한방 맥파 분석을 위한 디지틸 시스템 설계 (Digital System for Analyging Oriental Pulse Signals Designed)

  • 이준영;서현우;이정환;김정훈;이명호
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2000년도 제15차 학술회의논문집
    • /
    • pp.544-544
    • /
    • 2000
  • From ancient times. the diagnosis method of the oriental medicine has been Performed by curing diseases by means of rectifying and adjusting the unbalance in the Physiological function of the five viscera and the six bowels of a human body. Diseases have been diagnosed by the condition of blood circulation that cycles a human body through blood vessels by dint of the vitality of the heart, Based on such a systematic pulse diagnosis method, the article presents parameters that will be beneficial to clinical application on the basis of its analysis of the filtering for eliminating noises from pulse signals inputted from sensor group the digital hardware dealing with signals necessary for recognition algorithm. and the structure of diagnosis algorithm and components of pulse waveform.

  • PDF

3차원 로봇 맥 영상 분석기의 5단계 가압 맥파 분석에 의한 고혈압 환자의 현맥(弦脈) 연구 (A study on wiry pulse in hypertensive patients analyzed at 5 levels of applied pressure using 3 dimensional pulse imaging analyzer)

  • 강희정;권영상;김달래;김경철;임윤경
    • Korean Journal of Acupuncture
    • /
    • 제27권1호
    • /
    • pp.1-12
    • /
    • 2010
  • Objectives: The purpose of this study is to gain the objective indicators for the classification of hypertension by oriental medical pulse diagnosis, through finding out the parameters which can distinguish the pulse of hypertensive patient from that of normal subject, and characterizes the wiry pulse of hypertension. Methods: 30-59 yr, male, 946 healthy volunteers and 35 hypertensive patients were enrolled in this study. All the hypertensive patients were taking medicine to control the blood pressure and the blood pressure of the hypertension group was not statistically different from that of the normal healthy group. Data were acquired using 3 dimensional pulse imaging analyser(DMP-3000, DAEYOMEDI, KOREA) and analysed according to the age bands and the applied pressure levels. Results: 1. RAI/t, w/t and t2/t decreased with the levels of applied pressure and increased with age in the normal healthy group, not in the hypertension group. 2. RAI/t, w/t, t2/t were significantly higher in the hypertension group than the normal healthy group in the 30-age band, and elasticity coefficient was higher in the hypertension group than the normal healthy group in the 40-age band. 3. Researches on the patients without hypotensive agents are needed to figure out whether these parameters are the components of hypertensive wiry pulse. Conclusions: Analysing the radial pulse at 5 applied pressure levels using 3 dimensional pulse imaging analyser may be useful to differentiate the pulses of the hypertensive patients from those of the normal subjects, and characterize the hypertension.

5단계 가압 맥파측정에 의한 연령별 혈관 경화도 분석 (Analysis of Arterial Stiffness by Age Using Pulse Waveform Measurement of 5-levels Graded Pressure)

  • 권선민;강희정;임윤경;이용흠
    • Korean Journal of Acupuncture
    • /
    • 제27권2호
    • /
    • pp.107-120
    • /
    • 2010
  • Objectives : The aim of this study is to measure pulse waveforms by applying 5-level graded pressure, and selecting optimum pulse waveforms. Also to proposing the possibility of using AW(Area of the 1/3 upper height of h1) rate in respect to AT(Total Area) for risk assessment of hypertension or arteriosclerosis is another aim of the study. Methods : Pulse waveforms of normotensive were measured by 5-level graded pressure. The pulse waveforms well reflecting properties of blood vessel(having the largest h1) were selected for optimum pulse waveforms. Various parameters(h-parameter, t-parameter, and others) of optimum pulse waveforms were analyzed. AIx(Augmentation index) was calculated by height-parameters to assess arterial stiffness. The area rate of the 1/3 upper height for h1 in respect to total area was analyzed according to aging. Results : According to aging 1. in height-parameter, h2 and h3 were increased but h5 was decreased. 2. In time-parameter, t2, t3, and t5 were getting short. 3. Area of systolic period was increased, and that of diastolic period decreased. 4. AIx rose by aging. 5. AW was significantly increased despite no changes in AT. Conclusions : By analyzing optimum pulse waveforms of 5-level graded pressure method, we could complement weakness of single graded pressure method. Also, possibility of applying the AW rate to risk assessment of hypertension or arteriosclerosis was confirmed in normotensive population which might not be assessed by AIx.

