m}$optic fiber moving 2.5mm/second to make linear incision 5mm. The five conditions of lasing were three application with 1.0W, 1.75W, 3.0W and 3.0W under saline cooling, and single application with 3.0W at 20Hz. With scalpel, linear incisions through the surface epithelium were performed to 5mm in length. After observing the clinical changes of the incised wounds, the animals were sacrified and the tissues were excised to make the tissue specimens. The stained microscopic tissue slide were observed histologically under the microscope. The following results were obtained : 1. While incision with scalpel causes severe bleeding, lasing does not cause bleeding. 2. In three applications with 1.75W and 20Hz, tissue ablation was limited to areas contacted with optic fiber. 3. In three applications with 3.0W and 20Hz, deep incised wound, extensive destruction of the adjacent epithelium and charring were observed. 4. In three applications with 3.0W and 20Hz under saline cooling, tissue ablation was limite to the superficial mucosa and charring was not observed. 5. In single application with 3.0W and 20Hz, the shape of the incised wound was similar to that of the scalpel incision.

  • PDF

분포온도 계측을 위한 광파이버 온도센서 시스템에 관한 연구 (The study on the fiber optic sensor for the distributed temperature measurement)

  • 이광진;최성구;노도환
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 1997년도 한국자동제어학술회의논문집; 한국전력공사 서울연수원; 17-18 Oct. 1997
    • /
    • pp.1746-1749
    • /
    • 1997
  • A distributed optical fiber temperature sensor can continually monitor the measurand at every point along of its fiber length. It is based on OTDR technics which used extreamlly weak backward scattered light called Raman scattering. When the Pulsed high intensity laser light injected into the optical fiber there are several kind of backscattered light such as Rayleigh, Stokes, and anti-Stokes, etc. caused by impurities molecular vibrations. The temperature distribution is derived form the intensity ratio Raman scatted light-Stokes versus anti-Stokes-and the time function between light injection and signal detection. It is shown that the priniciple of distributed sensing, the system desing, and the result of experiments.

  • PDF

Development of Minimally Invasive Mid-infrared Lipolysis Laser System for Effective Fat Reduction

  • Lee, Ji-Young;Ryu, Han Young;Seo, Young-Seok
    • Medical Lasers
    • /
    • 제10권2호
    • /
    • pp.82-89
    • /
    • 2021
  • Background and Objectives Due to changes in diet and lifestyle, the number of obese people worldwide is steadily increasing. Obesity has an adverse effect on a healthy life, so it needs treatment and improvement. Research related to this is continuously being conducted. Materials and Methods The laser system to compact designed using 808 nm laser diode and Neodymium Yttrium orthovanadate generates a 1064 nm wavelength, the periodically polarized nonlinear crystal pumping laser beam. The pulsed 1064 nm wavelength beam passing through the AO Q-switch is used as the pumping light of the nonlinear optical crystal and is irradiated to the periodic polarized nonlinear optical crystal with a quasi-phase matching period. Nonlinear optical crystals use an oven to control the temperature to generate the desired 1980 nm and 2300 nm wavelengths. Results The 1980 nm and 2300 nm wavelengths generated by temperature control of nonlinear optical crystals are effective for lipolysis. A fiber catheter was used so that the laser could be directly irradiated to the fat cells. In particular, the new wavelength (1980 nm, 2300 nm) can increase the fat reduction effect with low energy (1.3 W). When a laser with a combination wavelength of 1980 nm and 2300 nm was used, an average lipolysis effect of 20% was obtained. Conclusion A mid-infrared lipolysis laser system with excellent absorption of fat and water has been developed. We conducted a princlinical study to confirm the efficacy and safety of the lipolysis laser system, and obtained good results for lipolysis with low energy.

A Plastic BGA Singulation using High Thermal Energy of $2^{nd}$ Harmonic Nd:YAG Laser

  • Lee, Kyoung-Cheol;Baek, Kwang-Yeol;Lee, Cheon
    • KIEE International Transactions on Electrophysics and Applications
    • /
    • 제2C권6호
    • /
    • pp.309-313
    • /
    • 2002
  • In this paper, we have studied minimization of the kerf-width and surface burning, which occurred after the conventional singulation process of the multi-layer BGA board with copper, polyethylene and epoxy glass fiber. The high thermal energy of a pulsed Nd:YAG laser is used to cut the multi-layer board. The most considerable matter in the laser cutting of the multi-layer BGA boards is their different absorption coefficient to the laser beam and their different heat conductivity. The cut mechanism of a multi-layer BGA board using a 2$^{nd}$ harmonic Nd:YAG laser is the thermal vaporization by high temperature rise based on the Gaussian profile and copper melting point. In this experiment, we found that the sacrifice layer and Na blowing are effective in minimizing the surface burning by the reaction between oxygen in the air and the laser beam. In addition, N2 blowing reduces laser energy loss by debris and suppresses surface oxidation. Also, the beam incidence on the epoxy layer compared to polyimide was much more suitable to reduce damage to polyimide with copper wire for the multi layer BGA singulation. When the polyester double-sided tape is used as a sacrifice layer, surface carbonization becomes less. The SEM, non-contact 3D inspector and high-resolution microscope are used to measure cut line-width and surface morphology.

