• Title/Summary/Keyword: pulse count

Search Result 86, Processing Time 0.023 seconds

Comparison of the Quantulus 1220 and 300SL Liquid Scintillation Counters for the Analysis of 222Rn in Groundwater

  • Kim, Hyuncheol;Jung, Yoonhee;Lee, Wanno;Choi, Guen-Sik;Chung, Kun Ho;Kang, Mun Ja
    • Journal of Radiation Protection and Research
    • /
    • v.41 no.4
    • /
    • pp.395-401
    • /
    • 2016
  • Background: Liquid scintillation counters (LSCs) are commonly used as an analytical method for detecting $^{222}Rn$ in groundwater because they involve a simple sample pretreatment and allow high throughout with an autosampler. The Quantulus 1220 is the best-selling LSC in Korea, but its production was stopped. Recently, a new type of LSC, the 300SL, was introduced. In this study, the 300SL was compared with the Quantulus 1220 in order to evaluate the ability of each apparatus to detect $^{222}Rn$ in groundwater. Materials and Methods: The Quantulus 1220 and 300SL were used to detect the presence of $^{222}Rn$. Radon gas was extracted from a groundwater sample using a water-immiscible cocktail in a LSC vial. The optimal analytical conditions for each LSC were determined using a $^{222}Rn$ calibration source prepared with a $^{226}Ra$ source. Results and Discussion: The optimal pulse shape analysis level for alpha and beta separation was 80 for the Quantulus 1220, and the corresponding pulse length index was 12 in the 300SL. The counting efficiency of the Quantulus 1220 for alpha emissions was similar to that of the 300SL, but the background count rate of the Quantulus 1220 was 10 times lower than that of the 300SL. The minimum detectable activity of the Quantulus 1220 was $0.08Bq{\cdot}L^{-1}$, while that of the 300SL was $0.20Bq{\cdot}L^{-1}$. The analytical results regarding $^{222}Rn$ in groundwater were less than 10% different between these LSCs. Conclusion: The 300SL is an LSC that is comparable to the Quantulus 1220 for detecting $^{222}Rn$ in groundwater. Both LSCs can be applied to determine the levels of $^{222}Rn$ in groundwater under the management of the Ministry of Environment.

A Capacitance Deviation-to-Time Interval Converter Based on Ramp-Integration and Its Application to a Digital Humidity Controller (램프-적분을 이용한 용량치-시간차 변환기 및 디지털 습도 조절기에의 응용)

  • Park, Ji-Mann;Chung, Won-Sup
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.37 no.12
    • /
    • pp.70-78
    • /
    • 2000
  • A novel capacitance deviation-to-time interval converter based on ramp-integration is presented. It consists of two current mirrors, two schmitt triggers, and control digital circuits by the upper and lower sides, symmetrically. Total circuit has been with discrete components. The results show that the proposed converter has a linearity error of less than 1% at the time interval(pulse width) over a capacitance deviation from 295 pF to 375 pF. A capacitance deviation of 40pF and time interval of 0.2 ms was measured for sensor capacitance of 335 pF. Therefore, the high-resolution can be known by counting the fast and stable clock pulses gated into a counter for time interval. The application of a novel capacitance deviation-to time interval converter to a digital humidity controller is also presented. The presented circuit is insensitive to the capacitance difference in disregard of voltage source or temperature deviation. Besides the accuracy, it features the small MOS device count integrable onto a small chip area. The circuit is thus particularly suitable for the on-chip interface.

  • PDF

Radioassay of Multiple Beta-Labeled Mixtures using Least-Square Method (최소자승법을 이용한 다수 베타 방출 핵종 혼합물의 방사능 분석)

  • Seon, Kwang-Il;Nam, Uk-Won;Kong, Kyoung-Nam;Kim, Chang-Kyu;Lee, Dong-Myung;Lee, Sang-Kook
    • Journal of Radiation Protection and Research
    • /
    • v.26 no.4
    • /
    • pp.375-384
    • /
    • 2001
  • It is possible to count and perform quench correction on two ${\beta}$ -label samples so long as the maximum ${\beta}$-energies are sufficiently different. However, when 4he conventional technique is applied to the radioassay of a mixture of more than three nuclides, the reliability of the activities determined is considerably reduced, resulting from the large overlapping of liquid scintillation pulse height distributions of each nuclide. A technique that allows the activities of multiple ${\beta}$-labeled samples to be radioassayed was proposed by using the least square method. The technique was applied to mixture samples of $^3H,\;^{14}C,\;^{36}Cl$, and $^{90}Sr$. The analytical values were in good agreement with the reference values within 7% relative error.