운방전에 의해 발생한 전자장 펄스의 통계적 특성 (Statistical Characteristics of the Electromagnetic Pulses Radiated from Intracloud Discharges)

  • 이복희;정동철;이동문;안창환
    • 조명전기설비학회논문지
    • /
    • 제18권5호
    • /
    • pp.112-117
    • /
    • 2004
  • 본 연구에서는 뇌전자장 펄스에 관한 상세한 정보를 얻기 위한 목적으로 운방전에 의해서 방사되는 전자파 펄스를 측정하고, 이의 특성과 파라미터를 통계적으로 분석하였다. 운방전에 의해서 방사된 전자파 펄스는 낙뢰에 의한 것과는 확연하게 달랐으며, 후속 스토로크로 갈수록 주 방전에 의한 양방성 전자파 펄스의 영점교차시간과 펄스폭은 짧게 나타났다. 또한 주 방전에 의한 양방성 전자파 펄스의 파두부분에는 좁고 빠른 리더펄스가 중첩되어 나타났으며, 이 중첩된 리더펄스의 평균 개수는 정극성에서 61$\pm$0.74, 부극성에서 1.75$\pm$0.73이었다.

고출력 레이저-증폭기 계열의 Isolator 설계-(II) (Design of an Isolator of High Power Laser-Amplifier Series-(II))

  • 나승환
    • 한국광학회:학술대회논문집
    • /
    • 한국광학회 1989년도 제4회 파동 및 레이저 학술발표회 4th Conference on Waves and lasers 논문집 - 한국광학회
    • /
    • pp.7-11
    • /
    • 1989
  • A Faraday rotator is designed with the HOYA FR-5 rotator glass. We find that traveling light rotates 45$^{\circ}$in the glass when magnetic field intensity is about 3.0$\times$105AT/m. The current of 2.7KA flowing in the coil of the 0cm diameter, 29cm long and 41 windings generates this magnetic field. A pulse forming network is designed for this current of 84 sec duration. The network is analyzed numerically to find the relevant circuit parameters for the flattest current waveform.

  • PDF

Nonconstrained Blood Pressure Measurement by Photoplethysmography

  • Yoon Young-Zoon;Yoon Gil-Won
    • Journal of the Optical Society of Korea
    • /
    • 제10권2호
    • /
    • pp.91-95
    • /
    • 2006
  • Blood pressure was predicted from photoplethysmography (PPG). To obtain PPG, backscattered light from a fingertip was measured and its waveform was analyzed. Systolic upstroke time and diastolic time in the pulse waveform were used as parameters to predict blood pressure. The experiment was carried out with five subjects on five different days. The systolic upstroke time had a correlation coefficient of -0.605 with respect to systolic blood pressure and the diastolic time had a correlation coefficients of -0.764 for diastolic pressure. This PPG method does not require an air-cuff installation on the arm and can predict blood pressure continuously. This simple LED/photo detector setup can be a good candidate for nonconstrained monitoring of blood pressure variations.

Al 5J32 합금의 레이저 용접에서 레이저출력 모듈레이션을 이용한 이면 험핑 비드의 안정화 (Prevention of Back Side Humping in Laser Welding of Al 5J32 Alloy by Using Laser Power Modulation)

  • 안도창;김철희;김재도
    • Journal of Welding and Joining
    • /
    • 제29권4호
    • /
    • pp.80-84
    • /
    • 2011
  • In the 5xxx series Al-Mg alloy, magnesium addition can increase the strength of aluminum alloy by solid solution strengthening but it has a relatively low melting and boiling temperature. During full -penetration laser welding of the Al-Mg alloys, its low boiling point and high vapor pressure brings about the spiky humping bead on the bottom side. Under back-side shielding, the spiking of back bead can be reduced but it restraints the process flexibility. In this study, a square pulse waveform modulation was employed to stabilize keyhole and back bead surface without back-side shielding. By using an experimental design, the bead shapes were evaluated for various process parameters such as the focal position, welding velocity and waveform parameters and the smooth back bead shape could be achieved.