레이저/아크 하이브리드용접기술의 최신 동향 (Recent Technological Tendency of Laser/Arc Hybrid Welding)

  • 김영식;길상철
    • Journal of Welding and Joining
    • /
    • 제31권2호
    • /
    • pp.4-15
    • /
    • 2013
  • The laser/arc hybrid welding process is a new process combining the laser beam and the arc as welding heat source. The laser beam and arc influence and assist one another. By application of hybrid welding, synergistic effects are achievable, and disadvantage of the respective processes can be compensated. The laser-arc hybrid welding process has good potential to extend the field of applications of laser technology, and provide significant improvements in weld quality and process efficiency in manufacturing applications. This review analyses the recent advances in the fundamental understanding of hybrid welding processes using the works of the data base of Web of Science (SCI-Expanded) since the 2000 year. The research activity on the hybrid welding has been become more actively since 2006, especially in China, presenting the most research papers in the world. Since the hybrid welding process was adopted in manufacturing of the automobile in Europe in the early of 2000's, its adopting is widely expanded in the field of manufacturing of automobile, ship building, steel construction and the other various industry. The hybrid welding process is expected to advance toward higher productivity, higher precision, higher reliability through the mixing of high power and flexible fiber laser or disk laser and digitalized pulsed arc source.

KTP 레이저를 이용한 외래 기반 후두 수술의 임상적 적용 (Clinical Applications of Office-Based Laryngeal Surgery With KTP Laser)

  • 조정해
    • 대한후두음성언어의학회지
    • /
    • 제32권3호
    • /
    • pp.118-123
    • /
    • 2021
  • The pulsed photoangiolytic 532-nm potassium-titanyl-phosphate (KTP) laser has emerged in recent years as an efficacious treatment modality for vocal fold lesions. It also has broadened the indications for other laryngeal laser surgery. Features of KTP laser that it is a fiber-based delivery system and its energy is selectively absorbed by oxyhemoglobin make it suitable for office-based laryngeal procedures. An office-based KTP laser surgery provides an alternative management option for benign laryngeal diseases and can be performed comfortably under flexible endoscopic guidance which is placed through the nose of a fully awake patient. Office-based laryngeal surgery with a KTP laser can alleviate the need for general anesthesia. However, there are some limitations to apply due to reduced visual precision and the fact that the vocal folds are moving during procedures. Clinicians should carefully weigh the advantages and disadvantages of office-based procedures before a treatment option is selected. Patient selection and standardized laser energy parameters may help in decreasing complications and improving the treatment results.

Performance of Continuous-wave Coherent Doppler Lidar for Wind Measurement

  • Jiang, Shan;Sun, Dongsong;Han, Yuli;Han, Fei;Zhou, Anran;Zheng, Jun
    • Current Optics and Photonics
    • /
    • 제3권5호
    • /
    • pp.466-472
    • /
    • 2019
  • A system for continuous-wave coherent Doppler lidar (CW lidar), made up of all-fiber structures and a coaxial transmission telescope, was set up for wind measurement in Hefei (31.84 N, 117.27 E), Anhui province of China. The lidar uses a fiber laser as a light source at a wavelength of $1.55{\mu}m$, and focuses the laser beam on a location 80 m away from the telescope. Using the CW lidar, radial wind measurement was carried out. Subsequently, the spectra of the atmospheric backscattered signal were analyzed. We tested the noise and obtained the lower limit of wind velocity as 0.721 m/s, through the Rayleigh criterion. According to the number of Doppler peaks in the radial wind spectrum, a classification retrieval algorithm (CRA) combining a Gaussian fitting algorithm and a spectral centroid algorithm is designed to estimate wind velocity. Compared to calibrated pulsed coherent wind lidar, the correlation coefficient for the wind velocity is 0.979, with a standard deviation of 0.103 m/s. The results show that CW lidar offers satisfactory performance and the potential for application in wind measurement.

