Evaluation of Insertion of torque and Pull-out strength of mini-screws according to different thickness of artificial cortical bone (다양한 교정용 미니 스크류의 인공 피질골 두께에 따른 삽입 토오크와 Pull-out 강도 비교)

  • Song, Young-Youn;Cha, Jung-Yul;Hwang, Chung-Ju
    • The korean journal of orthodontics
    • /
    • v.37 no.1 s.120
    • /
    • pp.5-15
    • /
    • 2007
  • Objective: The purpose of this study was to evaluate the mechanical performance of mini-screws during insertion into artificial bone with use of the driving torque tester (Biomaterials Korea, Seoul, Korea), as well as testing of Pull-out Strength (POS). Methods: Experimental bone blocks with different cortical bone thickness were used as specimens. Three modules of commercially available drill-free type mini-screws (Type A; pure cylindrical type, Biomaterials Korea, Seoul, Korea, Type B; partially cylindrical type, Jeil Medical, Seoul, Korea, Type C; combination type of cylindrical and tapered portions, Ortholution, Seoul, Korea), were used. Results: Difference in the cortical bone thickness had little effect on the maximum insertion torque (MIT) in Type A mini-screws. But in Type B and C, MIT increased as the cortical bone thickness Increased. MIT of Type C was highest in all situations, then Type B and Type A in order. Type C showed lower POS than Type A or B in all situations. There were statistically significant correlations between cortical bone thickness and MIT, and POS for each type of the mini-screws. Conclusion: Since different screw designs showed different insertion torques with increases in cortical bone thickness, the best suitable screw design should be selected according to the different cortical thicknesses at the implant sites.

Pull-out repair for root tear of medial meniscus (내측 반월상 연골 후방 골 기시부 파열의 수술적 봉합술)

  • Kim, Deok-Weon;Moon, Jeong-Seok;Kim, Min-Gun;Kim, Jin-Goo
    • Journal of the Korean Arthroscopy Society
    • /
    • v.9 no.1
    • /
    • pp.40-45
    • /
    • 2005
  • Purpose: This study is to evaluate the clinical findings of media] meniscus root tear, pull-out repair technique and it's short term results. Materials and Methods: From September 2003 to August 2004, 23 cases of total 27 medial meniscus root tears were treated by pull-out repair technique. Mean age was 60.2 years old. The pull-out technique was divided into 2 groups In group 1(14/23 cases), anterolateral portal was used and in group 2(9/23 cases), anterolateral and posteromedial portals were used for bed preparation. Concomitant cartilage lesions were documented as ICRS mapping system. The clinical outcomes were evaluated according to Lysholm Knee Score. Results: The postoperative Lysholm Knee Score was 77.1(range; $58{\sim}97$) in group 1 and 81.4(range; $72{\sim}94$) (p>0.05). The failure rate was 3 of 14 cases(21.4%) in group 1 and 1 of 9 cases(11.1%) in group 2. Twenty of 22 cases(90.9%) showed cartilage lesions in weight bearing portion of medial femoral condyle which were 8 grade III and 5 grade IV according to the Outerbridge classification. Conclusion: Pull-out repair seems to be a useful treatment of the medial meniscus root tear for preservation of circumferential hoop tension of meniscus.

  • PDF

Pull-out Capacity of Cast-in-place Anchor for Construction of Precast Concrete Segment Arch (프리캐스트 콘크리트 패널 분절 아치 시공을 위한 선설치 앵커의 인발 강도 평가)

