• Title/Summary/Keyword: pulse sensor

Search Result 548, Processing Time 0.031 seconds

Motion-based Controlling 4D Special Effect Devices to Activate Immersive Contents (실감형 콘텐츠 작동을 위한 모션 기반 4D 특수효과 장치 제어)

  • Kim, Kwang Jin;Lee, Chil Woo
    • Smart Media Journal
    • /
    • v.8 no.1
    • /
    • pp.51-58
    • /
    • 2019
  • This paper describes a gesture application to controlling the special effects of physical devices for 4D contents using the PWM (Pulse Width Modulation) method. The user operation recognized by the infrared sensor is interpreted as a command for 3D content control, several of which manipulate the device that generates the special effect to display the physical stimulus to the user. With the content controlled under the NUI (Natural User Interface) technique, the user can be directly put into an immersion experience, which leads to provision of the higher degree of interest and attention. In order to measure the efficiency of the proposed method, we implemented a PWM-based real-time linear control system that manages the parameters of the motion recognition and animation controller using the infrared sensor and transmits the event.

Pulse wave Measurement System by analyzing a Moving Pulse Image in the Capillary Tube (모세관 맥동파 영상을 이용한 맥파 측정 시스템)

  • Lee, Woo-Beom;Choi, Chang-Yur;Hong, You-Sik;Lee, Sang-Suk;Nam, Dong-Hyun
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.12 no.2
    • /
    • pp.145-151
    • /
    • 2012
  • The pulsimeter is a representative device in the oriental medicine, which can analysis a risk factor in a cardiovascular diseases. However, most of the previous methods have the limit by the contacted sate of the brachial pulse and sensor in the measuring time, the inaccuracy of detected pulse, and the difficulty of pulse analysis. Accordingly, we propose the moving pulse image analysis based pulsimeter that can acquire a pulse of patient in real time by analyzing a moving image. then this video is shot the state change of the T.S. occurred by a pulse in capillary. In order to evaluate the performance of the our pulsimeter, we measured a respective detecting-rate about the essential 5 feature-points in the pulse analysis from the detected original pulse. As a result, the proposed method is very successful.

Development of 3-channel Pulse Wave Measurement System (3채널 맥파 측정 시스템 개발)

  • Kim, Eun-Geun;Heo, Hyun;Nam, Ki-Chang;Kang, Hee-Jung;Huh, Young
    • Proceedings of the IEEK Conference
    • /
    • 2008.06a
    • /
    • pp.1049-1050
    • /
    • 2008
  • It is difficult to measure the pulse wave in a short time because radial artery position and located depth are different depending on the person. In this paper, the pulse wave measurement system was developed using 3 channel piezoresistive sensor array to detect the most significant pulse wave. Augmentation Index(AI) and Heart Rate(HR) analysis are also available for predicting cardiovascular risks. The developed system is small and easy to use. And it is promising to be used as home healthcare device.

  • PDF

Implementation of 4 Channel Photo-Plethysmogram System(I) (4 채널의 Photo-plethysmogram 시스템 구현에 관한 연구(I))

  • Kim, Hyoung-Tae;Han, Soon-Chen;Kim, Jung-Kuk;Huh, Woong;Park, Young-Bae
    • Proceedings of the IEEK Conference
    • /
    • 2002.06e
    • /
    • pp.253-256
    • /
    • 2002
  • In this paper, we implement the volume pulse detection system which can quantitatively represent an artery elasticity. The system consists of transducer which has IRLED-photodiode detecter, temperature sensor, filters, preprocessing circuits, A/D converter, serial communication part and computer system. In order to presume the artery elasticity information we measure the volume pulse at four points and then evaluate the transition time, distance and the correlation coefficient of the pulse wave between the points. We test the system with 10 subjects during the week for basic experiment and obtain the data at four points. As the result of experiment, we can detect normalized volume pulse wave and evaluated parameter with effectively.

  • PDF

Digital System for Analyging Oriental Pulse Signals Designed (한방 맥파 분석을 위한 디지틸 시스템 설계)

  • 이준영;서현우;이정환;김정훈;이명호
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2000.10a
    • /
    • pp.544-544
    • /
    • 2000
  • From ancient times. the diagnosis method of the oriental medicine has been Performed by curing diseases by means of rectifying and adjusting the unbalance in the Physiological function of the five viscera and the six bowels of a human body. Diseases have been diagnosed by the condition of blood circulation that cycles a human body through blood vessels by dint of the vitality of the heart, Based on such a systematic pulse diagnosis method, the article presents parameters that will be beneficial to clinical application on the basis of its analysis of the filtering for eliminating noises from pulse signals inputted from sensor group the digital hardware dealing with signals necessary for recognition algorithm. and the structure of diagnosis algorithm and components of pulse waveform.

