• 제목/요약/키워드: pulse discharge

검색결과 666건 처리시간 0.029초

Mica/Epoxy 복합 절연계통의 부분방전 특성과 열화 관계에 관한 연구(I) (A Study on the Relationship between Aging and Partial Discharge Characteristics of the Mica/Epoxy Composite Insulation Systems (l))

  • 강동식;이우영;박정후;곽영순;김길용
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1992년도 하계학술대회 논문집 B
    • /
    • pp.976-979
    • /
    • 1992
  • There are lots of problem which are delaminations and partial discharge of insulation materials in high-voltage rotating machines caused by mechanical, electrical and thermal aging. Several experiments have been aiming at finding the useful diagnostic parameters from the partial discharge characteristics by applying a new measurement techniques. This paper deals with the partial discharge characteristics (pulse height, pulse angle, pulse frequency spectrum and time interval), which may be a useful diagnostic concept in predicting insulation condition of mica/epoxy composite insulation materials, by using several measurement equipments (frequency spectrum analyzer. multichannel analyzer and time interval analyzer).

  • PDF

코로나방전을 이용한 배기가스중의 Nox제거 (Nox reduction of exhaust gas using corona discharge)

  • 김종달;박재윤;고희석
    • E2M - 전기 전자와 첨단 소재
    • /
    • 제8권6호
    • /
    • pp.721-726
    • /
    • 1995
  • In this paper, reduction characteristics of NOx gas produced from diesel engine combustion is studied by using pulse corona discharge. Nox concentration of 1900ppm (NO 1870, NO$\sub$2/ 30 ppm, N$\sub$2/ balance gas) was controlled in a fixed quantity of 280ppm, using a flow meter. Reactors are composed of cylinder type. NOx reduction rate is investigated with discharge electrode diameter[0.5,1,3,4.phi.], reactor length [130,300mm], reactor materials[Copper, Poly Vinyl Chloride] and Input voltage[DC, AC, DC Pulse square voltage]. In the result, NOx reduction rate is the best of all in copper reactor, small electrode diameter[0.5.phi.], DC pulse voltage and long reactor[300mm]. Then Teduction rate of NOx is about 93%.

  • PDF

부분방전 교정펄스 발생기의 표준화 시스템구축과 불확도 (Setup and Uncertainty of Standard System for Calibrating Pulse Generator of Partial Discharge)

  • 김광화;이상화;이헌진;강동식
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2009년도 제40회 하계학술대회
    • /
    • pp.1355_1357
    • /
    • 2009
  • This paper describes the standard system for calibrating pulse generator of partial discharge(PD) and its uncertainty. The system is consisted of digital pulse generator, digital recorder and evaluation software. The uncertainty requirement of calibrator charge is less than $\pm$ (0.1pC + 0.03q) and that of pulse duration is less than $\pm$ 10 %. The system can generate various kind of calibration pulses such as single pulse, double pulses, oscillation pulse, long-duration pulse, random pulses and evaluate their uncertainty.

  • PDF

Effect of Auxiliary Address Pulse on Face-to-face Sustain Electrode Structure in AC-PDP

  • Kim, Bo-Sung;Tae, Heung-Sik
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 한국정보디스플레이학회 2007년도 7th International Meeting on Information Display 제7권1호
    • /
    • pp.605-608
    • /
    • 2007
  • The discharge characteristics of the face-to-face sustain electrode structure employing auxiliary address pulse are investigated under a sustain driving frequency of 20 kHz and various auxiliary address pulse widths (500 ns, $1{\mu}s$, $2\;{\mu}s$) in the 6-in. test panel (42-in. Full HD grade) with a pressure of 450 Torr and a 4 % Xe-content. The luminance and the luminous efficiency at the auxiliary address pulse width of 500 ns are improved more than these of $1\;{\mu}s$ and $2\;{\mu}s$. At the auxiliary address pulse width of 500 ns, the luminous efficiency shows about 0.96 lm/W at the auxiliary pulse of 90 V and the sustain voltage of 260 V.

  • PDF

LCD 백라이트용 Xe계 플라즈마 평판 램프의 구동 전압 Pulse의 조건에 따른 방전 특성 연구 (Discharge Characteristics of Xe Plasma Flat Lamp for LCD Backlight According to Operating Voltage Pulse)

  • 권은미;김혁환;이원종
    • 한국재료학회지
    • /
    • 제13권4호
    • /
    • pp.271-278
    • /
    • 2003
  • Conventional backlight for liquid crystal display (LCD) uses mercury which leads to environmental pollution. In this study, characteristics of AC coplanar type mercury-free plasma flat lamp have been studied. Pollution-free Xe-He is adopted as a discharge gas system. Since the Xe gas has a lower efficiency in generating vacuum ultraviolet (VUV) than mercury, the improvement of luminance and luminous efficiency in the Xe gas system is very important. The electrode, dielectric, and phosphor layers constituting lamp are formed on the bottom glass by the screen printing method. The effects of pulse shape, on-time, and pulse frequency on the luminance and luminous efficiency have been examined. For Xe(5%)-He gas, the lamp exhibits higher efficiency with sharper pulse shape, higher peak voltage, and shorter pulse on-time (up to 2 $\mu\textrm{s}$). Higher efficiency and lower consumption of power were obtained at 30 kHz than at 60 kHz. The collision of ion to bottom electrodes is a dominant factor to raise the lamp temperature. Therefore the high voltage and low current discharge system is necessary for reduction of the lamp temperature as well as for enhancement of the luminous efficiency.