  • Ahn, Jin-Hee;Yim, Hong Jae;Bang, Jin Soo;Jeon, Seok Hyeon
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.24 no.2
    • /
    • pp.94-102
    • /
    • 2020
  • Precast concrete segment arch system has an economic and construct ability that combined with advantage of precast concrete and arch behavior. A precast concrete segment arch system with outrigger is consisted of segmented precast panels, a steel outrigger rib, and V-strip to connect precast panels with a steel outrigger rib and cast-in-place anchors in precast panels to connect V-strip should have sufficient pull-out capacity to form its arch shape by site lifting for assembled precast panels and outriggers. However, it is difficult to secure its embedment depth due to the relatively shallow thickness of precast panel. It can be also occurred that flexure deformation of precast panels caused by its pull-out behaviors. In this study, pull-out capacity of cast-in-place anchor was examined for construction of precast concrete segment arch system with outriggers. Therefore, a total of 24 precast panel specimens were fabricated to examine pull-out capacities of cast-in-place anchor in precast panels, and installation depth of anchors, diameter of anchors and wire mesh effects for the precast panel were examined. From this pull-out tests, its pull-out capacities and failure modes were evaluated and the type of the cast-in-place anchor applicable to the precast concrete segment panel arch system with outriggers was determined from comparison of the design specification values.

Effects of Screw Diameter and Thread Shape on the Strength of Transpedicular Screw Fixation in Posterior Spinal Fusion (후방 척추고정술에서 척추경 나사못의 크기와 형태가 척추 고정력에 미치는 영향에 대한 연구)

  • Mun, Mu-S.;Ryu, Jei-C.;Yoo, Myung-C.;Kim, Ki-T.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1995 no.05
    • /
    • pp.23-26
    • /
    • 1995
  • The objectives of the present study are 1)to find the effect of the diameter of transpedicular screws on their fixational strength in pedicles under static pull-out loading, 2)to determine the biomechanical correlation between the pedicle diameter and the screw diameter, and 3)to find the effects of other factors in the screw design, such as materials, screw pitch, thread height and shape on their fixational strength. Biomechanical tests (Test I) were performed to evaluate the effect of the screw diameter on pull-out strength by using 60 porcine pedicls and six groups of custom-made pedicle screws with different diameters (the major and the minor diameter of the screws used in the testing varied from 4mm upto 9mm and from 3mm upto 8mm, respectively) while all other factors (materials, screw pitch, thread height and shape etc.) were fixed. In Test II, by using 61 porcine pedicles, the relationship between the ratio of the pedicle diameter and the screw diameter(=aspect ratio) of the custum-made screw and the pull-out strength of the screw was investigated. Test III was performed with 94 porcine pedicles and 8 different types of the commercial screws from 6 major productors in order to determine the effect of the screw diameter, pitch and the thread shape on the pull-out strength of the screw, respectively. The results of Test I showed that the axial pull-out resistance of the screw could be increased prportionaly to the screw diameter(P<0.05). But this increase in the pull-out resistance did not found when the screws of 4mm or 9mm in the diameter were employed. It was found from the results of Test II that the screws had its maximum pull-out resistant force when the aspect ratio ranging 40 - 69% (P<0.05). based on the results for the major diameter against the minor diameter of screw, the maximal pull-out resistance was found at 60-65% (P<0.05). According to these biomechanical testing results, it seems that the screw with a moderately large pitch is more desirable and the buttress-shaped screw can provide stronger fixation than the V-shape one can, if other designal factor and conditions were fixed.

  • PDF

Field Pull-out Test and 3-D FEM Analysis for Steel Pipe Nailing Installed Foldable Wedge (접이식 웨지 장착 강관네일의 현장 인발시험 및 3차원 유한요소해석)

  • Kwon, Kyo-Keun;Choi, Bong-Hyuck
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.29 no.6C
    • /
    • pp.313-319
    • /
    • 2009
  • In this study, field pull-out test and 3-D FEM analysis have been performed for examining and reflecting the behavior of steel pipe nailing installed foldable wedge. Field pull-out test was performed under various conditions. As a result, the steel pipe nailing installed foldable wedge has an effect of pull-out resistance increased about 30% in comparison with non-wedge type steel pipe nailing. Through back analysis in 3-D FEM for behavior of non-wedge type steel pipe nailing, friction characteristics between nail to soil was analyzed and obtained first consistent with field pull-out behavior. Then, the frictional characteristic was used for analyzing the behavior of the steel pipe nailing installed foldable wedge. The result was compared with the test results. Consequently, friction coefficient (${\mu}$) of about 1.2 between grout to soil leads to good agreement with analysis results and test results. And a limited pull-out resistance, $$T_L{\sim_=}32$$ tonf is similar to field pull-out test result which is improved about 33% in comparison with non-wedge type steel pipe nailing's $$T_L{\sim_=}24$$ tonf.