  • PDF

The detection efficiency study of NaI(Tl) scintillation detector with the different numbers of SiPMs

  • Wang, Bao;Zhang, Xiongjie;Wang, Qingshan;Wang, Dongyang;Li, Dong;Xiahou, Mingdong;Zhou, Pengfei;Ye, Hao;Hu, Bin;Zhang, Lijiao
    • Nuclear Engineering and Technology
    • /
    • v.54 no.7
    • /
    • pp.2564-2571
    • /
    • 2022
  • SiPMs are generally coupled into whole columns in gamma energy spectrum measurement, but the relationship between the distribution of whole SiPM columns and the energy resolution of the measured energy spectra is rarely reported. In this work, ∅ 3 × 3 inch NaI scintillator is placed on an 8 × 8 SiPM array, and the energy resolution of the 137Cs peak at 662 keV corresponding to the γ-ray is selected as a reference. Each SiPM is switched to explore the influence of the number of SiPM arrays, distribution position, and reflective layer on the energy resolution of SiPMs. Results show that without coupling, the energy resolution is greatly improved when the number of SiPMs ranges from 4 to 32. However, after 32 slices (the area covered by SiPMs relative to the scintillator reaches 25.9%), the improvement in energy resolution and total pulse count is not obvious. In addition, the position of SiPMs relative to the scintillator does not exert much impact on the energy resolution. Results also indicate that by adding a reflective film (ESR), the energy resolution of the tested group increases by 10.38% on average. This work can provide a reference for the design and application of miniaturized SiPM gamma spectrometers.

Safe Discharge Criteria After Curative Gastrectomy for Gastric Cancer

  • Guner, Ali;Kim, Ki Yoon;Park, Sung Hyun;Cho, Minah;Kim, Yoo Min;Hyung, Woo Jin;Kim, Hyoung-Il
    • Journal of Gastric Cancer
    • /
    • v.22 no.4
    • /
    • pp.395-407
    • /
    • 2022
  • Purpose: This study aimed to investigate the relationship between clinical and laboratory parameters and complication status to predict which patients can be safely discharged from the hospital on the third postoperative day (POD). Materials and Methods: Data from a prospectively maintained database of 2,110 consecutive patients with gastric adenocarcinoma who underwent curative surgery were reviewed. The third POD vital signs, laboratory data, and details of the course after surgery were collected. Patients with grade II or higher complications after the third POD were considered unsuitable for early discharge. The performance metrics were calculated for all algorithm parameters. The proposed algorithm was tested using a validation dataset of consecutive patients from the same center. Results: Of 1,438 patients in the study cohort, 142 (9.9%) were considered unsuitable for early discharge. C-reactive protein level, body temperature, pulse rate, and neutrophil count had good performance metrics and were determined to be independent prognostic factors. An algorithm consisting of these 4 parameters had a negative predictive value (NPV) of 95.9% (95% confidence interval [CI], 94.2-97.3), sensitivity of 80.3% (95% CI, 72.8-86.5), and specificity of 51.1% (95% CI, 48.3-53.8). Only 28 (1.9%) patients in the study cohort were classified as false negatives. In the validation dataset, the NPV was 93.7%, sensitivity was 66%, and 3.3% (17/512) of patients were classified as false negatives. Conclusions: Simple clinical and laboratory parameters obtained on the third POD can be used when making decisions regarding the safe early discharge of patients who underwent gastrectomy.

Identification of Void Diameters for Cast-Resin Transformers (몰드변압기의 보이드 결함 크기 판별)

  • Jeong, Gi-woo;Kim, Wook-sung
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2022.10a
    • /
    • pp.570-573
    • /
    • 2022
  • This paper presents the identification of void diameters for a cast-resin transformer using an artificial neural network (ANN) model. A PD signal was measured by the Rogowski coil sensor which has the planar and thin structures fabricated on a printed circuit board (PCB), and the PD electrode system was fabricated to simulate a PD defect by a void. In addition, void samples with different diameters were fabricated by injecting air in a cylindrical aluminum frame using a syringe during the epoxy curing process. To identify the diameter of void defects, PD characteristics such as the discharge magnitude, pulse count, and phase angle were extracted and back propagation algorithm (BPA) was designed using virtual instrument (VI) based on the Labview program. From the experimental results, the BPA algorithm proposed in this paper has over 90% accurate rate to identify the diameter of void defects and is expected to use reference data of maintenance and replacement of insulation for cast-resin transformers in the on-site PD measurement.