Multi-discharge 방식의 long-pulse 고체 레이저의 출력 특성에 대한 연구 (A study on the output characteristics of long-pulse Nd:YAG laser of sequential discharge of method)

  • 송금영;곽수영;홍정환;노기경;김희제
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2002년도 춘계합동학술대회 논문집
    • /
    • pp.168-171
    • /
    • 2002
  • In this study. a solid-state laser system adopting a sequential discharge method in which three flashlamps are turned on sequently was designed and fabricated to examine the pulse width and the pulse shape of the laser beams depending upon the changes in the lamp turn-on time. That is, this study shows a technology that makes it possible to make various pulse shapes by turning on three flashlamps sequently with the aid of a PIC one-chip microprocessor. With this technique, the lamp turn-on delay time can be varied more diversely from a to lamp and the real-time control is possible with an external keyboard, enabling various pulse shapes. In addition, longer pulses can be more widely used for industrial processing and lots of medical purposes.

  • PDF

전력 케이블에서 발생되는 방전 신호의 분포패턴에 관한 특성 분석 (Properties on the Distribution Pattern of Discharge Signals Generated in the Power Cable)

  • 소순열;홍경진;이우기;이동인;김태성
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 1998년도 춘계학술대회 논문집
    • /
    • pp.13-18
    • /
    • 1998
  • After Computer-based PD measurement was referred in the 1970's, the new technology and a number of digital system have been studied. And the selection of PD patterns, extraction of relevant information for PD recognition are discussed because the number of pulse as a function of discharge magnitude and discharge pulse as a function of the power frequency cycl4e offer the information of the aging insulation. This paper investigates the discharge phase($\phi$) and magnitude(q), as well as the number of discharge(n) with regard to discharge signals generated in power cable. Therefore, according to properties analysis on the distribution of $\phi$ , q and n, it is able to apply in the aging analysis of power cable which visual observation is impossible and distribution change of discharge signals offers much information for risk degree on aging progress of insulation materials.

  • PDF

PA Map(Pulse Analysis Map)을 이용한 새로운 부분방전 패턴인식에 관한 연구 (A Study on the New Partial Discharge Pattern Analysis System used by PA Map (Pulse Analysis Map))

  • 김지홍;김정태;김진기;구자윤
    • 전기학회논문지
    • /
    • 제56권6호
    • /
    • pp.1092-1098
    • /
    • 2007
  • Since one decade, the detection of HFPD (High frequency Partial Discharge) has been proposed as one of the effective method for the diagnosis of the power component under service in power grids. As a tool for HFPD detection, Metal Foil sensor based on the embedded technology has been commercialized for mainly power cable due to its advantages. Recently, for the on-site noise discrimination, several PA (Pulse analysis) methods have been reported and the related software, such as Neural Network and Fuzzy, have been proposed to separate the PD (Partial Discharge) signals from the noises since their wave shapes are completely different from each other. On the other hand, the relevant fundamental investigation has not yet clearly made while it is reported that the effectiveness of the current methods based on PA is dependant on the types of sensors. Moreover, regarding the identification of the vital defects introducible into the Power Cable, the direct identification of the nature of defects from the PD signals through Metal Foil coupler has not yet been realized. As a trial for solving above shortcomings, different types of software have been proposed and employed without any convincing probability of identification. In this regards, our novel algorithm 'PA Map' based on the pulse analysis is suggested to identify directly the defects inside the power cable from the HFPD signals which is output of the HFCT and metal foil sensors. This method enables to discriminate the noise and then to make the data analysis related to the PD signals. For the purpose, the HFPD detection and PA (Pulse Analysis) system have been developed and then the effect of noise discrimination has been investigated by use of the artificial defects using real scale mockup. Throughout these works, our system is proved to be capable of separating the small void discharges among the very large noises such as big air corona and ground floating discharges at the on-site as well as of identifying the concerned defects.

대기압 플라즈마 발생시 인가전압의 상승시간에 따른 영향 (Effect of Rise Time of a Pulse Bias Voltage on Atmospheric Plasma Generation)

  • 김재혁;진상일;김영민
    • 전기학회논문지
    • /
    • 제57권7호
    • /
    • pp.1218-1222
    • /
    • 2008
  • We investigate the effect of rise time of a pulse bias voltage on atmospheric plasma generation. With the faster rise time of the pulse bias, the glow discharge appears to be more uniformly generated along the electrodes. I-V measurement confirms that higher loading power can be obtained using the faster rise time. A new understanding for atmospheric plasma generation at a micro-gap electrode is suggested.

진공관 전원방식 30 W급 구리증기레이저 (A 30 W Copper Vapor Laser Using a Vacuum Tube Based Pulse Generator)

  • 진정태;차병헌;김철중;이흥호
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제52권12호
    • /
    • pp.568-572
    • /
    • 2003
  • A longitudinal discharge heated copper vapor laser with internal diameter 28 mm and discharge length 1.3 m has been constructed and tested. At the discharging voltage 15.2 kV, pulse repetition rate 10 kHz, buffer gas pressure 40 mbar, and internal temperature of the laser plasma tube $1520^{\circ}C$, it delivers more than 30 W average laser outputs.