Coherent Absorption Spectroscopy with Supercontinuum for Semiconductor Quantum Well Structure

  • Byeon, Ciare C.;Oh, Myoung-Kyu;Kang, Hoon-Soo;Ko, Do-Kyeong;Lee, Jong-Min;Kim, Jong-Su;Choi, Hyoung-Gyu;Jeong, Mun-Seok;Kee, Chul-Sik
    • Journal of the Optical Society of Korea
    • /
    • 제11권3호
    • /
    • pp.138-141
    • /
    • 2007
  • We suggest that supercontinuum can be used for absorption spectroscopy to observe the exciton levels of a semiconductor nano-structure. Exciton absorption spectrum of a GaAs/AlGaAs quantum well was observed using supercontinuum generated by a microstructrured fiber pumped by a femtosecond (fs) pulsed laser. Significantly narrower peaks were observed in the absorption spectrum from 11 K up to room temperature than photoluminescence (PL) spectrum peaks. Because supercontinuum is coherent light and can readily provide high enough intensity, this method can provide a coherent ultra-broad band light source to identify exciton levels in semiconductors, and be applicable to coherent nonlinear spectroscopy such as electromagnetically induced transparency (EIT), lasing without inversion (LWI) and coherent photon control in semiconductor quantum structures.

High-power SESAM Mode-locked Yb:KGW Laser with Different Group-velocity Dispersions

  • Park, Byeong-Jun;Song, Ji-Yeon;Lee, Seong-Yeon;Yee, Ki-Ju
    • Current Optics and Photonics
    • /
    • 제6권4호
    • /
    • pp.407-412
    • /
    • 2022
  • We report on a diode-laser-pumped mode-locked Yb:KGW laser system, which delivers ultrashort pulses down to 89 fs at a repetition rate of 63 MHz, with an average power of up to 5.6 W. A fiber-coupled diode laser at 981 nm, operated with a compact driver, is used to optically pump the gain crystal via an off-axis parabolic mirror. A semiconductor saturable-absorber mirror is used to initiate the pulsed operation. Laser characteristics such as the pulse duration, spectrum bandwidth, and output power are investigated by varying the intracavity dispersions via changing the number of bounces between negative-dispersive mirrors within the cavity. Short pulses with a duration of 89 fs, a center wavelength of 1,027 nm, and 3.6 W of output power are produced at a group-velocity dispersion (GVD) of -3,300 fs2. As the negative GVD increases, the pulse duration lengthens but the output power at the single-pulse condition can be enhanced, reaching 5.6 W at a GVD of -6,600 fs2. Because of pulse broadening at high negative GVDs, the highest peak intensity is achievable at a moderate GVD with our system.

염증성 치은에 대한 Nd:YAG laser 조사효과에 관한 임상적 연구 (A clinical study of the effect of Nd:YAG laser irradiation on inflamed gingiva)

  • 조형수;김현섭;임기정;김병옥;한경윤
    • Journal of Periodontal and Implant Science
    • /
    • 제26권2호
    • /
    • pp.531-541
    • /
    • 1996
  • Periodontal disease is characterized by destruction of supporting tissues caused by invasion of plaque bacteria and defense mechanism of host. Many dentists are very interested in laser therapy on various intraoral soft tissue lesions including inflammatory periodontal pocket. In order to determine the therapeutic effect of intrapocket irradiation of a pulsed- Nd : YAG laser on the inflammatory periodontal pockets, bilateral 60 teeth with 4-6mm in probing pocket depth and gingival inflammation were selected and evaluated by sulcus bleeding index(SBI), and plaque index(pI) for baseline record. Intrapocket irradiation($300{\mu}m$ fiber optic, I.5W power, for 2 min.) of a pulsed-Nd : YAG laser(EL.EN.EN060, Italy) was applied on half of them. As the control group, the same procedure except power-off was repeated on the contralateral 30 teeth. At 1-, 2-, 3-, and 4-week after intrapocket manipulation, every tooth was reevaluated by the same clinical indices. And the difference between the lased group and control group was statistically analyzed by paired t-test and Chi-square test in Microstat program. Following results were obtained: 1. Until I-week and 2-week after intrapocket manipulation, SBI was lowered in both lased group and control group, compared to baseline SBI, but from 3-week after, the recovering tendency toward baseline was noted, and at only 2-week after, the number of teeth showing lowered SBI was significantly more in lased group than in control group(p<0.05). 2. PI of both lased group and control group was lowered through whole experimental period from I-week to 4-week after, compared to baseline PI(p<0.05), but there was no significant difference between lased group and control group(p>0.1). The results suggest that intrapocket irradiation of a pulsed-Nd:YAG laser may lead somewhat remission of gingival inflammation, but for more favorable therapeutic result the thorough root planing should be necessarily accompanied with gingival curettage.

  • PDF