• Title/Summary/Keyword: pulse trigger

Search Result 81, Processing Time 0.024 seconds

A Design of Real-Time QRS Detection in Physio-Module for Echocardiography (심초음파용 실시간 심전도 QRS 검출 모듈에 관한 연구)

  • Jang, Won-Seuk;Kim, Nam-Hyun;Kim, Eong-Sok;Jeon, Dae-Keun
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.47 no.3
    • /
    • pp.40-47
    • /
    • 2010
  • In this study, we investigated the performance of real-time QRS complex detection algorithm in physio-module for echocardiography. The performance of QRS detection module in echocardiography was evaluated according to international standard, EC-13 and we compared with commercialized physio-module with QRS complex detection. In this study, we can get performance of QRS complex detection, pacer pulse detection, Tall t-wave rejection and arrhythmia detection within EC-13's criteria and we can get improved QRS trigger delay time and baseline wondering rejection times in compared with commercialized physio-module.

The research for the triggered vacuum switch which made of a copper electrode

  • Park, Ung-Hwa;Kim, Mu-Sang;Lee, Byeong-Jun
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2015.08a
    • /
    • pp.144.1-144.1
    • /
    • 2015
  • The triggered vacuum switch(TVS) is a one of the important component in consisiting high power control systems(HPCS). The operating condition is depended on material, geometry, operating power and so on. Our research is focused on the effects of thses basic properties and ptimized condition, because these are critical conditons in understanding the TVS operation. Our experiment is accomplished with a copper electrode and a tungsten trigger pin after being assembled into a vacuum chamber. The operating voltage in our system is more than dozens of kV at the 5kV trigger pulse. Our goal is up to 300kJ, therefore the currents should be more optimized in additional experiments,

  • PDF

Characteristics of High Voltage Discharge using Triggered Spark Gap (Trigged Spark Gap의 고전압 방전제어특성 연구)

  • Son, Yoon-Gyu;Kim, Kwang-Gi;Park, Sang-Wook;Cho, Moo-Hyun
    • Proceedings of the KIEE Conference
    • /
    • 1997.07e
    • /
    • pp.1816-1818
    • /
    • 1997
  • A triggered sparkp gap switch was fabricater and its high-voltage discharge characteristics were studied. The switch is composed of two main electrodes and one trigger electrode which is placed perpendicular to the main one. Spark gap distance was fixed by 25 mm. This device has been operated without self firing at the pulse repetition frequency from 1 to 20 Hz limited by the charging current, and the hold-off voltage from 10 to 30kV. An IGBT switch and igniter coil (originally used in a car) were adopted for a trigger circuit. In this article preliminary switch characteristics of the spark gap switch are reported with the emphasis on the description of the trigger circuit.

  • PDF

Design of an FPGA Based Controller for Delta Modulated Single-Phase Matrix Converters

  • Agarwal, Anshul;Agarwal, Vineeta
    • Journal of Power Electronics
    • /
    • v.12 no.6
    • /
    • pp.974-981
    • /
    • 2012
  • A FPGA based delta modulated single phase matrix converter has been developed that may be used in both cyclo-converters and cyclo-inverters. This converter is ideal for variable speed electrical drives, induction heating, fluorescent lighting, ballasts and high frequency power supplies. The peripheral input-output and FPGA interfacing have been developed through Xilinx 9.2i, to generate delta modulated trigger pulses for the converter. The controller has been relieved of the time consuming computational task of PWM signal generation by implementing the method of trigger pulse generation in a FPGA by using Hardware Description Language VHDL in Xilinx. The trigger circuit has been tested qualitatively by observing various waveforms on an oscilloscope. The operation of the proposed system has been found to be satisfactory.

A Study on Development of Oscillator Measurement Device Using Double Edge Time Interval Frequency Counter (더블 에지타임 인터벌 카운터를 이용한 발진기특정 장치개발에 관한 연구)

  • Hwang, Gi-Hyun
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.13 no.7
    • /
    • pp.1386-1392
    • /
    • 2009
  • In this paper, we have developed the test equipment to measure performance of oscillator using Double Side Edge Trigger(DSET). This DSET increases counting number of micro pulse by frequency counter, which will successfully reduce the half measuring time to comparison with the existing counter by using DSET. This new concept of performance measuring equipment provides a high productivity and performance improvement.