Effects of a Static Synchronous Series Compensator (SSSC) Based on a Soft Switching 48-Pulse PWM Inverter on the Power Demand from the Grid

  • Ustun, Taha Selim;Mekhilef, Saad
    • Journal of Power Electronics
    • /
    • 제10권1호
    • /
    • pp.85-90
    • /
    • 2010
  • In this paper the effects of a Static Synchronous Series Compensator, which is constructed with a 48-pulse inverter, on the power demand from the grid are studied. Extensive simulation studies were carried out in the MATLAB simulation environment to observe the compensation achieved by the SSSC and its effects on the line voltage, line current, phase angle and real/reactive power. The designed device is simulated in a power system which is comprised of a three phase power source, a transmission line, line inductance and load. The system parameters such as line voltage, line current, reactive power Q and real power P transmissions are observed both when the SSSC is connected to and disconnected from the power system. The motivation for modeling a SSSC from a multi-pulse inverter is to enhance the voltage waveform of the device and this is observed in the total harmonic distortion (THD) analysis performed at the end of the paper. According to the results, the power flow and phase angle can be controlled successfully by the new device through voltage injection. Finally a THD analysis is performed to see the harmonics content. The effect on the quality of the line voltage and current is acceptable according to international standards.

계단 주파수 레이더에서 이동표적의 고해상도 거리 추정을 위한 코히어런트 펄스열 기반의 속도 추정 및 보상 (Coherent Pulse Train Based Velocity Estimation and Compensation for High Resolution Range Profile of Moving Target in Stepped Frequency Radar)

  • 심재훈;배건성
    • 전기전자학회논문지
    • /
    • 제22권2호
    • /
    • pp.309-315
    • /
    • 2018
  • 계단 주파수 레이더(Stepped Frequency Radar: SFR)는 송신 펄스의 주파수를 점진적으로 증가시켜 넓은 합성 대역폭을 만듦으로써 높은 거리 해상도를 얻는 방식이다. 그런데 이동표적의 경우 거리-도플러 결합(range-Doppler coupling) 현상으로 정확한 거리 추정을 할 수 없게 되므로 정확한 속도 추정을 통한 보상이 필요하다. 본 논문에서는 코히어런트 펄스열(Coherent Pulse Train: CPT)을 갖는 계단 주파수 레이더 파형을 제안하고, 이를 이용한 속도 추정 및 파라미터에 따른 결과를 기존의 VMD(Velocity Measurement Data) 방식과 시뮬레이션을 통해 비교하고 분석하였다.

Systolic blood pressure measurement algorithm with mmWave radar sensor

  • Shi, JingYao;Lee, KangYoon
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • 제16권4호
    • /
    • pp.1209-1223
    • /
    • 2022
  • Blood pressure is one of the key physiological parameters for determining human health, and can prove whether human cardiovascular function is healthy or not. In general, what we call blood pressure refers to arterial blood pressure. Blood pressure fluctuates greatly and, due to the influence of various factors, even varies with each heartbeat. Therefore, achievement of continuous blood pressure measurement is particularly important for more accurate diagnosis. It is difficult to achieve long-term continuous blood pressure monitoring with traditional measurement methods due to the continuous wear of measuring instruments. On the other hand, radar technology is not easily affected by environmental factors and is capable of strong penetration. In this study, by using machine learning, tried to develop a linear blood pressure prediction model using data from a public database. The radar sensor evaluates the measured object, obtains the pulse waveform data, calculates the pulse transmission time, and obtains the blood pressure data through linear model regression analysis. Confirm its availability to facilitate follow-up research, such as integrating other sensors, collecting temperature, heartbeat, respiratory pulse and other data, and seeking medical treatment in time in case of abnormalities.