• Title/Summary/Keyword: pulse electric field

Search Result 179, Processing Time 0.024 seconds

Application of a Pulse Electric Field to Cross-flow Ultrafiltration of Protein Solution

  • Kim, Hyong-Ryul;Lee, Kisay
    • Biotechnology and Bioprocess Engineering:BBE
    • /
    • v.4 no.1
    • /
    • pp.46-50
    • /
    • 1999
  • The application of pulsed electric field was investigated in the crossflow ultrafiltration of BSA (bovine serum albumn) to economize the application time of electric current as well as to avoid inherent problems of long-term application of electric field. During the application of various cyclic patterns of pulsed electric current, the averaged filtration flowrate and the degree of concentration were maintained higher than those obtained in the absence of electric current application. The temperature increase, pH change, and BSA loss by electrodeposition were all negligible during the operation. The averaged filtration flowrate increased as the ON/OFF duration ratio of electric current was higher and as the period of ON/OFF cycle was shorter. The re-establishment of concentration polarization was dependent to the duration of current OFF state and, therefore, a longer duration of OFF state was not favorable in maintaining higher filtration flow rate. Although the averaged filtration flowrate was enhanced as the magnitude of electric current increased, the flowrate enhancement became smaller as the magnitude of current value above which the degree of electrokinetic depolarization is no further improved.

  • PDF

A Damped Sinusoidal Electromagnetic Pulse Generator using a Charged Line (충전선로를 이용한 Damped Sinusoidal 전자기펄스 발생장치)

  • Ryu, Ji-Heon
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.9 no.2 s.25
    • /
    • pp.136-142
    • /
    • 2006
  • A damped sinusoidal electromagnetic pulse generator was designed, fabricated and tested. The pulse generator consisted of an oscillator(a spark gap switch and an initially charged low impedance line) and a high impedance antenna. This generator was capable of producing damped sinusoidal pulses at closure of the spark gap switch. A Marx generator was employed to supply the Pulse generator with high voltage pulses. While the pulse generator was provided with the high voltage pulses of 200kV from the Marx generator, its output power was maximized by controlling the pressure of the gas contained in the spark gap switch. The output power of the damped sinusoidal electromagnetic pulse oscillator was 1.3GW and the amplitude of electric field radiated from the pulse generator was 4kV/m at the range of 25m.

A Study on the Design of Nonlinear Wire Antennas with Ripple-Type Wide Band Characteristics for Improvement of Pulse Radiation Ability (펄스 복사 능력 개선을 위한 리플형 광대역특성을 갖는 비선형 와이어안테나 설계에 관한 연구)

  • Kim, Yeon-Seon;Park, Ui-Jun
    • Journal of the Institute of Electronics Engineers of Korea TC
    • /
    • v.39 no.3
    • /
    • pp.150-157
    • /
    • 2002
  • A nonlinear shaping method for a wire antenna is presented to improve the limited pulse radiation ability due to the frequency characteristics with nulls which are found in the conventional straight or V antennas. The developed scheme is based on the minimization of frequency-dependence of the radiated electric field intensity over wide band, hence giving the ripple-type frequency characteristics. It is shown that the synthesized shape has more advantage in the case of shorter pulse. That is, we found that for shorter pulse exciting, the radiated peak value of the synthesized antenna is larger than that of the conventional linear antenna. The inverse discrete Fourier transform based on the moment method is used for the transient analysis of current distribution and far field electric field.

Effect of the Electric Field on the Plant Protoplasts During Cell Fusion (세포융합시 전계하에서 식물세포가 받는 영향에 관한연구)

  • Lee, Sang-Hoon;Lee, Yon-Min;Cha, Hyeon-Cheol
    • Journal of Biomedical Engineering Research
    • /
    • v.17 no.2
    • /
    • pp.173-178
    • /
    • 1996
  • The objective of this paper is to investigate the effect of AC field on the protoplast of plant cells. The results of investigation will be the basis for the development of etectric cell fusion device. For the experiment, we made the electrode and AC and DC pulse generator and observed the behavior of the protoplasts through the inverted microscope which is connected to the monitor and video recorder by the CCD camera. As a result, the numbers of rotating, moving and destructed protoplasts and viability of the protoplasts have close relation to the amplitude of AC field, while the rotation rate is closely related to the frequency of AC pulse.

  • PDF

A Study on Operation Characteristics of Three Electrode Trigger Gap Switch (3전극 트리거 갭 스위치 동작특성에 관한 연구)

  • Hong, Tae-Yun;Han, Sang-Bo
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.67 no.4
    • /
    • pp.549-553
    • /
    • 2018
  • The applications of the pulse power technology are expanding and the necessity of a large current switch as a core component of pulsed power is increasing. A trigger gap switch composed of three electrodes was fabricated and the discharge characteristics were studied according to the change of the pressure, the shape of the main electrode, and the gap distance when the trigger pulse was applied. As a main result, the stable operation range was confirmed through the discharge inception voltage according to the gap distance and electric field analysis was performed in the same structure to confirm the electric field value of the discharge inception voltage.

