• Title/Summary/Keyword: pulse discharge

Search Result 665, Processing Time 0.026 seconds

Voltage Source Resonant Inverter for Excimer Gas Discharge Load

  • Koudriavtsev Oleg;Nakaoka Mutsuo
    • Proceedings of the KIPE Conference
    • /
    • 2001.10a
    • /
    • pp.89-92
    • /
    • 2001
  • Silent gas discharge method has been widely applied for ozone production, ultraviolet light and UV laser generation. Since ozone and ultraviolet applications have tendency to spread widely in industry, the development of efficient and low-cost power supply for such systems is a task of great impotency. This paper introduces high-frequency inverter type mode power supply designed for ozone generation tube and ultraviolet generation excimer lamp and considerations on this inverter and pulse density modulation control strategy applied in it.

  • PDF

Discrimination of Air PD Sources Using Time-Frequency Distributions of PD Pulse Waveform (부분방전 펄스파형의 시간-주파수분포를 이용한 기중부분방전원의 식별)

  • Lee Kang-Won;Kang Seong-Hwa;Lim Ki-Joe
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.54 no.7
    • /
    • pp.332-338
    • /
    • 2005
  • PD(Partial Discharge) signal emitted from PD sources has their intrinsic features in the region of time and frequency STFT(Short Time Fourier Transform) shows time-frequency distribution at the same time. 2-Dimensional matrices(33$\times$77) from STFT for PD pulse signals are a good feature vectors and can be decreased in dimension by wavelet 2D data compression technique. Decreased feature vectors(13$\times$24) were used as inputs of Back-propagation ANN(Artificial Neural Network) for discrimination of Multi-PD sources(air discharge sources(3), surface discharge(1)). They are a good feature vectors for discriminating Multi-PD sources in the air.

Comparative analysis of PRPD method and UHF sensor method for Partial Discharge in air (공기중 부분방전에 대한 PRPD측정법과 UHF센서측정법의 비교분석)

  • Lee, K.W.;Lee, Y.H.;Park, S.H.;Jang, D.U.;Kang, S.H.;Lim, K.J.
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2002.07b
    • /
    • pp.882-885
    • /
    • 2002
  • Assessing the condition of air insulation by measuring electromagnetic wave generated in it by partial discharges gives warning of developing faults and breakdown which may give some bad effects to other thing concerned with it. Electromagnetic wave are taken from UHF antenna with 20k ~ 2GHz frequency range. The signal waveform and FFT(Fast Fourier Transform) results from UHF antenna for PD(partial discharge) generated from two different electrode(needle-plane, needle-needle) configurations are shown and it is processed by using PRPD($\Phi-q-n$ distribution) method. Cumulative pulse sequence during 100 period is compared with PRPD method. This also will show the possibility of making apparent distinction between two PD sources.

  • PDF

A Study on Partial Discharge Measurement using Optical Fiber Sensors (광섬유 센서를 이용한 부분방전 측정연구)

  • Lee, June-Ho;Lee, Cheol-Kyou
    • Proceedings of the KIEE Conference
    • /
    • 1998.11c
    • /
    • pp.922-924
    • /
    • 1998
  • In this paper, an optical fiber sensor(OF sensor) utilizing the principal of Mach-Zehnder interferometer were proposed to detect the partial discharge signals in insulating oil. At first the AC breakdown signals were detected to check the response of the OF sensor. The detected signals from OF sensor was consistent with that from current probe. After the response checking, simultaneous measurements and continuous recording were made of electrical and the OF sensor signals from partial discharge(PD) produced by IEC(b) electrode system immersed in insulating oil. The continuous recording made it possible to extract basic quantities of PD from the OF sensor signals, such as pulse phase and pulse amplitude distribution. Through the signal analysis, the absolute peaks of the OF sensor PD signal was found to be increased with the amplitude of electrical signals, and these results mean that there is a strong correlation between OF sensor and electrical PD signals. It was demonstrated that the OF sensor in this research had a possibility to detect the PD signals in power apparatus.

  • PDF

Improvement of luminous efficiency through new cell structure and driving pulse

  • Ko, Sang-Woo;Yang, Sung-Soo;Kim, Hyun-Chul;Mukherjee, Sudeshna;Lee, Jae-Koo
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2003.07a
    • /
    • pp.714-717
    • /
    • 2003
  • We have suggested several plasma display panel (PDP) cell structures for high luminance and low power consumption by our two-and three-dimensional fluid simulation codes. Generally, to improve luminous efficiency and discharge efficiency, it is known that it is lucrative to use long discharge path and to form low electric field. However, the problems are how to implement them effectively in the small PDP cell. Therefore, unlike conventional model, we suggest Front Three Electrodes (FTE) model. In this model, we tried to make long and V-shaped discharge path by geometry changes and driving pulse variations. Consequently, from our simulation results based on the model above, luminous efficiency has improved about 2.6 times.

