• 제목/요약/키워드: pulse tube refrigerator

검색결과 53건 처리시간 0.018초

맥동관 냉동기에서 관성관의 모델링에 관한 연구 (A study on the modeling of the inertance tube in the pulse tube refrigerator)

  • 남관우;정상권
    • 한국초전도저온공학회:학술대회논문집
    • /
    • 한국초전도저온공학회 1999년도 제1회 학술대회논문집(KIASC 1st conference 99)
    • /
    • pp.153-156
    • /
    • 1999
  • In this paper, the inertance tube is modeled by the distributed impedance model. This model is verified by the analytical solutions for the long tube without the reservoir. In this model the distributed impedace effect of the inertance tube is included and mass flow rate and pressure distributions are calculated along the inertance tube for various inertance tube lengths. Mass flow rate at the inlet of the inertance tube is also calculated by this model and compared to the lumped impedance method. Mass flow rate by the distributed model shows quite different behaviors from the lumped model when the operating frequency is high and the length of the tube becomes large.

  • PDF

크라이오 펌프 냉동기 냉각용량 측정방안 (Scheme for Measuring Refrigeration Capacity of Cryopump Refrigerator)

  • 인상렬;조희승;정승호
    • 한국진공학회지
    • /
    • 제20권4호
    • /
    • pp.243-251
    • /
    • 2011
  • 국내에서 개발 중인 맥동관형 냉동기 및 일반적인 GM 냉동기 성능평가를 위해 냉각용량 측정 장치를 제작한 후, 측정절차 검토 및 장치 성능확인의 일환으로 상용 냉동기의 냉각용량을 측정했다. 측정된 2차원 냉각용량 차트는 실험에 사용한 냉동기 모델이 가지는 고유 특성을 잘 나타냈다. 이 논문에서는 제작된 냉각용량 평가 장치의 설계사항 및 시운전 결과를 소개한다.

Numerical and experimental studies of cryogenic reciprocating expander without inner piston

  • Park, Sehyeon;Bae, Junhyuk;Kim, Kyoungjoong;Jeong, Sangkwon
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제20권3호
    • /
    • pp.21-27
    • /
    • 2018
  • It is difficult to fabricate and maintain moving parts of expander at cryogenic temperature. This paper describes numerical analysis and experimental investigation on a cryogenic reciprocating expander without moving piston. An intake valve which takes high-pressure gas, and an exhaust valve which discharges low-pressure gas, are connected to a tube. The inside pressure of the tube is pulsated for work production. This geometric configuration is similar to that of pulse tube refrigerator but without regenerator. An orifice valve and a reservoir are installed to control the phase of the mass flow and the pressure. At the warm end, a heat exchanger rejects the heat which is converted from the produced work of the expanded gas. For the numerical analysis, mass conservation, energy conservation, and local mass function for valves are used as the governing equations. Before performing cryogenic experiments, we carried out the expander test at room temperature and compared the performance results with the numerical results. For cryogenic experiments, the gas is pre-cooled by liquid nitrogen, and then it enters the pulse tube expander. The experiments are controlled by the opening of the orifice valve. Numerical analysis also found the expander conditions that optimize the expander performance by changing the intake pressure and valve timing as well as the opening of the orifice valve. This paper discusses the experimental data and the numerical analysis results to understand the fundamental behavior of such a newly developed non-mechanical expander and elucidate its potential feature for cryogenic application.

초전도필터 및 적외선검지기 냉각용 극저온냉동기 (Cryocoolers for cooling of HTS RF Filter and IR detector)

  • 홍용주
    • 한국정밀공학회지
    • /
    • 제19권11호
    • /
    • pp.18-23
    • /
    • 2002
  • 고품질의 극저온 환경의 생성 및 유지는 고품질 대용량 정보통신, 의료진단, 초전도 및 고집적반도체 제조공정 등의 차세대 유망 산업 분야에서 필수적인 요소로 자리 잡고 있으며, cryopump, 민수용 및 군수용의 적외선 검지기 및 초전도 RF 필터의 효과적 냉각을 위해 보다 높은 신뢰성과 수명, 고효율의 극저온 냉동기에 대한 수요는 점차 증대될 것으로 기대된다. 스터링 냉동기 및 맥동관 냉동기는 짧은 역사에도 불구하고, 다양한 분야에서 기존의 한제 및 극저온 냉동기를 대치하여 활용될 수 있을 것으로 전망된다.

스터링 냉동기의 압력특성에 관한 실험적 연구 (Experimental Study of the pressure characteristics in the Stirling refrigerator)

  • 홍용주;박성제;김효봉;고득용
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2001년도 추계학술대회논문집B
    • /
    • pp.118-123
    • /
    • 2001
  • The linear compressor have been widely used for pressure wave generation in the Stirling cryocooler and Stirling type pulse tube cryocooler for tactical purpose. The linear compressor has small and compact structure, and long life due to having non-contact sealing mechanism. and the pressure drop through regenerator was ver important role in the motion of displacer in the expander of the Stirling cryocooler. In this study, the characteristic of the linear compressor and the pressure drop through regenerator in the expander was experimentally investigated. The results show the resonance of the compressor is very important to get maximum performance. and the gas spring force in the compression space of the compressor has effect on the characteristic of reonance. and the results show the pressure drop through regenerator is very small than operating pressure change.