The study of phase-change with electric field on chalcogenide thin films (칼코게나이드 박막의 전기적 펄스에 의한 상변화 특성 연구)

  • Yang, Sung-Jun;Shin, Kyung;Lee, Ki-Nam;Chung, Hong-Bay
    • Proceedings of the KIEE Conference
    • /
    • 2003.10a
    • /
    • pp.120-122
    • /
    • 2003
  • We have been investigated phase-change with temperature and electric field in chalcogenide $Ge_2Sb_2Te_5$ thin film. $T_c$(crystallization temperature) is confirmed by measuring the resistance and conductivity with the varying temperature on the hotplate. We have measured I-V characteristics with $Ge_2Sb_2Te_5$ chalcogenide thin film. It is compared with I-V characteristics after impress the variable pulse. The pulse has variable height and duration that used voltage and current source.

  • PDF

The Study of Phase-change with Temperature and Electric field in Chalcogenide Thin Film

  • Yang, Sung-Jun;Shin, Kyung;Park, Jung-Il;Lee, Ki-Nam;Chung, Hong-Bay
    • Transactions on Electrical and Electronic Materials
    • /
    • v.4 no.5
    • /
    • pp.24-27
    • /
    • 2003
  • We have been investigated phase-change with temperature and electric field in chalcogenide Ge$_2$Sb$_2$Te$\sub$5/ thin film. T$\sub$c/(crystallization temperature) is confirmed by measuring the resistance with the varying temperature on the hotplate. We have measured I-V characteristics with Ge$_2$Sb$_2$Te$\sub$5/ chalcogenide thin film. It is compared with I-V characteristics after impress the variable pulse. The pulse has variable height and duration.

The Development of Hot Carrier Immunity Device in NMOSFET's (NMOSFET에서 핫-캐리어 내성의 소자 개발)

  • ;;;;Fadul Ahmed Mohammed
    • Proceedings of the IEEK Conference
    • /
    • 2002.06b
    • /
    • pp.365-368
    • /
    • 2002
  • WSW(Wrap Side Wall) is proposed to decrease junction electric field in this paper. WSW process is fabricated after first gate etch, followed NMI ion implantation and deposition & etch nitride layer New WSW structure has buffer layer to decrease electric field. Also we compared the hot carrier characteristics of WSW and conventional. Also, we design a test pattern including pulse generator, level shifter and frequency divider, so that we can evaluate AC hot carrier degradation on-chip.

  • PDF

Analysis of an External Stimulator's Impact on the Heart (체외 전기자극기가 심장에 미치는 영향의 분석 및 평가)

  • Kim, Mun-Soo;Choe, Seung-Wook
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.35 no.11
    • /
    • pp.1213-1217
    • /
    • 2011
  • Electric stimulators are used for various treatments, such as for pain relief and to improve rehabilitation in and out of the hospital. However, if the stimulation pulse affects the patient's heart, it can cause critical cardiac disorders such as arrhythmia or ventricular fibrillation. As a result, it must be ensured that the transmission length of the stimulation pulse does not exceed the proper range in the design of an electric stimulator. Furthermore, every anticipated risk factor must be monitored in in-vitro and in-vivo experiments. A new stimulator was designed to supply continuous 0.001 J stimulation pulses at a rate of 60 pulses per second. To evaluate the safety of the new electric stimulator and to measure its energy transfer and pulse transmission length, we built a conduction model that was filled with saline and measured the electric field at various positions in response to real stimulations. In an animal experiment with two pigs, heart disorders were induced by applying electric stimulation to tissues near the heart. These heart disorders were different from the result obtained with 9 V DC stimulation.

Study of PD Location in Generators by PD Pulses Propagation

  • Cheng, Yang-Chun;Li, Cheng-Rong;Wang, Wei
    • Transactions on Electrical and Electronic Materials
    • /
    • v.7 no.5
    • /
    • pp.252-256
    • /
    • 2006
  • When a partial discharge takes place at the stator of a generator, the electrical pulse will propagate along the stator bars and the capacitor chains formed by the end part of the stator winds. On the first path, the pulse propagates as a travel wave at slow speed. On the second path, the pulse propagates at quick speed. Based on the data of the experiments on a real 50 MW steam generator, the author has found the pulses can propagate by magnetic field of the stator winding. It was studied that how to locating the partial discharge by signals coming from the different paths, including the features of signals on the two paths at time domain and frequency domain, the measurement frequency rang of the signals, the blind area, the advantage and disadvantage of this method.