  • PDF

Nonoperative Management of Blunt Liver Trauma (둔상성 간 손상환자의 비수술적 치료)

  • Baik, Jung Ju;Kim, Jung Il;Choi, Seung Ho;Choi, Young Cheol;Jun, Si Youl;Lee, Jun Ho;Hwang, Seong Youn
    • Journal of Trauma and Injury
    • /
    • v.18 no.2
    • /
    • pp.161-171
    • /
    • 2005
  • Background: The management of hepatic injuries has changed dramatically during the past two decade after the technologic breakthroughs in radiologic imaging techniques. Recently, the non-operative management of blunt hepatic trauma has become the standard of care in hemodynamically stable patients. We reviewed our experience of the non-operative management of blunt hepatic trauma. And the purpose of this study was to examine the prognostic factors and indicators affecting the decision for treatment modality of emergent hepatic trauma. Methods: The medical records of 84 patients who were treated for blunt hepatic injury at Masan Samsung Hospital from January 2002 to December 2003. The patients were divided two groups, non-operative(Non-OP) and operative(OP), according to the treatment modality. The two groups were compares for age, sex, mechanism of injury, grade of liver injury scale, combined injury, systolic blood pressure, pulse rate, hemoglobin, hematocrit, WBC count, S-GOT, S-GPT, ALP, transfusion amount during initial 24 hours, amount of infused crystalloid fluid, length of ICU stay, length of ward care, morbidity and mortality. The grade of the liver injury were determined by using the organ injury scale(OSI). Results: Among the 84 patients, 46 cases(54.8%) were managed non-surgically, and 3 cases of Non-OP group were treated by transarterial embolization. Between the two groups, there were significant difference in age, injury grade, combined injury, hemoglobin, hematocrit, initial systolic blood pressure, amount of infused crystalloid fluid, amount of transfusion during the first 24 hours, and length of ICU care, morbidity and mortality.(p<0.05) The overall mortality rate was 8.3%, but 2.2% mortality in the non-operative group. Conclusion: Non-operative management may be considered as a first choice in hemodynamic stable patients with blunt liver trauma. The reliable indicators affecting the treatment modality of blunt hepatic trauma were systolic BP, Hb, Hct, amount of infused crystalloid fluid, amount of transfusion during the first 24 hours, liver injury grade and combined injury. Strict selection of treatment madality and aggresive monitoring with intensive care unit were more important.

Effect of misting and wallowing cooling systems on milk yield, blood and physiological variables during heat stress in lactating Murrah buffalo

  • Yadav, Brijesh;Pandey, Vijay;Yadav, Sarvajeet;Singh, Yajuvendra;Kumar, Vinod;Sirohi, Rajneesh
    • Journal of Animal Science and Technology
    • /
    • v.58 no.1
    • /
    • pp.2.1-2.10
    • /
    • 2016
  • Background: Heat stress adversely affects the physiological and metabolic status, and the productive performance of buffalo. Methods: The present study was conducted to explicate the effect of misting and wallowing cooling strategies during heat stress in lactating Murrah buffalo. The study was conducted for three months (May-July) of which first two months were hot dry and last month was hot humid. Eighteen lactating buffaloes, offered the same basal diet, were blocked by days in milk, milk yield and parity, and then randomly allocated to three treatments: negative control (no cooling), cooling by misting, and cooling by wallowing. Results: The results showed higher (P < 0.05) milk yield in buffaloes of misting and wallowing group compared to control during the experimental period however wallowing was found more (P < 0.05) effective during July (hot humid period). Both the treatments resulted into significant (P < 0.05) reduction in rectal temperature (RT) and respiratory rate (RR) compared to control animals during study period whereas wallowing was found to be effective on pulse rate (PR) only during July. Both treatments were resulted in mitigating the heat stress mediated decrease in packed cell volume (PCV), lymphocytopnoea and neutrophilia whereas decrease in total erythrocyte count (TEC) and monocytes was only mitigated by wallowing. Heat load induced alteration in serum creatinine and sodium concentration was significantly (P < 0.05) ameliorated by misting and wallowing whereas aspartate aminotransferase, alkaline phosphatase and superoxide dismutase activity, and reactive oxygen species concentration could be normalized neither by misting nor by wallowing. The significant (P < 0.05) increment in serum cortisol and prolactin levels observed in June and July period in control animals was significantly (P < 0.05) prevented by misting and wallowing. Conclusions: It can be concluded that misting and wallowing were equally effective in May and June (hot dry period) whereas wallowing was more effective during hot humid period in preventing a decline in milk production and maintaining physiological, metabolic, endocrine and redox homeostasis.

