• Title/Summary/Keyword: pulse analyzer

Search Result 153, Processing Time 0.025 seconds

Characteristic of the pulse wave in hypertension using pulse analyzer with array piezoresistive sensor (어레이 압저항 센서 장착 맥진기의 고혈압 맥파 특성)

  • Choi, Yong-Seok;Kim, Kyung-Yo;Hwang, Seung-Yeon;Kim, Jong-Yeol;Lee, Si-Woo;Kim, Hyun-Hee;Joo, Jong-Cheon
    • Korean Journal of Acupuncture
    • /
    • v.24 no.3
    • /
    • pp.105-116
    • /
    • 2007
  • Objectives : This study was performed to determine whether a pulse analyzer using array piezoresistive sensor was useful to characterize the variables of pulse wave of hypertentive patients (HT) , compared with those of healthy subjects. Methods : One hundred twenty two subjects participated in this study. Sixty nine subjects had hypertension and fifty three subjects had no specific history or disease associated with hypertension. We used automatic pulse analyzer with array piezoreslstive sensor. Results : Calibrated in Chon, no specific differences was between HT group and the healthy group. Calibrated in Gwan. sum of pulse pressure (SPP) of HT group was higher than that of the healthy group. Calibrated in Cheek, mean of height of main peak (Mm) and height of main peak (h1) of HT group were higher than those of the healthy group. Conclusions : Pulse analyzer was useful to determine the risk degree or development possibility of hypertension.

  • PDF

A Research of characteristics of left/right pulse wave and blood vessel using Korean medicine pulse diagnosis (맥진기를 이용한 좌우 맥파 및 혈관 특성 연구)

  • Kang, JinHo;Lee, Han-Byul;Kim, Ki-Wang;Kwon, Jung-Nam;Lee, Byung-Ryul
    • The Journal of Korean Medicine
    • /
    • v.35 no.3
    • /
    • pp.155-165
    • /
    • 2014
  • Objectives: The pulse diagnosis to identify the symptoms has been considered important in Korean medicine. The position and character of disease would be confirmed by pulse diagnosis of left and right radial artery. This paper is to analyze the characteristics and differences of left and right blood vessels. Methods: In this study, left and right radial artery and dorsalis pedis artery was measured and analyzed by using condenser typed pulse analyzer. Commercially available pulse analyzer was used to measure the radial artery. The pulse wave was measured in 20 laboratory healthy men and women. The blood vessel aging degree and index of augmentation of blood vessel was obtained from the measured pulse wave graph and the characteristics and differences of the left and right blood vessel was analyzed. Results: The significant difference of pulse transit time between the right handed and non-right handed was not found. The correlation of radial artery and dorsalis pedis artery had no significant difference. By obtaining the blood vessel aging index (AGI) and augmentation index (AI) of blood vessel at the left and right radial artery, the significant difference between right handed and non-right handed was not found. Conclusions: The result of this study would help to explain the characteristic of blood vessel with respect to the left and right handed. We suggest that research of pulse wave of the left and right blood vessel using pulse analyzer should be needed in further study.

A Study on the Sasang Constitutional Differences in the Pulse Wave of Korean Healthy Adult Men (한국인 성인 남성의 체질별 맥상 특성에 관한 연구)

  • Kim, Ho-Seok;Ryu, Hyun-Hee;Lee, Si-Woo
    • Korean Journal of Oriental Medicine
    • /
    • v.13 no.2 s.20
    • /
    • pp.71-74
    • /
    • 2007
  • Background : Sasang Constitutional Medicine (SCM) is the field of traditional Korean medicine that emphasize four constitutional types for diagnosis and treatment. Appearance, personalities and pathological characteristics are main factors of Sasang constitutional classification. Previous studies carried out by the pulse analyzer showed that the pulse wave can discriminate these types. In addition, It was reported that the pulse wave are affected by age and sexuality. In this study, we investigated the pulse wave characteristics related Sasang constitution types in control group regarding their age and sexuality. Subjects and Method : Two hudred and eighteen volunteers participated in this study: healthy men in $20{\sim}49$ years old. Participants were interviewed and examined to evaluate their health condition and Sasang constitution type. Then they were tested with pulse analyzer when they ere stabilized. The pulse at the radial artery just beside styloid process was measured, because this area is landmark for pulse diagnosis in oriental medicine. 3-D Mac pulse analyzer (Daeyo Medi Co. Ansan. Korea) was used in this study. We analyzed main features of pulse waves with the Sasang condtitution types by the SPSS for Windows (ver 12.0). Results : There was significant difference between Taeum and other types in contact pressure as weil as in coefficient of floating and sinking pulse. Conclusion : By analyzing pulse waves of healthy adult men. we found significant differences exist between Taeum and other types. These pulse differences may characterize Taeum type, and it will be helpful for the evaluation of Taeum type.