  • PDF

Voltage Source Resonant Inverter for Excimer Gas Discharge Load

  • Koudriavtsev, Oleg;Nakaoka, Mutsuo
    • Journal of Power Electronics
    • /
    • v.2 no.3
    • /
    • pp.206-211
    • /
    • 2002
  • Silent gas discharge method has been widely applied fur ozone production, ultraviolet light and UV laser generation. Since ozone and ultraviolet applications have tendency to spread widely in industry, the development of efficient and low - cost power supply for such systems is an important task at present. This paper introduces high-frequency inverter type mode power supply designed fur ozone generation tube and ultraviolet generation excimer lamp and considerations on the design of the inverter and pulse density modulation control strategy applied in it.

Detection and Location of Partial discharge in Transformers Using Logoski coil and Ultrasonic sensor (로고스키 코일과 초음파 센서를 이용한 변압기내 부분방전 탐지 및 위치검출)

  • Kwak, Hee-Ro;Kim, Jae-chul;Kim, Eung-Sang;Han, Min-Koo;Kwan, Tae-Won;Yoon, Young-Beum
    • Proceedings of the KIEE Conference
    • /
    • 1990.07a
    • /
    • pp.279-282
    • /
    • 1990
  • This paper describes an nstrument for the detection and geometric location of partial discharge(PD) sources in transformers. This instrument measures electric current pulses and ultrasonic pulses simultaneously, counts the number of electrical pulse and determines the geometric location of PD in transformers. It was found that there is a relationship between partial discharge magnitude and pulse repetition rate when the applied test voltage and oil temperature were varied. Through the laboratory test using model transformer, it was clarified that this detector could be used, satisfactory for detecting and locating of PD in the transformer.

  • PDF

The electrical and optical properties of Xe plasma in flat lamp (평판형 광원에서 제논(Xe) 플라즈마의 전기적 광학적 특성 연구)

  • Pack, Gwang-Hyeon;Yang, Jong-Kyung;Lee, Jong-Chan;Chio, Yong-Sung;Park, Dae-Hee
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2005.05b
    • /
    • pp.60-64
    • /
    • 2005
  • Discharge of the flat lamp lighting source research are requested very much. For improving brightness, life time, efficiency of flat lamp, plasma diagnosis of the flat lamp lighting source to understand property of lighting source is very important, distance of discharge electrode is 5.5mm and width is 16.5mm, we measured electron temperature and electron density measured with single langmuir probe in flat lamp, we tested the discharge from 100 Torr to 300 Torr pressure, the Pulse is rectangular pulse with frequency 20kHz and Duty ratio 20%. Resultly, electron temperature decreases and electron density increase as increase the gas pressure and electron temperature decreases and electron density increase as increase the voltage.

  • PDF

An Analysis of Partial Discharge signal Using Wavelet Transforms (웨이블렛 변환을 이용한 부분 방전 신호 분석)

  • 박재준;장진강;임윤석;심종탁;김재환
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1999.05a
    • /
    • pp.169-172
    • /
    • 1999
  • Recently, the wavelet transform has been a new and powerful tool for signal processing. It is more suitable specially for the feature extraction and detection of non-stationary signals than traditional methods such as, the Fourier Transform(FT), the Fast Fourier Transform(FFT) and the Least Square Method etc. because of the characteristic of the multi-scale analysis and time-frequency domain localization. The wavelet transform has been developed for the analysis of PD pulse signal to raise in the progress of insulation degradation. In this paper, the wavelet transform was applied to one foundational method for feature extraction. For the obtain experimental data, a computer-aided partial discharge measurement system with a single acoustic sensor was used. If we are applying to the neural network method the accumulated data through the extracted feature, it is expected that we can detect the PD pulse signal in the insulation materials on the on-line.

  • PDF

Dielectric Barrier Discharge for Ultraviolet Light Generation and Its Efficient Driving Inverter Circuit

  • Oleg, Kudryavtsev;Ahmed, Tarek;Nakaoka, Mutsuo
    • KIEE International Transactions on Electrophysics and Applications
    • /
    • v.4C no.3
    • /
    • pp.101-105
    • /
    • 2004
  • The efficient power MOSFET inverter applied for a simple and low cost power supply is proposed for driving the dielectric barrier discharge (DBD) lamp load. For decades, the DBD phenomenon has been used for ozone gas production in industry. In this research, the ultraviolet and visible light sources utilizing the DBD lamp is considered as the load for solid-state high frequency power supply. It is found that the simple voltage-source single-ended quasi-resonant ZVS inverter with only one active power switch could effectively drive this load with the output power up to 700 W. The pulse density modulation based control scheme for the single-ended quasi-resonant ZVS inverter using a low voltage and high current power MOSFET switching device is proposed to provide a linear power regulation characteristic in the wide range 0-100% of the full power as compared with the conventional control based Royer type parallel resonant inverter type power supplies.