The Clinical Study on 40 Cases of Patient with Chronic Prostatitis (만성전립선염환자(慢性前立腺炎患者) 40예(例)에 대(對)한 임상적(臨床的) 고찰(考察))

  • Cho, Chung Sik;Kim, Chul Jung
    • Journal of Haehwa Medicine
    • /
    • v.8 no.2
    • /
    • pp.245-257
    • /
    • 2000
  • A clinical study was done 40 patients of chronic prostatitis who was treated in Dept. of Internal Medicine, Oriental Medicine Hospital, Taejon University, from 1 Mar. 1999 to 31 Oct. 1999. The results were as follows. 1. In distribution of age, 30's and 40's were 57.5% the most, 20's and 60's were 35.0%, 50's was 7.5%. 2. In distribution of past history, the urethritis(45.0%) was the most. 3. In distribution of ocupation, a white-collar worker was 35.0%, a business man was 22.5%, a public servant was 12.5%, etc. 4. Sitting the mean time of day were distributed 5~7 hours, above 7 hours, 3~5 hours, under 3 hours, etc. 5. The resting interval of a long distance drive were distributed 2 hours(35.0%), 3 hours(32.5%), etc. 6. The habit of enduring ejaculation during sexual intercourse was showed 45.0%. 7. The habit of enduring urination was showed 20.0%. 8. Influency of mental stress was showed 90.0%. 9. Ten cases(25.0%) were showed riding horse or riding bicycle. 10. Four cases(10.0%) were showed wearing tight trousers. 11. The habit of put a wallet his hip pocket was showed 57.5%. 12. The most common symptom was distributed the others symp-tom(66.8%) and the voiding symptom(63.3%) more than pain-neuro-logical symptom(37.5%) and symptom related with sexual function (26.6%). 13. In distribution of palpation, lower abdominal pain, lumbar pain, perineal or parascrotal pain were mostly showed right side. Moreover diagnosis of pulsation was weakly showed chi pulse of right. 14. Duration of disease were distributed above 1 year(82.5%), under 1 year(17.5%). Degree of prostatitis was severe showed adove 1 year. 15. The distribution of WBC count of the prostatic secretion, com-paring with before therapy and after therapy, were showed from 5 cases to 0 case in very many/HPF, from 23 cases to 13 cases in many/HPF, from 12 cases to 13 cases in 10~30/HPF, from 0 case to 13 cases in under 10/HPF. 16. Therapeutic improvement of symptom were distributed pain-neurological symptom(94.8%), the others symptom(90.8%), the void-ing symptom(89.6%) and symptom related with sexual function(67.5%). 17. Differentiation of symptoms and signs were distributed dificiency of spleen-lung vital energy, wetness-heat of lower warmer, dificiency of spleen-kidney yang, dificiency of kidney yin, wetness-phlegm, dificiency of vital energy and blood. The prescriptions were Bojungikgitang(44.6%), Yukmijihwangtang(20.7%), Palmijihwangtang(12.0%), etc.

  • PDF

An I/O Interface Circuit Using CTR Code to Reduce Number of I/O Pins (CTR 코드를 사용한 I/O 핀 수를 감소 시킬 수 있는 인터페이스 회로)

  • Kim, Jun-Bae;Kwon, Oh-Kyong
    • Journal of the Korean Institute of Telematics and Electronics D
    • /
    • v.36D no.1
    • /
    • pp.47-56
    • /
    • 1999
  • As the density of logic gates of VLSI chips has rapidly increased, more number of I/O pins has been required. This results in bigger package size and higher packager cost. The package cost is higher than the cost of bare chips for high I/O count VLSI chips. As the density of logic gates increases, the reduction method of the number of I/O pins for a given complexity of logic gates is required. In this paper, we propose the novel I/O interface circuit using CTR (Constant-Transition-Rate) code to reduce 50% of the number of I/O pins. The rising and falling edges of the symbol pulse of CTR codes contain 2-bit digital data, respectively. Since each symbol of the proposed CTR codes contains 4-bit digital data, the symbol rate can be reduced by the factor of 2 compared with the conventional I/O interface circuit. Also, the simultaneous switching noise(SSN) can be reduced because the transition rate is constant and the transition point of the symbols is widely distributed. The channel encoder is implemented only logic circuits and the circuit of the channel decoder is designed using the over-sampling method. The proper operation of the designed I/O interface circuit was verified using. HSPICE simulation with 0.6 m CMOS SPICE parameters. The simulation results indicate that the data transmission rate of the proposed circuit using 0.6 m CMOS technology is more than 200 Mbps/pin. We implemented the proposed circuit using Altera's FPGA and confimed the operation with the data transfer rate of 22.5 Mbps/pin.

  • PDF