  • PDF

Oriental Pulse Diagnostic Apparatus with an emphasis on sense on fingers (수지부 감각정보에 중점을 둔 한의학적 전자 맥진 시스템에 대한 고찰)

  • Kim, Byoung-Chul;Chae, Han
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.9 no.2
    • /
    • pp.112-120
    • /
    • 2008
  • This study aims to develop a system for diagnosing pulse and disease conditions based on oriental medical classics to collect objective quantitative information in the traditional pulse examination environment that uses fingers. For this purpose, the study suggested a thimble-type sensor unit as the most appropriate pulse analyzer and proposed a traditional method to measure the pulse pressure wave on the spots of cheok, gwan and chon by installing the pulse analyzer on the forefinger, middle finger and medical finger. Then, it was interpretively found that this pulse analyzer enables us to objectively recognize 28 pulses defined in Oriental medical classics including the yukjo pulse, described as the buchimjisak-heosil pulse, and the hong, yoo, hyeok and san pulses. Finally, the study proposed a method to extract key parameters essential to pulse condition diagnosis from the pulse pressure wave measured by this pulse analyzer.

  • PDF

Retrospective Clinical Study of Pulse Wave Characteristics According to Healthy State Level in Sasang Constitution (사상체질 완실무병(完實無病) 수준에 따른 맥파(脈波) 특성의 후향적 임상 연구)

  • Su-Hyun Kim;Jun-Yong Park;Ho-In Kim;Jong-Cheon Joo
    • Journal of Sasang Constitutional Medicine
    • /
    • v.35 no.4
    • /
    • pp.1-9
    • /
    • 2023
  • Objectives This study is designed to examine the relationship between healthy state (完實無病) of Sasang constitution and pulse wave (脈波). Methods The subjects were 100 patients who were diagnosed with Sasang constitution and underwent pulse analyzer test. The status of urination, defecation, perspiration, and digestion was classified as good, intermediate, and poor. The power, depth, speed, and roughness of pulse waves (脈波) were analyzed. Results Patients with poor digestion had relatively powerless pulse wave (無力脈). Soeumin patients had a higher rate of poor digestion compared to other constitutions. Soyangin patients had a higher rate of poor perspiration compared to other constitutions. Soyangin with poor defecation had relatively choppy pulse wave (澁脈), and poor perspiraton had relatively slippery (滑脈). Soeumin patients with poor digestion had relatively powerless pulse wave (無力脈). Conclusions The pulse wave of poor healthy state (完實無病) is an expression of a pathological syndromes (病證) caused by lack of or damage to healthy energy (保命之主). It was concluded that the pulse analyzer can be used to evaluate healthy state (完實無病).

Correlations between Postpartum Edema and Pulse Energy Measured by 3D Blood Pressure Pulse Analyzer (3D Blood Pressure Pulse Analyzer로 측정한 맥파 에너지와 산후 부종과의 상관성 연구)

  • Lee, Ji-Yeon;Yun, Young-Jin
    • The Journal of Korean Obstetrics and Gynecology
    • /
    • v.27 no.1
    • /
    • pp.167-175
    • /
    • 2014
  • Purpose: This study was performed to find correlations between Edema Index and Pulse Energy in early postpartum period. Methods: Fiftynine postpartum women were participated in this study which was conducted with Inbody 720 (Biospace Co. Ltd) and 3D Blood Pressure Pulse Analyzer (3D-MAC). Edema Index (Extra Cellular Water/Total Body Water) calculated after body composition analysis and 3D-MAC result (Pulse Energy) were analysed within a week after delivery. Results: The results were as follows 1. Edema Indexes of the upper, lower limbs, trunk and whole body were associated with each other respectively. 2. Edema Indexes and Right Kwan pulse energy had significant positive correlation. 3. Right Kwan pulse energy showed positive correlations with Left Kwan, Right Chon, Right Cheok. Conclusions: Viscera associated with Postpartum Edema are Spleen, Lung, Liver and Vital Gate. The most important thing is thought to be Spleen.