  • PDF

공진특성을 고려한 냉동/공조용 횡자속 선형압축기의 설계 (The Design of a Linear Compressor Based on the Resonance Characteristics for the Air Conditioner)

  • 홍용주;박성제;김효봉
    • 연구논문집
    • /
    • 통권34호
    • /
    • pp.39-46
    • /
    • 2004
  • The compressors in the air conditioner have the role of the pressurization and circulation of the refrigerant. The hermetic reciprocating compressors driven by rotary motor have been used for the air conditioner. The linear compressor has very simple structure and enhancement in the efficiency in comparison to that of conventional reciprocating compressor. The linear compressors are widely used for the small cryogenic refrigerator (below 1 kW), such as the Stirling refrigerator and pulse tube refrigerator. In the cryogenic application, the pressure ratio of the linear compressor is below 1.5, but the linear compressor for the air conditioner should overcome the high pressure ratio and the large pressure difference between the each sides of the piston. The resonance characteristics of the linear compressor has the significant impacts on the power consumption. To minimize the power consumption, the linear compressor should be operated at the resonance point. In the resonance characteristics, the role of the mechanical and gas spring should be considered. In present study, the cycle of the analysis of the vapor compression refrigeration cycle with the different refrigerants (R134a, R4l0a, R600a) and the designs of the linear compressor are performed. The effects of the stiffness of the mechanical spring on the electromagnetic forces would be discussed. Finally, the results show the design specification of the linear compressor for the air conditioner.

  • PDF

고온초전도 시스템의 새로운 냉각기술 (New Cooling Techniques of High Tc Superconductor Systems)

  • 장호명
    • 한국초전도학회:학술대회논문집
    • /
    • 한국초전도학회 1999년도 High Temperature Superconductivity Vol.IX
    • /
    • pp.7-11
    • /
    • 1999
  • The recent progress in new cooling techniques of the high Tc superconductor(HTS) systems is reported and discussed with some practical examples. At the beginning stage of the HTS development in research laboratories, liquid nitrogen(LN$_2$) is the standard medium for an effective cooling. The success of HTS in many different application areas, however, has required a variety of need in the cooling temperature and the cooling capacity with specific design restrictions. While the utilization of alternative liquid cryogens such as liquid neon (LNe) or liquid hydrogen (LH$_2$) has been tired in some of them, even solid cryogens such as solid nitrogen (SN$_2$) or solid hydrogen (SH$_2$) may be another option in special applications. The gaseous helium cooled by a cryogenic refrigerator has also been a good candidate in many cases. One of the best cooling methods for the HTS is the direct conduction-cooling by a closed-cycle refrigerator with no cryogen at all. The refrigeration may be based on Joul-Thomson, Brayton, Stirling, Gifford-McMahon, or pulse tube cycles. The pros and cons of the newly proposed cooling methods are described and some significant design issues are presented.

  • PDF

Performance test of 100 W linear compressor

  • Ko, J.;Koh, D.Y.;Park, S.J.;Kim, H.B.;Hong, Y.J.;Yeom, H.K.
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제15권3호
    • /
    • pp.35-39
    • /
    • 2013
  • In this paper, we present test results of developed 100 W class linear compressor for Stirling-type pulse tube refrigerator. The fabricated linear compressor has dual-opposed configuration, free piston and moving magnet type linear motor. Power transfer, efficiency and required pressure waveform are predicted with designed and measured specifications. In experiments, room temperature test with flow impedance is conducted to evaluate performance of developed linear compressor. Flow impedance is loaded to compressor with metering valve for flow resistance, inertance tube for flow inertance and buffer volumes for flow compliance. Several operating parameters such as input voltage, current, piston displacement and pressure wave are measured for various operating frequency and fixed input current level. Behaviors of dynamics and performance of linear compressor as varying flow impedance are discussed with measured experimental results. The developed linear compressor shows 124 W of input power, 86 % of motor efficiency and 60 % of compressor efficiency at its resonant operating condition.

탑재형 냉동기를 이용한 고온 초전도 모터 개발 및 회전 실험 (Development and rotating test of the high temperature superconducting motor with on-board cryocooler)

  • 기태경;김영권;김희선;정상권
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제13권1호
    • /
    • pp.12-16
    • /
    • 2011
  • In this paper, the prototype of the HTS motor with an on-board cryocooler, is fabricated and tested. The overall system is composed of the stator with conventional copper winding, the rotor with superconductor, and the rotating cryocooler designed from the on-board concept. The rotor is fabricated as the race-track coil with 2G, YBCO tape and contacts with the on-board cryocooler while being rotated together. An inline-type pulse tube refrigerator is used as the on-board cryocooler. The cryocooler is fabricated from optimal process to satisfy the structure and thermal stability of the on-board system. Each component is integrated according to carefully defined sequence. Specially, a combining method of torque tubes is an important part for sustaining stability of the rotor and the cryocooler. In the rotating test, the HTS motor is successfully operated with 240 rpm of rotating speed when 75 A current is supplied to the superconducting rotor. In this paper, potential problems of the HTS motor system using the on-board cryocooler are proposed and solved, and realistic possibility of this concept is also confirmed.