• 제목/요약/키워드: pull-out

검색결과 751건 처리시간 0.024초

지반앵커의 인발시험을 위한 개별제어 긴장장치의 적용 사례 연구 (A Case Study on Individually Controlled Pull-out Test for Ground Anchor)

  • 신현철;최용규
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2008년도 춘계 학술발표회 초청강연 및 논문집
    • /
    • pp.545-552
    • /
    • 2008
  • To insure the quality and safety of ground anchors, pull-out test of anchor has to be done. In the individually controlled pull-out test system, pull-out device is used to introduce the same pull-out force to individual tendon that has a different length and a deflection. That is, that device has a separate pull-out oil jack to each tendon, thus the pull-out length of each jack is not the same, but that device introduces each tendon to the same pull-out force. In this study, the in-situ pull-out tests for the compression anchors were performed and its test results were analysed and compared to the results of center hole pull-out tests. In the case of pulling out each tendon using the individually controlled pull-out test device, the pull-out forces were distributed to a individual tendon. That device is excellent one that can solve the cause of unequal pull-out forces of each tendon appearing in the manufacture process and construction of anchors, and unequal pull-out forces due to the deferent length.

  • PDF

화강 풍화토/지오그리드 인발시험 및 마찰특성 평가 (Evaluation of Weathered Granite Soil l Geogrid Friction Properties and Pull out Test)

  • 조삼덕;김진만
    • 한국지반공학회지:지반
    • /
    • 제12권4호
    • /
    • pp.87-100
    • /
    • 1996
  • 그리드(grid) 형태의 토목섬유와 흙 사이의 마찰특성은 표면마찰 뿐만아니라 그리드에 의한 수동저항을 동시에 측정할 수 있는 인발시험(pull-out test)에 의해 평가되고 있다. 본 연구에서는 보강토 구조물에서 가장 많이 사용되고 있는 지오그리드(geogrid)와 국내에 널리 분포되어 있는 화강 풍화토를 대상으로 실내 인발시험을 수행하였으며, 인발시험의 주요 영향 인자들인 인발속도, 토조 전면벽의 위치, 지오그리드 시료의 폭 및 지오그리드 수동 저항부재의 유.무 등이 흙/지오그리드 마찰특성에 미치는 영향을 평가하였다.

  • PDF

사질토지반에 근입된 벨타입 인발말뚝의 하중-변위 특성 (Load-displacement characteristics of belled tension piles embeded in cohesionless soils)

  • 홍원표;최용성;임대성
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2010년도 춘계 학술발표회
    • /
    • pp.1114-1119
    • /
    • 2010
  • Pile foundations have been used for upholding superstructure's loads. The researches on pile foundations subjected to compressive forces or horizontal loads have been actively carried out. However, recently, pile foundations, which are subjected to pull-out forces, are getting increased. The study on the pull-out resistance of piles becomes to be important. In addition, it is expected that belled piles will be used more and more, since the belled piles are effective to resist the pull-out forces. But there is still a lack of research on pull-out resistance of belled piles. Therefore, in order to investigate the resisting effect against pull-out of belled piles which is embedded in cohesionless soil. a series of pull-out test is performed on belled piles in field. Especially, the relation between load and displacement is analyzed through the pull-out test.

  • PDF

현장인발시험을 통한 제거식 쏘일네일의 거동특성 평가 (Evaluation of Behavior Characteristics of Removable Soil Nails from the Field Pull-Out Tests)

  • 김홍택;강인규;이대형;정성필;박시삼
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 1999년도 봄 학술발표회 논문집
    • /
    • pp.137-144
    • /
    • 1999
  • Recently a removable soil nail is demanded due to problems beyond of economical and engineering purpose. In this study removable soil nails are developed and field pull-out tests are carried out 16 times in order to analysis pull-out characteristics of the removable soil nail. For the spacing and the installed position of fixed socket, the length of the soil nail, and W/C ratio of cement grout in the removable soil nail, pull-out characteristics of pull-out tests are analyzed. From the pull-out characteristics of removable soil nails, it is found that the spacing of fixed socket and W/C ratio of cement grout are important design parameters.