A Study on the Relationship between Aging and Partial Discharge Characteristics of the Mica/Epoxy Composite Insulation Systems (l) (Mica/Epoxy 복합 절연계통의 부분방전 특성과 열화 관계에 관한 연구(I))

  • Kang, D.S.;Lee, W.Y.;Park, C.H.;Kwak, Y.S.;Kim, K.Y.
    • Proceedings of the KIEE Conference
    • /
    • 1992.07b
    • /
    • pp.976-979
    • /
    • 1992
  • There are lots of problem which are delaminations and partial discharge of insulation materials in high-voltage rotating machines caused by mechanical, electrical and thermal aging. Several experiments have been aiming at finding the useful diagnostic parameters from the partial discharge characteristics by applying a new measurement techniques. This paper deals with the partial discharge characteristics (pulse height, pulse angle, pulse frequency spectrum and time interval), which may be a useful diagnostic concept in predicting insulation condition of mica/epoxy composite insulation materials, by using several measurement equipments (frequency spectrum analyzer. multichannel analyzer and time interval analyzer).

  • PDF

Design of an integrated multiple-single-channel analyzer

  • Jie Yang;Xiaofei Gu;Shuxiang Lu;Guoheng Zheng
    • Nuclear Engineering and Technology
    • /
    • v.56 no.7
    • /
    • pp.2557-2562
    • /
    • 2024
  • A type of integrated multiple-single-channel analyzer (IMSCA) is described. The IMSCA works with an input pulse of 2-20 pC, and it can be directly connected to a scintillation detector, which eliminates the need for a linear amplifier. It consists of 64 input ports, so 1-64 detectors can be set by users according to different requirements. Two energy regions for each input channel can be simultaneously analyzed. Another advantage of the IMSCA is that it integrates with a high-speed pulse signal acquisition card and transmits data to the computer through the network. The maximum pulse through-rate is 1.4 MHz, and linearity can reach 0.1%. This IMSCA has been successfully used in enrichment detecting of nuclear fuel rod.

A Study on Personal and Lifestyle Factors that Affects Pulse Types (개체 요인 및 생활 습관 요인이 맥상에 미치는 영향)

  • Jung, Hyun-Jung;Yun, Sang-Hun;Kang, Won-Suk
    • The Journal of the Society of Korean Medicine Diagnostics
    • /
    • v.16 no.3
    • /
    • pp.11-22
    • /
    • 2012
  • Objectives: The aim of this study was to elucidate the relationship between pulse types measured by pulse analyzer and several factors including smoking, drinking alcohol, exercises etc. Methods: The subjects were 71 persons who were tested by oriental health examination. A self-reported questionnaire was used to gather age, smoking, drinking alcohol, exercise state and gender. The pulse types were measured by DMP 1000. The index of stress and fatigue were measured by SA 3000. We analyzed the frequency of pulse types according to gender, ages, smoking, drinking alcohol etc by chi-square test with SPSS ver. 19.0. Results: In the main pulse types, there were significant differences according to age(p<0.05) and marginal differences according to drinking alcohol(p<0.1). In the secondary pulse types, there were marginal differences according to exercise, ages. But there was no significant differences according to gender, smoking, body mass index (BMI), accelerated photoplethysmography (APG) feature, stress and fatigue. Conclusions: This study suggests that the pulse types are affected by drinking alcohol, ages, exercise.

A Study on the Relationship between Primary Dysmenorrhea and Pulse Energy Measured by 3D Blood Pressure Pulse Analyzer (원발성 월경곤란증과 맥의 관련성 연구)

  • Lee, Ji-Yeon;Yoon, Young-Jin
    • The Journal of Korean Obstetrics and Gynecology
    • /
    • v.28 no.4
    • /
    • pp.31-45
    • /
    • 2015
  • Objectives : The purpose of this study is to examine the relationship between the symptoms of primary dysmenorrhea and pulse energy of Chon, Gwan and Cheok. Methods The subjects of this study who had certain range of dysmenorrhea symptom. The degree of dysmenorrhea were assessed by Visual Analog Scale (VAS), Multidimensional Verbal Rating Scale (MVRS), Cox Menstrual Symptom Scale (CMSS) and measured by 3D Blood Pressure Pulse Analyzer(3D-MAC) tests at menstruation start date. Data analysis included descriptive statistics and multiple linear regression using the SPSS/WIN 18.0 program. Results : The induced results are as follows;The induced results are as follows 1. There were no significant relationship between the pulse energy and the sum values of VAS, MVRS and checking part of severity of CMSS. 2. The frequency domain of CMSS were significantly associated with pulse energy. 3. In linear regression models, the model of Left Chon had the especially highest value of explanatory power. (R 2 = 0.517) Conclusions : The pulse energy changes are related to the symptoms of primary dysmenorrhea.