A Newly Designed Miniplate Staple for High Tibial Osteotomy (근위골절술을 위한 Staple 설계)

  • Mun, Mu-Seong;Bae, Dae-Kyung
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1995 no.05
    • /
    • pp.19-22
    • /
    • 1995
  • A biomechanical study was made to demonstrate the superior mechanical performance of the newly designed Miniplate staple to the conventional Coventry staple in high tibial osteotomy(HTO). Using twenty fresh porcine tibiae, the fixational strengh of the two different types of staple in HTO was compared. To minimize the error due to the specimen-to-specimen individuality, the bone mineral density of the tibiae was measured with a bone densitometry (Dual photon absorptionometer, Luner, USA) and those with $0.8\;{\sim}\;1.2\;gm/cm^2$ at the proximal tibia was used in the biomechanical test. Testing was performed on a material testing system (Autogram ET-5, Shimatzu, Japan) with aid of a commercial data processor (IBM 80386/ ASYST). Using two differant loading modes, 'pull-out' and 'push-out', the maximum resistant force required to release the staple from the substrate bone was recorded. In the pull-out test, ten non-osteotomized specimens were used and the staple was pullout by subjecting an axial tension on the head of the staple inserted. While in the pull-out test where ten tibiae osteotomized in the usual way of HTO were used, the staple was not directly loaded. In this testing, as a mimic condition of the natural knee, the distal part of the specimen tibia was pushed horizontally in order for the staple to be pulled out while the proximal tibia was fixed. The pull-out strength of Coventry staple and miniplate staple were found to be $27.88\;{\pm}\;5.12\;kgf$ and $182.47\;{\pm}\;32.75\;kgf$, respectively. The push-out strength of Coventry staple and miniplate staple were $18.40\;{\pm}\;4.47\;kgf$ and $119.95\;{\pm}\;19.06\;kgf$, respectively. The result revealed that miniplate staple had the pull-out/ push-out strength at least fivetimes higher than Coventry staple. Based on the measured data, it was believed that the newly designed miniplate staple could provide much better postoperative fixation in HTO. The postoerative application of long leg casting may not be needed after HTO surgery.

  • PDF

Behavior of Traveling Vehicle According to Soil Properties (토질특성에 따른 이동차량의 거동)

  • 박영호;김운영
    • Geotechnical Engineering
    • /
    • v.13 no.2
    • /
    • pp.125-136
    • /
    • 1997
  • The fullsized drawbar pull test is carried out in Yeog-gol area to find out the effect of test vehicle's trafficability with the variation of density and water content at the weathered granite soils and water content at the clayey soils. According to the results, it is found that the behavior of optimum drawbar pull is effected not only by water content but also by density. This paper showed the method of determination of optimum points at a curve of drawbar pull varying with the conditons of soils. And it also showed the optimum drawbar pull coefficient and optimum slip varying with the density of the weathered granite soils.

  • PDF

Determination of Performance Determinant Factors in Snatch Weightlifting (여자역도 인상종목의 경기력 결정요인 산출)

  • Moon, Young-Jin
    • Korean Journal of Applied Biomechanics
    • /
    • v.15 no.2
    • /
    • pp.21-29
    • /
    • 2005
  • The Purpose of this study was to seek determinant factors through analysis of 65 snatch skill kinematic factors of Athletics participated in 2001 Asian weightlifting competetion. The conclusion were as follows ; 1. In order to enhance snatch skill, when barbell move on knee position, One should be flex knee joint to 105-110 degree, and In pull motion, One should be move powerful extension of knee and hip joint. 2. In last pull motion, One try to make more lock out motion than extra extention motion of hip joint 3. In order to enhance snatch skill, It is inportant that elevate barbell highly by last pull motion through powerful knee extention, poweful hip flextion and One should be make lock out motion fast in the same time. 4. In order to enhance snatch skill, anterior-posterior movement width of shoulder joint should be small. 5. In order to enhance snatch skill, Hip joint should be move vertically on start and lock out phase, but In pull phase, extension motion of hip joint shoulde be performed more largely and powerfully.