  • PDF

Magnetic resonance imaging analysis of screw in-type lateral anchor pull-out in large to massive rotator cuff repair in patients older than 60 years

  • Lee, Sang-Yoon;Noh, Young-Min
    • Clinics in Shoulder and Elbow
    • /
    • 제25권1호
    • /
    • pp.15-21
    • /
    • 2022
  • Background: This study was performed to identify the incidence of screw in-type lateral anchor pull-out in patients older than 60 years who underwent rotator cuff repair for large to massive rotator cuff tear (RCT). Methods: We reviewed 25 patients over 60 who were diagnosed with large to massive RCT and underwent arthroscopic rotator cuff repair in our hospital from March 2017 to February 2021. Preoperative tear size (anterior to posterior, medial to lateral) was measured via preoperative magnetic resonance imaging (MRI). All 25 patients underwent MRI scanning on postoperative day 1 and at 3 months after surgery. The change of anchor position was measured in axial views on MRI images postoperative day 1 and 3 months after surgery. And it was statistically compared according to bone mineral density (BMD), sex, and number of lateral anchors. Results: Two MRIs (postoperative day 1 and 3 months) in 25 patients were compared. Anchor pull-out occurred in six patients during 3 months (6.7%), and the mean pull-out length difference was 1.56 mm (range, 0.16-2.58 mm). There was no significant difference in the number of pull-out anchors, degree of pull-out difference by comparing BMD (A, BMD≤-2.5; B, BMD>-2.5), sex, or number of anchors used in each surgery (C, two anchors; D, three anchors) (p>0.05). Conclusions: Pull-out of screw in-type anchors was rarely observed and the mean pull-out length difference was negligibly small in our study. The screw in-type lateral anchor seems to be a decent option without concern of anchor pull-out even in elderly patients.

포화토내 나선형 앵커의 무리효과에 관한 실험적 고찰 (Small Scaled Pull-out Tests on Group Effect of Screw Anchors in Saturated Sand)

  • 김홍택;권영호;박사원;최영하
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2000년도 봄 학술발표회 논문집
    • /
    • pp.387-394
    • /
    • 2000
  • In the present study, laboratory pull-out tests with screw anchors are carried out to investigate behavior characteristics of underground structures applied uplift seepage forces. Small scaled pull-out tests in sand were conducted under saturated condition. And then, it was observed that the upward displacement as well as the pullout load varied with spacing of the anchor. Also, analyses have been performed with the aim of pointing out the effects of various parameters on the group effect of the screw anchors.

  • PDF

Pull-out Strengths of GFRP-Concrete Bond Exposed to Applied Environmental Conditions

  • Kabir, Muhammad Ikramul;Samali, Bijan;Shrestha, Rijun
    • International Journal of Concrete Structures and Materials
    • /
    • 제11권1호
    • /
    • pp.69-84
    • /
    • 2017
  • This paper presents results of an experimental investigation on the behaviour of bond between external glass fibre reinforced polymer reinforcement and concrete exposed to three different environmental conditions, namely, temperature cycles, wet-dry cycles and outdoor environment separately for extended durations. Single shear tests (pull-out test) were conducted to investigate bond strengths (pull-out strengths) of control (unexposed) and exposed specimens. Effect of the exposure conditions on the compressive strength of concrete were also investigated separately to understand the effect of changing concrete compressive strength on the pull-out strength. Based on the comparison of experimental results of exposed specimens to control specimens in terms of bond strengths, failure modes and strain profiles, the most significant degradation of pull-out strength was observed in specimens exposed to outdoor environment, whereas temperature cycles did not cause any deterioration of strength.