A Study on Fast Switching System for High Power Pulse (대전력 펄스의 고속 스위칭 연구)

  • Lee, Seok-Woo;Lee, Young-Ho;Ha, Seoung-Ho
    • Proceedings of the KIEE Conference
    • /
    • 1998.07f
    • /
    • pp.1869-1871
    • /
    • 1998
  • In this paper, we designed and fabricated a fast switching system for high power pulse. This system consists of a voltage conversion circuit, high voltage charging circuit, trigger circuit, and discharging circuit. Especially discharging line is designed by strip-line for low inductance and resistance. The experimental result is that current slew rate of the system is 6.67kA/86ns and this result is fully qualified for initiating EBW or EFI

  • PDF

A Novel Multi-Quantum Well Injection Mode Diode And Its Application for the Implementation of Pulse-Mode Neural Circuits (다중 양자우물 주사형 다이오드와 펄스-모드 신경회로망 구현을 위한 그 응용)

  • Song Chung Kun
    • Journal of the Korean Institute of Telematics and Electronics A
    • /
    • v.31A no.8
    • /
    • pp.62-71
    • /
    • 1994
  • A novel semiconductor device is proposed to be used as a processing element for the implementation of pulse-mode neural networks which consists of alternating n' GaAs quantum wells and undoped AlGaAs barriers sandwitched between n' GaAs cathode and P' GaAs anode and in simple circuit in conjunction with a parallel capacitive and resistive load the trigger circuit generates neuron-like pulse train output mimicking the function of axon hillock of biological neuron. It showed the sigmoidal relationship between the frequency of the pulse-train and the applied input DC voltage. In conjunction with MQWIMD the various neural circuits are proposed especially a neural chip monolithically integrated with photodetectors in order to perfrom the pattern recognition.

  • PDF

A Development of Ultrasonic Based Distance Meter Through Detachment of Receiving and Transmitting Capacitive Ultrasonic Transducer (송.수신 분리형 초음파 거리 측정기 개발)

  • Kim Jung-Hoon;Chong Jong-Wha
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.43 no.3 s.309
    • /
    • pp.41-50
    • /
    • 2006
  • This paper presents a novel ultrasonic sensor system to overcome limited distance detection range that can be measured only more than 30cm by single ultrasonic transducer. This is accomplished by separation of receiving capacitive ultrasonic transducer from transmitting capacitive ultrasonic transducer. And hardwares and software of the system are described in detail. The system makes very close range as well as long range detect by wireless precisely. Frequency of trigger pulse is 10Hz, but it is very low frequency for transmitting data in wireless module. Therefore, for triggering between receiver and transmitter, an algorithm for mixing and distinguishing trigger pulse from carrier pulse by software is proposed. The system is designed by common microprocessor 8051. The performance of the proposed method has been assessed through two types. The first, transmitting and receiving transducer are put on both sides. And then, distance of two point is measured as far as 0mm. Secondly, transmitting transducer send out ultrasonic pulse and measure the time of flight(TOF) until a first echo from an object detected by the detached receiving transducer. The distance between the detached transducers and a reflecting object is measured as far as 7cm. Images of measured ultrasonic waves and TOF for two methods presented to prove effectiveness of results.

Manufacture of a Small RTE for Real-Time Extraction of Radar Signal (레이더 신호의 실시간 추출을 위한 소형 레이더 목표 추출기 개발)

  • Sung Tae-Kyung;Kim Dong-Seek;Cho Hyung-Rae
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.15 no.9
    • /
    • pp.835-840
    • /
    • 2004
  • Using of small Radar device can not supply the real exercise information of ellipse circumference or CPA, TCPA and the changing of surroundings fur various target information. Therefore, for the above problem, we develop RTE that is able to and of for each information from ARPA Radar which supply analog video signal, trigger bearing and heading pulse from low-cost small Radar device is equiped with general small fishing boat. The small fishing is equipped with small Radar device, so it is able to collect and apply sailing information such as real exercise information and TCPA.

Implementation of Digital Signal Processing Board Suitable for a Semi-active Laser Tracking to Detect a Laser Pulse Repetition Frequency and Optimization of a Target Coordinates (반능동형 레이저 유도 추적에 적합한 레이저 펄스 반복 주파수 검출을 위한 디지털 신호처리 보드 구현 및 표적 좌표 최적화)

  • Lee, Young-Ju;Kim, Yong-Pyung
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.64 no.4
    • /
    • pp.573-577
    • /
    • 2015
  • In this paper, we propose a signal processing board suitable for a semi-active laser tracking to detect an optical signal generated from the laser target designator by applying an analog trigger signal, the quadrant photodetector and a high speed ADC(analog-digital converter) sampling technique. We improved the stability by applying the averaging method to minimize the measurement error of a gaussian pulse. To evaluate the performances of the proposed methods, we implemented a prototype board and performed experiments. As a result, we implemented a frequency counter with an error 14.9ns in 50ms. PRF error code has a stability of less than 1.5% compared to the NATO standard. Applying the three point averaging method to ADC sampling, the stability of 28% in X-axis and 22% in Y-axis than one point sampling was improved.