A FINITE ELEMENT ANALYSIS OF THE STRESS DISTRIBUTION AND DISPLACEMENT OF an in-vitro HUMAN MANDIBLE TO THE ORTHOPEDIC FORCE (정형력(整形力)에 대(對)한 하악골내(下顎骨?)의 응력분산(應力分散)과 변위(變位)에 관(關)한 유한요소법적(有限要素法的) 분석(分析))

  • Choue, Ho Koo
    • The korean journal of orthodontics
    • /
    • v.14 no.1
    • /
    • pp.75-92
    • /
    • 1984
  • This study attempted to analyze the distribution of stress, to examine the bending effect in the mandible according to the pulling directions and determine on which pulling directions are adequate when an orthopedic force was applied to the mandible. An orthopedic force, 500gm, was applied to the gnathion, one point of the chin area, in three directions. The three directions were ; high puli' from gnathion to the center of condyle head, and vertical pull, from gnathion to a parallel line with the posterior border of the ramus, and medium pull, from the gnathion to a parallel line with the lower border of mandible. The distribution of principal stress, bending moment and amount of displacement within the mandible was analyzed by a 3-dimensional finite element method and that of the various portions of mandible were computed and compared according to the pulling directions. The results were as follows : 1. The bending moment of each part of a mandible has been found to be markedly larger in case of vertical pull than in case of either high pull or medium pull. In vertical pull the bending moment turned out to largest at the condyle head and neck portion, the gonial angle portion, the coronoid portion and the ascending ramus portion, respectively, while comparatively large at the cuspid and bicuspid portion and the first molar portion. In case of high pull it was largest at the gonial angle portion and becoming smaller at the coronoid portion, the ascending ramus portion, the condyle head and neck portion, and the cuspid and bicuspid portion, in that order. In case of medium pull, however, the bending moment was largest at the condyle head and neck portion, becoming smaller at the first molar portion, the ascending ramus portion, the coronoid portion, the cuspid and bicuspid portion, and gonial angle portion, in that order. 2. As for the bending effect it was calculated to be mostly oriented downward at the mandibular body and backward at the mandibular ramus in both high pull and vertical pull. In case of medium pull it was oriented upward at the mandibular body and forward at the mandibular ramus. 3. The bending effect also turned out to be mostly oriented outward in case of high pull and medium pull, and inward in vertical pull. 4. At the mandibular body and ramus, the bending effect in the upward-downward direction and that in the forward-backward direction were found to be larger than in the inward-outward direction. 5. If and when we expect any correcting effect on the mandibular protrusion by means of the chin cup appliance, we can say sure as conclusion that high pull and vertical pull are more effective than medium pull.

  • PDF

Optimum Curing and Full-out Velocity in the Rubber Extrusion Process for Electric Cable Manufacture (전선피복용 고무압출가공 공정의 최적 경화 및 선출 속도)

  • Kim, Duk-Joon;Choi, Sang-Soon;Kim, Tae-Ho
    • Elastomers and Composites
    • /
    • v.33 no.2
    • /
    • pp.93-102
    • /
    • 1998
  • In electric cable industries, the curing extent of the rubber materials covering the electric cores gives an significant effect on their final performance. The curing extent of rubber is controlled mostly by pull-out velocity of cable in the extrusion process. The final curing extent may be different for different radial positions inside the rubber because of the non-uniform temperature distributions during the curing process. In this contribution, the prediction of curing extent distribution throughout the radial direction of rubber is represented when the cable is passing through the steam curing zone with a fixed pull-out velocity. The prediction of the optimum pull-out velocity for the desired curing extent distribution is also reported. The steady-state heat balance was developed for the curing and cooling processes in which the pull-out rubber was cured by high temperature steam and then cooled by ambient water. A few essential material properties such as density, specific heat, and thermal conductivity were measured to analyze the temperature distribution during the curing and cooling processes. The times to reach 90% curing extent at varying temperatures were measured and used to determine the final cure extent distribution inside the rubber.

  • PDF