현장인발시험을 통한 가압 그라우팅 쏘일네일의 장기 인발거동특성 (Long-term Behaviour Characteristics of Pressurized Grouting Soil Nails from the Field Pull-Out Tests)

  • 박시삼;이훈연;박주석;이홍규
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2005년도 춘계 학술발표회 논문집
    • /
    • pp.137-144
    • /
    • 2005
  • Recently a pressurized grouting soil nail is demanded due to problems beyond of economical and engineering purpose. In this study, a newly modified soil nailing technology named as the PGSN (Pressurized Grouting Soil Nailing) system is respected to reduced displacements of nails and increase of global slope stability. And effects of various factors related to the design of the PGSN system, such as the length of the soil nail, injected pressure and W/C ratio of cement grout in the pressurized grouting soil nail are examined throughout a series of the displacement-controlled field pull-out tests. Displacement-controlled field pull-out tests are performed in the present study and the volume of grouting are also evaluated based on the measurements. In addition, both short-term and long-term characteristics of pull-out deformations of the newly proposed PGSN system are analyzed and compared with those of the general soil nailing system by carrying out the stress-controlled field pull-out tests. From the pull-out characteristics of pressurized grouting soil nails, it is found that the effect of the length of the soil nail, injected pressure and W/C ratio of cement grout are important parameters.

  • PDF

Numerical modelling of the pull-out response of inclined hooked steel fibres

  • Georgiadi-Stefanidi, Kyriaki;Panagouli, Olympia;Kapatsina, Alexandra
    • Advances in concrete construction
    • /
    • 제3권2호
    • /
    • pp.127-143
    • /
    • 2015
  • Steel fibre reinforced concrete (SFRC) is an anisotropic material due to the random orientation of the fibres within the cement matrix. Fibres under different inclination angles provide different strength contribution of a given crack width. For that the pull-out response of inclined fibres is of great importance to understand SFRC behaviour, particularly in the case of fibres with hooked ends, which are the most widely used. The paper focuses on the numerical modelling of the pull-out response of this kind of fibres from high-strength cementitious matrix in order to study the effects of different inclination angles of the fibres to the load-displacement pull-out curves. The pull-out of the fibres is studied by means of accurate three-dimensional finite element models, which take into account the nonlinearities that are present in the physical model, such as the nonlinear bonding between the fibre and the matrix in the early stages of the loading, the unilateral contact between the fibre and the matrix, the friction at the contact areas, the plastification of the steel fibre and the plastification and cracking of the cementitious matrix. The bonding properties of the fibre-matrix interface considered in the numerical model are based on experimental results of pull-out tests on straight fibres.

Assessment of pull-out behavior of tunnel-type anchorages under various joint conditions

  • Junyoung Ko;Hyunsung Lim;Seunghwan Seo;Moonkyung Chung
    • Geomechanics and Engineering
    • /
    • 제36권1호
    • /
    • pp.71-81
    • /
    • 2024
  • This study analyzes the pull-out behavior of tunnel-type anchorage under various joint conditions, including joint direction, spacing, and position, using a finite element analysis. The validity of the numerical model was evaluated by comparing the results with a small-scaled model test, and the results of the numerical analysis and the small-scaled model test agree very well. The parametric study evaluated the quantitative effects of each influencing factor, such as joint direction, spacing, and position, on the behavior of tunnel-type anchorage using pull-out resistance-displacement curves. The study found that joint direction had a significant effect on the behavior of tunnel-type anchorage, and the pull-out resistance decreased as the displacement level increased from 0.002L to 0.006L (L: anchorage length). It was confirmed that the reduction in pull-out resistance increased as the number of joints in contact with the anchorage body increased and the spacing between the joints decreased. The pull-out behavior of tunnel-type anchorage was thus shown to be significantly influenced by the position and spacing of the rock joints. In addition, it is found that the number of joints through which the anchorage passes, the wider the area where the plastic point occurs, which leads to a decrease in the resistance of the anchorage.