  • PDF

Reconstruction of Wavefront Aberration of 100-TW Ti:sapphire Laser Pulse Using Phase Retrieval Method

  • Jeong, Tae-Moon;Kim, Chul-Min;Ko, Do-Kyeong;Lee, Jong-Min
    • Journal of the Optical Society of Korea
    • /
    • v.12 no.3
    • /
    • pp.186-191
    • /
    • 2008
  • A phase retrieval method using an error reduction algorithm is developed for reconstructing a wavefront aberration of an 100-TW Ti:sapphire laser pulse from the measurement of a focal spot. The phase retrieval method can successfully reconstruct a wavefront aberration of a 100-TW Ti:sapphire laser pulse, and the reconstructed wavefront aberration shows a good agreement with the wavefront aberration measured with a wavefront sensor. The effect of the dynamic range and the intensity noise on the reconstruction is also investigated in reconstructing a wavefront aberration of an 100-TW Ti:sapphire laser pulse.

A Study on the PD Pulse Analysis and Noise Discrimination Method according to various sensors (센서에 따른 부분방전 펄스 분석 및 노이즈 제거 기법에 대한 연구)

  • Kim, Jeong-Tae;Rhee, Wook
    • Proceedings of the KIEE Conference
    • /
    • 2006.07c
    • /
    • pp.1469-1471
    • /
    • 2006
  • It is very important to discriminate noises such as air corona in measuring on-site partial discharges (PD). Therefore, in order to investigate the possibility of separating PD(partial discharge) and noises through the pulse analysis, pulse shapes measured by a resistive sensor and a HFCT were analyzed and PA(pulse analysis) were performed. For the purpose, the HFPD detection and PA system has been developed. Also void discharges and air corona were adopted as the artificial defect and noises, respectively.

  • PDF

Synchronous Visible Light Communication Systems Using 3-Level LED Modulation (3-Level LED 변조를 이용한 동기식 가시광통신 시스템)

  • Lee, Seong-Ho
    • Journal of Sensor Science and Technology
    • /
    • v.22 no.6
    • /
    • pp.421-427
    • /
    • 2013
  • In this paper, we introduce a new synchronous visible light communication system in which the synchronizing pulse and the data bits are simultaneously transmitted using a 3-level light signal. In the transmitter, the synchronizing pulse and the data bits modulate independently two identical visible LEDs, whose output lights add in free space, make 3-level optical signal. In the receiver, a photodiode detects the light and generates a 3-level output voltage, whose positive and negative part correspond to the synchronizing pulse and the data bits, respectively. The two signals are easily separated and recovered by a simple diode circuit. This configuration provides two independent VLC channels without any multiplexing technique, simplifies the circuit design and construction of synchronous VLC systems.

Illumination Control of LEDs in Visible Light Communication Using Manchester Code Transmission

  • Lee, Seong-Ho
    • Journal of Sensor Science and Technology
    • /
    • v.25 no.5
    • /
    • pp.303-309
    • /
    • 2016
  • In this paper, we introduce a new method for controlling the illumination of LEDs in visible light communication (VLC) by changing the duty cycle of Manchester code. When VLC data were transmitted in Manchester code, the average optical power of the LEDs was proportional to the duty cycle. In experiments, we controlled the illumination of a $3{\times}3$ LED array from 10% to 90% of its peak value by changing the duty cycle of the Manchester code. The synchronizing clocks required for encoding and decoding the Manchester code were supplied by pulse generators that were connected to a 220 V power line. All pulse generators made the same pulses with a repetition frequency of 120 Hz, and they were synchronized with the full-wave rectified voltage of the power line. This scheme is a very simple and useful method for constructing indoor wireless sensor networks using LED light.

The Image Sensor Operating by Thin Film Transistor (박막트랜지스터에 의해 구동되는 이미지센서)

  • Hur Chang-wu
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.10 no.1
    • /
    • pp.111-116
    • /
    • 2006
  • In this paper, the image sensor using the a-Si:H TFT is proposed. The optimum amorphous silicon thin film is deposited using plasma enhanced chemical vapor deposition (PECVD). TFT and photodiode both with the thin film are fabricated and form image sensor. The photodiode shows that Idark is $10^{-12}A$, Iphoto is $10^{-9}A$ and Iphoto/Idark is $10^3$, respectively. In the case of a-Si:H TFT, it indicates that Ion/Ioff is $10^6$, the drain current is a few ${\mu}A$ and Vth is $2\~4$ volts. For the analysis on the fabricated image sensor, the reverse bias of -5 voltage in ITO of photodiode and $70{\mu}sec$ pulse in the gate of TFT are applied. The image sensor with good property was conformed through the measured photo/dark current.